Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Correlation of anomalous write error rates and ferromagnetic resonance spectrum in spin-transfer-torque-magnetic-random-access-memory devices containing in-plane free layers

In a small fraction of magnetic-tunnel-junction-based magnetic random-access memory devices with in-plane free layers, the write-error rates (WERs) are higher than expected on the basis of the macrospin or quasi-uniform magnetization reversal models. In devices with increased WERs, the product of effective resistance and area, tunneling magnetoresistance, and coercivity do not deviate from typical device properties. However, the field-swept, spin-torque, ferromagnetic resonance (FS-ST-FMR) spectra with an applied DC bias current deviate significantly for such devices. With a DC bias of 300 mV (producing 9.9 × 10{sup 6} A/cm{sup 2}) or greater, these anomalous devices show an increase in the fraction of the power present in FS-ST-FMR modes corresponding to higher-order excitations of the free-layer magnetization. As much as 70% of the power is contained in higher-order modes compared to ≈20% in typical devices. Additionally, a shift in the uniform-mode resonant field that is correlated with the magnitude of the WER anomaly is detected at DC biases greater than 300 mV. These differences in the anomalous devices indicate a change in the micromagnetic resonant mode structure at high applied bias.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digitizing Today’s Buildings in the Real World: Lessons from Field Demonstrations

Digital twins, created by generating a virtual replica of a building, enable safe evaluation of operational scenarios and applications like fault detection and diagnosis and advanced controls. However, a prerequisite is the creation of a machine-readable digital representation of a building, currently hindered by fragmented information scattered across mechanical drawings, point lists, and natural language sequences. As a result, digital twin development remains labor-intensive, error-prone, and difficult to validate. To address these challenges, two efforts from ASHRAE aim to support the digitalization of buildings. ASHRAE s223 establishes a semantic model of buildings, representing system components, configuration, and data sources. ASHRAE s231 defines a vendor-neutral programming language for expressing their control logic. As the industry evaluates implementing them in their products, understanding the challenges that vendors and implementers may face is crucial. In this paper, we present findings and lessons learned from field demonstrations in five buildings that implemented control applications using ASHRAE s223 and s231. The demonstrations highlight how semantic modeling and formalized control descriptions can significantly reduce software development time, manual point mapping, and hard-coding. Beyond time efficiency, they enable reliable automation by minimizing human interpretation and providing a means for consistency across projects. We describe the processes and best practices for model creation and model usage, from translating heterogeneous building documentation into semantic representations to implementing control logic in real-world systems. Finally, we discuss the challenges that persist, including integration with legacy software environments, gaps in interoperability, and the level of expertise still required to effectively leverage semantic models.

Prakash, Anand Krishnan↗

MO-D-213-05: Sensitivity of Routine IMRT QA Metrics to Couch and Collimator Rotations

Purpose: To assess the sensitivity of gamma index and other IMRT QA metrics to couch and collimator rotations. Methods: Two brain IMRT plans with couch and/or collimator rotations in one or more of the fields were evaluated using the IBA MatriXX ion chamber array and its associated software (OmniPro-I’mRT). The plans were subjected to routine QA by 1) Creating a composite planar dose in the treatment planning system (TPS) with the couch/collimator rotations and 2) Creating the planar dose after “zeroing” the rotations. Plan deliveries to MatriXX were performed with all rotations set to zero on a Varian 21ex linear accelerator. This in effect created TPS-created planar doses with an induced rotation error. Point dose measurements for the delivered plans were also performed in a solid water phantom. Results: The IMRT QA of the plans with couch and collimator rotations showed clear discrepancies in the planar dose and 2D dose profile overlays. The gamma analysis, however, did pass with the criteria of 3%/3mm (for 95% of the points), albeit with a lower percentage pass rate, when one or two of the fields had a rotation. Similar results were obtained with tighter criteria of 2%/2mm. Other QA metrics such as percentage difference or distance-to-agreement (DTA) histograms produced similar results. The point dose measurements did not obviously indicate the error due to location of dose measurement (on the central axis) and the size of the ion chamber used (0.6 cc). Conclusion: Relying on Gamma analysis, percentage difference, or DTA to determine the passing of an IMRT QA may miss critical errors in the plan delivery due to couch/collimator rotations. A combination of analyses for composite QA plans, or per-beam analysis, would detect these errors.

60 APPLIED LIFE SCIENCES↗

Acceleration of diffusive molecular dynamics simulations through mean field approximation and subcycling time integration

Highlights: • Two numerical methods are presented to accelerate DMD simulations. • The methods greatly reduce the computation time without much loss of accuracy. • The accelerated DMD model is capable of simulating long-term mass transport at atomistic length scales. • Demonstrated for the propagation of an atomically sharp phase boundary over 30 seconds. - Abstract: Diffusive Molecular Dynamics (DMD) is a class of recently developed computational models for the simulation of long-term diffusive mass transport at atomistic length scales. Compared to previous atomistic models, e.g., transition state theory based accelerated molecular dynamics, DMD allows the use of larger time-step sizes, but has a higher computational complexity at each time-step due to the need to solve a nonlinear optimization problem at every time-step. This paper presents two numerical methods to accelerate DMD based simulations. First, we show that when a many-body potential function, e.g., embedded atom method (EAM), is employed, the cost of DMD is dominated by the computation of the mean of the potential function and its derivatives, which are high-dimensional random variables. To reduce the cost, we explore both first- and second-order mean field approximations. Specifically, we show that the first-order approximation, which uses a point estimate to calculate the mean, can reduce the cost by two to three orders of magnitude, but may introduce relatively large error in the solution. We show that adding an approximate second-order correction term can significantly reduce the error without much increase in computational cost. Second, we show that DMD can be significantly accelerated through subcycling time integration, as the cost of integrating the empirical diffusion equation is much lower than that of the optimization solver. To assess the DMD model and the numerical approximation methods, we present two groups of numerical experiments that simulate the diffusion of hydrogen in palladium nanoparticles. In particular, we show that the computational framework is capable of capturing the propagation of an atomically sharp phase boundary over a time window of more than 30 seconds. The effects of the proposed numerical methods on solution accuracy and computation time are also assessed quantitatively.

36 MATERIALS SCIENCE↗

Investigation of high-precision Λ hypernuclear spectroscopy via the (e,e'K + ) reaction

The study of Λ hypernuclear structure is very interesting in point of the understanding of the interaction between Λ and nucleon (Λ-N interaction) and its strange structure itself due to the containment of a Λ hyperon which has a strangeness as a new degree of freedom. In the several way to study the Lamda hypernuclei, the (e,e&#x27;K + ) reaction spectroscopy is a powerful tool for the precise investigation of Λ hypernuclear structure. The purpose of the preset thesis is the establishment of the experimental design with the efficient data analysis method for the (e,e&#x27;K + ) hypernuclear spectroscopic experiment in the wide mass region (from A=7 to A=52). It is very challenging to perform the (e,e&#x27;K + ) spectroscopic experiment with such a heavy target, because of the huge electron background due to the bremsstrahlung process. In the experiment, it is required to obtain the necessary hypernuclear yield, suppressing the background event ratio. We achieved these requirements by newly constructing the high resolution electron spectrometer (HES) and splitter magnet (SPL) dedicated to the (e,e&#x27;K + ) spectroscopic experiment. The HES consists of two quadrupole magnets and a dipole magnets (Q-Q-D) with a momentum resolution of dp/p = 3x10 -4 at p = 0.84 GeV/c. It was used being vertically tilted by 6.5 degree so as to optimize signal to noise ratio and hypernuclear yield. The SPL is a dipole magnet. The experimental target was placed at the entrance of this magnet. The role of the SPL is to separate four kind of particles; scattered kaons, photons created by the bremsstrahlung, the post beam and scattered electrons. In addition, since the SPL is a part of the kaon and electron spectrometers. We designed the magnet shape carefully considering these points. The experiment was performed with 2.344 GeV/c electron beam from CEBAF at Jefferson Lab. The experimental setup consists of the HES, SPL and HKS (high momentum resolution kaon spectrometer). The HKS is also a Q-Q-D type spectrometer with the momentum resolution of dp/p = 2x10 -4 at p = 1.2 GeV/c. In the data analysis, the particle momentum calibration was the most important procedure. At the initial point, the particle momentum was obtained from the calculated magnetic field map of the spectrometer whose accuracy is an order of 10 -2 . The initial momentum was calibrated by two step, the the magnetic field map improvement and the calibration with known masses of Λ/σ 0 which were observed by the CH 2 target data. As a result of the calibration, the momentum resolutions of HKS and HES were estimated as 4x10 -4 and 6x10 -4 , respectively. Though these values are the double of the designed value, it was achieved to obtain the Λ/σ 0 peaks with the same order of the designed energy from the original calculated magnetic field. The cross section was calculated with the several estimated factors. The averaged p(γ*, K + )Λ cross section in the HKS acceptance, (0.90 < cos(θ^CM_K + ) < 1.0) was calculated as 227 ± 12 ±26 [nb/sr], which is consistent within the error bar with the other experiment results of p(γ, K + )Λ. The obtained yield of the peak was almost same as the designed value with the considered detector efficiencies. The observed hypernuclear spectrum of 12 Λ B was also consistent with the other experimental results. These analysis result represents that the experimental setup including the newly constructed HES and SPL worked and the calibration procedure of this unique experimental setup is basically established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real space iterative reconstruction for vector tomography (RESIRE-V)

Tomography has had an important impact on the physical, biological, and medical sciences. To date, most tomographic applications have been focused on 3D scalar reconstructions. However, in some crucial applications, vector tomography is required to reconstruct 3D vector fields such as the electric and magnetic fields. Over the years, several vector tomography methods have been developed. Here, we present the mathematical foundation and algorithmic implementation of REal Space Iterative REconstruction for Vector tomography, termed RESIRE-V. RESIRE-V uses multiple tilt series of projections and iterates between the projections and a 3D reconstruction. Each iteration consists of a forward step using the Radon transform and a backward step using its transpose, then updates the object via gradient descent. Incorporating with a 3D support constraint, the algorithm iteratively minimizes an error metric, defined as the difference between the measured and calculated projections. The algorithm can also be used to refine the tilt angles and further improve the 3D reconstruction. To validate RESIRE-V, we first apply it to a simulated data set of the 3D magnetization vector field, consisting of two orthogonal tilt series, each with a missing wedge. Our quantitative analysis shows that the three components of the reconstructed magnetization vector field agree well with the ground-truth counterparts. We then use RESIRE-V to reconstruct the 3D magnetization vector field of a ferromagnetic meta-lattice consisting of three tilt series. Our 3D vector reconstruction reveals the existence of topological magnetic defects with positive and negative charges. We expect that RESIRE-V can be incorporated into different imaging modalities as a general vector tomography method. To make the algorithm accessible to a broad user community, we have made our RESIRE-V MATLAB source codes and the data freely available at https://github.com/minhpham0309/RESIRE-V.

47 OTHER INSTRUMENTATION↗

SU-E-J-30: Benchmark Image-Based TCP Calculation for Evaluation of PTV Margins for Lung SBRT Patients

Purpose: Tumor control probability (TCP) calculated with accumulated radiation doses may help design appropriate treatment margins. Image registration errors, however, may compromise the calculated TCP. The purpose of this study is to develop benchmark CT images to quantify registration-induced errors in the accumulated doses and their corresponding TCP. Methods: 4DCT images were registered from end-inhale (EI) to end-exhale (EE) using a “demons” algorithm. The demons DVFs were corrected by an FEM model to get realistic deformation fields. The FEM DVFs were used to warp the EI images to create the FEM-simulated images. The two images combined with the FEM DVF formed a benchmark model. Maximum intensity projection (MIP) images, created from the EI and simulated images, were used to develop IMRT plans. Two plans with 3 and 5 mm margins were developed for each patient. With these plans, radiation doses were recalculated on the simulated images and warped back to the EI images using the FEM DVFs to get the accumulated doses. The Elastix software was used to register the FEM-simulated images to the EI images. TCPs calculated with the Elastix-accumulated doses were compared with those generated by the FEM to get the TCP error of the Elastix registrations. Results: For six lung patients, the mean Elastix registration error ranged from 0.93 to 1.98 mm. Their relative dose errors in PTV were between 0.28% and 6.8% for 3mm margin plans, and between 0.29% and 6.3% for 5mm-margin plans. As the PTV margin reduced from 5 to 3 mm, the mean TCP error of the Elastix-reconstructed doses increased from 2.0% to 2.9%, and the mean NTCP errors decreased from 1.2% to 1.1%. Conclusion: Patient-specific benchmark images can be used to evaluate the impact of registration errors on the computed TCPs, and may help select appropriate PTV margins for lung SBRT patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-339: Dosimetric Verification of Acuros XB Dose Calculation Algorithm On An Air Cavity for 6-MV Flattening Filter-Free Beam

Purpose: This study was to verify the accuracy of Acuros XB (AXB) dose calculation algorithm on an air cavity for a single radiation field using 6-MV flattening filter-free (FFF) beam. Methods: A rectangular slab phantom containing an air cavity was made for this study. The CT images of the phantom for dose calculation were scanned with and without film at measurement depths (4.5, 5.5, 6.5 and 7.5 cm). The central axis doses (CADs) and the off-axis doses (OADs) were measured by film and calculated with Analytical Anisotropic Algorithm (AAA) and AXB for field sizes ranging from 2 Χ 2 to 5 Χ 5 cm{sup 2} of 6-MV FFF beams. Both algorithms were divided into AXB-w and AAA -w when included the film in phantom for dose calculation, and AXB-w/o and AAA-w/o in calculation without film. The calculated OADs for both algorithms were compared with the measured OADs and difference values were determined using root means squares error (RMSE) and gamma evaluation. Results: The percentage differences (%Diffs) between the measured and calculated CAD for AXB-w was most agreement than others. Compared to the %Diff with and without film, the %Diffs with film were decreased than without within both algorithms. The %Diffs for both algorithms were reduced with increasing field size and increased relative to the depth increment. RMSEs of CAD for AXB-w were within 10.32% for both inner-profile and penumbra, while the corresponding values of AAA-w appeared to 96.50%. Conclusion: This study demonstrated that the dose calculation with AXB within air cavity shows more accurate than with AAA compared to the measured dose. Furthermore, we found that the AXB-w was superior to AXB-w/o in this region when compared against the measurements.

60 APPLIED LIFE SCIENCES↗

Influence of inhomogeneous stochasticity on the falsifiability of mean-field theories and examples from accretion disc modelling

ABSTRACT Despite spatial and temporal fluctuations in turbulent astrophysical systems, mean-field theories can be used to describe their secular evolution. However, observations taken over time scales much shorter than dynamical time scales capture a system in a single state of its turbulence ensemble. Comparing with mean-field theory can falsify the latter only if the theory is additionally supplied with a quantified precision. The central limit theorem provides appropriate estimates to the precision only when fluctuations contribute linearly to an observable and with constant coherent scales. Here, we introduce an error propagation formula that relaxes both limitations, allowing for non-linear functional forms of observables and inhomogeneous coherent scales and amplitudes of fluctuations. The method is exemplified in the context of accretion disc theories, where inhomogeneous fluctuations in the surface temperature are propagated to the disc emission spectrum – the latter being a non-linear and non-local function of the former. The derived precision depends non-monotonically on emission frequency. Using the same method, we investigate how binned spectral fluctuations in telescope data change with the spectral resolving power. We discuss the broader implications for falsifiability of a mean-field theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward a Generalizable Prediction Model of Molten Salt Mixture Density with Chemistry‐Informed Transfer Learning

Optimally designing applications of molten salts requires knowledge of their thermophysical properties over a wide range of temperatures and compositions. There exist significant gaps in existing databases and this data can be challenging to experimentally measure due to high temperatures, salt corrosivity, and salt hygroscopicity. Existing databases have been used to create Redlich–Kister (RK) models for mixture density showing improved accuracy with respect to ideal mixing assumptions, but these models require subcomponent data measurements for each new system, therefore lacking generality. In order to address generalizability and data sparsity, a transfer learning procedure is proposed to train deep neural networks (DNNs) using a combination of semi‐empirical relationships (RK), data from the thermophysical arm of the molten salt thermal properties database and universal ab initio properties of component mixtures taken from the joint automated repository for various integrated simulations (JARVIS) classical force‐field inspired descriptors database to predict density in molten salts. Herein, it is shown that DNNs predict molten salt density with an r 2 over 0.99 and a mean absolute percentage error under 1%, outperforming alternative methods.

inorganic materials↗

Adaptive mesh refinement in stress-constrained topology optimization

We present a topology structural optimization framework with adaptive mesh refinement and stress-constraints. Finite element approximation and geometry representation benefit from such refinement by enabling more accurate stress field predictions and greater resolution of the optimal structural boundaries. We combine a volume fraction filter to impose a minimum design feature size, the RAMP penalization to generate “black-and-white designs” and a RAMP-like stress definition to resolve the “stress singularity problem.” Regions with stress concentrations dominate the optimized design. As such, rigorous simulations are required to accurately approximate the stress field. To achieve this goal, we invoke a threshold operation and mesh refinement during the optimization. We do so in an optimal fashion, by applying adaptive mesh refinement techniques that use error indicators to refine and coarsen the mesh as needed. In this way, we obtain more accurate simulations and greater resolution of the design domain. We present results in two dimensions to demonstrate the efficiency of our method.

97 MATHEMATICS AND COMPUTING↗

Direct Numerical Simulation of Pore-Scale Flow in a Bead Pack: Comparison with Magnetic Resonance Imaging Observations

A significant body of current research is aimed at developing methods for numerical simulation of flow and transport in porous media that explicitly resolve complex pore and solid geometries, and at utilizing such models to study the relationships between fundamental pore-scale processes and macroscopic manifestations at larger (i.e., Darcy) scales. A number of different numerical methods for pore-scale simulation have been developed, and have been extensively tested and validated for simplified geometries. However, validation of pore-scale simulations of fluid velocity for complex, three-dimensional (3D) pore geometries that are representative of natural porous media is challenging due to our limited ability to measure pore-scale velocity in such systems. Recent advances in magnetic resonance imaging (MRI) offer the opportunity to measure not only the pore geometry, but also local fluid velocities under steady-state flow conditions in 3D and with high spatial resolution. In this paper, we present a 3D velocity field measured at sub-pore resolution (tens of micrometers) over a centimeter-scale 3D domain using MRI methods. We have utilized the measured pore geometry to perform 3D simulations of Navier-Stokes flow over the same domain using direct numerical simulation techniques. We present a comparison of the numerical simulation results with the measured velocity field. It is shown that the numerical results match the observed velocity patterns well overall except for a variance and small systematic scaling which can be attributed to the known experimental error in the MRI measurements. The comparisons presented here provide strong validation of the pore-scale simulation methods and new insights for interpretation of uncertainty in MRI measurements of pore-scale velocity. This study also provides a potential benchmark for future comparison of other pore-scale simulation methods.

computational fluid dynamics↗

Studying phonon coherence with a quantum sensor

Nanomechanical oscillators offer numerous advantages for quantum technologies. Their integration with superconducting qubits shows promise for hardware-efficient quantum error-correction protocols involving superpositions of mechanical coherent states. Limitations of this approach include mechanical decoherence processes, particularly two-level system (TLS) defects, which have been widely studied using classical fields and detectors. In this manuscript, we use a superconducting qubit as a quantum sensor to perform phonon number-resolved measurements on a piezoelectrically coupled phononic crystal cavity. This enables a high-resolution study of mechanical dissipation and dephasing in coherent states of variable size ($\overline{n}$ ≃ 1 – 10 phonons). We observe nonexponential relaxation and state size-dependent reduction of the dephasing rate, which we attribute to TLS. Using a numerical model, we reproduce the dissipation signatures (and to a lesser extent, the dephasing signatures) via emission into a small ensemble (N = 5) of rapidly dephasing TLS. Our findings comprise a detailed examination of TLS-induced phonon decoherence in the quantum regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

COSMOGRAIL: the COSmological MOnitoring of GRAvItational Lenses: XVI. Time delays for the quadruply imaged quasar DES J0408–5354 with high-cadence photometric monitoring* [COSMOGRAIL XVI: Time delays for the quadruply imaged quasar DES J0408–5354 with high-cadence photometric monitoring]

Here, we present time-delay measurements for the new quadruple imaged quasar DES J0408–5354, the first quadruple imaged quasar found in the Dark Energy Survey (DES). Our result is made possible by implementing a new observational strategy using almost daily observations with the MPIA 2.2 m telescope at La Silla observatory and deep exposures reaching a signal-to-noise ratio of about 1000 per quasar image. This data qualityallows us to catch small photometric variations (a few mmag rms) of the quasar, acting on temporal scales much shorter than microlensing, and hence making the time delay measurement very robust against microlensing. In only seven months we very accurately measured one of the time delays in DES J0408–5354: Δt(AB) = –112.1 ± 2.1 days (1.8%) using only the MPIA 2.2 m data. In combination with data taken with the 1.2 m Euler Swiss telescope, we also measured two delays involving the D component of the system Δt(AD) = –155.5 ± 12.8 days (8.2%) and Δt(BD) = –42.4 ± 17.6 days (41%), where all the error bars include systematics. Turning these time delays into cosmological constraints will require deep Hubble Space Telescope (HST) imaging or ground-based adaptive optics (AO), and information on the velocity field of the lensing galaxy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPATIALLY RESOLVED STAR FORMATION HISTORY ALONG THE DISK OF M82 USING MULTI-BAND PHOTOMETRIC DATA

We present results on the star formation history and extinction in the disk of M82 over spatial scales of 10'' ({approx}180 pc). Multi-band photometric data covering the far-ultraviolet to the near-infrared bands were fitted to a grid of synthetic spectral energy distributions. We obtained distribution functions of age and extinction for each of the 117 apertures analyzed, taking into account observational errors through Monte Carlo simulations. These distribution functions were fitted with Gaussian functions to obtain the mean ages and extinctions together with their errors. The zones analyzed include the high surface brightness complexes defined by O'Connell and Mangano. We found that these complexes share the same star formation history and extinction as the field stellar populations in the disk. There is an indication that the stellar populations are marginally older at the outer disk (450 Myr at {approx}3 kpc) as compared to the inner disk (100 Myr at 0.5 kpc). For the nuclear region (radius less than 500 pc), we obtained an age of less than 10 Myr. The results obtained in this work are consistent with the idea that the 0.5-3 kpc part of the disk of M82 formed around 90% of the stellar mass in a star-forming episode that started around 450 Myr ago and lasted for about 350 Myr. We found that field stars are the major contributors to the flux over the spatial scales analyzed in this study, with the stellar cluster contribution being 7% in the nucleus and 0.7% in the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

PALM-3000: EXOPLANET ADAPTIVE OPTICS FOR THE 5 m HALE TELESCOPE

We describe and report first results from PALM-3000, the second-generation astronomical adaptive optics (AO) facility for the 5.1 m Hale telescope at Palomar Observatory. PALM-3000 has been engineered for high-contrast imaging and emission spectroscopy of brown dwarfs and large planetary mass bodies at near-infrared wavelengths around bright stars, but also supports general natural guide star use to V ≈ 17. Using its unique 66 × 66 actuator deformable mirror, PALM-3000 has thus far demonstrated residual wavefront errors of 141 nm rms under ∼1'' seeing conditions. PALM-3000 can provide phase conjugation correction over a 6.''4 × 6.''4 working region at λ = 2.2 μm, or full electric field (amplitude and phase) correction over approximately one-half of this field. With optimized back-end instrumentation, PALM-3000 is designed to enable 10{sup –7} contrast at 1'' angular separation, including post-observation speckle suppression processing. While continued optimization of the AO system is ongoing, we have already successfully commissioned five back-end instruments and begun a major exoplanet characterization survey, Project 1640.

79 ASTRONOMY AND ASTROPHYSICS↗

Interstellar flow longitude from the symmetry of the pickup ion cutoff at 1 AU

We provide a proof of concept that the pickup ion (PUI) cutoff speed variation with ecliptic longitude can provide the interstellar neutral (ISN) flow longitude λ{sub ISN∞} outside the heliosphere with a precision of the order of 0.°1. We compare 2007–2014 STEREO A PLASTIC observations in the solar wind frame with a simple analytical cutoff model and perform a Pearson correlation of the cutoff as a function of longitude with those values mirrored about a location λ{sub M} that slides in longitude. The resulting maximum correlation at λ{sub M} = 255.°21 ± 0.°04 reflects the ISN upwind direction with a purely statistical uncertainty. This result is consistent with recent ISN flow longitude values, but a precision determination requires the evaluation of underlying systematic effects. Obtaining a precision ISN flow longitude is highly complementary to the IBEX ISN observations, which return a narrow tube in the ISN parameter space that couples flow speed and longitude tightly, but leaves a substantially larger error bar along the tube. The ISN flow provides one cardinal axis of the heliosphere, with a strong leverage on the plane subtended by the ISN velocity and the interstellar magnetic field vector, which controls the shape of the heliosphere and its interaction with the interstellar medium. In addition, a discussion about potential temporal variations of the ISN flow has started. Both issues require a precision determination of the ISN flow velocity over decade-long time intervals. ACE SWICS, STEREO PLASTIC, and SOHO CTOF PUI data allow such long-term studies over almost two decades.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-433: Field-In-Field Irradiation for Breast Cancer with VERO-4DRT System: A Feasibility Study

Purpose: The Vero-4DRT system is a dedicated system for high precision radiation therapy. However, the field size is limited at 15 cm x 15 cm and shapes by using multi-leaf collimator (MLC) without X-Jaw and Y-Jaw. Therefore VERO-4DRT system is not available to simple wedged irradiation for breast cancer. In this study, we suppose FIF with ring and/or tilt/pan angles whole breast irradiation (FIFWBI). The purpose of this study is to verify the feasibility of FIFWBI with VERO-4DRT system. Methods: As fundamental evaluation, we performed commissioning test with phantom. The absorbed dose evaluation at several reference points and dose distribution including split area were performed. We planned 10 demonstrative shapes in phantom for measuring these contents with i-plan workstation (BrainLAB). As clinical evaluation, the dose distribution and dose indexes were evaluated with actual patient data. Five patients with breast cancer were designed FIFWBI radiotherapy plan with split fields. Then, the dose distribution and dose indexes (including Dmax, Dmin, D95, D5 and Homogeneity index) were evaluated in these plans. Results: As the results of fundamental evaluation, all absorbed dose errors between calculated and measured doses were within 2%. The gamma passing rates with 2 mm/3% criteria in all cases were 96±2%. As the results of clinical evaluation, the values of Dmax, D95, D50, D5, and Homogeneity Index were 41.7±0.90 Gy, 49.4±0.34 Gy, 52.26±0.24 Gy, and 1.39±0.03, respectively. For Japanese breast cancer patients, this technique was feasible. However, the large split region was happened in FIFWBI in case of patient with large breast. Conclusion: We evaluated the FIFWBI technique with VERO-4DRT system. This technique is feasible for Japanese patients, but the patient with large breast should be disagreed with this technique.

60 APPLIED LIFE SCIENCES↗