Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Gamma bang time analysis at OMEGA

Absolute bang time measurements with the gas Cherenkov detector (GCD) and gamma reaction history (GRH) diagnostic have been performed to high precision at the OMEGA laser facility at the University of Rochester with bang time values for the two diagnostics agreeing to within 5 ps on average. X-ray timing measurements of laser-target coupling were used to calibrate a facility-generated laser timing fiducial with rms spreads in the measured coupling times of 9 ps for both GCD and GRH. Increased fusion yields at the National Ignition Facility (NIF) will allow for improved measurement precision with the GRH easily exceeding NIF system design requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORNL Radioactive Beams for Stellar Explosion Studies

At ORNL, we are using unique radioactive beams to measure scattering, transfer, and capture reactions to help understand exploding stars such as novae, supernovae, and X-ray bursts. Recent results have been obtained with beams of {sup 26}Al, {sup 17}F, and {sup 130,132}Sn, utilizing gas targets, silicon strip detectors, and recoil separators. More exciting work is planned at the future FRIB facility. We are also using synergistic nuclear data evaluations and the Computational Infrastructure for Nuclear Astrophysics to investigate the astrophysical impact of our measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stable coaxial-waveguide gyrotron backward-wave oscillator with distributed losses

This study analyzes the performance of a coaxial-waveguide gyrotron backward-wave oscillator (gyro-BWO) operating at the fundamental harmonic by considering mode competition, which may be attributed to higher-order axial modes and competing transverse modes. In the coaxial waveguide with a short length and uniform cross section, the threshold currents of the higher-order axial modes are substantially higher than the operating current. Additionally, when the beam voltage or the magnetic field is adjusted, the oscillation that neighbors the minimum start-oscillation current of a transverse mode has a positive-k{sub z} field profile, and is excited near the cutoff frequency. As a result, the distributed wall losses at the downstream end of the interaction structure effectively damp the positive-k{sub z} field, and raise significantly the minimum start-oscillation currents of the competing transverse modes. This study also investigates how the parameters, including lossy section length, outer wall resistivity, inner wall resistivity, and ratio of the outer radius to the inner radius, affect the start-oscillation currents of the competing transverse modes in order to obtain stable operation conditions in the frequency tuning range. As is forecasted, when using a 15 A electron beam, the Ka-band coaxial gyro-BWO produces an output power of 137 kW and 3 dB bandwidth of 4.2% by magnetic tuning and an output power of 145 kW and 3dB bandwidth of 2.0% by beam voltage tuning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Obliquely propagating generalized lower-hybrid drift instability with nonlocal two-fluid theory in current sheet equilibrium

By employing nonlocal two-fluid analysis, a class of obliquely propagating current sheet drift instabilities with frequency in the lower-hybrid frequency range is investigated. A series of unstable modes with multiple eigenstates are found by numerical simulation after electrostatic approximation. It is found that the growth rate of the unstable modes, whose eigenfunctions are localized at the current sheet edge, increases as the propagation more oblique. However, as the wave vector attains more and more field-aligned components, the maximum growth rate suffers an acute drop after a certain critical angle, beyond which it finally diminishes. On the other hand, the growth rate associated with modes located near the center of the current sheet is found to be less sensitive to the increase in propagation angle, although it does undergo a gradual decrease until it is stabilized when the mode becomes near-field aligned.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially resolvable optical emission spectrometer for analyzing density uniformity of semiconductor process plasma

We proposed a spatially resolved optical emission spectrometer (SROES) for analyzing the uniformity of plasma density for semiconductor processes. To enhance the spatial resolution of the SROES, we constructed a SROES system using a series of lenses, apertures, and pinholes. We calculated the spatial resolution of the SROES for the variation of pinhole size, and our calculated results were in good agreement with the measured spatial variation of the constructed SROES. The performance of the SROES was also verified by detecting the correlation between the distribution of a fluorine radical in inductively coupled plasma etch process and the etch rate of a SiO{sub 2} film on a silicon wafer.

36 MATERIALS SCIENCE↗

Stabilization of sample temperature in a surface-science vacuum chamber to 0.03 K and quartz-crystal microbalance frequency to 0.06 Hz over 0.5 h

Improvements have been made to a high-stability quartz-crystal microbalance for use in a typical surface-science, ultrahigh vacuum chamber, with a frequency stability of one part in 10{sup 8} (0.06 Hz) over 0.5 h. This gives a resolution equivalent to 2% of an atomic monolayer of oxygen over 0.5 h. The quartz-crystal microbalance (QCM) crystal can be rotated to different surface-analysis positions in the chamber. These characteristics open up the combination of surface and bulk adsorption studies on the same sample without transferring the sample to another chamber. To accomplish this, it was necessary to stabilize the sample temperature to {+-}0.03 K over several hours. The oscillator performance is illustrated by the uptake of oxygen by a gold-plated QCM crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction

We have developed a compact streak camera suitable for measuring the duration of highly charged subrelativistic femtosecond electron bunches with an energy bandwidth in the order of 0.1%, as frequently used in ultrafast electron diffraction (UED) experiments for the investigation of ultrafast structural dynamics. The device operates in accumulation mode with 50 fs shot-to-shot timing jitter, and at a 30 keV electron energy, the full width at half maximum temporal resolution is 150 fs. Measured durations of pulses from our UED gun agree well with the predictions from the detailed charged particle trajectory simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broken ergodicity in two-dimensional homogeneous magnetohydrodynamic turbulence

Two-dimensional (2D) homogeneous magnetohydrodynamic (MHD) turbulence has many of the same qualitative features as three-dimensional (3D) homogeneous MHD turbulence. These features include several ideal (i.e., nondissipative) invariants along with the phenomenon of broken ergodicity (defined as nonergodic behavior over a very long time). Broken ergodicity appears when certain modes act like random variables with mean values that are large compared to their standard deviations, indicating a coherent structure or dynamo. Recently, the origin of broken ergodicity in 3D MHD turbulence that is manifest in the lowest wavenumbers was found. Here, we study the origin of broken ergodicity in 2D MHD turbulence. It will be seen that broken ergodicity in ideal 2D MHD turbulence can be manifest in the lowest wavenumbers of a finite numerical model for certain initial conditions or in the highest wavenumbers for another set of initial conditions. The origins of broken ergodicity in an ideal 2D homogeneous MHD turbulence are found through an eigenanalysis of the covariance matrices of the probability density function and by an examination of the associated entropy functional. When the values of ideal invariants are kept fixed and grid size increases, it will be shown that the energy in a few large modes remains constant, while the energy in any other mode is inversely proportional to grid size. Also, as grid size increases, we find that broken ergodicity becomes manifest at more and more wavenumbers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High accuracy wavelength calibration for a scanning visible spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies {<=}0.2 A. An automated calibration, which is stable over time and environmental conditions without the need to recalibrate after each grating movement, was developed for a scanning spectrometer to achieve high wavelength accuracy over the visible spectrum. This method fits all relevant spectrometer parameters using multiple calibration spectra. With a stepping-motor controlled sine drive, an accuracy of {approx}0.25 A has been demonstrated. With the addition of a high resolution (0.075 arc sec) optical encoder on the grating stage, greater precision ({approx}0.005 A) is possible, allowing absolute velocity measurements within {approx}0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal symmetry of individual filaments in different spatial symmetry filaments pattern in a dielectric barrier discharge

The temporal behavior of individual filament in different spatial symmetry filaments patterns in dielectric barrier discharge is investigated by using an optical method. A series of return maps of the discharge moments of individual filaments is given. It is found that the temporal symmetry of individual filament changes with the change of the spatial symmetry of filaments pattern as the applied voltage increases. The role of wall charges for this phenomenon is analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Symmetries, weak symmetries, and related solutions of the Grad-Shafranov equation

We discuss a new family of solutions of the Grad-Shafranov (GS) equation that describes D-shaped toroidal plasma equilibria with sharp gradients at the plasma edge. These solutions have been derived by exploiting the continuous Lie symmetry properties of the GS equation and in particular a special type of 'weak' symmetries. In addition, we review the continuous Lie symmetry properties of the GS equation and present a short but exhaustive survey of the possible choices for the arbitrary flux functions that yield GS equations admitting some continuous Lie symmetry. Particular solutions related to these symmetries are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

36 MATERIALS SCIENCE↗

Superresolution confocal technology for displacement measurements based on total internal reflection

In order to achieve a higher axial resolution for displacement measurement, a novel method is proposed based on total internal reflection filter and confocal microscope principle. A theoretical analysis of the basic measurement principles is presented. The analysis reveals that the proposed confocal detection scheme is effective in enhancing the resolution of nonlinearity of the reflectance curve greatly. In addition, a simple prototype system has been developed based on the theoretical analysis and a series of experiments have been performed under laboratory conditions to verify the system feasibility, accuracy, and stability. The experimental results demonstrate that the axial resolution in displacement measurements is better than 1 nm in a range of 200 nm which is threefold better than that can be achieved using the plane reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed digital holography for density and fluctuation measurements (invited)

The state of the art in electro-optics has advanced to the point where digital holographic acquisition of wavefronts is now possible. Holographic wavefront acquisition provides the phase of the wavefront at every measurement point. This can be done with accuracy on the order of a thousandth of a wavelength, given that there is sufficient care in the design of the system. At wave frequencies which are much greater than the plasma frequency, the plasma index of refraction is linearly proportional to the electron density and wavelength, and the measurement of the phase of a wavefront passing through the plasma gives the chord-integrated density directly for all points measured on the wavefront. High-speed infrared cameras (up to {approx}40 000 fps at {approx}64x4 pixels) with resolutions up to 640x512 pixels suitable for use with a CO{sub 2} laser are readily available, if expensive.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Traveling wave model for laser-guided discharges

We present an easily solvable 1D traveling wave model for laser-guided discharges. By assuming constant propagation speed u, the hydro/electrodynamic/chemistry equations are reduced to ordinary differential equations in retarded time {tau}. Negative discharges are shown to propagate only if u>{mu}E{sub b}, where {mu} is electron mobility and E{sub b} is the breakdown field; positive discharges propagate only if the channel preconductance exceeds {approx}6x10{sup -11} m/{Omega}. The axial electric field E is shown to spike up to several times E{sub b} and then relax to {approx}E{sub b} for as long as the gas remains cold. In this streamer region, the channel conductance, current, and potential all increase linearly with {tau}. The transition to the leader stage, where E is much smaller, occurs in two steps: excitation of vibrational and low-lying electronic states, then gas heating. The propagation range decreases as a function of initial radius and (for given maximum voltage) of the voltage rise rate. Expansion of the hot channel is shown to increase the range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous measurement of ultrasonic longitudinal wave velocities and thicknesses of a two layered media in the absence of an interface echo

A measurement technique has been developed to extract the phase information of successive echoes for the simultaneous estimation of thicknesses and ultrasonic velocities of individual layers in a two layered media. The proposed method works in the absence of an interface echo and requires the total thickness of the sample to be known. Experiments have been carried out on two layered samples of white cast iron and gray cast iron with layer thickness variation in the range of 2-8 mm for total thickness variation in the range of 12-13 mm. Comparison with micrographs of a few samples confirmed the model predictions. The model is found to be sensitive to the total sample thickness but fairly insensitive to noise in the data.

36 MATERIALS SCIENCE↗

Note: A robust low-cost high-sensitivity subangstrom bidirectional displacement sensor

The design of a simple, robust, low-cost, and bidirectional displacement sensor with subangstrom resolution is described. A small gold plate is attached to the object, whose displacement is to be measured, and a small gold tip is brought into contact with the plate, establishing a reference current between the two. Movements of the gold plate away from the tip lead to a change in the tip-plate current; the reference current is then re-established by moving the tip using a simple magnetic actuator. The resolution of the sensor has been calibrated using an interferometer and was shown to be as high as 0.3 A per system count. Potential applications of the sensor are numerous, including microbar air pressure measurement, motion and infrasound detection, thermal sensing, and gravitational field and relativistic gravity wave measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

From extended phase space dynamics to fluid theory

We derive a fluid theory for spin-1/2 particles starting from an extended kinetic model based on a spin-projected density matrix formalism. The evolution equation for the spin density is found to contain a pressurelike term. We give an example where this term is important by looking at a linear mode previously found in a spin kinetic model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗