Search NASA⌕ Search

SEARCH · Search NASA

Results for “intermediates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Electrical, thermal, and H 2 O and CO 2 poisoning behaviors of PrNi 0.5 Co 0.5 O 3-δ electrode for intermediate temperature protonic ceramic electrochemical cells

PrNi 0.5 Co 0.5 O 3-δ (PNC) exhibits adequate total electrical conductivity (~300 S/cm at 400–600 °C) and moisture has no significant effect on it. The thermal expansion coefficient of PNC is 17.6 × 10 –6 /K by dilatometry and 18.43 × 10 –6 /K by in situ XRD. PNC also demonstrates chemical stability against H 2 O and CO 2 . However, PNC symmetrical cell over proton-conducting BaZr 0.4 Ce 0.4 Y 0.1 Yb 0.1 O 3-δ (BZCYYb4411) electrolyte shows significant H 2 O and CO 2 poisoning when those are introduced into O 2 –N 2 mixture. In comparison, symmetrical cells with PNC electrode over the oxygen ion conducting Ce 0.9 Gd 0.1 O 2-δ (GDC) electrolyte show no H 2 O and CO 2 poisoning under similar conditions. Here, it is hypothesized that poisoning from H 2 O and CO 2 of the PNC proton conducting symmetrical cell is caused by their adsorption on the BZCYYb4411 electrolyte instead of PNC electrode. Such a hypothesis is supported by the H 2 O and CO 2 adsorption behaviors on PNC and BZCYYb4411 powder surfaces, as measured by temperature programmed desorption (TPD).

08 HYDROGEN↗

Metal DiCarbides as Intermediate Species in thermal Ion Formation Mechanisms

The lanthanide elements (lanthanum to lutetium) adsorbed onto resin beads have been studied as thermal ionization sources. Temperatures at which these ion sources gave maximum intensities were measured for each of these elements. The temperature trends track the trends in the dissociation energies of the corresponding metal dicarbide compounds. The metal dicarbide functions as a carrier to take the lanthanide element to higher temperatures than otherwise attainable. This results in the release of the atomic species at a higher temperature where the ionization probability is significantly increased. This breaking of molecular bonds releasing the atoms at these elevated temperatures is hypothesized as the reason for high ionization efficiencies.

58 GEOSCIENCES↗

Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Men With Intermediate-Risk Prostate Cancer: Analysis of Short- and Medium-Term Toxicity and Quality of Life

Purpose: To determine the short- and medium-term effects of a single high-dose-rate brachytherapy fraction of 15Gy and hypofractionated external beam radiation therapy for prostate cancer. Methods and Materials: Eligible patients had localized prostate cancer with a Gleason score of 7 and a prostate-specific antigen (PSA) concentration of <20 ng/ml or a Gleason score of 6 with a PSA concentration of 10 to 20 ng/ml. Patients received high-dose-rate brachytherapy as a single 15-Gy dose, followed by external beam radiation therapy at 37.5Gy in 15 fractions, and were followed prospectively for toxicity (using Common Terminology Criteria for Adverse Events version 3.0), urinary symptoms (using the International Prostate Symptom Score [IPSS]), erectile function (with the International Index of Erectile Function [IIEF]), and health-related quality of life (with the Expanded Prostate Cancer Index Composite [EPIC]). Clinical examinations and PSA measurements were performed at every visit, and prostate biopsies were repeated at 2 years. The trial accrued 125 patients, with a median follow-up of 1.14 years. Results: Acute grade 2 and 3 genitourinary toxicity occurred in 62% and 1.6% of patients, respectively, and acute grade 2 gastrointestinal toxicity occurred in 6.5% of patients. No grade 3 late toxicity has occurred: 47% of patients had grade 2 genitourinary and 10% of patients had grade 2 gastrointestinal toxicity. Median IPSSs rose from 5 at baseline to 12 at 1 month and returned to 7 at 3 months. Of the total number of patients who were initially potent (IIEF, >21), 8% of patients developed mild to moderate dysfunction, and 27% of patients developed severe erectile dysfunction. Baseline EPIC bowel, urinary, and sexual bother scores decreased by 9, 7, and 19 points, respectively, at 1 year. No patient has experienced biochemical failure, and 16 of the first 17 biopsy results showed no malignancy. Conclusions: Treatment is well tolerated in the short and medium term, with low toxicity and encouraging early indicators of disease control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Nodal Radiotherapy in Patients With Unfavorable Intermediate and High-Risk Prostate Cancer: Evidence, Rationale, and Future Directions

Over the past 15 years, there have been three major advances in the use of external beam radiotherapy in the management of men with clinically localized prostate made. They include: (1) image guided (IG) three-dimensional conformal/intensity modulated radiotherapy; (2) radiation dose escalation; and (3) androgen deprivation therapy. To date only the last of these three advances have been shown to improve overall survival. The presence of occult pelvic nodal involvement could explain the failure of increased conformality and dose escalation to prolong survival, because the men who appear to be at the greatest risk of death from clinically localized prostate cancer are those who are likely to have lymph node metastases. This review discusses the evidence for prophylactic pelvic nodal radiotherapy, including the key trials and controversies surrounding this issue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of an RTOG Phase II Trial (00-19) of External-Beam Radiation Therapy Combined With Permanent Source Brachytherapy for Intermediate-Risk Clinically Localized Adenocarcinoma of the Prostate

Purpose: External-beam radiation therapy combined with low-doserate permanent brachytherapy are commonly used to treat men with localized prostate cancer. This Phase II trial was performed to document late gastrointestinal or genitourinary toxicity as well as biochemical control for this treatment in a multi-institutional cooperative group setting. This report defines the long-term results of this trial. Methods and Materials: All eligible patients received external-beam radiation (45 Gy in 25 fractions) followed 2-6 weeks later by a permanent iodine 125 implant of 108 Gy. Late toxicity was defined by the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring scheme. Biochemical control was defined by the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus definition and the ASTRO Phoenix definition. Results: One hundred thirty-eight patients were enrolled from 20 institutions, and 131 were eligible. Median follow-up (living patients) was 8.2 years (range, 2.7-9.3 years). The 8-year estimate of late grade >3 genitourinary and/or gastrointestinal toxicity was 15%. The most common grade >3 toxicities were urinary frequency, dysuria, and proctitis. There were two grade 4 toxicities, both bladder necrosis, and no grade 5 toxicities. In addition, 42% of patients complained of grade 3 impotence (no erections) at 8 years. The 8-year estimate of biochemical failure was 18% and 21% by the Phoenix and ASTRO consensus definitions, respectively. Conclusion: Biochemical control for this treatment seems durable with 8 years of follow-up and is similar to high-dose external beam radiation alone or brachytherapy alone. Late toxicity in this multi-institutional trial is higher than reports from similar cohorts of patients treated with high-dose external-beam radiation alone or permanent low-doserate brachytherapy alone, perhaps suggesting further attention to strategies that limit doses to normal structures or to unimodal radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Recurrence After Low-Dose-Rate Prostate Brachytherapy: A Population-Based Study of 2223 Consecutive Low- and Intermediate-Risk Patients

Objectives: This study examined patterns of recurrence after low–dose-rate prostate brachytherapy (LDR-PB), estimated local recurrence rate and compared that rate to the estimated local recurrence rate after radical prostatectomy (RP). Methods and Materials: A prospective database was maintained with clinical, dosimetric, and outcome data for all LDR-PB implantation procedures performed at our institution. From 1998 to 2008, 2223 patients with prostate cancer received LDR-PB without supplemental external beam radiation therapy. Patients who developed Phoenix-defined biochemical failure were reviewed for sites of relapse and investigations completed. Results: At a median follow-up of 5 years, 108 of 2223 patients (4.8%) developed biochemical relapse. In 1 additional patient, local relapse was found on transurethral prostate resection, but his prostate-specific antigen concentration was well short of triggering Phoenix-defined failure. Of the 109 patients with disease relapse, 18 of 2223 (0.8%) had a proven local recurrence, and 30 of 2223 (1.3%) had a proven distant recurrence. The remaining 61 of 2223 patients (2.7%) had unidentified sites of recurrence; of these, 57 patients (93%) had digital rectal examinations (DREs), 18 (30%) had post-treatment biopsies, 45 (74%) had bone scans, and 34 (56%) had computed tomography imaging of the abdomen and pelvis. If every biochemical failure were local, the local recurrence rate would be as high as 4.9%; however, by excluding those with proven distant failure and those with both a negative DRE and biopsy, we estimate that the local recurrence rate is 2.7% or less. Conclusions: In the context of limitations of the study design, our population-based analysis indicates that the local recurrence rate after LDR-PB is as low or lower than that after RP in our jurisdiction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis

Purpose: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. Methods and Materials: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SV determined the “ground truth” for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. Results: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. Conclusions: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold. Traditional margin based on the COM or border underestimates the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗