Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Modeling resonance interference by 0-D slowing-down solution with embedded self-shielding method

The resonance integral table based methods employing conventional multigroup structure for the resonance self-shielding calculation have a common difficulty on treating the resonance interference. The problem arises due to the lack of sufficient energy dependence of the resonance cross sections when the calculation is performed in the multigroup structure. To address this, a resonance interference factor model has been proposed to account for the interference effect by comparing the interfered and non-interfered effective cross sections obtained from 0-D homogeneous slowing-down solutions by continuous-energy cross sections. A rigorous homogeneous slowing-down solver is developed with two important features for reducing the calculation time and memory requirement for practical applications. The embedded self-shielding method (ESSM) is chosen as the multigroup resonance self-shielding solver as an integral component of the interference method. The interference method is implemented in the DeCART transport code. Verification results show that the code system provides more accurate effective cross sections and multiplication factors than the conventional interference method for UO{sub 2} and MOX fuel cases. The additional computing time and memory for the interference correction is acceptable for the test problems including a depletion case with 87 isotopes in the fuel region. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of nodal coverage utilizing image guided radiation therapy for primary gynecologic tumor volumes

Purpose: To evaluate radiation dose delivered to pelvic lymph nodes, if daily Image Guided Radiation Therapy (IGRT) was implemented with treatment shifts based on the primary site (primary clinical target volume [CTV]). Our secondary goal was to compare dosimetric coverage with patient outcomes. Materials and methods: A total of 10 female patients with gynecologic malignancies were evaluated retrospectively after completion of definitive intensity-modulated radiation therapy (IMRT) to their pelvic lymph nodes and primary tumor site. IGRT consisted of daily kilovoltage computed tomography (CT)-on-rails imaging fused with initial planning scans for position verification. The initial plan was created using Varian's Eclipse treatment planning software. Patients were treated with a median radiation dose of 45 Gy (range: 37.5 to 50 Gy) to the primary volume and 45 Gy (range: 45 to 64.8 Gy) to nodal structures. One IGRT scan per week was randomly selected from each patient's treatment course and re-planned on the Eclipse treatment planning station. CTVs were recreated by fusion on the IGRT image series, and the patient's treatment plan was applied to the new image set to calculate delivered dose. We evaluated the minimum, maximum, and 95% dose coverage for primary and nodal structures. Reconstructed primary tumor volumes were recreated within 4.7% of initial planning volume (0.9% to 8.6%), and reconstructed nodal volumes were recreated to within 2.9% of initial planning volume (0.01% to 5.5%). Results: Dosimetric parameters averaged less than 10% (range: 1% to 9%) of the original planned dose (45 Gy) for primary and nodal volumes on all patients (n = 10). For all patients, ≥99.3% of the primary tumor volume received ≥ 95% the prescribed dose (V95%) and the average minimum dose was 96.1% of the prescribed dose. In evaluating nodal CTV coverage, ≥ 99.8% of the volume received ≥ 95% the prescribed dose and the average minimum dose was 93%. In evaluating individual IGRT sessions, we found that 6 patients had an estimated minimal nodal CTV dose less than 90% (range: 78 to 99%) of that planned. With a median follow-up of 42.5 months, 2 patients experienced systemic disease progression at an average of 19.6 months. One patient was found to have a local or regional failure with an average follow-up of 42 months. Conclusion: Using only 3 dimensional IGRT corrections in gynecological radiation allows excellent coverage of the primary target volume and good average nodal CTV coverage. If IGRT corrections are based on alignment to the primary tumor volume, and is only able to be corrected in 3 degrees, this can create situations in which nodal volumes may be under dosed. Utilizing multiple IGRT sessions appears to average out dose discrepancies over the course of treatment. The implication of underdosing in a single IGRT session needs further evaluation in future studies. Based on the concern of minimum dose to a nodal target volume, these findings may signal caution when using IGRT and IMRT in gynecological radiation patients. Possible techniques to overcome this situation may include averaging shifts between tumor and nodal volume, use of a treatment couch with 6° of freedom, deformable registration, or adaptive planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shape optimization using a NURBS-based interface-enriched generalized FEM

This study presents a gradient-based shape optimization over a fixed mesh using a non-uniform rational B-splines-based interface-enriched generalized finite element method, applicable to multi-material structures. In the proposed method, non-uniform rational B-splines are used to parameterize the design geometry precisely and compactly by a small number of design variables. An analytical shape sensitivity analysis is developed to compute derivatives of the objective and constraint functions with respect to the design variables. Subtle but important new terms involve the sensitivity of shape functions and their spatial derivatives. As a result, verification and illustrative problems are solved to demonstrate the precision and capability of the method.

42 ENGINEERING↗

A novel design optimization framework to sustain remanufacturability

The ever-increasing global carbon emissions have urged the need for environmentally conscious/sustainable product design, for which the design for remanufacturing (DfRem) is one potential approach. DfRem targets at designing products that have multiple life cycles, thus significantly reducing raw material usage, energy consumption, and carbon emissions. In this paper, we develop a three-stage framework that consists of (1) systematic design space exploration and a multi-objective optimization formulation to minimize the likelihood of failure causes (such as fatigue and wear) and environmental footprint, (2) topology optimization to further reduce material usage without significantly affecting the load-carrying capability of the product, and (3) post-topology optimization design verification to ensure the proposed design satisfies all design constraints. The environmental impact can be assessed at varying comprehensiveness levels (e.g., design and manufacturing phase, use phase) and in terms of carbon or GHG emission, energy use, and waste generation. Because the novel design framework predominantly adjusted the geometry, we focused on mass-based change and energy savings due to sustained remanufacturability. The multi-objective optimization formulation in the first step results in a Pareto optimal set of possible design solutions that the designer can use for the second step. Finally, we demonstrate the utility of this framework through a case study of an engine cylinder head subjected to thermo-mechanical loads, where we find that about 5% of the product mass can be conserved with only about a 3% increase in surface area that has a fatigue life less than 10,000 cycles.

42 ENGINEERING↗

The GBS code for tokamak scrape-off layer simulations

We describe a new version of GBS, a 3D global, flux-driven plasma turbulence code to simulate the turbulent dynamics in the tokamak scrape-off layer (SOL), superseding the code presented by Ricci et al. (2012) [14]. The present work is driven by the objective of studying SOL turbulent dynamics in medium size tokamaks and beyond with a high-fidelity physics model. We emphasize an intertwining framework of improved physics models and the computational improvements that allow them. The model extensions include neutral atom physics, finite ion temperature, the addition of a closed field line region, and a non-Boussinesq treatment of the polarization drift. GBS has been completely refactored with the introduction of a 3-D Cartesian communicator and a scalable parallel multigrid solver. We report dramatically enhanced parallel scalability, with the possibility of treating electromagnetic fluctuations very efficiently. The method of manufactured solutions as a verification process has been carried out for this new code version, demonstrating the correct implementation of the physical model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linac-based extracranial radiosurgery with Elekta volumetric modulated arc therapy and an anatomy-based treatment planning system: Feasibility and initial experience

We reported our initial experience in using Elekta volumetric modulated arc therapy (VMAT) and an anatomy-based treatment planning system (TPS) for single high-dose radiosurgery (SRS-VMAT) of liver metastases. This study included a cohort of 12 patients treated with a 26-Gy single fraction. Single-arc VMAT plans were generated with Ergo++ TPS. The prescription isodose surface (IDS) was selected to fulfill the 2 following criteria: 95% of planning target volume (PTV) reached 100% of the prescription dose and 99% of PTV reached a minimum of 90% of prescription dose. A 1-mm multileaf collimator (MLC) block margin was added around the PTV. For a comparison of dose distributions with literature data, several conformity indexes (conformity index [CI], conformation number [CN], and gradient index [GI]) were calculated. Treatment efficiency and pretreatment dosimetric verification were assessed. Early clinical data were also reported. Our results reported that target and organ-at-risk objectives were met for all patients. Mean and maximum doses to PTVs were on average 112.9% and 121.5% of prescribed dose, respectively. A very high degree of dose conformity was obtained, with CI, CN, and GI average values equal to 1.29, 0.80, and 3.63, respectively. The beam-on-time was on average 9.3 minutes, i.e., 0.36 min/Gy. The mean number of monitor units was 3162, i.e., 121.6 MU/Gy. Pretreatment verification (3%-3 mm) showed an optimal agreement with calculated values; mean γ value was 0.27 and 98.2% of measured points resulted with γ < 1. With a median follow-up of 16 months complete response was observed in 12/14 (86%) lesions; partial response was observed in 2/14 (14%) lesions. No radiation-induced liver disease (RILD) was observed in any patients as well no duodenal ulceration or esophagitis or gastric hemorrhage. In conclusion, this analysis demonstrated the feasibility and the appropriateness of high-dose single-fraction SRS-VMAT in liver metastases performed with Elekta VMAT and Ergo++ TPS. Preliminary clinical outcomes showed a high rate of local control and minimum incidence of acute toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Explicit modeling of pebble temperature in the porous-media model for pebble-bed reactors

In this study, we developed a multiscale model to include an explicit pebble-temperature model nested in the porous-media model for pebble-bed reactor applications. The multiscale solid-phase energy balance model, including the pebble surface energy balance equation and an explicit modeling of pebble temperature, can predict the macroscopic (pebble bed) and microscopic (pebble) temperature distributions under both steady-state and transient conditions. The proposed multiscale model is solved in a fully coupled manner using the Newton- Krylov method, and therefore iterations between the macroscopic (pebble-bed-scale) and microscopic (pebble- scale) model are avoided. Extensive code verifications, validation, and demonstrations have been performed for this newly developed model. By explicitly modeling pebble temperatures, this new model addresses a major deficiency of the basic porous-media model, which assumes homogeneous solid-phase temperature and is not appropriate for pebble-bed reactor design and safety analyses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coexistence of low and high spin states in La 18 Co 28 Pb 3

The electronic structure and magnetic properties of a newly predicted stable ternary compound La 18 ⁢Co 28 ⁢Pb 3 are studied using electronic structure analysis. The ground state of this compound is ferromagnetic, with three positions of nonequivalent magnetic Co atoms. A strong dependence of magnetic properties on volume shows that this system is situated near the point of magnetic instability. The coexistence of high- and low-spin ferromagnetic states as a function of volume near equilibrium was discovered. A corresponding spin tunneling splitting was estimated. The stability of the theoretically predicted magnetic ground state was tested by varying the Hubbard parameter. The thermal spin fluctuations were added to estimate the paramagnetic moment and a Curie temperature. Finally, the necessity of experimental verification of the obtained results is emphasized.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clinical application of radiophotoluminescent glass dosimeter for dose verification of prostate HDR procedure

High dose rate brachytherapy (HDR-BT) is one of the many modalities for prostate cancer treatment. Due to the nature of HDR-BT, in vivo dosimetry is feasible and can be used to verify consistent dose delivery. In order to validate a dose verification system for HDR-BT prostate cancer treatment, a radiophotoluminescent glass dosimeter (RPLGD) was used and the measurements were compared with those from a thermoluminescent dosimeter. The RPLGD shows many advantages in HDR-BT dose measurement, such as repeatability, stability, and small effective size. These advantages make the RPLGD a superior option for use as a dosimeter in HDR-BT. The results described here show that the difference between the measured dose and the treatment planned dose is less than 5%. A Monte Carlo simulation for the dose was performed using Monte Carlo N -particle to investigate position error. This study concludes that the RPLGD is a promising and reliable dosimeter for HDR-BT in vivo dosimetry with clinically acceptable accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Pressurized Oxy-Combustion with Flameless Reactor

Pressurized OxyECombustion is one of the most promising technologies for utility-scale power generation plants. Benefits include the ability to burn low rank coal and capture CO 2 . By increasing the flue gas pressure during this process, greater efficiencies are derived from increased quantity and quality of thermal energy recovery. UPA with modeling support from MIT and testing and data verification by Georgia Tech’s Research Center designed and built a 100 kW system capable of demonstrating pressurized oxyEcombustion using a flameless combustor. Wyoming PRB coal was run at 15 and 32 bar. Additional tests were not completed but sampled data demonstrated the viability of the technology over a broader range of operating pressures, Modeling results illustrated a flat efficiency curve over 20 bar, with optimum efficiency achieved at 29 bar. This resulted in a 33% (HHV) efficiency, a 5 points increase in efficiency versus atmospheric oxy-combustion, and a competitive cost of electricity plus greater CO 2 avoidance costs then prior study’s presented. UPA’s operation of the bench-scale system provided evidence that key performance targets were achieved: flue gas sampled at the combustor outlet had non-detectable residual fly ashes, and low levels of SO3 and heavy-metal. These results correspond to prior pressurized oxy-combustion testing completed by IteaEEnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nek5000 developments in support of industry and the NRC

This year, the Nuclear Energy Advanced Modeling Simulation program (NEAMS) thermal-hydraulics verification and validation (V&V) work has focused in three areas of Nek5000 V&V-driven development. First, in a close collaborative effort with the U. S. Nuclear Regulatory Commission (NRC) staff, we have continued V&V efforts for the HYMERES-2 project using the OECD/NEA sponsored testing in the PSI PANDA facility. This year’s focus of ANL-NRC collaboration involves Nek5000 setups and validation for a range of problems relevant to and including the HYMERES-2 benchmark from PSI. The primary outcome of this year efforts is a more efficient geometry and inlet modeling simplification after a careful sensitivity study of the inlet profiles and pipe geometries. The resulting modeling choice of a short recycling/fully-developed turbulent inlet is within the experimental uncertainty estimate. This finding simplifies the next step of the cross-V&V HYMERES-2 project. In addition, the ANL team continue to provide assistance to the NRC staff in the form of Nek5000 application support in general and on the use of the HPC platforms of ALCF and INL in particular. This supports the NRC’s assessment of Nek5000 for use with the NRC Blue CRAB code suite. Second, we have implemented and tested more robust model of URANS, namely the k – τ model, a variant of the k-ω model, along with other improvements to RANS Nek5000 modeling in general. Because of its demonstrated robustness and stability, the k – τ model is the only RANS model that has been implemented in the new GPU version of the Nek5000 code, nekRS. Lastly, we report the initial implementation of Jacobian-free Newton Krylov approach to the direct Newton method for steady fluid solvers aimed at acceleration of RANS modeling and at IC improvement for LES campaigns. Also leveraging the Exascale Computing Project (ECP) ANL/CEED & SMR team’s software development effort to support NEAMS problems at large scale of the advanced computing architectures, NekRS, a GPU variant of Nek5000, built on top of kernels from libParanumal using OCCA for portability, has been successfully run on the full system of Summit (4608 nodes, 27648 GPUs).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental measurement of the effective contact angle for solvent/packing interactions in a structured packed column for CO 2 capture

The contact angle is a critical factor for determining the effective mass transfer area for carbon dioxide (CO 2 ) capture via the chemical absorption process in a packed column, and thus the overall capture efficiency of the packed column. Many widely used commercial packings involve microscale features (perforation, corrugation, etc.) that may also affect the wetting behavior. This study proposes a systematic method of using a modified Wilhelmy plate to measure the effective contact angle to characterize the solvent and featured packing interaction. In lieu of computational efforts relying on assumptions guided by semi-informed correlation, the proposed method directly measures the effective contact angle as a function of the solvent and packing thermophysical and hydrodynamic properties. The characterization of the effective contact angle is then integrated in the computational fluid dynamics modeling to reduce uncertainty in the prediction of effective mas transfer area. Experiments were conducted for stainless steel coupons using water and aqueous sodium hydroxide (NaOH) solvent for verification of the proposed experimental protocol. The surface tension of the aqueous NaOH solvent was altered using surfactant and antifoam. The effective contact angle increases with the increased value of the surface tension for flat stainless steel sheets. On the other hand, effective contact angles do not vary in Mellapak coupons for aqueous monoethanolamine (MEA) and NaOH solvent. In this case, surface textures and sheet design play a dominant role in the surface tension of solvents. Furthermore, CO 2 loading has a significant effect on the contact angle for Mellapak coupons. As expected, the contact angle decreases with the increasing temperature of CO 2 capture solvents (MEA, EEMPA). The effective contact angle measurement using the Wilhelmy plate method can provide more accurate and efficient solvents for characterizing the solvent-packing surface interactions. Subsequently, the present method enhances the accuracy of the prediction of the effective mass transfer area in carbon capture by solvent absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The IAEA Coordinated Research Program on HTGR Reactor Physics, Thermal-hydraulics and Depletion Uncertainty Analysis: Description of the Benchmark Test Cases and Phases

The continued development of High Temperature Gas Cooled Reactors (HTGRs) requires verification of design and safety features with reliable high fidelity physics models and robust, efficient, and accurate codes. The uncertainties in the HTR analysis tools are today typically assessed with sensitivity analysis and then a few important input uncertainties (typically based on a PIRT process) are varied in the analysis to find a spread in the parameter of importance. However, one wish to apply a more fundamental approach to determine the predictive capability and accuracies of coupled neutronics/thermal-hydraulics and depletion simulations used for reactor design and safety assessment. Today there is a broader acceptance of the use of uncertainty analysis even in safety studies and it has been accepted by regulators in some cases to replace the traditional conservative analysis. Finally, there is also a renewed focus in supplying reliable covariance data (nuclear data uncertainties) that can then be used in uncertainty methods. Uncertainty and sensitivity studies are therefore becoming an essential component of any significant effort in data and simulation improvement. In order to address uncertainty in analysis and methods in the HTGR community the IAEA launched a Coordinated Research Project (CRP) on the HTGR Uncertainty Analysis in Modelling early in 2012. The project is built on the experience of the OECD/NEA Light Water Reactor (LWR) Uncertainty Analysis in Best-Estimate Modelling (UAM) benchmark activity, but focuses specifically on the peculiarities of HTGR designs and its simulation requirements. Two benchmark problems were defined with the prismatic type design represented by the MHTGR-350 design from General Atomics (GA) while a 250 MW modular pebble bed design, similar to the INET (China) and indirect-cycle PBMR (South Africa) designs are also included. In the paper more detail on the benchmark cases, the different specific phases and tasks and the latest status and plans are presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A REDUCED ORDER MODELING APPROACH TO PROBABILISTIC CREEP-DAMAGE PREDICTIONS IN FINITE ELEMENT ANALYSIS

This paper introduces a computationally efficient Reduced Order Modeling (ROM) approach for the probabilistic prediction of creep-damage failure. Component-level probabilistic simulations are needed to assess the reliability and safety of high-temperature components. Full-scale probabilistic creep-damage modeling in finite element (FE) approach is computationally expensive requiring many hundreds of simulations to replicate the uncertainty of component failure. To that end, ROM is proposed to minimize the elevated computational cost while controlling the loss of accuracy. It is proposed that full-scale probabilistic simulations can be completed in 1D at a reduced cost, the extremum conditions extracted, and those conditions applied for lower-cost 2D/3D probabilistic simulations of components that capture the mean and uncertainty of failure. The probabilistic Sine-hyperbolic (Sinh) model is selected which in previous work was calibrated to alloy 304 stainless steel. The Sinh model includes probability density functions (pdfs) for test condition (stress and temperature), initial damage (i.e. microstructure), and material properties uncertainty. The Sinh model is programmed into ANSYS finite element software using the USERCREEP.F material subroutine. First, the Sinh model and FE code are subject to verification and validation to ensure the accuracy of the simulations. Numerous Monte Carlo simulations are executed in a 1D model to generate probabilistic creep deformation, damage, and rupture data. This data is analyzed and the probabilistic parameters corresponding to extreme creep response are extracted. The ROM concept is applied where only the extreme conditions are applied in the 2D probabilistic prediction of a component. The probabilistic predictions between the 1D and 2D geometry is compared to assess ROM for creep. The accuracy of the probabilistic prediction employing the ROM approach will potentially reduce the time and cost of simulating complex engineering systems. Future studies will introduce multi-stage Sinh, stochasticity, and spatial uncertainty for improved prediction.

36 MATERIALS SCIENCE↗

Quantifying Security Threats and Their Potential Impacts: A Case Study

In earlier works, we present a computational infrastructure that allows an analyst to estimate the security of a system in terms of the loss that each stakeholder stands to sustain as a result of security breakdowns. In this paper, we illustrate this infrastructure by means of an e-commerce application.

99 GENERAL AND MISCELLANEOUS↗

Test methodology for validation of multi-frequency models of renewable energy generators using small-signal perturbations

Providing trustworthy and accurate multi-frequency (or harmonic) models for renewable energy generators (REG) is an ongoing challenge for harmonic studies. There have been effective attempts to propose and design a test device to validate the harmonic models, mainly based on shunt current perturbations. However, using additional devices for perturbations is costly for converter-based test sites. This paper provides the test specifications to extend the application of the grid emulators for voltage perturbations and appropriate harmonic model validation. Besides, the effects of the sequence couplings, initial emissions, and power set-points on the test results have been overlooked in the literature. Considering these effects, this paper proposes a generic test methodology to obtain more accurate models in the sequence domain. The experimental verification of the proposed methodology is demonstrated using a 7 MVA grid emulator for testing of a 2 MVA photo-voltaic converter and a 2 MVA Type 3 wind turbine. This way, the test challenges, specifications, and recommendations are presented using the MW-scale experiments on different REGs. Furthermore, the effects of sequence couplings and initial emissions on the calculation results are investigated and compared. The proposed methodology is applicable for harmonic model validation as well as empirical modelling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spray–Wall Interactions in a Small-Bore, Multicylinder Engine Operating With Reactivity-Controlled Compression Ignition

Experimental work on reactivity-controlled compression ignition (RCCI) in a small-bore, multicylinder engine operating on premixed iso-octane, and direct-injected n-heptane has shown an unexpected combustion phasing advance at early injection timings, which has not been observed in large-bore engines operating under RCCI at similar conditions. In this study, computational fluid dynamics (CFD) simulations were performed to investigate whether spray–wall interactions could be responsible for this result. Comparison of the spray penetration, fuel film mass, and in-cylinder visualization of the spray from the CFD results to the experimentally measured combustion phasing and emissions provided compelling evidence of strong fuel impingement at injection timings earlier than -90 crank angle degrees (deg CA) after top dead center (aTDC), and transition from partial to full impingement between -65 and -90 deg CA aTDC. Finally, based on this evidence, explanations for the combustion phasing advance at early injection timings are proposed along with potential verification experiments.

42 ENGINEERING↗

SU-E-T-69: Cloud-Based Monte Carlo Patient-Specific Quality Assurance (QA) Method for Volumetric Modulated Arc Therapy (VMAT)

Purpose: Patient-specific QA for VMAT is incapable of providing full 3D dosimetric information and is labor intensive in the case of severe heterogeneities or small-aperture beams. A cloud-based Monte Carlo dose reconstruction method described here can perform the evaluation in entire 3D space and rapidly reveal the source of discrepancies between measured and planned dose. Methods: This QA technique consists of two integral parts: measurement using a phantom containing array of dosimeters, and a cloud-based voxel Monte Carlo algorithm (cVMC). After a VMAT plan was approved by a physician, a dose verification plan was created and delivered to the phantom using our Varian Trilogy or TrueBeam system. Actual delivery parameters (i.e., dose fraction, gantry angle, and MLC at control points) were extracted from Dynalog or trajectory files. Based on the delivery parameters, the 3D dose distribution in the phantom containing detector were recomputed using Eclipse dose calculation algorithms (AAA and AXB) and cVMC. Comparison and Gamma analysis is then conducted to evaluate the agreement between measured, recomputed, and planned dose distributions. To test the robustness of this method, we examined several representative VMAT treatments. Results: (1) The accuracy of cVMC dose calculation was validated via comparative studies. For cases that succeeded the patient specific QAs using commercial dosimetry systems such as Delta- 4, MAPCheck, and PTW Seven29 array, agreement between cVMC-recomputed, Eclipse-planned and measured doses was obtained with >90% of the points satisfying the 3%-and-3mm gamma index criteria. (2) The cVMC method incorporating Dynalog files was effective to reveal the root causes of the dosimetric discrepancies between Eclipse-planned and measured doses and provide a basis for solutions. Conclusion: The proposed method offers a highly robust and streamlined patient specific QA tool and provides a feasible solution for the rapidly increasing use of VMAT treatments in the clinic.

60 APPLIED LIFE SCIENCES↗