At least 1,783 records · Page 99

Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical optical quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.

47 OTHER INSTRUMENTATION↗

Global fire modelling and control attributions based on the ensemble machine learning and satellite observations

Contemporary fire dynamics is one of the most complex and least understood land surface phenomena. Global fire controls related to climate, vegetation, and anthropogenic activity are usually intertwined, and difficult to disentangle in a quantitative way. Here, we leveraged an ensemble of five machine learning (ML) models and multiple satellite-based observations to conduct global fire modeling for three fire metrics (burned area, fire number, and fire size), and quantified driving mechanisms underlying annual fire changes in a spatially resolved manner for the period 2003–2019. Ensemble learning is a meta-approach that combines multiple ML predictions to improve accuracy, robustness, and generalization performance. We found that the optimized ensemble ML well reproduced annual dynamics of global burned area (R 2 = 0.90, P < 0.001), total fire numbers (R 2 = 0.86, P < 0.001), and averaged fire size (R 2 = 0.70, P < 0.001). Additionally, the ensemble ML captured key spatial patterns of multi-year mean magnitudes, annual variabilities, anomalies, and trends for different fire metrics. Our ML-based fire attributions further highlighted the dominant role of enhanced anthropogenic activity in reducing global burned area (–1.9 Mha/yr, P < 0.01), followed by climate control (–1.3 Mha/yr, P < 0.01) and insignificant positive vegetation control (0.4 Mha/yr, P = 0.60). Spatially, climate dominated a much larger burned area (53.7%) than human (23.4%) or vegetation control (22.9%); however, the counteracting effects from regional wetting and drying trends weakened the net climate impacts on global burned area. The fire number and fire size exhibited similar spatial control patterns with burned area; globally, however, fire number tended to be more affected by climate while fire size more influenced by human activities. Overall, our study confirmed the feasibility and efficiency of ensemble ML in global fire modeling and subsequent control attributions, providing a better understanding of contemporary fire regimes and contributing to robust fire projections in a changing environment.

54 ENVIRONMENTAL SCIENCES↗

IonCCD™ for direct position-sensitive charged-particle detection: from electrons and keV ions to hyperthermal biomolecular ions

A novel charged-particle sensitive, pixel based detector array is described and its usage is demonstrated for a variety of applications, from detection of elemental particles (electrons) to hyper-thermal large biomolecular positive and negative ions including keV light atomic and molecular ions. The array detector is a modified light-sensitive charged coupled device (CCD). The IonCCDTM was engineered for direct charged particle detection by replacing the semi-conductor part of the CCD pixel by a conductor1. In contrast with the CCD, where the semi-conductive pixel is responsible for electron-hole pair formation upon photon bombardment, the IonCCD uses a capacitor coupled to the conductive electrode for direct charge integration. The detector can be operated from atmospheric pressure to high vacuum since no high voltages are needed. The IonCCD, presented in this work is an array of 2126 active pixels with 21 um pixel width and 3 um pixel gap. The detection area is 1.5x51mm2 where 1.5 mm and 51 mm are pixel and detector array length, respectively. The result is a one-dimensional position-sensitive detector with 24 um spatial resolution and 88 % pixel area ratio (PAR). In this work we demonstrate the capabilities and the performance of the detector. For the first time we show the direct detection of 250 eV electrons providing linearity response and detection efficiency of the IonCCD as function of electron beam current. Using positive ions from and electron impact source (E-I), we demonstrate that the detection efficiency of the IonCCD is virtually independent of particle energy [250 eV, 1250 eV], particle impact angle [45o, 90o] and particle flux. By combining the IonCCD with a double focusing sector field of Mattauch-Herzog geometry (M-H), we demonstrate fast acquisition of mass spectra in direct air sniffing mode. A first step towards fast in vivo breath analysis is presented. Detection of hyper-thermal biomolecular ions produced using an electrospray ionization source (ESI) is presented. The IonCCD was used as beam profiler to characterize the beam shape and intensity of 15 eV protonated and deprotonated biomolecular ions at the exit of an RF only collisional quadrupole. We present simultaneous detection of 140 eV doubly protonated biomolecular ions when the IonCCD is combined with the M-H analyzer. The latter, demonstrates the possibility of simultaneous separation and micro-array deposition of biological material using a miniature sector field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral and spatial analysis of the dark matter subhalo candidates among Fermi Large Area Telescope unidentified sources

Fermi -LAT unidentified sources (unIDs) have proven to be compelling targets for performing indirect dark matter (DM) searches. In a previous work, we found that among the 1235 unIDs in Fermi -LAT's catalogs (3FGL, 2FHL and 3FHL) only 44 of those are DM subhalos candidates. In the present work, we implement a spectral analysis to test whether these remaining sources are compatible or not with DM origin. This analysis is executed using almost 10 years of Pass 8 Fermi -LAT data. None of the unIDs are found to significantly prefer DM-induced emission compared to other, more conventional, astrophysical sources. In order to discriminate between pulsar and DM sources, we developed a new method which is based on the source's spectral curvature, peak energy, and its detection significance. We also look for spatial extension, which may be a hint for a DM origin according to our N-body simulation studies of the subhalo population. In addition, we used Gaia DR2 data to search for a potential stellar counterpart to our best DM subhalo candidates and, although no firm associations could be found, one of them coincides with the Sagittarius stream. Finally, previous constraints on the DM annihilation cross section are updated with the new number of remaining DM subhalo candidates among unIDs. Our limits now rule out canonical thermal WIMPs up to masses of 10 GeV for b and 20 GeV for τ + τ – annihilation channels, in this way being as sensitive and complementary to those obtained from other targets and probes.

79 ASTRONOMY AND ASTROPHYSICS↗

Design, testing and emplacement of sand-bentonite for the construction of a gas-permeable seal test (gast)

The main aim of a gas-permeable seal is to increase the gas transport capacity of the backfilled underground structures without compromising the radionuclide retention capacity of the engineered barrier system or the host rock. Such a seal, proposed by NAGRA as part of the 'Engineered Gas Transport System' in a L/ILW repository, considers specially designed backfill and sealing materials such as sand/bentonite (S/B) mixtures with a bentonite content of 20- 30%. NAGRA's RD and D plan foresees demonstrating the construction and performance of repository seals and improving the understanding and the database for reliably predicting water and gas transport through these systems. The fluid flow and gas transport properties of these backfills have been determined at the laboratory scale and through modelling the maximum gas pressures in the near field of a repository system and the gas flow rates have been evaluated. Within this context, the Gas-permeable Seal Test (GAST) was constructed at Grimsel Test Site (GTS) to validate the effective functioning of gas-permeable seals at realistic scale. The intrinsic permeability of such seals should be in the order of 10-18 m2. Because the construction of S/B seals is not common practice for construction companies, a stepwise approach was followed to evaluate different construction and quality assurance methods. As a first step, an investigation campaign with simple tests in the laboratory and in the field followed by 1:1 scale pre-tests at GTS was performed. Through this gradual increase of the degree of complexity, practical experience was gained and confidence in the methods and procedures to be used was built, which allowed reliably producing and working with S/B mixtures at a realistic scale. During the whole pre-testing phase, a quality assurance (QA) programme for S/B mixtures was developed and different methods were assessed. They helped to evaluate and choose appropriate emplacement techniques and methodologies to achieve the target S/B dry density of 1.70 g/cm{sup 3}, which results in the desired intrinsic permeability throughout the experiment. The final QA methodology was targeted at engineering measures to decide if the work can proceed, and at producing high resolution material properties database for future water and gas transport modelling activities. The different applied QA techniques included standard core cutter tests, the application of neutron-gamma (Troxler) probes and two mass balance methods (2D and 3D). The methods, looking at different representative scales, have provided only slightly different results and showed that the average density of the emplaced S/B plug was between 1.65 and 1.73 g/cm{sup 3}. Spatial variability of dry densities was observed at decimeter scale. Overall, the pre-testing and QA programme performed for the GAST project demonstrated how the given design criteria and requirements can be met by appropriately planning and designing the material emplacement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feasibility of using computed tomography texture analysis parameters as imaging biomarkers for predicting risk grade of gastrointestinal stromal tumors: comparison with visual inspection

Purpose: To evaluate the feasibility of using computed tomography texture analysis (CTTA) parameters for predicting malignant risk grade and mitosis index of gastrointestinal stromal tumors (GISTs), compared with visual inspection. Method and materials: CTTA was performed on portal phase CT images of 145 surgically confirmed GISTs (mean size: 42.9 ± 37.5 mm), using TexRAD software. Mean, standard deviation, entropy, mean of positive pixels (MPP), skewness, and kurtosis of CTTA parameters, on spatial scaling factor (SSF), 2–6 were compared by risk grade, mitosis rate, and the presence or absence of necrosis on visual inspection. CTTA parameters were correlated with risk grade. Diagnostic performance was evaluated with receiver operating characteristic curve analysis. Enhancement pattern, necrosis, heterogeneity, calcification, growth pattern, and mucosal ulceration were subjectively evaluated by two observers. Results: Three to four parameters at different scales were significantly different according to the risk grade, mitosis rate, and the presence or absence of necrosis (p < 0.041). MPP at fine or medium scale (r = − 0.547 to − 393) and kurtosis at coarse scale (r = 0.424–0.454) correlated significantly with risk grade (p < 0.001). HG-GIST was best differentiated from LG-GIST by MPP at SSF 2 (AUC, 0.782), and kurtosis at SSF 4 (AUC, 0.779) (all p < 0.001). CT features predictive of HG-GIST were density lower than or equal to that of the erector spinae muscles on enhanced images (OR 2.1; p = 0.037; AUC, 0.59), necrosis (OR, 6.1; p < 0.001; AUC, 0.70), heterogeneity (OR, 4.3; p < 0.001; AUC, 0.67), and mucosal ulceration (OR, 3.3; p = 0.002; AUC, 0.62). Conclusion: Using TexRAD, MPP and kurtosis are feasible in predicting risk grade and mitosis index of GISTs. CTTA demonstrated meaningful accuracy in preoperative risk stratification of GISTs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Behavioural phenotypes in mice after prenatal and early postnatal exposure to intermediate frequency magnetic fields

Highlights: • Human exposure to intermediate frequency magnetic fields (MF) is increasing. • We exposed prenatal and early postnatal male mice to 7.5 kHz MFs at 12 and 120 μT. • A behavioural teratology study focused on the developing nervous system. • No consistent adverse effects were observed. Electromagnetic fields are ubiquitous in the environment. Human exposure to intermediate frequency (IF) fields is increasing due to applications like electronic article surveillance systems, wireless power transfer, and induction heating cooking hobs. However, there are limited data on possible health effects of exposure to IF magnetic fields (MF). In the present study, we set out to assess cognitive and behavioural effects of IF MF in mice exposed during prenatal and early postnatal periods. Pregnant female mice were exposed continuously to 7.5 kHz MFs at 12 and 120 μT, from mating until weaning of pups. Sham exposed pregnant mice were used as a control group. A behavioural teratology study was conducted on the male offspring at two months of age to detect possible effects on the developing nervous system. Body weight development did not differ between the exposure groups. The exposure did not alter spontaneous motor activity when exploring a novel cage or anxiety in novelty-suppressed feeding or marble burying tests. Improved performance in the Rotarod task was observed in the 12 µT group, while the 120 μT exposure group swam more slowly than the sham exposed group in the Morris swim navigation task. However, indices of learning and memory (path length and escape latency during task acquisition and search bias during the probe test) did not differ between the exposure groups. Furthermore, the passive avoidance task did not indicate any impairment of long-term memory over a 48 h interval in the exposed groups. In a post-mortem histopathological analysis, there was no evidence for an effect of IF MF exposure on astroglial reactivity or hippocampal neurogenesis. The results suggest that the IF MF used did not have detrimental effects on spatial learning and memory or histological markers of tissue reaction. The two statistically significant findings that were observed (improved performance in the Rotarod task in the 12 µT group and decreased swimming speed in the 120 µT group) are likely to be chance findings, as they do not form an internally consistent, dose-dependent pattern indicative of specific developmental effects.

54 ENVIRONMENTAL SCIENCES↗

Scaling neural simulations in STACS

Abstract As modern neuroscience tools acquire more details about the brain, the need to move towards biological-scale neural simulations continues to grow. However, effective simulations at scale remain a challenge. Beyond just the tooling required to enable parallel execution, there is also the unique structure of the synaptic interconnectivity, which is globally sparse but has relatively high connection density and non-local interactions per neuron. There are also various practicalities to consider in high performance computing applications, such as the need for serializing neural networks to support potentially long-running simulations that require checkpoint-restart. Although acceleration on neuromorphic hardware is also a possibility, development in this space can be difficult as hardware support tends to vary between platforms and software support for larger scale models also tends to be limited. In this paper, we focus our attention on Simulation Tool for Asynchronous Cortical Streams (STACS), a spiking neural network simulator that leverages the Charm++ parallel programming framework, with the goal of supporting biological-scale simulations as well as interoperability between platforms. Central to these goals is the implementation of scalable data structures suitable for efficiently distributing a network across parallel partitions. Here, we discuss a straightforward extension of a parallel data format with a history of use in graph partitioners, which also serves as a portable intermediate representation for different neuromorphic backends. We perform scaling studies on the Summit supercomputer, examining the capabilities of STACS in terms of network build and storage, partitioning, and execution. We highlight how a suitably partitioned, spatially dependent synaptic structure introduces a communication workload well-suited to the multicast communication supported by Charm++. We evaluate the strong and weak scaling behavior for networks on the order of millions of neurons and billions of synapses, and show that STACS achieves competitive levels of parallel efficiency.

59 BASIC BIOLOGICAL SCIENCES↗

ERL R&D: Laser and Laser Light Transport

Operation of the photocathode gun in the ERL requires that a tightly controlled optical pulse train, consisting of temporally and spatially shaped pulses, be delivered at the photocathode in synchrony with the RF field in the gun cavity. The pulse train must also be dynamically variable, in order to tune or ramp up the current in the ERL. A laser was developed especially for this task by Lumera Laser GmbH, of Kaiserslautern Germany, under design supervision and review of the ERL project. Following the final design review, the laser was delivered in August 2009. Preliminary tests certifying its compliance with design specifications have been performed, with further tests planned following the final certification of the ERL laser room in January 2010. The development of the necessary spatial and temporal shaping techniques is an ongoing project: proof of principle experiments have been successfully carried out with a laser of similar pulse width, operating at 532 nm and 81.5 MHz. The next stage is to evaluate the application of these techniques and alternatives, using the operations laser. A transport line has been designed and the propagation of a shaped pulse through it to the photocathode simulated and tested experimentally. As the performance of the complete photocathode drive system is critical for ERL operation, an extensive set of diagnostics will be in place to monitor and maintain its performance. The block diagram in Fig. 1 breaks the optical system down into its basic components, which are discussed.

43 PARTICLE ACCELERATORS↗

Energy Recovery Linac: Laser and Laser Light Transport

Operation of the photocathode gun in the ERL requires that a tightly controlled optical pulse train, consisting of temporally and spatially shaped pulses, be delivered at the photocathode in synchrony with the RF field in the gun cavity. The pulse train must also be dynamically variable, in order to tune or ramp up the current in the ERL. A laser was developed especially for this task by Lumera Laser GmbH, of Kaiserslautern Germany, under design supervision and review of the ERL project. Following the final design review, the laser was delivered in August 2009. Preliminary tests certifying its compliance with design specifications have been performed, with further tests to follow the final certification of the ERL laser room in January 2010. The development of the necessary spatial and temporal shaping techniques is an ongoing project: proof of principle experiments have been successfully carried out with a laser of similar pulse width, operating at 532 nm and 81.5 MHz. The next stage is to evaluate the application of these techniques and alternatives, using the operations laser. A transport line has been designed and the propagation of a shaped pulse through it to the photocathode simulated and tested experimentally. As the performance of the complete photocathode drive system is critical for ERL operation, an extensive set of diagnostics will be in place to monitor and maintain its performance. The block diagram in Fig. 1 breaks the optical system down into its basic components, which are discussed in turn in the following sections.

43 PARTICLE ACCELERATORS↗

Pairing Directional Solar Inputs From Ray Tracing to Solar Receiver/Reactor Heat Transfer Models on Unstructured Meshes: Development and Case Studies

A novel method for pairing surface irradiation and volumetric absorption from Monte Carlo ray tracing to computational heat transfer models is presented. The method is well-suited to directionally and spatially complex concentrated radiative inputs (e.g., solar receivers and reactors). The method employs a generalized algorithm for directly mapping absorbed rays from a Monte Carlo ray tracing model to boundary or volumetric source terms in the computational mesh. The algorithm is compatible with unstructured, two and three-dimensional meshes with varying element shapes. Four case studies were performed on a directly irradiated, windowed solar thermochemical reactor model to validate the method. The method was shown to conserve energy and preserve spatial variation when mapping rays from a Monte Carlo ray tracing model to a computational heat transfer model in ansys fluent.

14 SOLAR ENERGY↗

Increasing FTIR spectromicroscopy speed and resolution through compressive imaging

At the Advanced Light Source at Lawrence Berkeley National Laboratory, we are investigating how to increase both the speed and resolution of synchrotron infrared imaging. Synchrotron infrared beamlines have diffraction-limited spot sizes and high signal to noise, however spectral images must be obtained one point at a time and the spatial resolution is limited by the effects of diffraction. One technique to assist in speeding up spectral image acquisition is described here and uses compressive imaging algorithms. Compressive imaging can potentially attain resolutions higher than allowed by diffraction and/or can acquire spectral images without having to measure every spatial point individually thus increasing the speed of such maps. Here we present and discuss initial tests of compressive imaging techniques performed with ALS Beamline 1.4.3?s Nic-Plan infrared microscope, Beamline 1.4.4 Continuum XL IR microscope, and also with a stand-alone Nicolet Nexus 470 FTIR spectrometer.

47 OTHER INSTRUMENTATION↗

Evaluation of Various Methods for Estimating Global Solar Radiation in the Southeastern United States

Global solar radiation Rg is an important input for crop models to simulate crop responses. Because the scarcity of long and continuous records of Rg is a serious limitation in many countries, Rg is estimated using models. For crop-model application, empirical Rg models that use commonly measured meteorological variables, such as temperature and precipitation, are generally preferred. Although a large number of models of this kind exist, few have been evaluated for conditions in the United States. This study evaluated the performances of 16 empirical, temperature- and/or precipitation-based Rg models for the southeastern United States. By taking into account spatial distribution and data availability, 30 locations in the region were selected and their daily weather data spanning eight years obtained. One-half of the data was used for calibrating the models, and the other half was used for evaluation. For each model, location-specific parameter values were estimated through regressions. Models were evaluated for each location using the root-mean-square error and the modeling efficiency as goodness-of-fit measures. Among the models that use temperature or precipitation as the input variable, the Mavromatis model showed the best performance. The piecewise linear regression based Wu et al. model (WP) performed best not only among the models that use both temperature and precipitation but also among the 16 models evaluated, mainly because it has separate relationships for low and high radiation levels. The modeling efficiency of WP was from ~5% to more than 100% greater than those of the other models, depending on models and locations.

Irradiance, Model evaluation/performance, Agricult↗

Spatiotemporal Modeling of Real World Backsheets Field Survey Data: Hierarchical (Multilevel) Generalized Additive Models: Preprint

Assessing photovoltaic module backsheet durability is critical to increasing module lifetime. Lab based accelerating testing has recently failed to predict large scale failures of widely adopted polymeric materials. Field surveyed data is critical to assess the performance of component lifetime. Using a documented field survey protocol, 13 field surveys where conducted. Each measurement is encoded with it's spatial location in respect to the other modules. By combining field survey data on degradation predictors with real time satellite weather data, data-driven predictive models of backsheet degradation were trained. LOESS models were constructed to investigate the spatial dependence of measurements. It was found that micro-climatic effects like treelines, ground surface changes, and elevation changes effected the magnitude and variance of the measurements. A GAM model was created to predict the value of degradation based on measured predictors. The model includes variables on the climate of the system and the location of each measurement in the PV mounting structure. The model performed well with an adj:R2 of 0:95 for yellowness index prediction. The model was cross-validated using k-folds.

backsheet↗

Automatic detection of large pulmonary solid nodules in thoracic CT images

Purpose: Current computer-aided detection (CAD) systems for pulmonary nodules in computed tomography (CT) scans have a good performance for relatively small nodules, but often fail to detect the much rarer larger nodules, which are more likely to be cancerous. We present a novel CAD system specifically designed to detect solid nodules larger than 10 mm. Methods: The proposed detection pipeline is initiated by a three-dimensional lung segmentation algorithm optimized to include large nodules attached to the pleural wall via morphological processing. An additional preprocessing is used to mask out structures outside the pleural space to ensure that pleural and parenchymal nodules have a similar appearance. Next, nodule candidates are obtained via a multistage process of thresholding and morphological operations, to detect both larger and smaller candidates. After segmenting each candidate, a set of 24 features based on intensity, shape, blobness, and spatial context are computed. A radial basis support vector machine (SVM) classifier was used to classify nodule candidates, and performance was evaluated using ten-fold cross-validation on the full publicly available lung image database consortium database. Results: The proposed CAD system reaches a sensitivity of 98.3% (234/238) and 94.1% (224/238) large nodules at an average of 4.0 and 1.0 false positives/scan, respectively. Conclusions: The authors conclude that the proposed dedicated CAD system for large pulmonary nodules can identify the vast majority of highly suspicious lesions in thoracic CT scans with a small number of false positives.

60 APPLIED LIFE SCIENCES↗

Application of high-order numerical schemes and Newton-Krylov method to two-phase drift-flux model

This study concerns the application and solver robustness of the Newton-Krylov method in solving two-phase flow drift-flux model problems using high-order numerical schemes. In our previous studies, the Newton-Krylov method has been proven as a promising solver for two-phase flow drift-flux model problems. However, these studies were limited to use first-order numerical schemes only. Moreover, the previous approach to treating the drift-flux closure correlations was later revealed to cause deteriorated solver convergence performance, when the mesh was highly refined, and also when higher-order numerical schemes were employed. In this study, a second-order spatial discretization scheme that has been tested with two-fluid two-phase flow model was extended to solve drift-flux model problems. In order to improve solver robustness, and therefore efficiency, a new approach was proposed to treating the mean drift velocity of the gas phase as a primary nonlinear variable to the equation system. With this new approach, significant improvement in solver robustness was achieved. With highly refined mesh, the proposed treatment along with the Newton-Krylov solver were extensively tested with two-phase flow problems that cover a wide range of thermal-hydraulics conditions. Satisfactory convergence performances were observed for all test cases. Numerical verification was then performed in the form of mesh convergence studies, from which expected orders of accuracy were obtained for both the first-order and the second-order spatial discretization schemes. Finally, the drift-flux model, along with numerical methods presented, were validated with three sets of flow boiling experiments that cover different flow channel geometries (round tube, rectangular tube, and rod bundle), and a wide range of test conditions (pressure, mass flux, wall heat flux, inlet subcooling and outlet void fraction).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessing Cloud and Precipitation Properties on Temporal and Spatial Scales Using LASSO Simulations over ENA

Low clouds and precipitation representation remain a major source of uncertainty in Earth System Models (ESMs), particularly due to challenges in representing their sub-grid variability and scale-dependent sampling. This study evaluates the performance of preliminary simulations from the Large-Eddy Simulation (LES) ARM Symbiotic Simulation and Observation (LASSO) project over the Eastern North Atlantic (ENA), with a focus on liquid water path (LWP), ice water path (IWP), cloud fraction (CF), and surface precipitation simulated across closed-cell, open-cell, and transitional cloud regimes. Using LES (100 m horizontal grid spacing) driven by ERA5 and MERRA-2 reanalyses, we assess the representativeness of ground-based point observations by analyzing their correspondence to model-resolved spatial and temporal means. Results suggest that observational sampling of at least 6 hours is required to achieve consistency with domain-scale averages, in particular for observations that exhibit pronounced sub-grid heterogeneity, such as precipitation. ERA5-forced simulations exhibit improved spatial coherence and agreement with domain-averaged quantities when compared to MERRA-2 runs, with performance discrepancies largest for convective cloud conditions due to differences in forcing fidelity and temporal resolution. These findings highlight the importance of regime-aware model evaluation strategies and potentially demonstrate how LES can inform observation-model comparison practices and the development of cloud and precipitation parameterizations in ESMs.

Liang, Jiakun [University of Hawai'i at Manoa] (OR↗

Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy

Purpose: Standard amorphous silicon electronic portal imaging devices (a-Si EPIDs) are x-ray imagers used frequently in radiotherapy that indirectly detect incident x-rays using a metal plate and phosphor screen. These detectors may also be used as two-dimensional dosimeters; however, they have a well-characterized nonwater-equivalent dosimetric response. Plastic scintillating (PS) fibers, on the other hand, have been shown to respond in a water-equivalent manner to x-rays in the energy range typically encountered during radiotherapy. In this study, the authors report on the first experimental measurements taken with a novel prototype PS a-Si EPID developed for the purpose of performing simultaneous imaging and dosimetry in radiotherapy. This prototype employs an array of PS fibers in place of the standard metal plate and phosphor screen. The imaging performance and dosimetric response of the prototype EPID were evaluated experimentally and compared to that of the standard EPID.Methods: Clinical 6 MV photon beams were used to first measure the detector sensitivity, linearity of dose response, and pixel noise characteristics of the prototype and standard EPIDs. Second, the dosimetric response of each EPID was evaluated relative to a reference water-equivalent dosimeter by measuring the off-axis and field size response in a nontransit configuration, along with the off-axis, field size, and transmission response in a transit configuration using solid water blocks. Finally, the imaging performance of the prototype and standard EPIDs was evaluated quantitatively by using an image quality phantom to measure the contrast to noise ratio (CNR) and spatial resolution of images acquired with each detector, and qualitatively by using an anthropomorphic phantom to acquire images representative of human anatomy.Results: The prototype EPID's sensitivity was 0.37 times that of the standard EPID. Both EPIDs exhibited responses that were linear with delivered dose over a range of 1–100 monitor units. Over this range, the prototype and standard EPID central axis responses agreed to within 1.6%. Images taken with the prototype EPID were noisier than those taken with the standard EPID, with fractional uncertainties of 0.2% and 0.05% within the central 1 cm{sup 2}, respectively. For all dosimetry measurements, the prototype EPID exhibited a near water-equivalent response whereas the standard EPID did not. The CNR and spatial resolution of images taken with the standard EPID were greater than those taken with the prototype EPID.Conclusions: A prototype EPID employing an array of PS fibers has been developed and the first experimental measurements are reported. The prototype EPID demonstrated a much morewater-equivalent dose response than the standard EPID. While the imaging performance of the standard EPID was superior to that of the prototype, the prototype EPID has many design characteristics that may be optimized to improve imaging performance. This investigation demonstrates the feasibility of a new detector design for simultaneous imaging and dosimetry treatment verification in radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗