Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

ROPEC - ROtary PErcussive Coring Drill for Mars Sample Return

The ROtary Percussive Coring Drill is a light weight, flight-like, five-actuator drilling system prototype designed to acquire core material from rock targets for the purposes of Mars Sample Return. In addition to producing rock cores for sample caching, the ROPEC drill can be integrated with a number of end effectors to perform functions such as rock surface abrasion, dust and debris removal, powder and regolith acquisition, and viewing of potential cores prior to caching. The ROPEC drill and its suite of end effectors have been demonstrated with a five degree of freedom Robotic Arm mounted to a mobility system with a prototype sample cache and bit storage station.

Chu, Philip↗

Design by analysis rules for ASME Section III, Division 5, Class B components

The current rules for elevated temperature ASME Section III, Division 5, Class B components, other than piping, were basically adapted from the Design-by-Rule approach for Section VIII, Division 1 vessels. A goal of the proposed new rules is to explicitly account for the design life and cyclic service while recognizing the less-rigorous requirements commensurate with lesser safety consideration. Further goals are to maximize the use of modern computational technology, for example finite element analysis in conjunction with reference stress concepts, and to avoid the need for stress classification. This paper summarizes the work done to address these issues. A summary of the design-by-analysis for primary loads, strain limit evaluation, and creep-fatigue damage assessment is presented. The proposed design-by-analysis creep-fatigue damage calculation approach uses a new elastic follow-up-based Isochronous Stress Strain Curve stress relaxation procedure. A set of sample problems are selected to validate the proposed design-by-analysis rules for creep-fatigue damage assessment. The proposed Class B rules are evaluated against the Class A elastic design rules and the experimental data obtained from a family of a simplified model test-based key-feature test results. The proposed Class B creep-fatigue damage assessment methodology yields conservative design cycles estimates compared to the experimental results.

36 MATERIALS SCIENCE↗

Computed Tomography Support for Microgravity Materials Science Experiments

The accurate measurement of density in both liquid and solid samples is of considerable interest to Principal Investigators with materials science experiments slated for the ISS. The work to be described is an innovative application of a conventional industrial nondestructive evaluation instrument. Traditional applications of industrial computed tomography (CT) rely on reconstructing cross sections of large structures to provide two-dimensional planar views which can identify defects such as porosity, or other material anomalies. This has been done on microgravity materials science experiments to check the integrity of ampoule-cartridge assemblies for safety purposes. With a substantially monoenergetic flux, as can be obtained with a radioactive cobalt source, there will be a direct correlation between absorption and density. Under such conditions it then becomes possible to make accurate measurements of density throughout a sample, and even when the sample itself is enclosed within a furnace and a safety required cartridge. Such a system has been installed at Kennedy Space Center (KSC) and is available to PIs to examine samples before and after flight. The CT system is being used to provide density information for two purposes. Firstly, the determination of density changes from liquid to solid is vital information to the PI for purposes of modeling the solidification behavior of his sample, and to engineers who have to design containment ampoules and must allow for shrinkage and other volume changes that may occur during processing. While such information can be obtained by pycnometric measurements, the possibility of using a furnace installed on the CT system enables one to examine potentially dangerous materials having high vapor pressures, while not needing visible access to the material. In addition, uniform temperature can readily be obtained, and the system can be controlled to ramp up, hold, and ramp down while collecting data over a wide range of parameters automatically. Results of initial tests on low melting point elements such as gallium, indium and tin will be presented, and the intent is to proceed to compounds such as InSb, HgCdTe and CdTe. Alloys such as Pb-Sb (PI - Poirier, U AZ) and Cu-Al (PI - Trivedi, Ames Lab.), which are the subjects of flight experiments, will also be examined. The second application is the conversion of measured density values directly to composition. This was successfully done with the mercury cadmium telluride alloys grown on the second and fourth United States Microgravity Payload (USMP-2 and USMP-4) missions by Lehoczky. CdTe values along the length of the boules were obtained at KSC prior to cutting the sample, and could have been obtained prior to its removal from the cartridge and ampoule. Examples of the data obtained will be shown. It is anticipated that several of the materials science PIs will avail themselves of the technique described, initially for determining densities prior to flight, and then to acquire early quantitative data on the compositional variation within their samples.

Gillies, Donald C.↗

Mars rover vehicle

This year the University of Wisconsin-Madison design team studied surface operations for a Mars base. Specifically, research was conducted concerning the possibilities for a Mars Rover Sample Return mission. This year's focus was on the development of a system that would accomplish the primary tasks of the rover, to gather and return samples. All the aspects of this complex and challenging task were investigated. In order to achieve a complete system devices were designed for every stage from sample acquisition to processing and final storage.

Source record↗

Laboratory-Based Cryogenic Soft X-ray Tomography with Correlative Cryo-Light and Electron Microscopy

Here we present a novel laboratory-based cryogenic soft X-ray microscope for whole cell tomography of frozen hydrated samples. We demonstrate the capabilities of this compact cryogenic microscope by visualizing internal sub-cellular structures of Saccharomyces cerevisiae cells. The microscope is shown to achieve better than 50 nm spatial resolution with a Siemens star test sample. For whole biological cells, the microscope can image specimens up to 5 micrometers thick. Structures as small as 90 nm can be detected in tomographic reconstructions at roughly 70 nm spatial resolution following a low cumulative radiation dose of only 7.2 MGy. Furthermore, the design of the specimen chamber utilizes a standard sample support that permits multimodal correlative imaging of the exact same unstained yeast cell via cryo-fluorescence light microscopy, cryo-soft x-ray microscopy and cryo-transmission electron microscopy. This completely laboratory-based cryogenic soft x-ray microscope will therefore enable greater access to three-dimensional ultrastructure determination of biological whole cells without chemical fixation or physical sectioning.

Compact light source↗

Analysis of Integrated Spacecraft Performance Using A Rotating Detonation Rocket Engine

For spacecraft with especially stringent mass fraction constraints, the use of a rotating detonation rocket engine (RDRE) may yield potentially significant system mass savings. The pressure gain combustion inherent to RDREs provides higher thrust than traditional rocket engines for a given supply pressure and throat area. This opens multiple avenues for reducing system mass via higher specific impulse, reduced gravity losses, and reduced feed pressures. To highlight the potentially weight-saving characteristics of RDRE systems, the integrated performance of representative spacecraft designs using either a conventional rocket engine or an RDRE was assessed. This paper details the assumptions, methods, and results of this trade study. Two representative spacecraft were assessed. The first is a Liquid Mars Ascent Vehicle (MAV). This spacecraft was designed by NASA in 2011 for the Mars Sample Return Campaign but was not selected for flight due in part to it exceeding the mass requirements by 119 lbm. The second is MIURA-1, a kerolox sounding rocket developed by Payload Aerospace S.L.. The Liquid MAV assessment showed that an RDRE powered design met the mass requirements with a total vehicle mass 46 lbm below the limit. The MIURA-1 assessment showed that wall heat transfer and regenerative cooling are significant challenges for kerolox RDREs, but these challenges may be mitigated by reducing mixture ratio and using both propellants to cool the chamber. The assessment showed that an RDRE powered sounding rocket could achieve 12% more microgravity time than a conventional sounding rocket with the same payload and total vehicle mass. Alternately, if the payload mass and target apogee are held constant, then an RDRE powered sounding rocket can be 8% shorter and 11% lighter than a conventional sounding rocket. These results suggest that the advent of RDREs for in-space propulsion may unlock new missions for which conventional propulsion is not feasible.

Rotating Detonation Rocket Engine↗

Analysis of Integrated Spacecraft Performance Using Rotating Detonation Rocket Engine

For spacecraft with especially stringent mass fraction constraints, the use of a rotating detonation rocket engine (RDRE) may yield potentially significant system mass savings. The pressure gain combustion inherent to RDREs provides higher thrust than traditional rocket engines for a given supply pressure and throat area. This opens multiple avenues for reducing system mass via higher specific impulse, reduced gravity losses, and reduced feed pressures. To highlight the potentially weight-saving characteristics of RDRE systems, the integrated performance of representative spacecraft designs using either a conventional rocket engine or an RDRE was assessed. This paper details the assumptions, methods, and results of this trade study. Two representative spacecraft were assessed. The first is a Liquid Mars Ascent Vehicle (MAV). This spacecraft was designed by NASA in 2011 for the Mars Sample Return Campaign but was not selected for flight due in part to it exceeding the mass requirements by 119 lbm. The second is MIURA-1, a kerolox sounding rocket developed by Payload Aerospace S.L.. The Liquid MAV assessment showed that an RDRE powered design met the mass requirements with a total vehicle mass 46 lbm below the limit. The MIURA-1 assessment showed that wall heat transfer and regenerative cooling are significant challenges for kerolox RDREs, but these challenges may be mitigated by reducing mixture ratio and using both propellants to cool the chamber. The assessment showed that an RDRE powered sounding rocket could achieve 12% more microgravity time than a conventional sounding rocket with the same payload and total vehicle mass. Alternately, if the payload mass and target apogee are held constant, then an RDRE powered sounding rocket can be 8% short and 11% lighter than a conventional sounding rocket. These results suggest that the advent of RDREs for in-space propulsion may unlock new missions for which conventional propulsion is not feasible.

Rotating Detonation Rocket Engine↗

Oceanographic biooptical profiling system

A new oceanographic instrument to measure underwater optical, biological, and physical properties has been designed, built, and used extensively at sea. The new instrument system is a significant advance that permits optimum sampling strategies using ship, aircraft, and satellite optical sensors for ocean research. The design criteria for the biooptical profiling system included the rapid acquisition of data to accommodate shipboard synoptic sampling; the measurement of the necessary parameters for providing appropriate contemporaneous surface data for remote sensors; the compatibility of the data acquisition system with conventional conductivity temperature depth-type cables and winches on the oceanographic fleet; the capability of real-time display of data along with rapid preliminary data reduction at sea. The primary instrument package in this profiling system is a new microprocessor controlled multiwavelength spectroradiometer. A description of the instrument and examples of data are presented.

Smith, R. C.↗

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science↗

tbsinp (00)

The ice nucleation spectrometer (INS) is an offline analytical measurement system used to process filter samples for freezing temperature spectra of immersion-mode ice-nucleating particle (INP) number concentrations. It is almost identical to the Colorado State University (CSU) ice spectrometer design. The INS-AIR is specific to filter samples collected on aerial platforms, such as the DOE ARM tethered balloon system (TBS) operated by Sandia National Laboratories, using miniaturized aerosol filter samplers. Users are referred to the INS instrument handbook for INS-AIR sampler details. INS-AIR filter samples are collected during intensive operational periods at various ARM sites and then processed on the INS at CSU. This filter log contains the detailed metadata at all ARM sites where INP filter sample collection has occurred or is currently ongoing, including both ground-based routine INP sampling (INS) and TBS INP sampling (INS-AIR). Metadata include start and end times, vacuum line pressures and temperatures, and flow rates; total accumulated flow through each filter; and notes on collection issues or weather conditions. Users can also keep up to date with the status of filter and data processing, even before data are available on ARM’s Data Discovery. Users can contact INP mentors Jessie Creamean or Thomas Hill with any questions.

54 ENVIRONMENTAL SCIENCES↗

IR Thermographic Analysis of 3D Printed CFRP Reference Samples with Back-Drilled and Embedded Defects

Carbon-fiber composite structures may demonstrate a defective behavior due to manufacturing induced anomalies (delamination, dis-bonds) or service related defectives (impact damage, water ingress). Thus, there is a need for a relatively fast and low cost non-intrusive testing schemes such as infrared thermography (IRT). Still, thermography testing requires calibrated samples and coupons to yield best results. The presented research demonstrates the novel use of 3D printing technology to generate IRT calibration samples. In this text, two carbon fiber reinforced polymer samples are 3D printed; the first mimics a 'back-drilled holes' type coupons, while the other is designed to embed air pockets similar to Teflon inserts. The generated samples are then tested using two IRT modalities; namely pulse thermography and lock-in thermography. Furthermore, the resulted thermograms are processed using a principle component analysis, to help highlight the variance of defectives in a consistent manner among the samples. This research findings offer insights on the variation of detectability between embedded and back-printed samples, which might be due to the inserts thickness.

36 MATERIALS SCIENCE↗

Multimodality in the Search for New Physics in Pulsar Timing Data and the Case of Kination-amplified Gravitational-wave Background from Inflation

We investigate the kination-amplified inflationary gravitational-wave background (GWB) interpretation of the signal recently reported by various pulsar timing array (PTA) experiments. Kination is a post-inflationary phase in the expansion history dominated by the kinetic energy of some scalar field, characterized by a stiff equation of state w = 1. Within the inflationary GWB model, we identify two modes that can fit the current data sets (NANOGrav and EPTA) with equal likelihood: the kination-amplification (KA) mode and the ordinary, no-kination-amplification (no-KA) mode. The multimodality of the likelihood motivates a Bayesian analysis with nested sampling. We analyze the free spectra of current PTA data and mock free spectra constructed with higher signal-to-noise ratios using nested sampling. The analysis of the mock spectrum designed to be consistent with the best fit to the NANOGrav 15 yr (NG15) data successfully reveals the expected bimodal posterior for the first time while excluding the reheating mode that appears in the fit to the current NG15 data, making a case for our correct and comprehensive treatment of potential multimodal posteriors arising from future PTA data sets. The resultant Bayes factor is $\mathcal{B}$ $\equiv$ Z no–KA /Z KA = 2.9 ± 1.9, indicating comparable statistical significance between the two modes. Given the theoretical model-building challenges of producing highly blue-tilted primordial tensor spectra, the KA mode has the advantage of requiring less blue primordial spectra, compared with the no-KA mode. The synergy between future cosmic microwave background polarization, pulsar timing, and laser interferometer measurements of gravitational waves will help resolve the ambiguity implied by the multimodal posterior in PTA-only searches.

Cosmology↗

Human Performance Contributions to Safety in Commercial Aviation

Every day in aviation, pilots, air traffic controllers, and other front-line personnel perform countless correct judgments and actions in a variety of operational environments. These judgments and actions are often the difference between an accident and a non-event. Ironically, data on these behaviors are rarely collected or analyzed. Data-driven decisions about safety management and design of safety-critical systems are limited by the available data, which influence how decision makers characterize problems and identify solutions. Large volumes of data are collected on the failures and errors that result in infrequent incidents and accidents, but in the absence of data on behaviors that result in routine successful outcomes, safety management and system design decisions are based on a small sample of nonrepresentative safety data. This assessment aimed to find and document “safety successes” made possible by human operators. With many Aeronautics Research Mission Directorate (ARMD) Programs and Projects focusing on increased automation and autonomy and decreased human involvement, failure to fully consider the human contributions to successful system performance in civil aviation represents a significant risk — a risk that has not been recognized to date. Without understanding how humans contribute to safety, any estimate of predicted safety of autonomous capabilities is incomplete and inherently suspect. Furthermore, understanding the ways in which humans contribute to safety can promote strategic interactions among safety technologies, functions, procedures and the people using them. Without this understanding, the full benefits of an integrated, optimized human/technology or autonomous system will not be realized. Historically, safety has been consistently defined in terms of the occurrence of accidents or recognized risks (i.e., in terms of things that go wrong). These adverse outcomes are explained by identifying their causes, and safety is restored by eliminating or mitigating these causes. An alternative to this approach is to focus on what goes right and identify how to replicate that process. Focusing on the rare cases of failures attributed to “human error” provides little information about why human performance routinely prevents adverse events. Hollnagel has proposed that things go right because people continuously adjust their work to match their operating conditions. These adjustments become increasingly important as systems continue to grow in complexity. Thus, the definition of safety should reflect not only “avoiding things that go wrong” but “ensuring that things go right.” The basis for safety management requires developing an understanding of everyday activities. However, few mechanisms to monitor everyday work exist in the aviation domain, which limits opportunities to learn how designs function in reality. This concept of safety thinking and safety management is reflected in the emerging field of resilience engineering. According to Hollnagel, a system is resilient if it can sustain required operations under expected and unexpected conditions by adjusting its functioning prior to, during, or following changes, disturbances, and opportunities. To explore “positive” behaviors that contribute to resilient performance in commercial aviation, the assessment team examined a range of existing sources of data about pilot and air traffic control (ATC) tower controller performance, including subjective interviews with domain experts and objective aircraft flight data records. These data were used to identify strategies that support resilient performance, methods for exploring and refining those strategies in existing data, and proposed methods for capturing and analyzing new data.

Null, Cynthia H.↗

NASA 9-Point LDI Code Validation Experiment

This presentation highlights the experimental work to date to obtain validation data using a 9-point lean direct injector (LDI) in support of the National Combustion Code. The LDI is designed to supply fuel lean, Jet-A and air directly into the combustor such that the liquid fuel atomizes and mixes rapidly to produce short flame zones and produce low levels of oxides of nitrogen and CO. We present NOx and CO emission results from gas sample data that support that aspect of the design concept. We describe this injector and show high speed movies of selected operating points. We present image-based species maps of OH, fuel, CH and NO obtained using planar laser induced fluorescence and chemiluminescence. We also present preliminary 2-component, axial and vertical, velocity vectors of the air flow obtained using particle image velocimetry and of the fuel drops in a combusting case. For the same combusting case, we show preliminary 3-component velocity vectors obtained using a phase Doppler anemometer. For the fueled, combusting cases especially, we found optical density is a technical concern that must be addressed, but that in general, these preliminary results are promising. All optical-based results confirm that this injector produces short flames, typically on the order of 5- to-7-mm long at typical cruise and high power engine cycle conditions.

Hicks, Yolanda R.↗

Risk Analysis and System Trades inthe Mars Sample Return (MSR) Mission

Risk Managenent advocates have long sought to directly influence the early stages of the systems engineering process through a more effective role in system design trade studies. The principal obstacle to this has been the lack of credible ways to represent and quantify mission risk that is, missios return form a probablistic viewpoint-for the project manager and the rest of the design team.

Risk Analysis Mars Sample Return↗

Fast imaging diagnostics on the C-2U advanced beam-driven field-reversed configuration device

The C-2U device employed neutral beam injection, end-biasing, and various particle fueling techniques to sustain a Field-Reversed Configuration (FRC) plasma. As part of the diagnostic suite, two fast imaging instruments with radial and nearly axial plasma views were developed using a common camera platform. To achieve the necessary viewing geometry, imaging lenses were mounted behind re-entrant viewports attached to welded bellows. During gettering, the vacuum optics were retracted and isolated behind a gate valve permitting their removal if cleaning was necessary. The axial view incorporated a stainless-steel mirror in a protective cap assembly attached to the vacuum-side of the viewport. For each system, a custom lens-based, high-throughput optical periscope was designed to relay the plasma image about half a meter to a high-speed camera. Each instrument also contained a remote-controlled filter wheel, set between shots to isolate a particular hydrogen or impurity emission line. The design of the camera platform, imaging performance, and sample data for each view is presented.

43 PARTICLE ACCELERATORS↗

A satellite digital controller or 'play that PID tune again, Sam'

The problem discussed is to design a digital controller for a typical satellite. The controlled plant is considered to be a rigid body acting in a plane. The controller is assumed to be a digital computer which, when combined with the proposed control algorithm, can be represented as a sampled-data system. The objective is to present a design strategy and technique for selecting numerical values for the control gains (assuming position, integral, and derivative feedback) and the sample rate. The technique is based on the parameter plane method and requires that the system be amenable to z-transform analysis.

Seltzer, S. M.↗