Search NASA⌕ Search

SEARCH · Search NASA

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Validation of clear-sky fluxes for tropical oceans from the Earth Radiation Budget Experiment

The existence and magnitude of a systematic bias in the clear-sky longwave fluxes from the Earth Radiation Budget Experiment (ERBE) is investigated. The bias is apparently introduced because the ERBE method for scene identification does not account for large zonal gradients in longwave absorption by water vapor. The ERBE fluxes are compared to fluxes calculated with a radiative transfer model from ship radiosonde measurements. The comparison is based upon an analysis of 5 yr of coincident satellite and radiosonde observations for equatorial ocean regions. The differences between the ERBE and model fluxes are examined as functions of sea surface temperature (SST) and relative humidity. The authors use height-mean relative humidity bar-RH as an index of atmospheric moisture. The average offset between and model ERBE fluxes ranges between +2 and +6 W/sq m for SSTs above 295 K, and the gradients with respect to SST are nearly identical. However, the difference between the model and ERBE depends significantly on the tropospheric relative humidity. ERBE fluxes exceed model fluxes for bar-RH above 70%, and the maximum offset of +9 to +12 W/sq m is consistent with previous estimates. There are also indications that the clear-sky fluxes for bar-RH below 25% may be underestimated by about 10-15 W/sq m. Since extreme values of height-mean humidity are relatively infrequent, the net bias introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates introduced in the ERBE monthly mean clear-sky fluxes is generally less than the systematic error in estimates of the instantaneous fluxes. These findings support earlier work on the coupling between SST and the atmospheric greenhouse effect, in particular the existence of a super greenhouse effect for oceans warmer than 300 K. Recent reports of much larger systematic differences are not supported by this analysis. The results indicate that comparison of general circulation model (GCM) and ERBE clear-sky longwave fluxes will depend explicitly on atmospheric humidity.

Collins, W. D.↗

Development of a fully integrated analysis system for ions based on ion-selective optodes and centrifugal microfluidics

A fully integrated, miniaturized analysis system for ions based on a centrifugal microfluidics platform and ion-selective optode membranes is described. The microfluidic architecture is composed of channels, five solution reservoirs, a measuring chamber, and a waste reservoir manufactured onto a disk-shaped substrate of poly(methyl methacrylate). Ion-selective optode membranes, composed of plasticized poly(vinyl chloride) impregnated with an ionophore, a proton chromoionophore, and a lipophilic anionic additive, were cast, with a spin-on device, onto a support layer and then immobilized on the disk. Fluid propulsion is achieved by the centrifugal force that results from spinning the disk, while a system of valves is built onto the disk to control flow. These valves operate based on fluid properties and fluid/substrate interactions and are controlled by the angular frequency of rotation. With this system, we have been able to deliver calibrant solutions, washing buffers, or "test" solutions to the measuring chamber where the optode membrane is located. An analysis system based on a potassium-selective optode has been characterized. Results indicate that optodes immobilized on the platform demonstrate theoretical responses in an absorbance mode of measurement. Samples of unknown concentration can be quantified to within 3% error by fitting the response function for a given optode membrane using an acid (for measuring the signal for a fully protonated chromoionophore), a base (for fully deprotonated chromoionophore), and two standard solutions. Further, the ability to measure ion concentrations by employing one standard solution in conjunction with acid and base and with two standards alone were studied to delineate whether the current architecture could be simplified. Finally, the efficacy of incorporating washing steps into the calibration protocol was investigated.

NASA Discipline Life Sciences Technologies↗

Reaching during virtual rotation: context specific compensations for expected coriolis forces

Subjects who are in an enclosed chamber rotating at constant velocity feel physically stationary but make errors when pointing to targets. Reaching paths and endpoints are deviated in the direction of the transient inertial Coriolis forces generated by their arm movements. By contrast, reaching movements made during natural, voluntary torso rotation seem to be accurate, and subjects are unaware of the Coriolis forces generated by their movements. This pattern suggests that the motor plan for reaching movements uses a representation of body motion to prepare compensations for impending self-generated accelerative loads on the arm. If so, stationary subjects who are experiencing illusory self-rotation should make reaching errors when pointing to a target. These errors should be in the direction opposite the Coriolis accelerations their arm movements would generate if they were actually rotating. To determine whether such compensations exist, we had subjects in four experiments make visually open-loop reaches to targets while they were experiencing compelling illusory self-rotation and displacement induced by rotation of a complex, natural visual scene. The paths and endpoints of their initial reaching movements were significantly displaced leftward during counterclockwise illusory rotary displacement and rightward during clockwise illusory self-displacement. Subjects reached in a curvilinear path to the wrong place. These reaching errors were opposite in direction to the Coriolis forces that would have been generated by their arm movements during actual torso rotation. The magnitude of path curvature and endpoint errors increased as the speed of illusory self-rotation increased. In successive reaches, movement paths became straighter and endpoints more accurate despite the absence of visual error feedback or tactile feedback about target location. When subjects were again presented a stationary scene, their initial reaches were indistinguishable from pre-exposure baseline, indicating a total absence of aftereffects. These experiments demonstrate that the nervous system automatically compensates in a context-specific fashion for the Coriolis forces associated with reaching movements.

Clinical Trial↗

Atmospheric Compensation for Uplink Arrays via Radiometry

Uplink arrays for communications applications are gaining increased visibility within the NASA and military community due to the enhanced flexibility and reliability they provide. When compared with the conventional large, single aperture antennas currently comprising the Deep Space Network (DSN), for example, smaller aperture antenna arrays have the benefits of providing fault tolerance (reduced single-point failure), reduced maintenance cost, and enhanced capabilities such as electronic beam-steering and multi-beam operation. However, signal combining of antenna array elements spaced many wavelengths apart becomes problematic due to the inherent instability of earth's turbulent atmosphere, particularly at the frequencies of interest to the DSN (i.e., Ka-band). Degradation in the power combining of the individual elements comprising the array arises due to uncorrelated phase errors introduced as the signals propagate through the troposphere. It is well known that the fundamental source of this error is due to the inhomogeneous distribution of water vapor in the atmosphere [1]. Several techniques have been proposed to circumvent this issue, including the use of phase calibration towers and a moon bounce to generate a feedback loop which would provide a means of intermittent calibration of the system phase errors (thermal drifts, atmosphere) [2,3]. However, these techniques require repositioning of the antenna elements to perform this operation which ultimately results in reduced system availability. And, though they are sufficient for compensating for slow varying phase drifts, they are insufficient to compensate for faster varying phase errors, such as those introduced by the atmosphere. In this paper, preliminary radiometry and interferometry measurements collected by the NASA Glenn Research Center are analyzed and indicate that the use of optimized water vapor radiometers as a feedback system in a communications platform could provide the necessary atmospheric compensation technique to enhance the beamforming of uplink arrays.

Nessel, James A.↗

Statistical Process Control and Capability Study on the Water Content Measurements in NASA Glenn's Icing Research Tunnel

The Icing Research Tunnel (IRT) at NASA Glenn Research Center follows the recommended practice for icing tunnel calibration outlined in SAE's ARP5905 document. The calibration team has followed the schedule of a full calibration every five years with a check calibration done every six months following. The liquid water content of the IRT has maintained stability within in the specifications presented to customers that the variation is within +/- 10% of the calibrated, target measurement. With recent measurements and instrumentation errors, a more thorough assessment of error source was desired. By constructing statistical process control charts, the ability to determine how the instrument varies in the short term, mid term, and long term was gained. The control charts offer a view of instrument error, facility error, or installation changes. It was discovered that there was a shift from target to mean baseline thus leading to the study of the overall capability indices of the liquid water content measuring instrument to perform within specifications defined in the IRT. This presentation describes data processing procedures for the Multi-Element Sensor in the IRT, including collision efficiency corrections, canonical correlation analysis, Chauvenet's Criterion for rejection of data, distribution check of data, and mean, median and mode for construction of control charts. Further data is presented to describe the repeatability of the IRT with the Multi-Element Sensor and the ability to maintain a stable process for the defined calibration schedule.

Timko, Emily N.↗

Assessment of Mars Atmospheric Temperature Retrievals from the Thermal Emission Spectrometer Radiances

Motivated by the needs of Mars data assimilation. particularly quantification of measurement errors and generation of averaging kernels. we have evaluated atmospheric temperature retrievals from Mars Global Surveyor (MGS) Thermal Emission Spectrometer (TES) radiances. Multiple sets of retrievals have been considered in this study; (1) retrievals available from the Planetary Data System (PDS), (2) retrievals based on variants of the retrieval algorithm used to generate the PDS retrievals, and (3) retrievals produced using the Mars 1-Dimensional Retrieval (M1R) algorithm based on the Optimal Spectral Sampling (OSS ) forward model. The retrieved temperature profiles are compared to the MGS Radio Science (RS) temperature profiles. For the samples tested, the M1R temperature profiles can be made to agree within 2 K with the RS temperature profiles, but only after tuning the prior and error statistics. Use of a global prior that does not take into account the seasonal dependence leads errors of up 6 K. In polar samples. errors relative to the RS temperature profiles are even larger. In these samples, the PDS temperature profiles also exhibit a poor fit with RS temperatures. This fit is worse than reported in previous studies, indicating that the lack of fit is due to a bias correction to TES radiances implemented after 2004. To explain the differences between the PDS and Ml R temperatures, the algorithms are compared directly, with the OSS forward model inserted into the PDS algorithm. Factors such as the filtering parameter, the use of linear versus nonlinear constrained inversion, and the choice of the forward model, are found to contribute heavily to the differences in the temperature profiles retrieved in the polar regions, resulting in uncertainties of up to 6 K. Even outside the poles, changes in the a priori statistics result in different profile shapes which all fit the radiances within the specified error. The importance of the a priori statistics prevents reliable global retrievals based a single a priori and strongly implies that a robust science analysis must instead rely on retrievals employing localized a priori information, for example from an ensemble based data assimilation system such as the Local Ensemble Transform Kalman Filter (LETKF).

Hoffman, Matthew J.↗

Using Laser Altimetry to Detect Topographic Change in Long Valley Caldera, California

Long Valley caldera California, is a site of extensive volcanism, persistent seismicity, and uplift of a resurgent dome, currently at a rate of about 3 cm/year. Airborne laser altimetry was used to determine the surface topography of the region in 1993. A repeat mission occurred in 1995. Three different laser altimeters were flown, dubbed ATLAS, SLICER and RASCAL. Data processing consists of the combination of the aircraft trajectory and attitude data with the laser range, the determination of an atmospheric delay, laser pulse timing errors, laser system biases, and data geolocation to obtain the position of the laser spot on the ground. Results showed that using the ATLAS and SLICER instruments, the elevation of an overflown lake is determined to precisions of 3.3 cm and 2.9 cm from altitudes of 500 m and 3 km above the ground, and about 10 cm using the RASCAL instrument from 500 m above ground. Comparison with tide gauge data showed the laser measurements are able to resolve centimeter-level changes in the lake elevation over time. Repeat pass analysis of tracks over flat surfaces indicate no systematic biases affect the measurement procedure of the ATLAS and SLICER instruments. Comparison of GPS and laser-derived elevations of easily-identifiable features in the caldera confirm the horizontal accuracy of the measurement is within the diameter of the laser footprint, and vertical accuracy is within the error inherent in the measurement. Crossover analysis shows that the standard error of the means at track intersection points within the caldera, and dome (i.e., where zero and close to the maximum amount of uplift is expected) are about I cm, indicating elevation change at the 3 cm/year level should be detectable. We demonstrate one of the powerful advantages of scanning laser altimetry over other remote sensing techniques; the straightforward creation of precise digital elevation maps of overflown terrain. Initial comparison of the 1993-1995 data indicates uplift occurred, but filtering is required to remove vegetation effects. Although research continues to utilize the full potential of laser altimetry data, the results constitute a successful demonstration that the technique may be used to perform geodetic monitoring of surface topographic change.

Hofton, M. A.↗

Using Laser Altimetry to Detect Topographic Change at Long Valley Caldera, California

Long Valley caldera, California, is a site of extensive volcanism, persistent seismicity, and uplift of a resurgent dome, currently at a rate of approximately 3 cm/year. Airborne laser altimetry was used to determine the surface topography of the region in 1993. A repeat mission occurred in 1995. Three different laser altimeters were flown, dubbed ATLAS, SLICER and RASCAL. Data processing consists of the combination of the aircraft trajectory and attitude data with the laser range, the determination of an atmospheric delay, laser pulse timing errors, laser system biases, and data geolocation to obtain the position of the laser spot on the ground. Results showed that using the ATLAS and SLICER instruments, the elevation of an overflown lake is determined to precisions of 3.3 cm and 2.9 cm from altitudes of 500 m and 3 km above the ground, and approximately 10 cm using the RASCAL instrument from 500 m above ground. Comparison with tide gauge data showed the laser measurements are able to resolve centimeter-level changes in the lake elevation over time. Repeat pass analysis of tracks over flat surfaces indicate no systematic biases affect the measurement procedure of the ATLAS and SLICER instruments. Comparison of GPS and laser-derived elevations of easily-identifiable features in the caldera confirm the horizontal accuracy of the measurement is within the diameter of the laser footprint, and vertical accuracy is within the error inherent in the measurement. Crossover analysis shows that the standard error of the means at track intersection points within the caldera and dome (i.e., where zero and close to the maximum amount of uplift is expected) are about 1 cm, indicating elevation change at the 3 cm/year level should be detectable. We demonstrate one of the powerful advantages of scanning laser altimetry over other remote sensing techniques; the straightforward creation of precise digital elevation maps of overflown terrain. Initial comparison of the 1993-1995 data indicates uplift occurred, but filtering is required to remove vegetation effects. Although research continues to utilize the full potential of laser altimetry data, the results constitute a successful demonstration that the technique may be used to perform geodetic monitoring of surface topographic change.

Hofton, M. A.↗

Toward Accurate Modeling of Galaxy Clustering on Small Scales: Constraining the Galaxy-halo Connection with Optimal Statistics

Applying halo models to analyze the small-scale clustering of galaxies is a proven method for characterizing the connection between galaxies and their host halos. Such works are often plagued by systematic errors or limited to clustering statistics that can be predicted analytically. In this work, we employ a numerical mock-based modeling procedure to examine the clustering of Sloan Digital Sky Survey DR7 galaxies. We apply a standard halo occupation distribution (HOD) model to dark matter only simulations with a ΛCDM cosmology. To constrain the theoreStical models, we utilize a combination of galaxy number density and selected scales of the projected correlation function, redshift-space correlation function, group multiplicity function, average group velocity dispersion, mark correlation function, and counts-in-cells statistics. We design an algorithm to choose an optimal combination of measurements that yields tight and accurate constraints on our model parameters. Compared to previous work using fewer clustering statistics, we find a significant improvement in the constraints on all parameters of our halo model for two different luminosity-threshold galaxy samples. Most interestingly, we obtain unprecedented high-precision constraints on the scatter in the relationship between galaxy luminosity and halo mass. However, our best-fit model results in significant tension (>4σ) for both samples, indicating the need to add second-order features to the standard HOD model. To guarantee the robustness of these results, we perform an extensive analysis of the systematic and statistical errors in our modeling procedure, including a first of its kind study of the sensitivity of our constraints to changes in the halo mass function due to baryonic physics.

79 ASTRONOMY AND ASTROPHYSICS↗

Measured and estimated performance of a fleet of shaded photovoltaic systems with string and module-level inverters

Shade obstructions can significantly impact the performance of photovoltaic (PV) systems. Although there are many models for partially shaded PV arrays, there is a lack of information available regarding their accuracy and uncertainty when compared with actual field performance. This work assesses the recorded performance of 46 residential PV systems, equipped with either string-level or module-level inverters, under a variety of shading conditions. We compare their energy production data to annual PV performance predictions, with a focus on the practical models developed here for National Renewable Energy Laboratory's system advisor model software. This includes assessment of shade extent on each PV system by using traditional onsite surveys and newer 3D obstruction modelling. The electrical impact of shade is modelled by either a nonlinear performance model or assumption of linear impact with shade extent, depending on the inverter type. When applied to the fleet of residential PV systems, performance is predicted with median annual bias errors of 2.5% or less, for systems with up to 20% estimated shading loss. The partial shade models are not found to add appreciable uncertainty to annual predictions of energy production for this fleet of systems but do introduce a monthly root-mean-square error of approximately 4%-9% due to seasonal effects. Here the use of a detailed 3D model results in similar or improved accuracy over site survey methods, indicating that, with proper description of shade obstructions, modelling of partially shaded PV arrays can be done completely remotely, potentially saving time and cost.

14 SOLAR ENERGY↗

Integration and Optimization of a Waste Heat Driven Organic Rankine Cycle for Power Generation in Wastewater Treatment Plants

The study focuses on achieving energy self-sufficiency in Wastewater Treatment Plants by proposing a comprehensive model for integrating, sizing, and optimizing an Organic Rankine Cycle system. The Organic Rankine Cycle system is designed to utilize waste heat from the gensets at As Samra Wastewater Treatment Plant in Jordan, where it will contribute to the overall electrical energy supply of the plant. Real data from As Samra Wastewater Treatment Plant is used to model and calculate the available waste heat using TRNSYS® software. The Organic Rankine Cycle model is then developed using ASPEN PLUS® software to explore the impact of operational parameters and determine their optimal values for maximizing the plant's energy profile. An economic analysis is conducted to assess the feasibility of the proposed model, considering system components, installation, operation, and maintenance costs. To optimize the Organic Rankine Cycle system, the study employs the Multi-Output Support Vector Regression technique to capture nonlinear relationships between independent variables (fluid type, turbine inlet pressure, turbine inlet temperature, turbine outlet pressure, and mass flow rate) and dependent variables (pump power input, waste heat input, and turbine specific work). The Osprey optimization algorithm is used to address the multi-objective optimization problem, with the proposed Pareto-based Osprey Optimization Algorithm and the Multi-Objective Particle Swarm Optimization technique being employed to evaluate critical performance and economic parameters such as system thermal efficiency, net power output, and the levelized cost of electricity. The results of the optimization strategies indicate that the M-SVR model's prediction accuracy is significantly improved after parameter optimization, with the model returning high R 2 and low Mean Square Error values of 0.991 and 0.00216, respectively. The Pareto-Based Osprey Optimization Algorithm optimizer identifies the best working fluid as Isobutane/Isopentane in a ratio of 66:34, with optimal turbine inlet pressure and temperature of 15 bars and 218 °C, respectively. In conclusion, the Organic Rankine Cycle model at these optimal conditions achieves a cycle efficiency of 19.93% and an Levelized Cost of Electricity value of 0.0353 USD/kWh.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correlations between Salt-Induced Crystallization, Morphology, Segmental Dynamics, and Conductivity in Amorphous Block Copolymer Electrolytes

Block copolymer electrolytes have been shown to increase the cycle life of rechargeable batteries that utilize high capacity lithium anodes. Most block copolymer electrolyte studies have been centered on polystyrene-b-poly(ethylene oxide) (SEO) mixed with lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) salt and are limited to salt concentrations in the vicinity of r[Li]/[EO] = 0.1, where [Li] and [EO] are the concentration of lithium and ethylene oxide moieties, respectively, as the conductivity of poly(ethylene oxide) (PEO) homopolymer electrolytes is maximized at this concentration.Here, in this paper, we study the morphology and conductivity of electrolytes derived from a high molecular weight SEO block copolymer over the wide LiTFSI concentration range of 0 ≤ r ≤ 0.550. For electrolytes with r ≥ 0.125, the crystallization of PEO-LiTFSI complexes with stoichiometric ratios of 6:1, 3:1, or 2:1 (EO:Li) is shown to correlate with morphology as determined by small-angle X-ray scattering (SAXS) and scanning transmission electron microscopy (STEM): some samples that are semicrystalline at room temperature exhibit regions of periodic lamellar ordering, whereas those that do not crystallize have aperiodic packed-ellipsoid morphologies. SAXS profiles below and above the melting temperatures of the crystals are identical, indicating that the crystals are confined within the block copolymer domains. The conductivities of SEO/LiTFSI mixtures with r = 0.275, r = 0.300, and r = 0.350 are within experimental error of PEO/LiTFSI at the same salt concentrations, in spite of the presence of insulating polystyrene (PS) domains in the SEO/LiTFSI samples. We attribute this to enhanced segmental dynamics of the PEO chains in the SEO electrolytes, based on differential scanning calorimetry (DSC) measurements of glass transition temperatures. The dependence of ionic conductivity on salt concentration in the SEO/LiTFSI electrolytes at temperatures above the melting temperature of the crystalline complexes shows three local maxima that correlate with the formation of crystalline complexes when r ≥ 0.125. Finally, these maxima arise due to a combination of the enhanced segmental dynamics and changes in morphology observed by SAXS and STEM.

36 MATERIALS SCIENCE↗

A new dump system design for stray light reduction of Thomson scattering diagnostic system on EAST

Thomson scattering (TS) diagnostic is an important diagnostic for measuring electron temperature and density during plasma discharge. However, the measurement of Thomson scattering signal is disturbed by the stray light easily. The stray light sources in the Experimental Advanced Superconducting Tokamak (EAST) TS diagnostic system were analyzed by a simulation model of the diagnostic system, and simulation results show that the dump system is the primary stray light source. Based on the optics theory and the simulation analysis, a novel dump system including an improved beam trap was proposed and installed. The measurement results indicate that the new dump system can reduce more than 60% of the stray light for the diagnostic system, and the influence of stray light on the error of measured density decreases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SARAS MEASUREMENT OF THE RADIO BACKGROUND AT LONG WAVELENGTHS

SARAS is a correlation spectrometer connected to a frequency independent antenna that is purpose-designed for precision measurements of the radio background at long wavelengths. The design, calibration, and observing strategies admit solutions for the internal additive contributions to the radiometer response, and hence a separation of these contaminants from the antenna temperature. We present here a wideband measurement of the radio sky spectrum by SARAS that provides an accurate measurement of the absolute brightness and spectral index between 110 and 175 MHz. Accuracy in the measurement of absolute sky brightness is limited by systematic errors of magnitude 1.2%; errors in calibration and in the joint estimation of sky and system model parameters are relatively smaller. We use this wide-angle measurement of the sky brightness using the precision wide-band dipole antenna to provide an improved absolute calibration for the 150 MHz all-sky map of Landecker and Wielebinski: subtracting an offset of 21.4 K and scaling by a factor of 1.05 will reduce the overall offset error to 8 K (from 50 K) and scale error to 0.8% (from 5%). The SARAS measurement of the temperature spectral index is in the range −2.3 to −2.45 in the 110–175 MHz band and indicates that the region toward the Galactic bulge has a relatively flatter index.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvement of the RELAP5-3D Model of Condensation in the Presence of Noncondensables

Condensation of steam on the primary side of a steam generator in a pressurized water reactor (PWR) is one means of removing decay heat during some accident scenarios, including small break loss of coolant accident (SBLOCA). However, when noncondensable gasses mix with steam, it impairs condensation. To correctly predict plant behavior, nuclear power plant (NPP) safety analysis codes such as RELAP5-3D must model the effect of condensation in the presence of noncondensables properly. A potential error in the RELAP5-3D code was reported in the condensation model in the presence of noncondensables by the University of Wisconsin (Fu 2015). The report indicated that the calculated condensation heat flux was under-predicted due to the modeling of the mass transfer in the gas mixture. The original documentation describing the implementation of the model was reviewed and compared with alternative formulations. An alternative that uses saturation vapor density at temperature of total pressure instead of the saturation vapor density at vapor partial pressure for calculating vapor mass flux was implemented. Comparison of the alternative method with the original against experimental data for several test cases showed improvement for most test cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CCSI Toolset 3.22 Release

CCSI Toolset 3.22 Release Highlights The Sequential Design of Experiments user interface was updated to resolve an issue where the results would fail to plot in some cases (e.g., Non-Uniform Space Filling designs). The Machine Learning/Artificial Intelligence module was updated to support Keras 3 and to reflect changes made to dependencies’ syntax. A check was added to ensure PSUADE is installed and available at FOQUS startup. If PSUADE is not installed, a link to the FOQUS documentation is displayed and FOQUS is closed. The copyright year was updated to include 2024 in places where it had not previously been updated. Typographical errors were corrected to improve clarity in variable names and documentation. The FOQUS documentation was updated to reflect the fact that ALAMO can have two executables and indicates the correct executable to add to the Settings path. SimSinter was updated to version 3.1.0. This version removed gPROMS support and included security updates.

AS↗

Thermal scale modeling

Complex system study data indicate that factors associated with multilayer insulation pose major problem in scale modeling, that numerical analysis aids correction for known compromises of scaling criteria, and that probable errors in scale modeling experiments fall within range predicted by statistical analysis.

Mac Gregor, R. K.↗

Viking Orbiter 1975 articulation control subsystem design analysis

The articulation control subsystem, developed for the Viking Orbiter 1975 spacecraft, is a digital, multiplexed, closed-loop servo system used to control the pointing and positioning of the science scan platform and the high-gain communication antenna, and to position the solar-energy controller louver blades for the thermal control of the propellant tanks. The development, design, and anlaysis of the subsystem is preliminary. The subsystem consists of a block-redundant control electronics multiplexed among eight control actuators. Each electronics block is capable of operating either individually or simultaneously with the second block. This provides the subsystem the capability of simultaneous two-actuator control or a single actuator control with the second block in a stand-by redundant mode. The result of the preliminary design and analysis indicates that the subsystem will perform satisfactorily in the Viking Orbiter 1975 mission. Some of the parameter values used, particularly those in the subsystem dynamics and the error estimates, are preliminary and the results will be updated as more accurate parameter values become available.

Horiuchi, H. H.↗