Search NASA⌕ Search

SEARCH · Search NASA

Results for “error rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Dose Error Impacts on A Collection of Realistic Dose-Response Curves Based on A NASA Sonic Boom Community Noise Survey

The National Aeronautics and Space Administration (NASA) plans to conduct surveys of community response to quiet supersonic flight to collect dose-response data for international regulators. Previous models of noise dose versus annoyance response ignored uncertainty in the noise dose experienced by survey respondents. This dose error causes attenuation bias and results in inaccurate dose-response relationships. The impacts of dose errors can be explored by introducing error into the dose estimates of a simulated community noise survey. The simulated population annoyance response is determined by specific noise response characteristics, including the onset of annoyance intercept, rate of increasing annoyance, participant intercept variability, and response rates. This paper explores the effects of dose errors on notional populations created by perturbing the noise response characteristics observed in participants in a recent NASA flight test, QSF18. The QSF18-based population parameters were shifted up to ±20% to create the study populations. For the anticipated dose range of the X-59, changes to the onset of annoyance intercept have the greatest impact on erroneous model results. Quantifying point estimate errors illustrates the impact of dose error, with errors up to 14 dB observed for a fixed high annoyance percentage.

dose-response modeling↗

An efficient error-propagation-based reduction method for large chemical kinetic mechanisms

Production rates obtained from a detailed chemical mechanism are analyzed in order to quantify the coupling between the various species and reactions involved. These interactions can be represented by a directed relation graph. A geometric error propagation strategy applied to this graph accurately identifies the dependencies of specified targets and creates a set of increasingly simplified kinetic schemes containing only the chemical paths deemed the most important for the targets. An integrity check is performed concurrently with the reduction process to avoid truncated chemical paths and mass accumulation in intermediate species. The quality of a given skeletal model is assessed through the magnitude of the errors introduced in the target predictions. The applied error evaluation is variable-dependent and unambiguous for unsteady problems. The technique yields overall monotonically increasing errors, and the smallest skeletal mechanism that satisfies a user-defined error tolerance over a selected domain of applicability is readily obtained. An additional module based on life-time analysis identifies a set of species that can be modeled accurately by quasi-steady state relations. An application of the reduction procedure is presented for autoignition using a large iso-octane mechanism. The whole process is automatic, is fast, has moderate CPU and memory requirements, and compares favorably to other existing techniques. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rigorous constraints on three-nucleon forces in chiral effective field theory from fast and accurate calculations of few-body observables

We explore the constraints on the three-nucleon force (3NF) of chiral effective field theory (χ EFT) that are provided by bound-state observables in the A = 3 and A = 4 sectors. Our statistically rigorous analysis incorporates experimental error, computational method uncertainty, and the uncertainty due to truncation of the χ EFT expansion at next-to-next-to-leading order. A consistent solution for the 3 H binding energy, the 4 He binding energy and radius, and the 3 H β-decay rate can only be obtained if χ EFT truncation errors are included in the analysis. Here, the β-decay rate is the only one of these that yields a nondegenerate constraint on the 3NF low-energy constants, which makes it crucial for the parameter estimation. We use eigenvector continuation for fast and accurate emulation of no-core shell model calculations of the few-nucleon observables. This facilitates sampling of the posterior probability distribution, allowing us to also determine the distributions of the parameters that quantify the truncation error. We find a χ EFT expansion parameter of Q = 0.33 ± 0.06 for these observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking

Purpose: Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is required to monitor the treatment as it is delivered, allowing comparison with the treatment plan and error detection. In this work, we demonstrate a method for monitoring the treatment as it is delivered and directly comparing the delivered treatment with the treatment plan in the clinical workspace. This treatment verification system is based on a flat panel detector (FPD) used for both pre-treatment imaging and source tracking. Methods: A phantom study was conducted to establish the resolution and precision of the system. A pretreatment radiograph of a phantom containing brachytherapy catheters is acquired and registration between the measurement and treatment planning system (TPS) is performed using implanted fiducial markers. The measured catheter paths immediately prior to treatment were then compared with the plan. During treatment delivery, the position of the {sup 192}Ir source is determined at each dwell position by measuring the exit radiation with the FPD and directly compared to the planned source dwell positions. Results: The registration between the two corresponding sets of fiducial markers in the TPS and radiograph yielded a registration error (residual) of 1.0 mm. The measured catheter paths agreed with the planned catheter paths on average to within 0.5 mm. The source positions measured with the FPD matched the planned source positions for all dwells on average within 0.6 mm (s.d. 0.3, min. 0.1, max. 1.4 mm). Conclusions: We have demonstrated a method for directly comparing the treatment plan with the delivered treatment that can be easily implemented in the clinical workspace. Pretreatment imaging was performed, enabling visualization of the implant before treatment delivery and identification of possible catheter displacement. Treatment delivery verification was performed by measuring the source position as each dwell was delivered. This approach using a FPD for imaging and source tracking provides a noninvasive method of acquiring extensive information for verification in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Biasing errors and corrections

The dependence of laser velocimeter measurement rate on flow velocity is discussed. Investigations outlining that any dependence is purely statistical, and is nonstationary both spatially and temporally, are described. Main conclusions drawn are that the times between successive particle arrivals should be routinely measured and the calculation of the velocity data rate correlation coefficient should be performed to determine if a dependency exists. If none is found, accept the data ensemble as an independent sample of the flow. If a dependency is found, the data should be modified to obtain an independent sample. Universal correcting procedures should never be applied because their underlying assumptions are not valid.

Meyers, James F.↗

Characterization of XR-RV3 GafChromic{sup ®} films in standard laboratory and in clinical conditions and means to evaluate uncertainties and reduce errors

Purpose: To investigate the optimal use of XR-RV3 GafChromic{sup ®} films to assess patient skin dose in interventional radiology while addressing the means to reduce uncertainties in dose assessment. Methods: XR-Type R GafChromic films have been shown to represent the most efficient and suitable solution to determine patient skin dose in interventional procedures. As film dosimetry can be associated with high uncertainty, this paper presents the EURADOS WG 12 initiative to carry out a comprehensive study of film characteristics with a multisite approach. The considered sources of uncertainties include scanner, film, and fitting-related errors. The work focused on studying film behavior with clinical high-dose-rate pulsed beams (previously unavailable in the literature) together with reference standard laboratory beams. Results: First, the performance analysis of six different scanner models has shown that scan uniformity perpendicular to the lamp motion axis and that long term stability are the main sources of scanner-related uncertainties. These could induce errors of up to 7% on the film readings unless regularly checked and corrected. Typically, scan uniformity correction matrices and reading normalization to the scanner-specific and daily background reading should be done. In addition, the analysis on multiple film batches has shown that XR-RV3 films have generally good uniformity within one batch (<1.5%), require 24 h to stabilize after the irradiation and their response is roughly independent of dose rate (<5%). However, XR-RV3 films showed large variations (up to 15%) with radiation quality both in standard laboratory and in clinical conditions. As such, and prior to conducting patient skin dose measurements, it is mandatory to choose the appropriate calibration beam quality depending on the characteristics of the x-ray systems that will be used clinically. In addition, yellow side film irradiations should be preferentially used since they showed a lower dependence on beam parameters compared to white side film irradiations. Finally, among the six different fit equations tested in this work, typically used third order polynomials and more rational and simplistic equations, of the form dose inversely proportional to pixel value, were both found to provide satisfactory results. Fitting-related uncertainty was clearly identified as a major contributor to the overall film dosimetry uncertainty with up to 40% error on the dose estimate. Conclusions: The overall uncertainty associated with the use of XR-RV3 films to determine skin dose in the interventional environment can realistically be estimated to be around 20% (k = 1). This uncertainty can be reduced to within 5% if carefully monitoring scanner, film, and fitting-related errors or it can easily increase to over 40% if minimal care is not taken. This work demonstrates the importance of appropriate calibration, reading, fitting, and other film-related and scan-related processes, which will help improve the accuracy of skin dose measurements in interventional procedures.

60 APPLIED LIFE SCIENCES↗

Image data compression having minimum perceptual error

A method for performing image compression that eliminates redundant and invisible image components is described. The image compression uses a Discrete Cosine Transform (DCT) and each DCT coefficient yielded by the transform is quantized by an entry in a quantization matrix which determines the perceived image quality and the bit rate of the image being compressed. The present invention adapts or customizes the quantization matrix to the image being compressed. The quantization matrix comprises visual masking by luminance and contrast techniques and by an error pooling technique all resulting in a minimum perceptual error for any given bit rate, or minimum bit rate for a given perceptual error.

Watson, Andrew B.↗

Increased But Error-Prone Nonhomologous End Joining in Immortalized Lymphoblastoid Cell Extracts From Adult Cancer Patients With Late Radionecrosis

Purpose: To study nonhomologous end joining in extracts of two lymphoblastoid cell lines derived from patients with late radionecrosis after radiotherapy. Both cell lines were previously shown to exhibit impaired rejoining of DNA double-strand breaks in a pulse-field gel electrophoresis assay. Methods and Materials: We used a cell-free system and quantitative real-time polymerase chain reaction, as well as sequencing analysis of end joining products. Results: Paradoxically, extracts of the two cell lines display increased rates of in vitro end joining of noncohesive termini compared with normal cell extracts. This increase was seen in the absence of added deoxyribonucleoside triphosphates and was sensitive to inhibition by wortmannin. Sequencing of the joined products revealed that, despite increased rates of end joining, the process was error prone with a greater frequency of deletions compared with that observed in normal controls. Conclusion: These findings are consistent with the suggestion that a promiscuous, deletion-prone abnormality of nonhomologous end joining might underpin the predisposition of certain radiotherapy patients to late radionecrosis. We hypothesize that some individuals might harbor subclinical defects in nonhomologous end joining that clinically manifest on challenge with high-dose radiation. Because both quantitative and qualitative aspects of end joining have demonstrably been influenced, we recommend that the study of patient samples should involve a combination of quantitative methods (e.g., quantitative real-time polymerase chain reaction), sequencing analysis, and a comparison of multiple join types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Classifiers for U-235 Source Signatures Using Gamma Spectral Measurements

Signatures associated with low-level U-235 sources are studied from a classification analytics perspective, using NaI gamma-ray spectral measurements from detectors located at various distances from the source. Data sets collected at a shielded facility are utilized, wherein the source is introduced via a conduit into a formation of 21 NaI detectors deployed over 6 x 6 meters area in a formation of two concentric circles and one spiral. The activity levels in the spectral regions associated with potential U-235 signatures are estimated as counts at 1 second intervals, and are used as features to train classifiers for detecting the presence of the source. Eight different classifiers are trained and tested using the background and source measurements collected over multiple experimental runs. As expected, the classifier performance improved overall as measurements from the detectors closer to source are used, but also revealed unexpectedly low performance by two detectors that are identically produced and configured as others. Six of eight classifiers have an overall comparable performance, for example, three of them achieved zero training error and 99% detection at 4% false alarm rate for a detector located 1.3 meters away from the source. Also, larger training sets led to improved classification performance across all classifiers, and interestingly, the classifiers with the minimum training error did not necessarily achieve the highest classification performance on test data.

Rao, Nageswara↗

Variance-Reduced Accelerated First-Order Methods: Central Limit Theorems and Confidence Statements

In this paper, we consider a strongly convex stochastic optimization problem and propose three classes of variable sample-size stochastic first-order methods: (i) the standard stochastic gradient descent method, (ii) its accelerated variant, and (iii) the stochastic heavy-ball method. In each scheme, the exact gradients are approximated by averaging across an increasing batch size of sampled gradients. We prove that when the sample size increases at a geometric rate, the generated estimates converge in mean to the optimal solution at an analogous geometric rate for schemes (i)–(iii). Based on this result, we provide central limit statements, whereby it is shown that the rescaled estimation errors converge in distribution to a normal distribution with the associated covariance matrix dependent on the Hessian matrix, the covariance of the gradient noise, and the step length. If the sample size increases at a polynomial rate, we show that the estimation errors decay at a corresponding polynomial rate and establish the associated central limit theorems (CLTs). Under certain conditions, we discuss how both the algorithms and the associated limit theorems may be extended to constrained and nonsmooth regimes. As a result, we provide an avenue to construct confidence regions for the optimal solution based on the established CLTs and test the theoretical findings on a stochastic parameter estimation problem.

Lei, Jinlong↗

External Interference Effects of Flow Through Static-Pressure Orifices of an Airspeed Head at Several Supersonic Mach Numbers and Angles of Attack

Wind-tunnel tests have been made to determine the static-pressure error resulting from external interference effects of flow through the static-pressure orifices of an NACA airspeed head at Mach numbers of 2.4, 3.0, and 4.0 for angles of attack of 0 deg, 5 deg, 10 deg, and 15 deg. Within the accuracy of the measurements and for the range of mass flow covered, the static-pressure error increased linearly with increasing mass-flow rate for both the forward and rear sets of orifices at all Mach numbers and angles of attack of the investigation. For a given value of flow coefficient, the static-pressure error varied appreciably with Mach number but only slightly with angle of attack. For example, for a flow coefficient out of the orifices of 0.01 (the approximate value for a vertically climbing airplane for which the airspeed system incorporates an airspeed meter, a Mach meter, and an altimeter), the error increased from about 5 percent to about 12 percent of the static pressure as the Mach number increased from 2.4 to 4.0 with the airspeed head at an angle of attack of 0 deg.

Silsby, Norman S.↗

Kinetic Modeling of a Silicon Refining Process in a Moist Hydrogen Atmosphere

We developed a kinetic model that considers both silicon loss and boron removal in a metallurgical grade silicon refining process. This model was based on the hypotheses of reversible reactions. The reaction rate coefficient kept the same form but error of terminal boron concentration could be introduced when relating irreversible reactions. Experimental data from published studies were used to develop a model that fit the existing data. At 1500 °C, our kinetic analysis suggested that refining silicon in a moist hydrogen atmosphere generates several primary volatile species, including SiO, SiH, HBO, and HBO{sub 2}. Using the experimental data and the kinetic analysis of volatile species, we developed a model that predicts a linear relationship between the reaction rate coefficient k and both the quadratic function of p(H{sub 2}O) and the square root of p(H{sub 2}). Moreover, the model predicted the partial pressure values for the predominant volatile species and the prediction was confirmed by the thermodynamic calculations, indicating the reliability of the model. We believe this model provides a foundation for designing a silicon refining process with a fast boron removal rate and low silicon loss.

36 MATERIALS SCIENCE↗

A comparison of microwave techniques for measuring rainfall

The purpose of this paper is to evaluate within a common framework a large number of techniques for nearly instantaneous microwave measurements of rainfall and to determine the range of rainfall rates best suited to the various techniques and estimators. The physical basis of a technique as transformed by measurement imperfections of real instruments determines the ultimate performance capability of any microwave rain estimator. While many of the defects of the measurement process apply to all techniques, the physics behind each estimator differs. A method is presented for objectively evaluating the physical bases of the techniques and for quantifying estimator performance for perfect instruments. These results are then tempered by standard measurement errors to yield more realistic results. Analysis demonstrates that, in general, the minimization of rainfall estimate errors over a wide range of rainfall rates requires the simultaneous application of more than one microwave rainfall measurement technique.

Jameson, A. R.↗

A Multi-Region SEIR Model Incorporating Inter-County Mobility and Time-Dependent Transmission Dynamics: Application to COVID-19 Disease Outbreak Data in North Carolina.

Classical infectious disease compartmental models typically do not incorporate spatial heterogeneity or mobility. We develop a multi-region susceptible-exposed-infected-recovered (SEIR) model in which disease dynamics are coupled via inter-region mobility and the transmission rate is both region and time dependent. We calibrate the model using rolling averages of daily COVID-19 data in all 100 North Carolina counties. Mobility parameters are prescribed using daily inter-county commuter data. The number of transmission rate parameters is substantially reduced by hypothesizing that the dynamics correlate with county-level population density. Parameter estimation is carried out using several objective functions with error terms at different scales. An additive combination of least squares error at the county-level and the state-level, along with a quadratic transmission rate polynomial, yields the lowest overall error at both spatial scales. The calibrated model is used to simulate regional effects of perturbing disease transmission rates in adjacent counties and to illustrate effects of the state’s mobility infrastructure on disease dynamics and spread for a new disease outbreak.

COVID-19 modeling↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗

Provably accurate simulation of gauge theories and bosonic systems

Quantum many-body systems involving bosonic modes or gauge fields have infinite-dimensional local Hilbert spaces which must be truncated to perform simulations of real-time dynamics on classical or quantum computers. To analyze the truncation error, we develop methods for bounding the rate of growth of local quantum numbers such as the occupation number of a mode at a lattice site, or the electric field at a lattice link. Our approach applies to various models of bosons interacting with spins or fermions, and also to both abelian and non-abelian gauge theories. We show that if states in these models are truncated by imposing an upper limit &#x039B; on each local quantum number, and if the initial state has low local quantum numbers, then an error at most &#x03F5; can be achieved by choosing &#x039B; to scale polylogarithmically with &#x03F5; &#x2212; 1 , an exponential improvement over previous bounds based on energy conservation. For the Hubbard-Holstein model, we numerically compute a bound on &#x039B; that achieves accuracy &#x03F5; , obtaining significantly improved estimates in various parameter regimes. We also establish a criterion for truncating the Hamiltonian with a provable guarantee on the accuracy of time evolution. Building on that result, we formulate quantum algorithms for dynamical simulation of lattice gauge theories and of models with bosonic modes; the gate complexity depends almost linearly on spacetime volume in the former case, and almost quadratically on time in the latter case. We establish a lower bound showing that there are systems involving bosons for which this quadratic scaling with time cannot be improved. By applying our result on the truncation error in time evolution, we also prove that spectrally isolated energy eigenstates can be approximated with accuracy &#x03F5; by truncating local quantum numbers at &#x039B; = polylog ( &#x03F5; &#x2212; 1 ) .

Tong, Yu↗

A Modified Johnson–Cook Constitutive Model for the Compressive Flow Behaviors of the SnSbCu Alloy at High Strain Rates

The SnSbCu alloy is widely used as the material for the main bearing in low-speed marine engines, and an accurate constitutive model is the foundation for studying the frictional behaviors of bearings. In this work, the compressive flow behaviors of the SnSbCu alloy were considered under the different strain rates (1000-5000 s{sup −1}) and temperatures (20-110 °C) by quasi-static and split-Hopkinson pressure bar dynamic compression tests. First, the original Johnson–Cook model was used to describe the constitutive relation of the SnSbCu alloy at high strain rates, and the results predicted by the original model showed relatively large errors compared with the experimental results since the coupled effect of temperature and strain rate was omitted. Then, a modified Johnson–Cook constitutive model was developed to describe the compressive flow behaviors of the SnSbCu alloy, and the results predicted by this modified model agreed well with the experimental data. Moreover, a finite element analysis was also conducted to verify the accuracy of the modified Johnson–Cook model.

36 MATERIALS SCIENCE↗

Simulating and Detecting Radiation-Induced Errors for Onboard Machine Learning

Spacecraft processors and memory are subjected to high radiation doses and therefore employ radiation-hardened components. However, these components are orders of magnitude more expensive than typical desktop components, and they lag years behind in terms of speed and size. We have integrated algorithm-based fault tolerance (ABFT) methods into onboard data analysis algorithms to detect radiation-induced errors, which ultimately may permit the use of spacecraft memory that need not be fully hardened, reducing cost and increasing capability at the same time. We have also developed a lightweight software radiation simulator, BITFLIPS, that permits evaluation of error detection strategies in a controlled fashion, including the specification of the radiation rate and selective exposure of individual data structures. Using BITFLIPS, we evaluated our error detection methods when using a support vector machine to analyze data collected by the Mars Odyssey spacecraft. We found ABFT error detection for matrix multiplication is very successful, while error detection for Gaussian kernel computation still has room for improvement.

data analysis↗