Search NASA⌕ Search

SEARCH · Search NASA

Results for “error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Resistive wall mode feedback control in EXTRAP T2R with improved steady-state error and transient response

Experiments in the EXTRAP T2R reversed field pinch [P. R. Brunsell, H. Bergsa ring ker, M. Cecconello et al., Plasma Phys. Control. Fusion 43, 1457 (2001)] on feedback control of m=1 resistive wall modes (RWMs) are compared with simulations using the cylindrical linear magnetohydrodynamic model, including the dynamics of the active coils and power amplifiers. Stabilization of the main RWMs (n=-11,-10,-9,-8,+5,+6) is shown using modest loop gains of the order G{approx}1. However, other marginally unstable RWMs (n=-2,-1,+1,+2) driven by external field errors are only partially canceled at these gains. The experimental system stability limit is confirmed by simulations showing that the latency of the digital controller {approx}50 {mu}s is degrading the system gain margin. The transient response is improved with a proportional-plus-derivative controller, and steady-state error is improved with a proportional-plus-integral controller. Suppression of all modes is obtained at high gain G{approx}10 using a proportional-plus-integral-plus-derivative controller.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic Errors of MiniBooNE

Modern neutrino oscillation experiments use a 'near to far' ratio to observe oscillation; many systematic errors cancel in a ratio between the near detector's unoscillated event sample and the far detector's oscillated one. Similarly, MiniBooNE uses a {nu}{sub e} to {nu}{sub {mu}} ratio, which reduces any common uncertainty in both samples. Here, we discuss the systematic errors of MiniBooNE and how the {nu}{sub {mu}} sample constrains the {nu}{sub e} signal sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Possible Tool for Checking Errors in the INAA Results, Based on Neutron Data and Method Validation

This work presents preliminary results of a new type of possible application in the INAA experiments of elemental analysis, useful to check errors occurred during investigation of unknown samples; it relies on the INAA method validation experiments and accuracy of the neutron data from the literature. The paper comprises 2 sections, the first one presents--in short--the steps of the experimental tests carried out for INAA method validation and for establishing the 'ACTIVA-N' laboratory performance, which is-at the same time-an illustration of the laboratory evolution on the way to get performance. Section 2 presents our recent INAA results on CRMs, of which interpretation opens discussions about the usefulness of using a tool for checking possible errors, different from the usual statistical procedures. The questionable aspects and the requirements to develop a practical checking tool are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A statistical analysis of systematic errors in temperature and ram velocity estimates from satellite-borne retarding potential analyzers

The use of biased grids as energy filters for charged particles is common in satellite-borne instruments such as a planar retarding potential analyzer (RPA). Planar RPAs are currently flown on missions such as the Communications/Navigation Outage Forecast System and the Defense Meteorological Satellites Program to obtain estimates of geophysical parameters including ion velocity and temperature. It has been shown previously that the use of biased grids in such instruments creates a nonuniform potential in the grid plane, which leads to inherent errors in the inferred parameters. A simulation of ion interactions with various configurations of biased grids has been developed using a commercial finite-element analysis software package. Using a statistical approach, the simulation calculates collected flux from Maxwellian ion distributions with three-dimensional drift relative to the instrument. Perturbations in the performance of flight instrumentation relative to expectations from the idealized RPA flux equation are discussed. Both single grid and dual-grid systems are modeled to investigate design considerations. Relative errors in the inferred parameters for each geometry are characterized as functions of ion temperature and drift velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of the Johann error for spherically bent x-ray imaging crystal spectrometers

New x-ray imaging crystal spectrometers, currently operating on Alcator C-Mod, NSTX, EAST, and KSTAR, record spectral lines of highly charged ions, such as Ar{sup 16+}, from multiple sightlines to obtain profiles of ion temperature and of toroidal plasma rotation velocity from Doppler measurements. In the present work, we describe a new data analysis routine, which accounts for the specific geometry of the sightlines of a curved-crystal spectrometer and includes corrections for the Johann error to facilitate the tomographic inversion. Such corrections are important to distinguish velocity induced Doppler shifts from instrumental line shifts caused by the Johann error. The importance of this correction is demonstrated using data from Alcator C-Mod.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination and correction of distortions and systematic errors in low-energy electron diffraction

We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volumetric apparatus for hydrogen adsorption and diffusion measurements: Sources of systematic error and impact of their experimental resolutions

The development of a volumetric apparatus (also known as a Sieverts’ apparatus) for accurate and reliable hydrogen adsorption measurement is shown. The instrument minimizes the sources of systematic errors which are mainly due to inner volume calibration, stability and uniformity of the temperatures, precise evaluation of the skeletal volume of the measured samples, and thermodynamical properties of the gas species. A series of hardware and software solutions were designed and introduced in the apparatus, which we will indicate as f-PcT, in order to deal with these aspects. The results are represented in terms of an accurate evaluation of the equilibrium and dynamical characteristics of the molecular hydrogen adsorption on two well-known porous media. The contribution of each experimental solution to the error propagation of the adsorbed moles is assessed. The developed volumetric apparatus for gas storage capacity measurements allows an accurate evaluation over a 4 order-of-magnitude pressure range (from 1 kPa to 8 MPa) and in temperatures ranging between 77 K and 470 K. The acquired results are in good agreement with the values reported in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Communication: Fixed-node errors in quantum Monte Carlo: Interplay of electron density and node nonlinearities

We elucidate the origin of large differences (two-fold or more) in the fixed-node errors between the first- vs second-row systems for single-configuration trial wave functions in quantum Monte Carlo calculations. This significant difference in the valence fixed-node biases is studied across a set of atoms, molecules, and also Si, C solid crystals. We show that the key features which affect the fixed-node errors are the differences in electron density and the degree of node nonlinearity. The findings reveal how the accuracy of the quantum Monte Carlo varies across a variety of systems, provide new perspectives on the origins of the fixed-node biases in calculations of molecular and condensed systems, and carry implications for pseudopotential constructions for heavy elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The importance of matched poloidal spectra to error field correction in DIII-D

Optimal error field correction (EFC) is thought to be achieved when coupling to the least-stable “dominant” mode of the plasma is nulled at each toroidal mode number (n). The limit of this picture is tested in the DIII-D tokamak by applying superpositions of in- and ex-vessel coil set n = 1 fields calculated to be fully orthogonal to the n = 1 dominant mode. In co-rotating H-mode and low-density Ohmic scenarios, the plasma is found to be, respectively, 7× and 20× less sensitive to the orthogonal field as compared to the in-vessel coil set field. For the scenarios investigated, any geometry of EFC coil can thus recover a strong majority of the detrimental effect introduced by the n = 1 error field. Despite low sensitivity to the orthogonal field, its optimization in H-mode is shown to be consistent with minimizing the neoclassical toroidal viscosity torque and not the higher-order n = 1 mode coupling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positivity, discontinuity, finite resources, and nonzero error for arbitrarily varying quantum channels

This work is motivated by a quite general question: Under which circumstances are the capacities of information transmission systems continuous? The research is explicitly carried out on finite arbitrarily varying quantum channels (AVQCs). We give an explicit example that answers the recent question whether the transmission of messages over AVQCs can benefit from assistance by distribution of randomness between the legitimate sender and receiver in the affirmative. The specific class of channels introduced in that example is then extended to show that the unassisted capacity does have discontinuity points, while it is known that the randomness-assisted capacity is always continuous in the channel. We characterize the discontinuity points and prove that the unassisted capacity is always continuous around its positivity points. After having established shared randomness as an important resource, we quantify the interplay between the distribution of finite amounts of randomness between the legitimate sender and receiver, the (nonzero) probability of a decoding error with respect to the average error criterion and the number of messages that can be sent over a finite number of channel uses. We relate our results to the entanglement transmission capacities of finite AVQCs, where the role of shared randomness is not yet well understood, and give a new sufficient criterion for the entanglement transmission capacity with randomness assistance to vanish.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-parameter error analysis method based on rotating coordinates in rotating birefringent polarizer system

We propose error analysis using a rotating coordinate system with three parameters of linearly polarized light—incidence angle, azimuth angle on the front surface, and angle between the incidence and vibration planes—and demonstrate the method on a rotating birefringent prism system. The transmittance and angles are calculated plane-by-plane using a birefringence ellipsoid model and the final transmitted intensity equation is deduced. The effects of oblique incidence, light interference, beam convergence, and misalignment of the rotation and prism axes are discussed. We simulate the entire error model using MATLAB and conduct experiments based on a built polarimeter. The simulation and experimental results are consistent and demonstrate the rationality and validity of this method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty of Rotating Shadowband Irradiometers and Si-Pyranometers Including the Spectral Irradiance Error

Concentrating solar power projects require accurate direct normal irradiance (DNI) data including uncertainty specifications for plant layout and cost calculations. Ground measured data are necessary to obtain the required level of accuracy and are often obtained with Rotating Shadowband Irradiometers (RSI) that use photodiode pyranometers and correction functions to account for systematic effects. The uncertainty of Si-pyranometers has been investigated, but so far basically empirical studies were published or decisive uncertainty influences had to be estimated based on experience in analytical studies. One of the most crucial estimated influences is the spectral irradiance error because Si-photodiode-pyranometers only detect visible and color infrared radiation and have a spectral response that varies strongly within this wavelength interval. Furthermore, analytic studies did not discuss the role of correction functions and the uncertainty introduced by imperfect shading. In order to further improve the bankability of RSI and Si-pyranometer data, a detailed uncertainty analysis following the Guide to the Expression of Uncertainty in Measurement (GUM) has been carried out. The study defines a method for the derivation of the spectral error and spectral uncertainties and presents quantitative values of the spectral and overall uncertainties. Data from the PSA station in southern Spain was selected for the analysis. Average standard uncertainties for corrected 10 min data of 2% for global horizontal irradiance (GHI), and 2.9% for DNI (for GHI and DNI over 300 W/m2) were found for the 2012 yearly dataset when separate GHI and DHI calibration constants were used. Also the uncertainty in 1 min resolution was analyzed. The effect of correction functions is significant. The uncertainties found in this study are consistent with results of previous empirical studies.

14 SOLAR ENERGY↗

Comparison of Optical Modelling Tools for Sunshape and Surface Slope Error

The sunshape and mirror surface slope error are two main factors that influence the characteristics of incoming and reflected solar beams in a solar concentrator. Different optical modelling tools, however, address these two factors with different methods and simplifications. In this study, simulation methods are reviewed in five optical modelling tools, namely SolTrace, Tonatiuh, Tracer, Heliosim and SolarPILOT. A series of simple test cases are simulated in each tool to compare and verify the implementation of sunshape and slope error models separately. This strategy has successfully identified discrepancies among the tools and contributed to a better understanding of their reasons. It has also uncovered few glitches in some of those tools and contributed to improve them. It is our hope that this study will help to resolve common misconceptions, to build confidence amongst CSP researches on the accuracy of tools with which they have less experience, and to ensure better agreement in optical modelling work in future.

14 SOLAR ENERGY↗

Quantum cryptography: individual eavesdropping with the knowledge of the error-correcting protocol

The quantum key distribution protocol BB84 combined with the repetition protocol for error correction is analysed from the point of view of its security against individual eavesdropping relying on quantum memory. It is shown that the mere knowledge of the error-correcting protocol changes the optimal attack and provides the eavesdropper with additional information on the distributed key. (fifth seminar in memory of d.n. klyshko)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Error statistics in a high-speed fibreoptic communication line with a phase shift of odd bits

The propagation of optical pulses through a fibreoptic communication line with a phase shift of odd bits is directly numerically simulated. It is shown that simple analytic expressions approximate well the error probability. The phase shift of odd bits in the initial sequence is statistically shown to decrease significantly the error probability in the communication line. (fibreoptic communication lines)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of the effect of noise parameters of a 3D lidar on the error in estimating relief signatures of distant objects from 2D field intensity distributions of reflected radiation

We consider the influence of noise parameters of a 3D lidar and external background radiation on the error in estimating the relief signatures of distant objects from 2D field intensity distributions of the reflected radiation. A physical and mathematical model is developed to analyse the effect of noise. The dependence of the error in estimating the relief signatures at various signal-to-noise ratios is investigated taking into account the parameters of real multi-element photodetectors (MEPDs). The obtained results indicate the possibility of evaluating relief signatures of distant objects with high accuracy based on standard MEPDs simultaneously for a large number of points on the object’s surface with a signal-to-noise ratio of more than 4. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Case study: Accounting for response measurement error in fitting a regression model

This article presents a case study motivated by a plot of data that suggested an emerging trend that the authors were faced with explaining. When the measurement error of the data is accounted for, it turns out there was no real trend. Furthermore, this article shows how to use a Bayesian modeling approach to account for the measurement error.

42 ENGINEERING↗

The spectral basis of optimal error field correction on DIII-D

Here, experimental optimum error field correction (EFC) currents found in a wide breadth of dedicated experiments on DIII-D are shown to be consistent with the currents required to null the poloidal harmonics of the vacuum field which drive the kink mode near the plasma edge. This allows the identification of empirical metrics which predict optimal EFC currents with accuracy comparable to that of first- principles modeling which includes the ideal plasma response. While further metric refinements are desirable, this work suggests optimal EFC currents can be effectively fed-forward based purely on knowledge of the vacuum error field and basic equilibrium properties which are routinely calculated in real-time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗