Review Article: Stress in thin films and coatings: Current status, challenges, and prospects

The issue of stress in thin films and functional coatings is a persistent problem in materials science and technology that has congregated many efforts, both from experimental and fundamental points of view, to get a better understanding on how to deal with, how to tailor, and how to manage stress in many areas of applications. With the miniaturization of device components, the quest for increasingly complex film architectures and multiphase systems and the continuous demands for enhanced performance, there is a need toward the reliable assessment of stress on a submicron scale from spatially resolved techniques. Also, the stress evolution during film and coating synthesis using physical vapor deposition (PVD), chemical vapor deposition, plasma enhanced chemical vapor deposition (PECVD), and related processes is the result of many interrelated factors and competing stress sources so that the task to provide a unified picture and a comprehensive model from the vast amount of stress data remains very challenging. This article summarizes the recent advances, challenges, and prospects of both fundamental and applied aspects of stress in thin films and engineering coatings and systems, based on recent achievements presented during the 2016 Stress Workshop entitled “Stress Evolution in Thin Films and Coatings: from Fundamental Understanding to Control.” Evaluation methods, implying wafer curvature, x-ray diffraction, or focused ion beam removal techniques, are reviewed. Selected examples of stress evolution in elemental and alloyed systems, graded layers, and multilayer-stacks as well as amorphous films deposited using a variety of PVD and PECVD techniques are highlighted. Based on mechanisms uncovered by in situ and real-time diagnostics, a kinetic model is outlined that is capable of reproducing the dependence of intrinsic (growth) stress on the grain size, growth rate, and deposited energy. The problems and solutions related to stress in the context of optical coatings, inorganic coatings on plastic substrates, and tribological coatings for aerospace applications are critically examined. This review also suggests strategies to mitigate excessive stress levels from novel coating synthesis perspectives to microstructural design approaches, including the ability to empower crack-based fabrication processes, pathways leading to stress relaxation and compensation, as well as management of the film and coating growth conditions with respect to energetic ion bombardment. Future opportunities and challenges for stress engineering and stress modeling are considered and outlined.

36 MATERIALS SCIENCE↗

Phase composition of polycrystalline HfNx (0.45 ≤ x ≤ 1.60) and effects of low-energy ion irradiation on microstructure, texture, and physical properties

We have investigated the phase composition of HfNx as a function of x and the effects of low-energy ion irradiation on the microstructure and physical properties of polycrystalline layers grown on SiO2 at 350 °C by ultrahigh vacuum reactive dc magnetron sputtering of Hf in mixed N2/Ar discharges. X-ray diffraction and Rutherford backscattering spectrometry results show that the phases obtained in polycrystalline HfNx layers with increasing x are hcp-structure α-Hf:N (x ≲ 0.6); multiphase mixtures consisting of α-Hf, NaCl-structure δ-HfN, rhombohedral ɛ-Hf3N2, and/or ζ-Hf4N3 (0.6 ≲ x ≲ 0.9); δ-HfN single phase (0.9 ≲ x ≲ 1.3); and mixtures of δ-HfN and higher nitrides (x ≳ 1.3). HfNx layers with 0.9 ≲ x ≲ 1.2 grown under mild ion irradiation (incident ion energy Ei ≃ 7 eV and ion-to-Hf flux ratios Ji/JHf = 1−3) are underdense with mixed orientation, low in-plane stress, and rough surface morphology due to limited adatom mobilities resulting in kinetic roughening and atomic shadowing during film growth. However, the use of intense ion irradiation (Ei = 25 eV and Ji/JHf = 4−20) results in HfNx layers, which are fully dense with strongly 111-oriented texture, compressive in-plane stress, and smooth surfaces due to ion irradiation enhanced adatom surface mobilities. In addition, the latter films have lower resistivity and higher hardness. For stoichiometric δ-HfN layers, ρ decreases from 69.7 to 35.2 μΩ cm and H increases from 22.1 to 27.4 GPa, with increasing ion-irradiation intensity. However, for HfNx layers with 1.2 ≲ x ≲ 1.6, the correspondingly higher steady state atomic N surface coverages during deposition alter growth kinetics in favor of 001 texture with a fully dense structure and compressive in-plane stress.

Materials Science↗

Recent developments in microtomography at GeoSoilEnviroCARS

A facility for x-ray computed microtomography (CMT) is operating as a national user facility for earth and environmental sciences research on the bending magnet beamline at the GeoSoilEnviroCARS sector at the Advanced Photon Source (APS). The APS bending magnet has a critical energy of 20 keV, and thus provides high flux at photon energies up to 100 keV, making it well suited to imaging a wide range of earth materials up to several cm in size. The beamline is equipped with a Si (111) double-crystal monochromator covering the energy range from 5 to 70 keV with beam sizes up to 50mm wide and 6mm high. The transmitted x-rays are imaged with a single crystal YAG or CdWO{sub 4} scintillator, a microscope objective and a 1300 x 1030 pixel 12-bit 5MHz CCD detector. The maximum spatial resolution is under 1.5 {micro}m in both the transmission radiographs and the reconstructed slices. Data collection times for full 3-D datasets range from 5-60 minutes. This facility has been used for a wide range of studies, including multiphase fluids in porous media, high-pressure studies, meteorites, and hyper-accumulating plants. We present recent technical improvements in the system, which include improved optics for samples larger than 5mm, significant reduction of ring artifacts, and correction of mechanical errors in the rotation stage.

43 PARTICLE ACCELERATORS↗

A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33{+-}0.16 mm (s.d.) in overall translation and 0.29 deg. {+-}0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34{+-}0.16 mm (s.d.), 0.40{+-}0.2 mm (s.d.), and 0.51{+-}0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multilevel learning-based segmentation of ill-defined and spiculated masses in mammograms

Purpose: A learning-based approach integrating the use of pixel-level statistical modeling and spiculation detection is presented for the segmentation of mammographic masses with ill-defined margins and spiculations. Methods: The algorithm involves a multiphase pixel-level classification, using a comprehensive group of features computed from regional intensity, shape, and textures, to generate a mass-conditional probability map (PM). Then, the mass candidate, along with the background clutters consisting of breast fibroglandular and other nonmass tissues, is extracted from the PM by integrating the prior knowledge of shape and location of masses. A multiscale steerable ridge detection algorithm is employed to detect spiculations. Finally, all the object-level findings, including mass candidate, detected spiculations, and clutters, along with the PM, are integrated by graph cuts to generate the final segmentation mask. Results: The method was tested on 54 masses (51 malignant and 3 benign), all with ill-defined margins and irregular shape or spiculations. The ground truth delineations were provided by five experienced radiologists. Area overlapping ratio of 0.689 ({+-}0.160) and 0.540 ({+-}0.164) were obtained for segmenting entire mass and margin portion only, respectively. Williams index of area and contour based measurements indicated that the segmentation results of the algorithm agreed well with the radiologists' delineation. Conclusions: The proposed approach could closely delineate the mass body. Most importantly, it is capable of including mass margin and its spicule extensions which are considered as key features for breast lesion analyses.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins. Comparison with 4D-CT in a clinical setting is warranted to assess the value of 4D-MRI in radiotherapy planning. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Automated selection of the optimal cardiac phase for single-beat coronary CT angiography reconstruction

Purpose: Reconstructing a low-motion cardiac phase is expected to improve coronary artery visualization in coronary computed tomography angiography (CCTA) exams. This study developed an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. The algorithm uses prospectively gated, single-beat, multiphase data made possible by wide cone-beam imaging. The proposed algorithm differs from previous approaches because the optimal phase is identified based on vessel image quality (IQ) directly, compared to previous approaches that included motion estimation and interphase processing. Because there is no processing of interphase information, the algorithm can be applied to any sampling of image phases, making it suited for prospectively gated studies where only a subset of phases are available. Methods: An automated algorithm was developed to select the optimal phase based on quantitative IQ metrics. For each reconstructed slice at each reconstructed phase, an image quality metric was calculated based on measures of circularity and edge strength of through-plane vessels. The image quality metric was aggregated across slices, while a metric of vessel-location consistency was used to ignore slices that did not contain through-plane vessels. The algorithm performance was evaluated using two observer studies. Fourteen single-beat cardiac CT exams (Revolution CT, GE Healthcare, Chalfont St. Giles, UK) reconstructed at 2% intervals were evaluated for best systolic (1), diastolic (6), or systolic and diastolic phases (7) by three readers and the algorithm. Pairwise inter-reader and reader-algorithm agreement was evaluated using the mean absolute difference (MAD) and concordance correlation coefficient (CCC) between the reader and algorithm-selected phases. A reader-consensus best phase was determined and compared to the algorithm selected phase. In cases where the algorithm and consensus best phases differed by more than 2%, IQ was scored by three readers using a five point Likert scale. Results: There was no statistically significant difference between inter-reader and reader-algorithm agreement for either MAD or CCC metrics (p > 0.1). The algorithm phase was within 2% of the consensus phase in 15/21 of cases. The average absolute difference between consensus and algorithm best phases was 2.29% ± 2.47%, with a maximum difference of 8%. Average image quality scores for the algorithm chosen best phase were 4.01 ± 0.65 overall, 3.33 ± 1.27 for right coronary artery (RCA), 4.50 ± 0.35 for left anterior descending (LAD) artery, and 4.50 ± 0.35 for left circumflex artery (LCX). Average image quality scores for the consensus best phase were 4.11 ± 0.54 overall, 3.44 ± 1.03 for RCA, 4.39 ± 0.39 for LAD, and 4.50 ± 0.18 for LCX. There was no statistically significant difference (p > 0.1) between the image quality scores of the algorithm phase and the consensus phase. Conclusions: The proposed algorithm was statistically equivalent to a reader in selecting an optimal cardiac phase for CCTA exams. When reader and algorithm phases differed by >2%, image quality as rated by blinded readers was statistically equivalent. By detecting the optimal phase for CCTA reconstruction, the proposed algorithm is expected to improve coronary artery visualization in CCTA exams.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom) measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant Support from: U01 CA181156.

60 APPLIED LIFE SCIENCES↗

Discovery of true electrochemical reactions for ultrahigh catalyst mass activity in water splitting

Better understanding of true electrochemical reaction behaviors in electrochemical energy devices has long been desired. It has been assumed so far that the reactions occur across the entire catalyst layer (CL), which is designed and fabricated uniformly with catalysts, conductors of protons and electrons, and pathways for reactants and products. By introducing a state-of-the-art characterization system, a thin, highly tunable liquid/gas diffusion layer (LGDL), and an innovative design of electrochemical proton exchange membrane electrolyzer cells (PEMECs), the electrochemical reactions on both microspatial and microtemporal scales are revealed for the first time. Surprisingly, reactions occur only on the CL adjacent to good electrical conductors. On the basis of these findings, new CL fabrications on the novel LGDLs exhibit more than 50 times higher mass activity than conventional catalyst-coated membranes in PEMECs. In conclusion, this discovery presents an opportunity to enhance the multiphase interfacial effects, maximizing the use of the catalysts and significantly reducing the cost of these devices.

08 HYDROGEN↗

Design of tough adhesive from commodity thermoplastics through dynamic crosslinking

Tough adhesives provide resistance against high debonding forces, and these adhesives are difficult to design because of the simultaneous requirement of strength and ductility. Here, we report a design of tough reversible/recyclable adhesive materials enabled by incorporating dynamic covalent bonds of boronic ester into commodity triblock thermoplastic elastomers that reversibly bind with various fillers and substrates. The spectroscopic measurements and density functional theory calculations unveil versatile dynamic covalent binding of boronic ester with various hydroxy-terminated surfaces such as silica nanoparticles, aluminum, steel, and glass. The designed multiphase material exhibits exceptionally high adhesion strength and work of debonding with a rebonding capability, as well as outstanding mechanical, thermal, and chemical resistance properties. Bonding and debonding at the interfaces dictate hybrid material properties, and this revelation of tailored dynamic interactions with multiple interfaces will open up a new design of adhesives and hybrid materials.

36 MATERIALS SCIENCE↗

The Stomatopod Dactyl Club: A Formidable Damage-Tolerant Biological Hammer

Nature has evolved efficient strategies to synthesize complex mineralized structures that exhibit exceptional damage tolerance. One such example is found in the hypermineralized hammer-like dactyl clubs of the stomatopods, a group of highly aggressive marine crustaceans. The dactyl clubs from one species, Odontodactylus scyllarus, exhibit an impressive set of characteristics adapted for surviving high-velocity impacts on the heavily mineralized prey on which they feed. Consisting of a multiphase composite of oriented crystalline hydroxyapatite and amorphous calcium phosphate and carbonate, in conjunction with a highly expanded helicoidal organization of the fibrillar chitinous organic matrix, these structures display several effective lines of defense against catastrophic failure during repetitive high-energy loading events.

36 MATERIALS SCIENCE↗

Giant piezoelectricity in oxide thin films with nanopillar structure

High-performance piezoelectric materials are critical components for electromechanical sensors and actuators. For more than 60 years, the main strategy for obtaining large piezoelectric response has been to construct multiphase boundaries, where nanoscale domains with local structural and polar heterogeneity are formed, by tuning complex chemical compositions. We used a different strategy to emulate such local heterogeneity by forming nanopillar regions in perovskite oxide thin films. We obtained a giant effective piezoelectric coefficient d 33 , f * of ~1098 picometers per volt with a high Curie temperature of ~450°C. Our lead-free composition of sodium-deficient sodium niobate contains only three elements (Na, Nb, and O). The formation of local heterogeneity with nanopillars in the perovskite structure could be the basis for a general approach to designing and optimizing various functional materials.

Science & Technology - Other Topics↗

Synthetic Methane-Consuming Communities from a Natural Lake Sediment

The factors and processes that influence the behavior and functionality of ecosystems inhabited by complex microbiomes are still far from being clearly understood. Synthetic microbial communities provide reduced-complexity models that allow an examination of ecological theories under defined and controlled conditions. In this study, we applied a multiphasic approach to study synthetic methane-oxidizing communities and species interactions as proxies to the natural communities. Our results confirm that, under selective pressures, natural-sediment communities of high complexity simplify rapidly, selecting for several major functional guilds, the major partners in methane oxidation being the Methylococcaceae methanotrophs and the Methylophilaceae methylotrophs, along with minor but persistent partners, members of Burkholderiales and Flavobacteriales. As a proof of concept, we established minimalist synthetic communities that were representative of the four functional guilds to demonstrate the dependency of the non-methane-utilizing species on the methanotrophs as the primary carbon-providing species. We observed that in communities consisting of multiple representatives of the key guilds, members of the same guild appeared to compete for resources. For example, when two methanotrophs of the same family were present, the two expressed similar key methanotrophy pathways and responded similarly to changing environmental conditions, suggesting that they perform a similar keystone function in situ. Similar observations were made for the Methylophilaceae. However, differences were noted in the expression of auxiliary and unique genes among strains of the same functional guild, reflecting differential adaptation and suggesting mechanisms for competition. At the same time, differences were also noted in the performances of partners with specific metabolic schemes. For example, a mutant of Methylotenera mobilis impaired in nitrate utilization behaved as a more efficient cooperator in methane consumption, suggesting that the loss of function may lead to changes in communal behavior. Overall, we demonstrate the robust nature of synthetic communities built of native lake sediment strains and their utility in addressing important ecological questions while using a simplified model.

54 ENVIRONMENTAL SCIENCES↗

Evenly spaced columns in the Bishop Tuff (California, USA) as relicts of hydrothermal cooling

A few square kilometers of the Bishop Tuff in eastern California (USA) have evenly spaced columns that are more resistant to erosion than the surrounding tuff owing to the precipitation of mordenite, a low-temperature (100-130 °C) zeolite. We hypothesize that the columns are a result of instabilities at the liquid water and steam interface as cold water seeped into the still-cooling Bishop Tuff. We use two methods to quantitatively assess this hypothesis. First, scaling shows which hydrodynamic instabilities exist in the system. Second, to account for the effects of multiphase flow, latent heat, and the finite amplitude and temporal evolution of these instabilities we use two-dimensional numerical models of liquid water infiltrating hot tuff. These tests highlight several features of boiling hydrothermal systems. (1) The geometry of at least some convection appears to be broadly captured by linear stability theory that neglects reactive transport, heterogeneity of the host rock, and the finite amplitude of instabilities. (2) Slopes > 10% set the wavelength of convection, meaning that these columns formed somewhere with relatively gentle topography. (3) For permeabilities of > 10 -13 m 2 , the wavelength of the instability changes through time, slowing infiltration, while for permeabilities < 10 -15 m 2 , cooling is dominated by conduction. The spacing and stability of columns increase with higher vertical permeability and decrease with higher horizontal permeability. These columns are a rare window into hydrothermal processes that may be widespread.

58 GEOSCIENCES↗

How does the connectivity of open-framework conglomerates within multi-scale hierarchical fluvial architecture affect oil-sweep efficiency in waterflooding?

Understanding multi-phase fluid flow and transport processes within aquifers, candidate reservoirs for CO 2 sequestration, and petroleum reservoirs requires understanding a diverse set of geologic properties of the aquifer or reservoir, over a wide range of spatial and temporal scales. We focus on multiphase flow dynamics with wetting (e.g., water) and non-wetting (e.g., gas or oil) fluids, with one invading another. This problem is of general interest in a number of fields and is illustrated here by considering the sweep efficiency of oil during a waterflood. Using a relatively fine-resolution grid throughout a relatively large domain in these simulations and probing the results with advanced scientific visualization tools (Reservoir Visualization Analysis [RVA]/ ParaView software) promote a better understanding of how smaller-scale features affect the aggregate behavior at larger scales. We studied the effects on oil-sweep efficiency of the proportion, hierarchical organization, and connectivity of high-permeability open-framework conglomerate (OFC) cross-sets within the multi-scale stratal architecture found in fluvial deposits. We further analyzed oil production rate, water breakthrough time, and spatial and temporal distribution of residual oil saturation. As expected, the effective permeability of the reservoir exhibits large-scale anisotropy created by the organization of OFC cross-sets within unit bars, and the organization of unit bars within compound- bars. As a result, oil-sweep efficiency critically depends on the direction of the pressure gradient. However, contrary to expectations, the total amount of trapped oil due to the effect of capillary trapping does not depend on the magnitude of the pressure gradient within the examined range. Hence the pressure difference between production and injection wells does not affect sweep efficiency; although the spatial distribution of oil remaining in the reservoir depends on this value. Whether or not clusters of connected OFC span the domain affects only the absolute rate of oil production—not sweep efficiency.

58 GEOSCIENCES↗

Similar quartz crystallographic textures in rocks of continental earth's crust (by neutron diffraction data): I. Quartz textures in monomineral rocks

Quartz crystallographic textures in different rocks have been investigated by neutron diffraction. Various types of crystallographic textures of quartz-bearing mineral associations in monomineral and multiphase rocks from a representative collection of samples have been revealed and classified. Experimental investigations have been performed on special neutron texture diffractometers designed at the Frank Laboratory of Neutron Physics and mounted in the seventh channel of the IBR-2 reactor at the Joint Institute for Nuclear Research (Dubna).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Similar quartz crystallographic textures in rocks of continental earth's crust (by neutron diffraction data): II. Quartz textures in monophase rocks

The types of quartz textures found in a large collection of multiphase rocks from different regions of the earth are analyzed. Crystallographic textures of granulite, amphibolite, slate, and gneiss samples are measured, classified, and compared with the similar textures of monomineral rocks.