Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

On deformation twinning in a 17.5%Mn-TWIP steel: A physically-based phenomenological model

TWinning Induced Plasticity (TWIP) steel is a typical representative of the 2nd generation of advanced high strength steel (AHSS) which exhibits a combination of high strength and excellent ductility due to the twinning mechanisms. This paper discusses the principal features of deformation twinning in faced-centered cubic austenitic steels and shows how a physiscally-based macroscopic model can be derived from microscopic considerations. In fact, a dislocation-based phenomenological model, with internal state variables such as dislocation density and micro-twins volume fraction representing the microstructure evolution during deformation process, is proposed to describe the deformation behavior of TWIP steels. The contribution of this work is the incorporation of a physically-based twin’s nucleation and volume fraction evolution model in a conventional dislocation-based approach. Microstructural level investigations, using scanning electron microscope (SEM) and transmission electron microscope (TEM) techniques, for the TWIP steel Fe–17.5 wt.% Mn–1.4 wt.% Al- 0.56 wt.% C, are used to validate and verify modeling assumptions. The model could be regarded as a semi-phenomenological approach with sufficient links between microstructure and overall properties and therefore offers good predictive capabilities. Its simplicity also allows a modular implementation in finite element-based metal forming simulations.

36 MATERIALS SCIENCE↗

Microfluidic system for transmission electron microscopy

We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

99 GENERAL AND MISCELLANEOUS↗

Intra-unit-cell electronic nematicity of the high-Tc copper-oxide pseudogap states

In the high-transition-temperature (high-T c ) superconductors the pseudogap phase becomes predominant when the density of doped holes is reduced. Within this phase it has been unclear which electronic symmetries (if any) are broken, what the identity of any associated order parameter might be, and which microscopic electronic degrees of freedom are active. Here we report the determination of a quantitative order parameter representing intra-unit-cell nematicity: the breaking of rotational symmetry by the electronic structure within each CuO 2 unit cell. We analyse spectroscopic-imaging scanning tunnelling microscope images of the intra-unit-cell states in underdoped Bi 2 Sr 2 CaCu 2 }O 8+δ and, using two independent evaluation techniques, find evidence for electronic nematicity of the states close to the pseudogap energy. Moreover, we demonstrate directly that these phenomena arise from electronic differences at the two oxygen sites within each unit cell. If the characteristics of the pseudogap seen here and by other techniques all have the same microscopic origin, this phase involves weak magnetic states at the O sites that break 90°-rotational symmetry within every CuO 2 unit cell.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compact high-resolution differential interference contrast soft x-ray microscopy

We demonstrate high-resolution x-ray differential interference contrast (DIC) in a compact soft x-ray microscope. Phase contrast imaging is enabled by the use of a diffractive optical element objective which is matched to the coherence conditions in the microscope setup. The performance of the diffractive optical element objective is evaluated in comparison with a normal zone plate by imaging of a nickel siemens star pattern and linear grating test objects. Images obtained with the DIC optic exhibit typical DIC enhancement in addition to the normal absorption contrast. Contrast transfer functions based on modulation measurements in the obtained images show that the DIC optic gives a significant increase in contrast without reducing the spatial resolution. The phase contrast operation mode now available for our compact soft x-ray microscope will be a useful tool for future studies of samples with low absorption contrast.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surface potential and magnetic properties of La{sub 0.7}Sr{sub 0.3}MnO{sub 3} periodic arrays fabricated by direct electron beam writing

It is demonstrated that magnetic periodic arrays can be easily fabricated from direct writing water developable La{sub 0.7}Sr{sub 0.3}MnO{sub 3} electron beam resist. Two unique features of our approach are (1) the patterned La{sub 0.7}Sr{sub 0.3}MnO{sub 3} resist film can be developed using nontoxic and environmentally friendly pure water and (2) either positive or negative patterns can be fabricated depending on the dosage of electron beam. The mechanism of the dual function characteristic of the resist was studied using Kelvin probe microscope. The surface potential of patterned La{sub 0.7}Sr{sub 0.3}MnO{sub 3} resist increases with increasing electron beam dosage due to the changes of resist composition. The formations of periodic magnetic arrays were confirmed by the studies of scanning electron microscope and magnetic force microscope. The magnetization of La{sub 0.7}Sr{sub 0.3}MnO{sub 3} can be enhanced by postsintering the sample at 900 deg. C after electron beam irradiation. We have therefore provided a one-step, simple, and convenient alternative technique for the fabrication of nanoscale magnetic patterns, which form the building blocks for the study of physical properties in periodic magnetic arrays.

36 MATERIALS SCIENCE↗

An in situ cell to study phase transitions in individual aerosol particles on a substrate using scanning transmission x-ray microspectroscopy

A new in situ cell to study phase transitions and chemical processes on individual aerosol particles in the x-ray transmission microscope at the PolLux beamline of the Swiss light source has been built. The cell is machined from stainless steel and aluminum components and is designed to be used in the standard mount of the microscope without need of complicated rearrangements of the microscope. The cell consists of two parts, a back part which contains connections for the gas supply, heating, cooling devices, and temperature measurement. The second part is a removable clip, which hosts the sample. This clip can be easily exchanged and brought into a sampling unit for aerosol particles. Currently, the cell can be operated at temperatures ranging from -40 to +50 deg. C. The function of the cell is demonstrated using two systems of submicron size: inorganic sodium bromide aerosols and soot originating from a diesel passenger car. For the sodium bromide we demonstrate how phase transitions can be studied in these systems and that O1s spectra from aqueous sodium bromide solution can be taken from submicron sized particles. For the case of soot, we demonstrate that the uptake of water onto individual soot particles can be studied.

36 MATERIALS SCIENCE↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-Ray Microscopy at HZB: Zone Plate Development and Imaging Using the Third Order of Diffraction

The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/{Delta}E = 10{sup 4}. An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to employ higher orders of diffraction of the zone plate objective. In this paper, we demonstrate that 11-nm lines and spaces of a multilayer test structure are clearly resolved by the x-ray microscope using the third order of diffraction of a zone plate objective with 20-nm outermost zone width. The disadvantage of high-order imaging is an about one order of magnitude lower diffraction efficiency of the used zone plates employed in the third order compared to the first order of diffraction. In addition, the measured background signal in the TXM images is no longer negligible. Therefore, we worked on the fabrication of zone plates with sub-20-nm outermost zone width to increase the spatial resolution in the first order of diffraction. A new high-resolution 100-keV e-beam lithography system from VISTEC, which was recently installed at the Helmholtz-Zentrum Berlin, makes these developments possible. Initial results on zone plates with an outermost zone width down to 15 nm exposed with the new e-beam system are presented. Furthermore, the contrast transfer function of the transmission x-ray microscope operating in partial coherence mode is measured by using the first and third diffraction order of the zone plate objective.

43 PARTICLE ACCELERATORS↗

EUV Dark-Field Microscopy for Defect Inspection

An actinic EUV microscope for defect detection on mask blanks for operation in dark field using a table-top discharge-produced plasma source has been developed. Several test structures (pits and bumps) on multilayer mirrors were investigated by our Schwarzschild objective-based EUV microscope at 13.5-nm wavelength and then characterized with an atomic force microscope. Possible defect-detection limits with large field of view and moderate magnification are discussed in terms of required irradiation dose and system performance.

07 ISOTOPE AND RADIATION SOURCES↗

The role of boron segregation in enhanced thermoelectric power factor of CoSi{sub 1-x}B{sub x} alloys

We report on the influence of boron segregation on the thermoelectric properties of CoSi. Contrary to previous suggestions, and in stark contrast to aluminum substitution, boron does not enter the lattice on the Si site, but rather segregates to the grain boundaries in these alloys. Through a combination of x-ray diffraction, scanning electron microscope, and scanning Auger techniques, we present clear evidence of the formation of a CoB phase at the grain boundaries. Consistent with the failure of B to substitute for Si, we observe no changes in the electron concentration or the Seebeck coefficient under boron substitution. The electrical resistivity, on the other hand, displays a non-monotonic behavior with increasing boron concentration, first decreasing for small amounts of boron, before increasing at higher levels of substitution. We attribute this behavior to a combination of an initial healing effect of boron on microcracks, followed by the eventual increase in electron scattering by the secondary CoB phase at higher concentrations.

36 MATERIALS SCIENCE↗

A diamond-based scanning probe spin sensor operating at low temperature in ultra-high vacuum

We present the design and performance of an ultra-high vacuum (UHV) low temperature scanning probe microscope employing the nitrogen-vacancy color center in diamond as an ultrasensitive magnetic field sensor. Using this center as an atomic-size scanning probe has enabled imaging of nanoscale magnetic fields and single spins under ambient conditions. In this article we describe an experimental setup to operate this sensor in a cryogenic UHV environment. This will extend the applicability to a variety of molecular systems due to the enhanced target spin lifetimes at low temperature and the controlled sample preparation under UHV conditions. The instrument combines a tuning-fork based atomic force microscope (AFM) with a high numeric aperture confocal microscope and the facilities for application of radio-frequency (RF) fields for spin manipulation. We verify a sample temperature of <50 K even for strong laser and RF excitation and demonstrate magnetic resonance imaging with a magnetic AFM tip.

36 MATERIALS SCIENCE↗

High temperature oxidation behavior of austenitic stainless steel AISI 304 in steam of nanofluids contain nanoparticle ZrO2

The objective of this study is to evaluate high temperature oxidation behavior of austenitic stainless steel SS 304 in steam of nanofluids contain nanoparticle ZrO{sub 2}. The oxidation was performed at high temperatures ranging from 600 to 800°C. The oxidation time was 60 minutes. After oxidation the surface of the samples was analyzed by different methods including, optical microscope, scanning electron microscope (SEM) and X-ray diffraction (XRD). X-ray diffraction examination show that the oxide scale formed during oxidation of stainless steel AISI 304 alloys is dominated by iron oxide, Fe{sub 2}O{sub 3}. Minor element such as Cr{sub 2}O{sub 3} is also appeared in the diffraction pattern. Characterization by optical microscope showed that cross section microstructure of stainless steel changed after oxidized with the oxide scale on the surface stainless steels. SEM and x-ray diffraction examination show that the oxide of ZrO{sub 2} appeared on the surface of stainless steel. Kinetic rate of oxidation of austenite stainless steel AISI 304 showed that increasing oxidation temperature and time will increase oxidation rate.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electrically tuned photoluminescence in large pitch cholesteric liquid crystal

Cholesteric liquid crystals are known as 1-D photonic band gap materials due to their periodic helical supramolecular structure and larger birefringence. Depending upon the helical twisted pitch length, they give the characteristic contrast due to selective Bragg reflections when viewed through the polarizing optical microscope and hence affect the electro-optic properties. So the optimization of chiral dopant concentration in nematic liquid crystal leads to control the transmission of polarized light through the microscope. Hence transmission based polarizing optical microscope is used for the characterization of helical pitch length in the optical texture. The unwinding of helical pitch was observed with the application of electric field which affects the intensity of photoluminescence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative high dynamic range beam profiling for fluorescence microscopy

Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis system of submicron particle tracks in the fine-grained nuclear emulsion by a combination of hard x-ray and optical microscopy

Analyses of nuclear emulsion detectors that can detect and identify charged particles or radiation as tracks have typically utilized optical microscope systems because the targets have lengths from several μm to more than 1000 μm. For recent new nuclear emulsion detectors that can detect tracks of submicron length or less, the current readout systems are insufficient due to their poor resolution. In this study, we developed a new system and method using an optical microscope system for rough candidate selection and the hard X-ray microscope system at SPring-8 for high-precision analysis with a resolution of better than 70 nm resolution. Furthermore, we demonstrated the analysis of submicron-length tracks with a matching efficiency of more than 99% and position accuracy of better than 5 μm. This system is now running semi-automatically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic characterization of Au clusters in vapor-liquid-solid grown silicon nanowires

By correlating atom probe tomography with other conventional microscope techniques (scanning electron microscope, scanning transmission electron microscope, and scanning tunneling microscopy), the distribution and composition of Au clusters in individual vapor-liquid-solid grown Si nanowires is investigated. Taking advantage of the characteristics of atom probe tomography, we have developed a sample preparation method by inclining the sample at certain angle to characterize the nanowire sidewall without using focused ion beam. With three-dimensional atomic scale reconstruction, we provide direct evidence of Au clusters tending to remain on the nanowire sidewall rather than being incorporated into the Si nanowires. Based on the composition measurement of Au clusters (28% ± 1%), we have demonstrated the supersaturation of Si atoms in Au clusters, which supports the hypothesis that Au clusters are formed simultaneously during nanowire growth rather than during the cooling process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous differential spinning disk fluorescence optical sectioning microscopy and nanomechanical mapping atomic force microscopy

Combined microscopy techniques offer the life science research community a powerful tool to investigate complex biological systems and their interactions. Here, we present a new combined microscopy platform based on fluorescence optical sectioning microscopy through aperture correlation microscopy with a Differential Spinning Disk (DSD) and nanomechanical mapping with an Atomic Force Microscope (AFM). The illumination scheme of the DSD microscope unit, contrary to standard single or multi-point confocal microscopes, provides a time-independent illumination of the AFM cantilever. This enables a distortion-free simultaneous operation of fluorescence optical sectioning microscopy and atomic force microscopy with standard probes. In this context, we discuss sample heating due to AFM cantilever illumination with fluorescence excitation light. Integration of a DSD fluorescence optical sectioning unit with an AFM platform requires mitigation of mechanical noise transfer of the spinning disk. We identify and present two solutions to almost annul this noise in the AFM measurement process. The new combined microscopy platform is applied to the characterization of a DOPC/DOPS (4:1) lipid structures labelled with a lipophilic cationic indocarbocyanine dye deposited on a mica substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗