Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Multipoint Design and Optimization of a Turboshaft Engine for a Tiltwing Turboelectric Vertical Takeoff Landing Air Taxi

This paper describes the design of a turboshaft engine for a tiltwing air taxi application. In this case, the tiltwing air taxi is intended to fly a 400 nm mission with up to fifteen passengers. Engine requirements for the concept engine are taken from aircraft system studies where thrust is produced by four propellers driven by electric motors and powered by a single gas turbine engine. The purpose of this paper is to perform a cycle design optimization that minimizes fuel consumption and weight while respecting current technology limitations to meet mission requirements. To achieve results, the engine overall pressure ratio and maximum temperature at the exit of the combustor are set as the design parameters. Several sensitivity studies are also performed to visualize optimization trends. Results of the optimization study show solutions are heavily dependent on engine cooling flow requirements and exact mission requirements. This engine is intended for use in large system optimization research.

gas turbine↗

Multi-Point Design and Optimization of a Turboshaft Engine for a Tiltwing Turboelectric VTOL Air Taxi

This paper describes the design of a turboshaft engine for a tiltwing air taxi application. In this case, the tiltwing air taxi is intended to fly a 400-nautical mile mission with up to fifteen passengers. Engine requirements for the concept engine are taken from aircraft system studies where thrust is produced by four propellers driven by electric motors and powered by a single gas turbine engine. The purpose of this paper is to perform a cycle design optimization that minimizes fuel consumption and weight while respecting current technology limitations to meet mission requirements. To achieve results, the engine overall pressure ratio and maximum temperature at the exit of the combustor are set as the design parameters. Several sensitivity studies are also performed to visualize optimization trends. Results of the optimization study show solutions are heavily dependent on engine cooling flow requirements and exact mission requirements. This engine is intended for use in large system optimization research.

Optimization↗

Lattice strain effects on the optical properties of MoS 2 nanosheets

‘‘Strain engineering’’ in functional materials has been widely explored to tailor the physical properties of electronic materials and improve their electrical and/or optical properties. Here, we exploit both in plane and out of plane uniaxial tensile strains in MoS 2 to modulate its band gap and engineer its optical properties. We utilize X-ray diffraction and cross-sectional transmission electron microscopy to quantify the strains in the as-synthesized MoS 2 nanosheets and apply measured shifts of Raman-active modes to confirm lattice strain modification of both the out-of-plane and in-plane phonon vibrations of the MoS 2 nanosheets. The induced band gap evolution due to in-plane and out-of-plane tensile stresses is validated by photoluminescence (PL) measurements, promising a potential route for unprecedented manipulation of the physical, electrical and optical properties of MoS 2 .

36 MATERIALS SCIENCE↗

Sustainable Energy Solutions Task 1.0: Networked Monitoring and Control of Small Interconnected Wind Energy Systems

This report presents accomplishments, results, and future work for one task of five in the Wichita State University Sustainable Energy Solutions Project: To develop a scale model laboratory distribution system for research into questions that arise from networked control and monitoring of low-wind energy systems connected to the AC distribution system. The lab models developed under this task are located in the Electric Power Quality Lab in the Engineering Research Building on the Wichita State University campus. The lab system consists of four parts: 1. A doubly-fed induction generator 2. A wind turbine emulator 3. A solar photovoltaic emulator, with battery energy storage 4. Distribution transformers, lines, and other components, and wireless and wired communications and control These lab elements will be interconnected and will function together to form a complete testbed for distributed resource monitoring and control strategies and smart grid applications testing. Development of the lab system will continue beyond this project.

17 WIND ENERGY↗

Overview of Non-nuclear Testing of the Safe, Affordable 30-kW Fission Engine, Including End-to-End Demonstrator Testing

Successful development of space fission systems will require an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. At the power levels under consideration (3-300 kW electric power), almost all technical issues are thermal or stress related and will not be strongly affected by the radiation environment. These issues can be resolved more thoroughly, less expensively, and in a more timely fashing with nonnuclear testing, provided it is prototypic of the system in question. This approach was used for the safe, affordable fission engine test article development program and accomplished viz cooperative efforts with Department of Energy labs, industry, universiites, and other NASA centers. This Technical Memorandum covers the analysis, testing, and data reduction of a 30-kW simulated reactor as well as an end-to-end demonstrator, including a power conversion system and an electric propulsion engine, the first of its kind in the United States.

VanDyke, M. K.↗

Comparison of amplification via the acousto-electric effect of Rayleigh and Leaky-SAW modes in a monolithic surface InP:InGaAs/lithium niobate heterostructure

This work demonstrates a monolithic surface acoustic wave amplifier fabricated by state-of-the-art heterogenous integration of a III-V InGaAs-based epitaxial material stack and LiNbO 3 . We compare amplification of Raleigh-SAW and leaky-SAW modes on a on Y-cut, X-propagating delay line amplifier. Due to the superior properties of the materials employed, we observe a net terminal gain of 3dB for an LSAW overtone mode This platform enables further advances in active and non-reciprocal piezoelectric acoustic devices.

42 ENGINEERING↗

Plasma-assisted deposition and characterization of Al 2 O 3 dielectric layers on (001) β -Ga 2 O 3

In this work, we have investigated plasma-assisted deposition of Al 2 O 3 on HVPE (001) β-Ga 2 O 3 and evaluated the dielectric quality from electrical measurements on fabricated metal-oxide-semiconductor (MOS) capacitors. The interface structure and crystallinity of the films were investigated as a function of the growth temperature. The dielectric/semiconductor interfaces were found to have reverse breakdown electric fields up to 5.3 MV/cm in the β-Ga 2 O 3 , with relatively low hysteresis in capacitance–voltage and low leakage current. We determined a negative fixed interface charge density at the interface from analysis of thickness-dependent capacitance voltage data. In conclusion, this study shows the advantage of using plasma-assisted deposition to achieve high breakdown strength Al 2 O 3 /β-Ga 2 O 3 MOS structures for device application purposes.

42 ENGINEERING↗

Effects of fiber dosage, loading orientation and stress on frequency response of enhanced Carbon Nano-Fiber Aggregates

Nanomaterial additives have been broadly used in cement and concrete-based sensors to measure the stress and strain in the structure. Most of the studies focused on measuring the resistivity of sensors with Direct Current (DC) or relatively low-frequency. Here in this work, the impedance responses of enhanced Carbon Nano-Fiber Aggregates (CNFAs) at different frequencies are rigorously studied and utilized as a tool for real-time structural health monitoring (SHM). The CNFA impedance measurements at different measurement frequencies provide an extra dimension (frequency dimension) to allow the characterization of different phenomena and multimodal measurements simultaneously. First, a comprehensive physical model is established to understand the frequency responses of the CNFA impedance. Second, COMSOL Multiphysics is used to simulate the frequency responses of the CNFA impedance, which provides more insights into the electric field and current density distribution. The impedance of CNFAs decreased with the increased dosage of carbon nanofibers (CNFs). Third, experimental studies are reported in detail. The electrical impedance variation (EZV) of the CNFA in parallel orientation is 151% higher than that of perpendicular orientation at the frequency of 2612 Hz and uniaxial compression stress of 4.65 MPa. The strain-EZV curve obtained from the response spectrum is linear for frequencies ranging from 98 Hz to 463.9 kHz. The strain-EZV curve for 5625 Hz has a linear fit with the gauge factor of 147.78. At 1000 Hz, the CNFA exhibited a repeatable behavior up to 9.35 MPa and detection limit up to the stress of 18.62 MPa.

36 MATERIALS SCIENCE↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Low-Voltage Switchgear Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for low-voltage metal enclosed switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers experiments performed on two low-voltage switchgear units with each unit consisting of two vertical sections. The data collected supports characterization of the low-voltage HEAF hazard and these results will be used to support potential improvements in fire probabilistic risk assessment (PRA) methods. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 26 and Augsut 29, 2019 on nearidentical Westinghouse Type DS low-voltage metal-enclosed indoor switchgear. The threephase arcing fault was initiated on the aluminum main bus or in select cases on the copper bus stabs near the breaker. These experiments used either nominal 480 volts AC or 600 volts AC. Durations of the experiments ranged from approximately 0.4 s to 8.3 s with fault currents ranging from approximately 9.2 kA to 19.3 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. Environmental measurements of breakdown, conductivity and electromagnetics were also taken. The experiments were documented with normal and high-speed videography, infrared imaging and photography. The results, while limited, indicated the difficulty in maintaining and sustaining low-voltage arcs on aluminum components of sufficient duration and at a single point as observed operating experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computationally Efficient AC Resistance Model for Stator Winding With Rectangular Conductors

The resistance of the electric machine’s windings is an important parameter when analyzing the machine’s performance, as conduction losses in the winding are often the largest loss component. However, this resistance changes with frequency due to the skin and proximity effects, making it challenging to accurately estimate these losses. In this article, a computationally efficient, general method of calculating the ac resistance of an electric machine winding with rectangular conductors is presented. The method uses a 1-D magnetoquasi-static model of the stator slot region to develop boundary transfer relations between individual turns. These relations are then used to create an impedance matrix from which the ac resistance can be calculated. This technique is more flexible than previous solutions since it can accommodate different winding configurations such as fractional-pitch windings. It is shown that a fractional-pitch winding has a lower ac resistance than a full-pitch winding. Finally, finite-element analysis simulations and experimental results are used to validate the proposed method.

42 ENGINEERING↗

RELAP5-3D modelling of the HTTR-GT/H 2 secondary system and turbomachinery

High Temperature Gas-cooled Reactors (HTGRs) can be used for the cogeneration of electricity and hydrogen. The JAEA-operated High-Temperature engineering Test Reactor (HTTR-GT/H 2 ) is exploring using the reactor for electricity and hydrogen production. Here, a RELAP5-3D model of the HTTR-GT/H 2 secondary system has been developed using design information. The various components and heat exchangers in the secondary system were investigated, modified, and improved where applicable. With these changes made, the model was run, and the results were compared to the design conditions. The results for the sole-power generation mode were shown to fit the design conditions very well. The largest temperature difference was on the order of 7 K, and the largest pressure difference was on the order of 0.05 MPa. The results for the hydrogen cogeneration mode did not fit the design conditions as well as the other case. The largest temperature difference was about 39 K and the largest pressure difference was about 0.27 MPa at the compressor outlet. The larger differences for the hydrogen cogeneration mode are attributed to the various complex components and the flow being split in the secondary loop. A transient reduction in heat removal capability of the secondary system was investigated. Reactor temperatures were predicted to rise as a result. The core reactivity response due to this increase in temperature is investigated and is expected to add negative reactivity to the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electric-Discharge Machining of Polymer Composites

The electric-discharge machining (EDM) of VKU-29 composite is experimentally studied. The influence of the machining conditions on the lateral electrode gap (the difference between the width of the slot in the polymer composite produced by EDM and the width of the tool electrode) is determined. The electrode gap observed in the machining of VKU-29 composite is analogous to that observed in the machining of steel workpieces. It depends on the pulse energy. Comparison of graphite, copper, and composite tool electrodes shows that the best surface quality is obtained in the latter case. In EDM by a composite electrode, no traces of damage or fluffing are seen on the machined surface.

42 ENGINEERING↗

Report on High Energy Arcing Fault Experiments

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena for medium voltage electrical switchgear containing aluminum conductors. This report covers full-scale laboratory experiments using representative nuclear power plant (NPP) three-phase electrical equipment. Electrical, thermal, and pressure data were recorded for each experiment and documented in this report. This report covers four of the fourteen planned medium voltage electrical enclosure experiments. Subsequent reports will document the additional experiments performed in the future. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the United States Nuclear Regulatory Commission (NRC), the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setups and execution. The HEAF experiments were performed on four near-identical units of General Electric metal-clad medium voltage switchgear. The three-phase arcing fault was initiated on the primary cable connection bus. All four experiments used the same system voltage (6.9 kV) but varied the current and duration. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers and slug calorimeters at various locations around the electrical enclosures. Internal enclosure pressures were measured during the experiments. The experiments were documented with normal and high-speed videography, infrared imaging, and photography. Insights from the experimental series included timing information related to enclosure breach, event progression, mass loss measurements for electrodes and steel enclosures, peak pressure rise, particle analysis, along with visual and thermal imaging data to better understand and characterize the hazard. These results will be used in subsequent efforts to advance the state of knowledge related to HEAF.

42 ENGINEERING↗

Comparison of Spherical Antennas Fabricated via Conformal Printing: Helix, Meanderline, and Hybrid Designs

The design tradeoffs between three spherically conformal electric monopoles-the spherical helix (SH), spherical meanderline (SM), and a hybrid design-are explored through both simulation and measurement. We show that the SH is efficient, but can be difficult to impedance match without external components. On the other hand, the SM antenna has a widely controllable impedance with slightly increased loss. Thus, a hybrid design is proposed that retains the desirable qualities of both the SH and SM. All three designs are fabricated using a conformal printing technique for comparison. Here, we describe the design tradeoffs and physical insights gained through evaluating the efficiency, Q , and matching behavior of these antennas.

42 ENGINEERING↗

Multi-level, forming and filament free, bulk switching trilayer RRAM for neuromorphic computing at the edge

CMOS-RRAM integration holds great promise for low energy and high throughput neuromorphic computing. However, most RRAM technologies relying on filamentary switching suffer from variations and noise, leading to computational accuracy loss, increased energy consumption, and overhead by expensive program and verify schemes. We developed a filament-free, bulk switching RRAM technology to address these challenges. We systematically engineered a trilayer metal-oxide stack and investigated the switching characteristics of RRAM with varying thicknesses and oxygen vacancy distributions to achieve reliable bulk switching without any filament formation. We demonstrated bulk switching at megaohm regime with high current nonlinearity, up to 100 levels without compliance current. We developed a neuromorphic compute-in-memory platform and showcased edge computing by implementing a spiking neural network for an autonomous navigation/racing task. Our work addresses challenges posed by existing RRAM technologies and paves the way for neuromorphic computing at the edge under strict size, weight, and power constraints.

97 MATHEMATICS AND COMPUTING↗

Heavy-Duty Stoichiometric Compression Ignition Engine with Improved Fuel Economy over Alternative Technologies for Meeting 2010 On-Highway Emission

The objectives of the reported work were: to apply the stoichiometric compression ignition (SCI) concept to a 9.0 liter diesel engine; to obtain engine-out NO{sub x} and PM exhaust emissions so that the engine can meet 2010 on-highway emission standards by applying a three-way catalyst for NO{sub x} control and a particulate filter for PM control; and to simulate an optimize the engine and air system to approach 50% thermal efficiency using variable valve actuation and electric turbo compounding. The work demonstrated that an advanced diesel engine can be operated at stoichiometric conditions with reasonable particulate and NOx emissions at full power and peak torque conditions; calculated that the SCI engine will operate at 42% brake thermal efficiency without advanced hardware, turbocompounding, or waste heat recovery; and determined that EGR is not necessary for this advanced concept engine, and this greatly simplifies the concept.

33 ADVANCED PROPULSION SYSTEMS↗

EV Everywhere Grand Challenge Road to Success

Initial progress report for EV Everywhere. The report highlights the significant cost reduction in batteries in 2014, which will enable increased PEV affordability for consumers. Also, the efforts on increasing the convenience of PEVs through the Workplace Charging Challenge, which called on U.S. employers to help develop the nation's charging infrastructure.

33 ADVANCED PROPULSION SYSTEMS↗

Single-event burnout in homojunction GaN vertical PiN diodes with hybrid edge termination design

GaN devices play a major role in modern electronics, providing high-power handling, efficient high-frequency operation, and resilience in harsh environments. However, electric field crowding at the edge of the anode often limits its full potential, leading to single-event effects (SEEs) at lower bias voltages under heavy ion radiation. Here, in this work, we report on the performance of homojunction GaN vertical PiN diodes with a hybrid edge termination design under heavy ion irradiation, specifically, oxygen ions, chlorine ions, Cf-252 fission fragments, and alpha particles from an Am-241 source. The unique hybrid edge termination (HET) design provides better electric field management, preventing breakdown from occurring at the edge of the anode at lower voltages. The results of this study reveal that these devices exhibit excellent tolerance to 12-MeV oxygen and 16-MeV chlorine ions, owing to their low linear energy transfer (LET) and range in GaN. However, single-event burnout (SEB) is observed during the Cf-252 exposure at about 50% of the diodes' electrical breakdown voltage due to the presence of higher LET and longer-range ions. Optical and scanning electron microscopy (SEM) reveal that the damage that caused by SEB lies close to the center of these devices rather than the anode edge. Devices with junction termination extension (JTE) instead of HET edge termination also show similar SEB when irradiated with Cf-252 fission fragments. Physical damage due to SEB occurs at the edge of the anode for these devices. These comparative results show the benefits of HET for enhancing the resistance of GaN-based PiN diodes to heavy ion irradiation.

42 ENGINEERING↗