Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Commissioning of Robotic Inspection and Automated Analysis System for Assay of Gas Diffusion Piping - 19500

Robotic, in-pipe, nondestructive assay (NDA) is a revolutionary and important means for measuring, analyzing, and reporting radioactive holdup deposits in enrichment piping. This innovation promises vast advantages for efficiency, safety, and cost savings. Payoff, however, lies in utilization much more than innovation. Crossing that threshold from a technical capability to an everyday tool occurs only after rigorous commissioning, adoption, and infusion. This must meet the highest standard, and there can be no compromise. Certification of a new NDA technology must meet the highest standards for quality, safety, and efficacy. Prior to this work, there was no precedent of procedure and method for certification of a robotic methodology for this purpose. The best of robotics had not certified NDA. The best of NDA had not certified robotics. Hence, a great deal of discovery, resourcefulness, and collaboration contributed to this success. This paper chronicles the first-of-kind chartering, co-development, testing, documentation, and site integration that certified this trailblazing in-pipe, robotic NDA. Commissioning had to demonstrate and certify end-to-end NDA automation from robot traversal to computer analysis to report generation of contaminated process piping at the Portsmouth, Ohio gaseous diffusion facility. This was a rigorous campaign of tests, evaluations, and documentation. Highlights included multiple tests in four elevated pipes exercised the gamut of NDA and robotic capabilities. Each of the four test pipes presented a unique loading of U-235. The tests demonstrated operations in both 30- inch and 42-inch diameter pipes with varying lengths and terminated by a variety of valves and fittings. Tests in a fifth pipe at floor level demonstrated deployment and applicability for pipes at this ground height and robot recognition of another fitting type. All operations, calibration, deployment, auto-reporting, and analysis were handled by Portsmouth site personnel. These tests concluded a series of component-level acceptance tests which certified all constituent technologies and operational features. Test metrics included comparison of reported to ground truth results and assessment of data quality from quality assurance and replicate measurement comparison. Beyond the radiometry associated with any NDA method, this unique commissioning path exercised and evaluated all the robotic features that are intrinsic to automation. These include odometry, geometric modeling, autonomy, remote launch and recovery, and end-to-end data flow. Each of these required verification and certification. These evaluations were first-of-kind for the decommissioning community, requiring innovation and resourcefulness in their own right. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating terrestrial and aquatic processes toward watershed scale modeling of dissolved organic carbon fluxes

Dissolved organic carbon (DOC) is not only a critical component of global and regional carbon budgets, but also an important precursor for carcinogenic disinfection byproducts (DBP) generated during drinking water disinfection process. The lack of process based watershed scale model for carbon cycling has been a limiting factor impeding effective watershed management to control DOC fluxes to source waters. Here, we integrated terrestrial and aquatic carbon processes into the widely tested Soil and Water Assessment Tool (SWAT) watershed model to enable watershed-scale DOC modeling (referred to as SWAT-DOC hereafter). The modifications to SWAT mainly fall into two groups: (1) DOC production in soils and its transport to aquatic environment by different hydrologic processes, and (2) riverine transformation of DOC and their interactions with particular organic carbon (POC), inorganic carbon and algae (floating and bottom). We tested the new SWAT-DOC model in the Cannonsville watershed, which is part of the New York City (NYC) water supply system, using long-term DOC load data (from 1998 to 2012) derived from 1399 DOC samplings. The calibration and verification results indicate that SWAT-DOC achieved satisfactory performance for both streamflow and DOC at daily and monthly temporal scales. The parameter sensitivity analysis indicates that DOC loads in the Cannonsville watershed are controlled by the DOC production in soils and its transport in both terrestrial and aquatic environments. Further model uncertainty analysis indicates high uncertainties associated with peak DOC loads, which are attributed to underestimation of high streamflows. Therefore, future efforts to enhance SWAT-DOC to better represent runoff generation processes hold promise to further improve DOC load simulation. Overall, the wide use of SWAT and the satisfactory performance of SWAT-DOC make it a useful tool for DOC modeling and mitigation at the watershed scale.

Dissolved Organic Carbon, non-point source polluti↗

A brief review of digital image processing

The review is presented with particular reference to Skylab S-192 and Landsat MSS imagery. Attention is given to rectification (calibration) processing with emphasis on geometric correction of image distortions. Image enhancement techniques (e.g., the use of high pass digital filters to eliminate gross shading to allow emphasis of the fine detail) are described along with data analysis and system considerations (software philosophy).

Billingsley, F. C.↗

Satellite applications to a coastal inlet study, Clearwater Beach, Florida

Two sets of LANDSAT magnetic tapes were obtained and displayed on the screen of an IMAGE 100 computer. Spectral analysis was performed to produce various signatures, their extent and location. Subsequent ground truth observations and measurements were gathered by means of hydrographic surveys and low-altitude aerial photography for interpretation and calibration of the LANDSAT data. Finally, a coastal engineering assessment based on the LANDSAT data was made. Recommendations to the City of Clearwater regarding the navigational channel alignment and dredging practice are presented in the light of the inlet stability.

Wang, Y. H.↗

Simultaneous H/1216 A/ and He/584 A/ observations of the interstellar wind by Mariner 10

In late 1973 and early 1974 the Mariner 10 spacecraft performed four roll calibration maneuvers (RCM). The Ultraviolet Spectrometer (UVS) measured the intensity of both He(584 A) and H(1216 A) emissions from interplanetary gas. The data and the observational geometry have been described by Broadfoot and Kumar (1978). Analysis of these 4 sets of observations is extremely important since they are the first simultaneous intensity measurements of H and He emissions free of geocoronal contamination to be recorded in one day, thus precluding significant variations in the solar fluxes.

Ajello, J. M.↗

An analysis of radio interferometry with the block O system

The form and flow of information from signal reception to recorded bits at each station, through cross-correlation, phase-tracking, phase calibration, and bandwidth synthesis, to final observable formation are traced. In this process the data volume is greatly compressed for each observation, from approx. 10 to the 9th power bits on the station tapes to only four final observables: amplitude, delay, phase-delay rate and RF phase. After phase calibration and propagation media calibrations, the final delay observable is shown to be the sum of a geometric delay and a clock synchronization offset.

Thomas, J. B.↗

A high speed data acquisition system for the analysis of velocity, density, and total temperature fluctuations at transonic speeds

The use of a high-speed Dynamic Data Acquisition System (DDAS) to measure simultaneously velocity, density, and total temperature fluctuations is described. The DDAS is used to automate the acquisition of hot-wire calibration data. The data acquisition, data handling, and data reporting techiques used by DDAS are described. Sample data are used to compare results obtained with the DDAS with those obtained from the FM tape and post-test digitization method.

Clukey, Steven J.↗

The size and shape of (2) Pallas from the 1983 occultation of 1 Vulpeculae

The analysis and results of an occultation of the spectroscopic binary star 1 Vulpeculae by the asteroid (2) Pallas, observed from 130 locations, are presented. Combination of solutions from this and previous occultations shows the triaxial shape of Pallas to be elongated, but not severely, with the ratio of the largest to the smallest axes being less than 1.15. The data provide a separation and a position angle of the secondary component of 1 Vulpeculae and indicate that the star's actual parallax is probably near 0.008 arcsec, half of the published value. The analysis gives a calibration of the accuracy and the reaction time corrections for visual observations of asteroidal occultations. The absence of any confirmed secondary extinctions shows that any satellites of Pallas must be rare or small. The photometric observations seem to rule out a substantial cloud of dust surrounding Pallas postulated previously.

Dunham, David W.↗

NLTE analysis of SUMER filament observations on SOHO

The observations of hydrogen Lyman delta, epsilon, six and seven lines are described. These data were acquired by the solar ultraviolet measurement of emitted radiation (SUMER) spectrograph onboard the Solar and Heliospheric Observatory (SOHO). All the spectral lines were calibrated to absolute intensities. The multilevel NLTE code was used to evaluate the theoretical line profiles of the four Lyman lines studied. The line cores of all these lines are good indicators of the temperature structure of the filament. The study showed that the line wings are sensitive to the gas pressure. A steep temperature increase in the prominence-corona transition region seems to be consistent with the observed intensities in the line cores of the Lyman lines.

Heinzel, P.↗

Automated Camera Calibration

Automated Camera Calibration (ACAL) is a computer program that automates the generation of calibration data for camera models used in machine vision systems. Machine vision camera models describe the mapping between points in three-dimensional (3D) space in front of the camera and the corresponding points in two-dimensional (2D) space in the camera s image. Calibrating a camera model requires a set of calibration data containing known 3D-to-2D point correspondences for the given camera system. Generating calibration data typically involves taking images of a calibration target where the 3D locations of the target s fiducial marks are known, and then measuring the 2D locations of the fiducial marks in the images. ACAL automates the analysis of calibration target images and greatly speeds the overall calibration process.

Chen, Siqi↗

Efficacy of FTIR Analysis in Determining CO2 Loading on Diglycolamine

In support of advanced air revitalization technologies to enable human spaceflight beyond low earth orbit, performance studies have been conducted using a liquid amine, Diglycolamine (DGA) between teams at NASA?s Johnson Spaceflight Center (JSC) and Ames Research Center (ARC). Liquid amines have been used in regenerable earth-based systems to remove CO2 from industrial systems as well as for closed-environment air revitalization because they can be regenerated at lower temperatures than solid sorbent systems. As an additional advantage to solid sorbent based systems, liquid sorbents can be cycled between an adsorbing contactor and degassing chamber, thereby reducing system complexity by operation in a continuous loop. In an effort to inform a regeneration system design for micro-gravity applications, ARC has performed a number of tests to characterize the degas mechanics of DGA. In order to accurately measure the amount of CO2 captured or released by the amine, methods such as gravimetric weighing and chemical decomposition are reasonable, however the initial design for a scaled down degas system required analysis on small sample sizes. In order to accomplish CO2 loading measurements with a sample size of approximately 500µL, Fourier-transform infrared spectroscopy (FTIR) was used. Calibration against acid decomposition showed relatively good correlation and test data showed reasonable adherence to expected trends, however more extensive testing should be conducted to fully validate the usage of FTIR to determine CO2 loading on DGA.

Diglycolamine↗

CFD Simulations of the AEDC H3 Arc-Jet Flow: Mach 3.3 Nozzle, Flow Surveys, Wedge Models

This paper reports computational simulations and analysis of tests in a high enthalpy arc-jet facility at Arnold Engineering Development Center. These tests were conducted using wedge models placed in a free jet downstream of a 4.5-inch diameter contoured Mach 3.3 nozzle in the H3 facility. For calibration of test conditions, one wedge calibration plate instrumented with an array of pressure and coaxial thermocouple heat flux gages, one stagnation pressure probe and two null-point heat flux calorimeters were used. The pitot pressure and null-point probe measurements give experimental surveys of the test flow, providing assessment of the flow uniformity and valuable data for flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle, into the test box and over the wedge models, and comparisons with the experimental measurements. Several issues related to testing are considered: test flow characterization, prediction of surface quantities for three wedge models, effects of model shape change and test article recession, and prediction of surface quantities for the test articles with two circular cavities. These simulations take into account non-uniform total enthalpy profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the wedge model flowfields.

Arc-jet testing↗

Constraints on f ( R ) gravity from thermal-Sunyaev-Zel’dovich-effect-selected SPT galaxy clusters and weak lensing mass calibration from DES and HST

We present constraints on the f ( R ) gravity model using a sample of 1005 galaxy clusters in the redshift range 0.25–1.78 that have been selected through the thermal Sunyaev-Zel’dovich effect from South Pole Telescope data and subjected to optical and near-infrared confirmation with the multicomponent matched filter algorithm. We employ weak gravitational lensing mass calibration from the Dark Energy Survey Year 3 data for 688 clusters at z < 0.95 and from the Hubble Space Telescope for 39 clusters with 0.6 < z < 1.7 . Our cluster sample is a powerful probe of f ( R ) gravity, because this model predicts a scale-dependent enhancement in the growth of structure, which impacts the halo mass function (HMF) at cluster mass scales. To account for these modified gravity effects on the HMF, our analysis employs a semianalytical approach calibrated with numerical simulations. Combining calibrated cluster counts with primary cosmic microwave background temperature and polarization anisotropy measurements from the Planck 2018 release, we derive robust constraints on the f ( R ) parameter f R 0 . Our results, log 10 | f R 0 | < − 5.32 at the 95% credible level, are the tightest current constraints on f ( R ) gravity from cosmological scales. This upper limit rules out f ( R ) -like deviations from general relativity that result in more than a ∼ 20 % enhancement of the cluster population on mass scales M 200 c > 3 × 10 14 M ⊙ . Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS↗

Balance Calibration – A Method for Assigning a Direct-Reading Uncertainty to an Electronic Balance.

Paper Title: Balance Calibration – A method for assigning a direct-reading uncertainty to an electronic balance. Intended Audience: Those who calibrate or use electronic balances. Abstract: As a calibration facility, we provide on-site (at the customer’s location) calibrations of electronic balances for customers within our company. In our experience, most of our customers are not using their balance as a comparator, but simply putting an unknown quantity on the balance and reading the displayed mass value. Manufacturer’s specifications for balances typically include specifications such as readability, repeatability, linearity, and sensitivity temperature drift, but what does this all mean when the balance user simply reads the displayed mass value and accepts the reading as the true value? This paper discusses a method for assigning a direct-reading uncertainty to a balance based upon the observed calibration data and the environment where the balance is being used. The method requires input from the customer regarding the environment where the balance is used and encourages discussion with the customer regarding sources of uncertainty and possible means for improvement; the calibration process becomes an educational opportunity for the balance user as well as calibration personnel. This paper will cover the uncertainty analysis applied to the calibration weights used for the field calibration of balances; the uncertainty is calculated over the range of environmental conditions typically encountered in the field and the resulting range of air density. The temperature stability in the area of the balance is discussed with the customer and the temperature range over which the balance calibration is valid is decided upon; the decision is based upon the uncertainty needs of the customer and the desired rigor in monitoring by the customer. Once the environmental limitations are decided, the calibration is performed and the measurement data is entered into a custom spreadsheet. The spreadsheet uses measurement results, along with the manufacturer’s specifications, to assign a direct-read measurement uncertainty to the balance. The fact that the assigned uncertainty is a best-case uncertainty is discussed with the customer; the assigned uncertainty contains no allowance for contributions associated with the unknown weighing sample, such as density, static charges, magnetism, etc. The attendee will learn uncertainty considerations associated with balance calibrations along with one method for assigning an uncertainty to a balance used for non-comparison measurements.

47 OTHER INSTRUMENTATION↗

Calibration of the Diffusivity Predictions of Centipede Using Approximate Bayesian Computation and Applications in Nyx (Engineering Scale) and Xolotl-MARMOT (Meso-Scale) Simulations

Fission gas evolution and release in UO 2 nuclear fuel are important fuel performance metrics and occur in several distinct stages: 1) nucleation, growth and resolution of intra-granular bubbles, 2) diffusion to grain boundaries and 3) nucleation and growth of bubbles at grain boundaries, which eventually form a connected network (percolation) enabling release of gas from grain boundaries through connections to triple junctions, grain edges or free surfaces. The NE-SciDAC project is developing several computational tools to model this problem, which are connected in a hierarchical multi-scale framework. The information transfer in the multi-scale framework is a critical step that, in addition to best-estimates, should include uncertainty quantification. Despite taking a first-principles multi-scale approach, there is a need to perform parameter calibration to ensure consistency with available experimental data. In the present study, uncertainty quantification (UQ) and parameter calibration is demonstrated for one of the lower length scale codes in the multi-scale framework (Centipede) and then the results, including instances of the propagated uncertainties, are used in other codes within the framework, specifically Nyx and Xolotl-MARMOT. We calibrated the model parameters in Centipede, a computer code used to predict diffusivities of uranium (U) and xenon (Xe) in the context of the simulation of fission gas in uranium oxide (UO 2 ) nuclear fuel. The Centipede code depends on 183 parameters, all of which are subject to uncertainty. The three data sets used in our calibration effort are taken from the literature. This data is available as a set of measurements, including measurement errors. Our goal is to calibrate a statistical model that predicts both the value of the measurement and the uncertainty associated with the measurement. We perform a Bayesian calibration of the model parameters using a dedicated approximate Bayesian computation (ABC) likelihood function. To avoid excessive computational costs, we replace the expensive Centipede simulation code by a higher-order surrogate model, constructed using only the 9 most important parameters. These important parameters are identified by a preliminary global sensitivity analysis (GSA) study. Among the important parameters are T0 (the temperature at which UO 2 is perfectly stoichiometric) and Hf_pO2 (the temperature dependence of the oxygen (O) partial pressure) that should be considered as operating conditions to be estimated along with the other parameters. We consider two different cases: one where we define one set of these operating conditions for all data sets, and one where we define distinct operating condition parameters for each data set. The Xe diffusivities predicted by the latter case show distinct features that could not be observed in the former. Next, we use the diffusivity predictions by Centipede as input to Nyx, a reduced order fuel performance code focused on gas behavior alone, in order to estimate quantities associated with inter-granular bubble formation at conditions specified by the experiments. Finally, the diffusivities obtained from the calibrated Centipede runs were used in coupled Xolotl-MARMOT simulations of intra- and inter-granular gas evolution. The results are compared to simulations using the baseline diffusivities from Turnbull et al.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advances in Westinghouse fuel rod design technology (PAD5)

The Westinghouse Performance Analysis and Design (PAD) code for light-water reactors has been recently updated to version PAD5 and submitted to NRC for review. PAD5 incorporates extensive updates in fuel performance and material property models, including fuel thermal conductivity, pellet fragment relocation, fission gas release, fission gas swelling, and cladding creep and growth. Advances in thermal models are mainly in pellet fragment relocation, radial power distribution within the pellet, and the changes in fuel thermal conductivity due to changes in temperature, burnup and fuel porosity. The PAD5 thermal fission gas release model is a phenomenological model based on the irradiation dependence of the gas release from mechanistic processes for the diffusion of the fission gas generated in the fuel grains to the grain boundaries, formation of fission gas bubbles on the grain boundaries and release of the fission gas when these grain boundary bubbles inter-link. The PAD5 cladding creep model is predominantly a combination of the following mechanisms: thermal creep, irradiation induced creep, and irradiation enhanced creep. The fuel performance database used for the development, calibration and testing of the PAD5 code covers a broad range of both commercial irradiation data and test rod data and requires continuously additional data focusing on the latest development of the PAD5 code. Test programs are also included in the database. These data are checked and stored in a hierarchical database structure that supports the automation of model development and calibration. New data, once incorporated into the database, can be quickly evaluated with respect to key fuel and cladding performance models to confirm expected trends or to evaluate potential model improvements. This automated calibration system has been integrated with state-of-the-art optimization packages in DAKOTA Analysis Kit to provide for advanced statistical assessments and model coefficient optimization. Calibration results are automatically tabulated and plotted to provide easy assessment of trends or new behaviors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Altitude Measurements of Radiance at High Spectral and Spatial Resolution for SIMBIOS Sensor Calibration, Validation, and Intercomparisons

The successful combination of data from different ocean color sensors depends on the correct interpretation of signal from each of these sensors. Ideally, the sensor measured signals are calibrated to geophysical units of spectral radiance, and sensor artifacts are removed and corrected. The calibration process resamples the signal into a common radiometric data space so that subsequent ocean color algorithms that are applied to the data are based on physical processes and are inherently sensor independent. The objective of this project is to calibrate and validate the on-orbit radiometric characteristics of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) with underflights of NASA's calibrated Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This objective is feasible because AVIRIS measures the same spectral range as SeaWIFS at higher spectral resolution. In addition to satellite sensor underflights, the AVIRIS project has supported comparison and analysis of the radiometric calibration standards used for AVIRIS and SeaWIFS. To date, both the OCTS and SeaWIFS satellite sensors have been underflown by AVIRIS with matching spectral, spatial, geometric, radiometric, and temporal domains. The calibration and validation objective of this project is pursued for the following reasons: (1) Calibration is essential for the quantitative use of SeaWIFS and other SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) sensor data; (2) Calibration in the laboratory of spaceborne sensors is challenging; (3) Satellite sensors are subjected aging on the ground and to trauma during launch; (4) The Earth orbit environment is significantly different than the laboratory calibration environment; (5) Through years of effort AVIRIS has been demonstrated to be well calibrated; and (6) AVIRIS can match the spectral and spatial observation characteristics near the top of the atmosphere at the time of SeaWIFS measurements.

Green, Robert O.↗

Toward a Coherent Detailed Evaluation of Aerosol Data Products from Multiple Satellite Sensors

Atmospheric aerosols represent one of the greatest uncertainties in climate research. Although satellite-based aerosol retrieval has practically become routine, especially during the last decade, there is often disagreement between similar aerosol parameters retrieved from different sensors, leaving users confused as to which sensors to trust for answering important science questions about the distribution, properties, and impacts of aerosols. As long as there is no consensus and the inconsistencies are not well characterized and understood, there will be no way of developing reliable climate data records from satellite aerosol measurements. Fortunately, the most globally representative well-calibrated ground-based aerosol measurements corresponding to the satellite-retrieved products are available from the Aerosol Robotic Network (AERONET). To adequately utilize the advantages offered by this vital resource, an online Multi-sensor Aerosol Products Sampling System (MAPSS) was recently developed. The aim of MAPSS is to facilitate detailed comparative analysis of satellite aerosol measurements from different sensors (Terra-MODIS, Aqua-MODIS, TerraMISR, Aura-OMI, Parasol-POLDER, and Calipso-CALIOP) based on the collocation of these data products over AERONET stations. In this presentation, we will describe the strategy of the MA~SS system, its potential advantages for the aerosol community, and the preliminary results of an integrated comparative uncertainly analysis of aerosol products from multiple satellite sensors.

Ichoku, Charles↗