Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Genistein modulates the expression of NF-κB and MAPK (p-38 and ERK1/2), thereby attenuating D-Galactosamine induced fulminant hepatic failure in Wistar rats

Genistein is an isoflavanoid abundantly found in soy. It has been found to play an important role in the prevention of various chronic diseases including cancer. In this study, we evaluated potential therapeutic properties of Genistein against D-Galactosamine (D-GalN) induced inflammation and hepatotoxicity in male Wistar rats. Fulminant hepatic failure (FHF) was induced in rats by intraperitoneal injection of D-GalN (700 mg/kgBW). Genistein (5 mg/kgBW/day) was given as pre-treatment for 30 days via intra-gastric route followed by D-GalN (700 mg/kgBW) injection. The hepatoprotective and curative effects of Genistein were evident from a significant decrease in the serum aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels as well as prevention of histological damage by pre-treatment of Genistein. Genistein pre-treatment significantly inhibited the increased protein levels of inducible nitric oxide synthase (iNOS) and cyclooxygenase-2 (COX-2), thereby reducing nitric oxide (NO) and prostaglandin-E2 (PGE) levels, respectively. In addition Genistein significantly suppressed the production of D-GalN-induced proinflammatory cytokines, including tumor necrosis factor-α (TNF-α) and interleukin (IL)-1β. These inhibitory effects were associated with the suppression of nuclear factor-kappa B (NF-ĸB) activation, IKKα/β and Mitogen activated protein kinase (MAPK) phosphorylation by Genistein in D-GalN-treated animals. In conclusion, our results suggest that Genistein may serve as a potential supplement in the prevention of hepatic and inflammatory diseases. Furthermore Genistein is able to maintain the redox potential and strengthens the antioxidant defense system of a cell. - Highlights: • First study to evaluate hepatoprotective effect of Genistein against D-GalN • Genistein prevents oxidative damage induced by D-GalN. • Genistein blunts iNOS, COX-2, NF-ĸB, IKKα/β and MAPK expression. • Genistein prevents D-GalN induced apoptosis and necrosis.

60 APPLIED LIFE SCIENCES↗

TiN coated aluminum electrodes for DC high voltage electron guns

Preparing electrodes made of metals like stainless steel, for use inside DC high voltage electron guns, is a labor-intensive and time-consuming process. In this paper, the authors report the exceptional high voltage performance of aluminum electrodes coated with hard titanium nitride (TiN). The aluminum electrodes were comparatively easy to manufacture and required only hours of mechanical polishing using silicon carbide paper, prior to coating with TiN by a commercial vendor. The high voltage performance of three TiN-coated aluminum electrodes, before and after gas conditioning with helium, was compared to that of bare aluminum electrodes, and electrodes manufactured from titanium alloy (Ti-6Al-4V). Following gas conditioning, each TiN-coated aluminum electrode reached −225 kV bias voltage while generating less than 100 pA of field emission (<10 pA) using a 40 mm cathode/anode gap, corresponding to field strength of 13.7 MV/m. Smaller gaps were studied to evaluate electrode performance at higher field strength with the best performing TiN-coated aluminum electrode reaching ∼22.5 MV/m with field emission less than 100 pA. These results were comparable to those obtained from our best-performing electrodes manufactured from stainless steel, titanium alloy and niobium, as reported in references cited below. The TiN coating provided a very smooth surface and with mechanical properties of the coating (hardness and modulus) superior to those of stainless steel, titanium-alloy, and niobium electrodes. These features likely contributed to the improved high voltage performance of the TiN-coated aluminum electrodes.

36 MATERIALS SCIENCE↗

Clinical evaluation of a medical high dynamic range display

Purpose: Recent new medical displays do have higher contrast and higher luminance but do not have a High Dynamic Range (HDR). HDR implies a minimum luminance value close to zero. A medical HDR display prototype based on two Liquid Crystal layers has been developed. The goal of this study is to evaluate the potential clinical benefit of such display in comparison with a low dynamic range (LDR) display. Methods: The study evaluated the clinical performance of the displays in a search and detection task. Eight radiologists read chest x-ray images some of which contained simulated lung nodules. The study used a JAFROC (Jacknife Free Receiver Operating Characteristic) approach for analyzing FROC data. The calculated figure of merit (FoM) is the probability that a lesion is rated higher than all rated nonlesions on all images. Time per case and accuracy for locating the center of the nodules were also compared. The nodules were simulated using Samei’s model. 214 CR and DR images [half were “healthy images” (chest nodule-free) and half “diseased images”] were used resulting in a total number of nodules equal to 199 with 25 images with 1 nodule, 51 images with 2 nodules, and 24 images with 3 nodules. A dedicated software interface was designed for visualizing the images for each session. For the JAFROC1 statistical analysis, the study is done per nodule category: all nodules, difficult nodules, and very difficult nodules. Results: For all nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.09% of difference. For the difficult nodules, the averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 1.38% of difference. The averaged FoM{sub HDR} is slightly higher than FoM{sub LDR} with 0.71% of difference. For the true positive fraction (TPF), both displays (the HDR and the LDR ones) have similar TPF for all nodules, but looking at difficult and very difficult nodules, there are more TP for the HDR display. The true positive fraction has been also computed in function of the local average luminance around the nodules. For the lowest luminance range, there is more than 30% in favor of the HDR display. For the highest luminance range, there is less than 6% in favor of the LDR display. Conclusions: This study shows the potential benefit of using a HDR display in radiology.

60 APPLIED LIFE SCIENCES↗

Information or resolution: Which is required from an SEM to study bulk inorganic materials?: Evaluate SEMs’ practical performance

Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. The electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energydispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. Finally, for an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly affect the usability of the SEM.

36 MATERIALS SCIENCE↗

Transcatheter Arterial Embolization of Spontaneous Soft Tissue Hematomas: A Systematic Review

Background: Severe spontaneous soft tissue hematomas (SSTH) are usually treated with transcatheter arterial embolization (TAE) although only limited retrospective studies exist evaluating this treatment option. The aim of this study was to systematically assess the efficacy and safety of TAE for the management of SSTH. Methods: Medline, EMBASE, PubMed and Cochrane Library were searched from inception to July 2017 using MeSH headings and a combination of keywords. Eligibility was restricted to original studies with patients suffering from SSTH treated with TAE. Patients with traumatic hematomas or who were treated with solely conservative or surgical management were excluded. For each publication, clinical success based on the control of the bleed, rebleeding rates and complications (including mortality) was collected, as well as technical details. Results: Sixty-three studies met the inclusion criteria, with an aggregate total of 267 patients. Follow-up extended from 1 day to 10 years. Bleeding was mainly localized to the iliopsoas (n = 113/267, 42.3%) and anterior abdominal wall (n = 145/266, 54.7%). When information was available, 81.0% (n = 158/195) of patients were on anticoagulant therapy prior to the bleeding episode. Initial stabilization with control of the bleed was obtained in 93.1% (n = 242 patients, n = 60 studies). The most common embolic materials were coils (n = 129, 54.4%). Rebleeding was reported in 25 patients (9.4%). Only two embolization complications were reported (0.7%). The 30-day mortality was 22.7% (n = 42/1857). Conclusion: TAE represents a safe and effective procedure in the management of SSTH. We present a management algorithm based on these data, but further studies are needed to address the knowledge gap.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemical Degradation of Poly(ethylene terephthalate) for Potential Antimicrobial Activity Evaluation and Molecular Docking Study

Oxadiazole derivatives have been extensively studied for their specific and potent pharmacological property. Oxadiazole ring is susceptible to undergo electrophilic and nucleophilic substitution which makes it an interesting candidate to synthesize new derivatives with potential biological activity. Keeping in view their significance, the present work highlights the synthesis of a series of new oxadiazole derivatives from recycled poly(ethylene terephthalate) PET by chemical route. The aminolyzed product of PET i.e. terephthalic dihydrazide is being used for preparation of oxadiazole derivatives. The characterization of the synthesized product was done via FTIR, UV–visible, {sup 1}H-NMR and thermal analysis. The compounds showed potential antimicrobial activity against Candida albicans, Rhizopus, Bacillus cereus and Escherichia coli. Further, molecular docking of the compounds were studied for target proteins Sterol 14α-demethylase, TREX1, and Glucosamine-6-phosphate synthase. The binding energy between the target protein and ligand is calculated and interaction between the two is discussed. The antimicrobial activity carried out for the derivatives were in close correlation with in silico docking study performed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Powder Metallurgy HIP Process Study and Mechanical Property Evaluations for IN740H

The effects of hot isostatic pressing (HIP) parameters and powder size distribution (PSD) on the resulting microstructure and properties of powder metallurgy (P/M) IN740H have been investigated. Properties can be substantially tailored through the appropriate management of these parameters. Applying a thermal presoak to the input powder prior to the sintering stage of HIP can significantly increase average grain size and coarse grain fraction, enabling a trade for improved creep resistance at the expense of tensile strength. Here, powder thermal presoak was found to have a larger impact on microstructure and properties than the use of a coarser PSD alone. Additionally, substantial grain growth and grain boundary migration is observed in P/M IN740H at HIP temperatures above 1260°C. Given its inherently finer grain size, P/M HIP IN740H typically outperforms its cast and wrought counterparts in tensile response. Creep life at 700–800°C was inferior to wrought due to PPBs coincident with grain boundaries which served as cavity nucleation sites, leading to lower creep ductility. The ability to adjust the microstructure toward a more balanced creep and tensile behavior allows P/M HIP IN740H to be considered for high-temperature applications in advanced ultra-supercritical steam and supercritical carbon dioxide power cycles.

36 MATERIALS SCIENCE↗

Influence of fatigue precracking and specimen size on Master Curve fracture toughness measurements of EUROFER97 and F82H steels

EUROFER97 and F82H steels are two leading reduced-activation ferritic-martensitic (RAFM) steels for fusion first wall and blanket applications. Exposure to the harsh environment of fusion reactors can result in severe degradation of fracture toughness. Thus, the post-irradiation evaluation of fracture toughness is critical for understanding the material behavior. Due to the space constraints of irradiation facilities and challenges in controlling a uniform irradiation condition for large size specimens, the development of small specimen test techniques (SSTT) is indispensable to evaluate the performance of irradiated materials. In this study, we evaluated specimen size effects on the Master Curve fracture toughness of EUROFER97 and F82H steels. A wide variety of specimens, including 0.5 T compact tension (C(T)) specimens, 0.16 T mini-compact tension (miniC(T)) specimens, and 1.65 mm miniature bend bar specimens, were tested. The testing methodology was based on the Master Curve method in the ASTM E1921 standard. No specimen size effect was observed in 0.5 T C(T) and 0.16 T miniC(T) specimens on the Master Curve reference temperature T0, while 1.65 mm miniature bend bar specimens yielded a higher T 0Q . A strong effect of fatigue precracking on T 0 for 0.5 T C(T) and 0.16 T miniC(T) specimens was observed, such that testing on specimens with skewed fatigue precrack fronts resulted in lower T 0 than for specimens with ASTM standard qualified straight fatigue precrack fronts. The results highlight the importance of experimental quality control in developing SSTT for Master Curve fracture toughness testing. Lastly, we also evaluated and provided recommendations on the minimum number of specimens needed for each specimen type for yielding reliable T 0Q values.

36 MATERIALS SCIENCE↗

Specimen Size and Geometry Effects on the Master Curve Fracture Toughness Measurements of EUROFER97 and F82H Steels

EUROFER97 and F82H are two leading reduced-activation ferritic-martensitic (RAFM) steels for fusion blanket applications. Exposure to the harsh environment of fusion reactors can result in severe degradation of materials fracture toughness (FT). Thus, the post-irradiation evaluation of FT is critical to understanding the material behavior. Due to the space constraint of irradiation facilities, the development of small specimen test techniques (SSTT) is necessary to evaluate the performance of irradiated materials. In this study, we evaluated the specimen size and geometry effects on the ductile-to-brittle transition FT of EUROFER97 batch-3 and F82H-BA12 steels. The specimen thicknesses ranged from 1.65 to 12.7 mm and the geometries included 1.65 mm bend bar, 4 mm mini-compact tension (miniCT), and 0.5T compact tension (CT) specimens. Fracture toughness testing and evaluations were performed using the Master Curve method in the ASTM E1921-19 standard. After size correction to 1T size using the Master Curve method, no specimen size effect was observed between the 4 mm miniCT and 0.5T CT specimens for the Master Curve reference temperature T0Q, while the bend bars yielded a higher T0Q. A strong effect of fatigue precrack front straightness on T0Q for 0.5T CT specimens was observed. The minimum number of specimens needed for each specimen geometry has been determined.

Chen, Xiang↗

Incidence of Breast Cancer in the Life Span Study of Atomic Bomb Survivors: 1958–2009

The importance of reproductive history in breast tissue development and etiology of sporadic breast cancer in females is well established. However, there is limited evidence of factors, other than age, that modify risk of radiation-related breast cancer. In this study, we evaluated breast cancer incidence in the Life Span Study cohort of atomic bomb survivors, adding 11 years of follow-up and incorporating reproductive history data. We used Poisson regression models to describe radiation risks and modifying effects of age and reproductive factors. Among 62,534 females, we identified 1,470 breast cancers between 1958 and 2009. Of 397 new cases diagnosed since 1998, 75% were exposed before age 20. We found a strong linear dose response with excess relative risk (ERR) of 1.12 per Gy [95% confidence interval (CI): 0.73 to 1.59] for females at age 70 after exposure at age 30. The ERR decreased with increasing attained age (P = 0.007) while excess absolute rate (EAR) increased with attained age up to age 70 (P < 0.001). Age at menarche was a strong modifier of the radiation effect: for a given dose, both the ERR and EAR decreased with increasing age at menarche (P = 0.007 and P < 0.001). Also, independently, age-at-exposure effects on ERR and EAR differed before and after menarche (P = 0.043 and P = 0.015, respectively, relative to log-linear trends), with highest risks for exposures around menarche. Despite the small number of male breast cancers (n = 10), the data continue to suggest a dose response (ERR per Gy = 5.7; 95% CI: 0.3 to 30.8; P = 0.018). Persistently increased risk of female breast cancer after radiation exposure and its modification pattern suggests heightened breast sensitivity during puberty.

60 APPLIED LIFE SCIENCES↗

Case Study: Laboratory and Field Evaluation of Circuit-Level Electrical Submetering with Wireless Current Transformers

Laboratory and field demonstration of circuit-level electrical submetering technology that utilizes wireless current transformers to monitor circuits within the panel. Report provides a background of the technology and how it works, outlines the testing methodology and presents results on measurement accuracy and ability of the technology to be rapidly integrated into both electrical panels/infrastructure and into an analytics platform. Cost effectiveness results are discussed for the specific field demonstration site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Study: Laboratory and Field Evaluation of Circuit-Level Electrical Submetering with Integrated Metering System

Laboratory and field demonstration of circuit-level electrical submetering technology. Report provides a background of the technology and how it works, outlines the testing methodology and presents results on measurement accuracy and ability of the technology to be rapidly integrated into both electrical panels/infrastructure and into an analytics platform. Cost effectiveness results are discussed for the specific field demonstration site.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of shading following installation of agrivoltaic systems on eco-physiological and biochemical attributes of “Howes” cranberry in Massachusetts

Agrivoltaic (AV) systems, which integrate solar energy generation with crop production on the same piece of land, offer a sustainable solution for optimizing land-use efficiency. However, the impact of shading induced by solar panels on crop growth, physiology, and metabolic activities of cranberry is not known. Understanding these interactions is essential for assessing the feasibility of AV systems in cranberry production. In this study we evaluated eco-physiological and biochemical crop responses on a commercial ‘Howes’ cranberry bog grown under an agrivoltaics system using different row spacings in the year immediately following installation. Following installation of fixed tilt solar panels at a height of 3.0 m above the plant canopy, four shading treatments were evaluated: an uncovered control area and row spacings of 9.0 m, 7.0 m, and 5.0 m, corresponding to 30%, 35%, and 37% shading respectively. The shading effect was also evaluated at three different fruit developmental stages (green, blush, and full-red stage). Using microclimate sensors installed in the treatment areas, key eco-physiological and biochemical parameters, including leaf gas exchange, chlorophyll, anthocyanin, and antioxidant content, electrolyte leakage, proline and trehalose accumulation, were assessed. While moderate shading (30% and 35%) alleviated environmental stress, as reflected by improved leaf water status and reduced electrolyte leakage, these same treatments suppressed key physiological and metabolic functions, including photosynthetic activity, carbon reserve accumulation, and the biosynthesis of stress-related osmolytes and antioxidant compounds. Under higher shading (37%), these reductions were even more pronounced, indicating a potential threshold beyond which the benefits of shading are outweighed by declines in assimilate production and secondary metabolism. These findings highlight a trade-off between the stress-mitigating benefits of shading and the alterations in key physiological and metabolic processes under agrivoltaic systems. Minimizing these trade-offs by optimizing row spacing in agrivoltaics systems is critical to maintain cranberry physiological status. Since commercial cranberry is grown as a continuous plant canopy (no interrow spaces for equipment travel), damage caused by the installation process likely impacted crop response evaluated in the first year; multi-year studies are needed to fully understand the dynamics of a dual-use system. Notably, this work provides the first direct measurements of proline, trehalose content, and electrolyte leakage in cranberry grown under AV conditions, offering new insight into their physiological adjustments to shading.

14 SOLAR ENERGY↗