Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Evaluation of Acoustic Channel Capacity for Complex Piping Topology

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through physical barriers, such as the containment building wall. In addition, this approach provides physical cybersecurity since the pipe becomes an analog communication channel which is difficult to eavesdrop on and difficult to sever. In prior work, a laboratory bench-scale system consisting of a six foot-long straight section of nuclear grade stainless steel pipe and high-temperature ultrasonic LiNbO 3 transducers was assembled. The lab systems was used for communication protocol development and preliminary data transmission demonstration. Next phase of project development involves deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dual Selectivity Expressed in [2+2+1] Dynamic Clipping of Unsymmetrical [2]Catenanes

A {pi}-templated dynamic [2+2+1] clipping protocol is established for the synthesis of [2]catenanes from two parts dialdehyde, two parts diamine and one part tetracationic cyclophane. It is further diversified for the selective formation of an unsymmetrical [2]catenane showing great translational selectivity by employing two different dialdehydes in a one-pot reaction. The dual selectivity and the dynamic nature are verified by {sup 1}H NMR spectroscopy, X-ray single crystal structural studies and exchange experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-energy computed tomography-based pulmonary perfusion imaging: Proof-of-principle in a canine model

Purpose: Radiotherapy (RT) that selectively avoids irradiating highly functional lung regions may reduce pulmonary toxicity, which is substantial in lung cancer RT. Single-energy computed tomography (CT) pulmonary perfusion imaging has several advantages (e.g., higher resolution) over other modalities and has great potential for widespread clinical implementation, particularly in RT. The purpose of this study was to establish proof-of-principle for single-energy CT perfusion imaging. Methods: Single-energy CT perfusion imaging is based on the following: (1) acquisition of end-inspiratory breath-hold CT scans before and after intravenous injection of iodinated contrast agents, (2) deformable image registration (DIR) for spatial mapping of those two CT image data sets, and (3) subtraction of the precontrast image data set from the postcontrast image data set, yielding a map of regional Hounsfield unit (HU) enhancement, a surrogate for regional perfusion. In a protocol approved by the institutional animal care and use committee, the authors acquired CT scans in the prone position for a total of 14 anesthetized canines (seven canines with normal lungs and seven canines with diseased lungs). The elastix algorithm was used for DIR. The accuracy of DIR was evaluated based on the target registration error (TRE) of 50 anatomic pulmonary landmarks per subject for 10 randomly selected subjects as well as on singularities (i.e., regions where the displacement vector field is not bijective). Prior to perfusion computation, HUs of the precontrast end-inspiratory image were corrected for variation in the lung inflation level between the precontrast and postcontrast end-inspiratory CT scans, using a model built from two additional precontrast CT scans at end-expiration and midinspiration. The authors also assessed spatial heterogeneity and gravitationally directed gradients of regional perfusion for normal lung subjects and diseased lung subjects using a two-sample two-tailed t-test. Results: The mean TRE (and standard deviation) was 0.6 ± 0.7 mm (smaller than the voxel dimension) for DIR between pre contrast and postcontrast end-inspiratory CT image data sets. No singularities were observed in the displacement vector fields. The mean HU enhancement (and standard deviation) was 37.3 ± 10.5 HU for normal lung subjects and 30.7 ± 13.5 HU for diseased lung subjects. Spatial heterogeneity of regional perfusion was found to be higher for diseased lung subjects than for normal lung subjects, i.e., a mean coefficient of variation of 2.06 vs 1.59 (p = 0.07). The average gravitationally directed gradient was strong and significant (R{sup 2} = 0.99, p < 0.01) for normal lung dogs, whereas it was moderate and nonsignificant (R{sup 2} = 0.61, p = 0.12) for diseased lung dogs. Conclusions: This canine study demonstrated the accuracy of DIR with subvoxel TREs on average, higher spatial heterogeneity of regional perfusion for diseased lung subjects than for normal lung subjects, and a strong gravitationally directed gradient for normal lung subjects, providing proof-of-principle for single-energy CT pulmonary perfusion imaging. Further studies such as comparison with other perfusion imaging modalities will be necessary to validate the physiological significance.

60 APPLIED LIFE SCIENCES↗

Toward a systematic improvement of the fixed-node approximation in diffusion Monte Carlo for solids—A case study in diamond

While Diffusion Monte Carlo (DMC) is in principle an exact stochastic method for ab initio electronic structure calculations, in practice, the fermionic sign problem necessitates the use of the fixed-node approximation and trial wavefunctions with approximate nodes (or zeros). This approximation introduces a variational error in the energy that potentially can be tested and systematically improved. Here, we present a computational method that produces trial wavefunctions with systematically improvable nodes for DMC calculations of periodic solids. These trial wavefunctions are efficiently generated with the configuration interaction using a perturbative selection made iteratively (CIPSI) method. A simple protocol in which both exact and approximate results for finite supercells are used to extrapolate to the thermodynamic limit is introduced. This approach is illustrated in the case of the carbon diamond using Slater–Jastrow trial wavefunctions including up to one million Slater determinants. Fixed-node DMC energies obtained with such large expansions are much improved, and the fixed-node error is found to decrease monotonically and smoothly as a function of the number of determinants in the trial wavefunction, a property opening the way to a better control of this error. The cohesive energy extrapolated to the thermodynamic limit is in close agreement with the estimated experimental value. Interestingly, this is also the case at the single-determinant level, thus, indicating a very good error cancellation in carbon diamond between the bulk and atomic total fixed-node energies when using single-determinant nodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Markovian effects on quantum-communication protocols

We show how, under the influence of non-Markovian environments, two different maximally entangled Bell states give rise to states that have equal classical correlations and the same capacities to violate the Bell-Clauser-Horne-Shimony-Holt inequality, but intriguingly differing usefulness for teleportation and dense coding. We elucidate how different entanglement measures like negativity and concurrence, and two different measures of quantum discord, could account for these behaviors. In particular, we explicitly show how the Ollivier-Zurek measure of discord directly accounts for one state being a better resource for dense coding compared to another. Our study leads to several important issues about these measures of discord.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-G-17A-04: Internal Dosimetric Calculations for Pediatric Nuclear Imaging Applications, Using Monte Carlo Simulations and High-Resolution Pediatric Computational Models

Purpose: Our purpose is to evaluate the administered absorbed dose in pediatric, nuclear imaging studies. Monte Carlo simulations with the incorporation of pediatric computational models can serve as reference for the accurate determination of absorbed dose. The procedure of the calculated dosimetric factors is described, while a dataset of reference doses is created. Methods: Realistic simulations were executed using the GATE toolkit and a series of pediatric computational models, developed by the “IT'IS Foundation”. The series of the phantoms used in our work includes 6 models in the range of 5–14 years old (3 boys and 3 girls). Pre-processing techniques were applied to the images, to incorporate the phantoms in GATE simulations. The resolution of the phantoms was set to 2 mm3. The most important organ densities were simulated according to the GATE “Materials Database”. Several used radiopharmaceuticals in SPECT and PET applications are being tested, following the EANM pediatric dosage protocol. The biodistributions of the several isotopes used as activity maps in the simulations, were derived by the literature. Results: Initial results of absorbed dose per organ (mGy) are presented in a 5 years old girl from the whole body exposure to 99mTc - SestaMIBI, 30 minutes after administration. Heart, kidney, liver, ovary, pancreas and brain are the most critical organs, in which the S-factors are calculated. The statistical uncertainty in the simulation procedure was kept lower than 5%. The Sfactors for each target organ are calculated in Gy/(MBq*sec) with highest dose being absorbed in kidneys and pancreas (9.29*10{sup 10} and 0.15*10{sup 10} respectively). Conclusion: An approach for the accurate dosimetry on pediatric models is presented, creating a reference dosage dataset for several radionuclides in children computational models with the advantages of MC techniques. Our study is ongoing, extending our investigation to other reference models and evaluating the results with clinical estimated doses.

60 APPLIED LIFE SCIENCES↗

Improvement of Prostate Treatment by Anterior Proton Fields

Purpose: We performed a treatment planning study to demonstrate the potential dosimetric benefits of anterior-oriented fields for prostate irradiation by proton beam. A novel in vivo beam range control method shows millimeter accuracy, suggesting that such fields could be safely used to spare the rectum given the sharp distal penumbra of protons. Methods and Materials: Ten prostate patients treated with water-filled endorectal balloon were selected. Bilateral fields were planned following the conventional treatment protocol. Three anterior-oriented fields (0, +30, -30 Degree-Sign ) were planned, with the range compensators manually adjusted to improve rectal sparing. Dose distributions to the clinical target volume, rectum, anterior rectal wall (ARW), bladder, bladder wall (BW), and femoral heads were compared for: A) equally weighted bilateral fields, B) a single straight anterior field, and C) two equally weighted anterior-oblique fields. Results: The anterior-oriented fields required much less beam energy, {approx}10 cm water equivalent path length less than lateral fields. For ARW, the V{sub 95%} for Plans A, B, and C were 39%, 8%, and 6%, respectively; the corresponding V{sub 80%} were 59%, 27%, and 26%, respectively (p = 0.002 when Plan A was compared with B or C). Plan B irradiated a larger volume of BW than did Plan A by 3% at V{sub 95%}, 11% at V{sub 80%}, and 16% at V{sub 50%} (p = 0.002), whereas Plan C differs little from Plan A for BW at these dose levels. The femoral heads received {approx}40% of the prescription dose in Plan A, but negligible dose in Plans B and C. Conclusions: Compared to lateral fields, anterior-oriented fields can significantly reduce dose to the ARW, particularly at high dose levels. These fields alone, or in combination with lateral fields, allow for the possibility of either reducing treatment toxicity at current prescription doses or further dose escalation in the treatment of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Fe 3 O 4 core–TiO 2 shell nanocomposites and nanoconjugates as a foundation for neuroblastoma radiosensitization

Neuroblastoma is the most common extracranial solid malignancy in childhood which, despite the current progress in radiotherapy and chemotherapy protocols, still has a high mortality rate in high risk tumors. Nanomedicine offers exciting and unexploited opportunities to overcome the shortcomings of conventional medicine. The photocatalytic properties of Fe 3 O 4 core-TiO 2 shell nanocomposites and their potential for cell specific targeting suggest that nanoconstructs produced using Fe 3 O 4 core-TiO 2 shell nanocomposites could be used to enhance radiation effects in neuroblastoma. In this study, we evaluated bare, metaiodobenzylguanidine (MIBG) and 3,4-Dihydroxyphenylacetic acid (DOPAC) coated Fe 3 O4@TiO 2 as potential radiosensitizers for neuroblastoma in vitro. The uptake of bare and MIBG coated nanocomposites modestly sensitized neuroblastoma cells to ionizing radiation. Conversely, cells exposed to DOPAC coated nanocomposites exhibited a five-fold enhanced sensitivity to radiation, increased numbers of radiation induced DNA double-strand breaks, and apoptotic cell death. The addition of a peptide mimic of the epidermal growth factor (EGF) to nanoconjugates coated with MIBG altered their intracellular distribution. Cryo X-ray fluorescence microscopy tomography of frozen hydrated cells treated with these nanoconjugates revealed cytoplasmic as well as nuclear distribution of the nanoconstructs. The intracellular distribution pattern of different nanoconjugates used in this study was different for different nanoconjugate surface molecules. Cells exposed to DOPAC covered nanoconjugates showed the smallest nanoconjugate uptake, with the most prominent pattern of large intracellular aggregates. Interestingly, cells treated with this nanoconjugate also showed the most pronounced radiosensitization effect in combination with the external beam x-ray irradiation. Further studies are necessary to evaluate mechanistic basis for this increased radiosensitization effect. Preliminary studies with the nanoparticles carrying an EGF mimicking peptide showed that this approach to targeting could perhaps be combined with a different approach to radiosensitization – use of nanoconjugates in combination with the radioactive iodine. Much additional work will be necessary in order to evaluate possible benefits of targeted nanoconjugates carrying radionuclides.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Chapter 21: Estimating Net Savings - Common Practices. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This chapter focuses on the methods used to estimate net energy savings in evaluation, measurement, and verification (EM and V) studies for energy efficiency (EE) programs. The chapter provides a definition of net savings, which remains an unsettled topic both within the EE evaluation community and across the broader public policy evaluation community, particularly in the context of attribution of savings to a program. The chapter differs from the measure-specific Uniform Methods Project (UMP) chapters in both its approach and work product. Unlike other UMP resources that provide recommended protocols for determining gross energy savings, this chapter describes and compares the current industry practices for determining net energy savings but does not prescribe methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Storage for DC Fast Chargers Development and Demonstration of Operating Protocols for 20-kWh and 200-kWh Field Sites

Many of the currently available and future electric vehicles can be fast charged, and, typically, at least 50% of the battery capacity can be returned in 15 to 20 minutes. This charge rate requires a power of at least 50 kilowatts, which can be expensive in terms of both infrastructure and electric utility demand charges. One potential way of minimizing this cost is to charge the electric vehicle with combined battery and grid power, thereby reducing the peak load on the grid. Many sizes and configurations are possible for such a battery. This study examines two possibilities: (1) a 20-kilowatt hour (kWh) battery energy storage (BES) system and (2) a 200-kWh BES system, as well as developing standard test procedures for assessing the suitability of battery technologies for use in such systems.

25 ENERGY STORAGE↗

Dynamics of a degenerate Fermi gas in a one-dimensional optical lattice coupled to a cavity

We systematically study the dynamics of a one-dimensional degenerate Fermi gas in an optical-lattice potential coupled to a single-mode cavity field. We derive an effective model to study the nonperturbative effect caused by the cavity field. Our numerical results show that due to the addition of the optical-lattice potential, the system undergoes second-order transition to a bistable density-wave steady state, where the atoms form a density wave and the cavity field is bistable. In addition, the coherent oscillating behavior of the cavity photon number can be observed. We also present a feasible experimental protocol to realize these phenomena, which may be beneficial for future quantum-information applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heisenberg spin bus as a robust transmission line for quantum-state transfer

We study quantum-state transfer (QST) through a strongly coupled antiferromagnetic spin chain (acting as a spin bus), between weakly coupled external qubits. By treating the weak coupling as a perturbation, we find that QST is enabled specifically by the second-order terms in the perturbative expansion. We show that QST is robust against disorder in the couplings, either within the bus or to the external qubits. We find that the protocol works when the qubits are attached to any node on an even-size bus or to the antiferromagnetic nodes on an odd-size bus. The optimal time for QST is found to depend nonmonotonically on qubit separation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utilizing a simple CT dosimetry phantom for the comprehension of the operational characteristics of CT AEC systems

Purpose: To investigate the utility of the nested polymethylacrylate (PMMA) phantom (which is available in many CT facilities for CTDI measurements), as a tool for the presentation and comparison of the ways that two different CT automatic exposure control (AEC) systems respond to a phantom when various scan parameters and AEC protocols are modified.Methods: By offsetting the two phantom's components (the head phantom and the body ring) half-way along their longitudinal axis, a phantom with three sections of different x-ray attenuation was created. Scan projection radiographs (SPRs) and helical scans of the three-section phantom were performed on a Toshiba Aquilion 64 and a Philips Brilliance 64 CT scanners, with different scan parameter selections [scan direction, pitch factor, slice thickness, and reconstruction interval (ST/RI), AEC protocol, and tube potential used for the SPRs]. The dose length product (DLP) values of each scan were recorded and the tube current (mA) values of the reconstructed CT images were plotted against the respective Z-axis positions on the phantom. Furthermore, measurements of the noise levels at the center of each phantom section were performed to assess the impact of mA modulation on image quality.Results: The mA modulation patterns of the two CT scanners were very dissimilar. The mA variations were more pronounced for Aquilion 64, where changes in any of the aforementioned scan parameters affected both the mA modulations curves and DLP values. However, the noise levels were affected only by changes in pitch, ST/RI, and AEC protocol selections. For Brilliance 64, changes in pitch affected the mA modulation curves but not the DLP values, whereas only AEC protocol and SPR tube potential selection variations affected both the mA modulation curves and DLP values. The noise levels increased for smaller ST/RI, larger weight category AEC protocol, and larger SPR tube potential selection.Conclusions: The nested PMMA dosimetry phantom can be effectively utilized for the comprehension of CT AEC systems performance and the way that different scan conditions affect the mA modulation patterns, DLP values, and image noise. However, in depth analysis of the reasons why these two systems exhibited such different behaviors in response to the same phantom requires further investigation which is beyond the scope of this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-D-BRA-07: A Phantom Study to Assess the Variability in Radiomics Features Extracted From Cone-Beam CT Images

Purpose: Several studies have demonstrated the prognostic potential for texture features extracted from CT images of non-small cell lung cancer (NSCLC) patients. The purpose of this study was to determine if these features could be extracted with high reproducibility from cone-beam CT (CBCT) images in order for features to be easily tracked throughout a patient’s treatment. Methods: Two materials in a radiomics phantom, designed to approximate NSCLC tumor texture, were used to assess the reproducibility of 26 features. This phantom was imaged on 9 CBCT scanners, including Elekta and Varian machines. Thoracic and head imaging protocols were acquired on each machine. CBCT images from 27 NSCLC patients imaged using the thoracic protocol on Varian machines were obtained for comparison. The variance for each texture measured from these patients was compared to the variance in phantom values for different manufacturer/protocol subsets. Levene’s test was used to identify features which had a significantly smaller variance in the phantom scans versus the patient data. Results: Approximately half of the features (13/26 for material1 and 15/26 for material2) had a significantly smaller variance (p<0.05) between Varian thoracic scans of the phantom compared to patient scans. Many of these same features remained significant for the head scans on Varian (12/26 and 8/26). However, when thoracic scans from Elekta and Varian were combined, only a few features were still significant (4/26 and 5/26). Three features (skewness, coarsely filtered mean and standard deviation) were significant in almost all manufacturer/protocol subsets. Conclusion: Texture features extracted from CBCT images of a radiomics phantom are reproducible and show significantly less variation than the same features measured from patient images when images from the same manufacturer or with similar parameters are used. Reproducibility between CBCT scanners may be high enough to allow the extraction of meaningful texture values for patients. This project was funded in part by the Cancer Prevention Research Institute of Texas (CPRIT). Xenia Fave is a recipient of the American Association of Physicists in Medicine Graduate Fellowship.

60 APPLIED LIFE SCIENCES↗

Marine Algae Industrialization Consortium (MAGIC): Combining biofuel and high-value bioproducts to meet the RFS

The Marine Algae Industrialization Consortium (MAGIC) was formed to address pressing challenges in the commercialization of microalgae as a source of biofuel. The “Marine Algae Industrialization Consortium (MAGIC): Combining biofuel and high-value bioproducts to meet the RFS” project formally addressed two US Department of Energy Bioenergy Technologies Office (BETO) goals: (1) Model the sustainable supply of 1 million metric tonnes ash free dry weight (AFDW) cultivated algal biomass and (2) Demonstrate valuable co-products produced along with biofuel intermediates to increase value of algal biomass by 30%. To achieve these goals, the project demonstrated and validated high-value co-products to drive down the cost of biofuel by increasing the value of algae “co-products” towards increasing the selling price of total algae biomass as one of the key drivers of economics and adoption. This was accomplished through five core, interdependent tasks including: (1) strain selection to identify and deliver strains for mass culture, (2) mass culture using a hybrid cultivation system and following key operating parameters for downstream applications to provide algae feedstock, (3) recovery and conversion to evaluate two alternative methods to separate dry algae biomass into oil and residuals for downstream testing, (4) product assessment to determine biofuel, aquafeed or poultry feed product efficacy using algae biomass fractions as well as to provide critical performance data for valuation and (5) commercialization to use technoeconomic and life cycle assessments (TEA/LCA) as iterative design and assessment tools including consideration of target markets, competitors, and distribution channels to guide product assessment, development and valuation. A total of 46 peer-review publications, many open-access, provide detail of much of the work carried out and the results of the tasks. Additional reports and presentations provide other technical and public engagement material. At a high level, using a variety of approaches, more than 1000 marine microalgae strains were evaluated to ultimately identify the seven winners that were down-selected to be grown in mass culture. Strain selection demonstrated that there were no ‘super strains’ and that each candidate had strengths and limitations for specific products, growth conditions or operational considerations. Mass culture growth of these seven strains at >5000 L / 29 m 2 scale found that four them were suitable for product assessment. More than 250 kg of biomass was produced across hundreds of pond runs along with thousands of cultivation entries on the growth and biomass characteristics as well as environmental parameters. In the process, dozens of standard operating procedures were generated as was custom software to process and analyze cultivation data. Recovery and conversion of algae biomass demonstrated that a hexane solvent based extraction protocol was most effective at recovering oil (biocrude) from algae and four strains were processed to produce oil and lipid extracted algae (residuals) for downstream testing. Membrane-based oil separation was less successful, but may still be applicable to other commercial applications in the future. Product testing demonstrated that algae biocrude is of high quality and hydrotreating generated numerous fractions of high quality composition for fuel and lubricate based applications. Aquafeed studies performed at a variety of scales showed that both whole and defatted (lipid extracted algae) microalgae were suitable as a feed ingredient, but that the specifics of the fed animal and biochemical composition of the algae are critical factors when determining formulation. Similarly, poultry studies on whole and defatted microalgae generally showed positive outcomes on animal growth and health, with some microalgae providing enhanced nutritional composition of the animal product. Economic and life cycle assessments covered a wide range of possible commercialization and sustainability scenarios. Replacement value, improved product value added, consumer values marketing added valuation and improved animal health were considered as alternatives for microalgae valuation. Using the open pond system, algae productivity was identified as the key driver of commercialization economics, but combination of co-products (e.g. animal feed) with biofuel production substantially increased the total selling price of algae. Modeled microalgae selling price exceeded $\$$1500/tonne and could generate competitive biofuel selling prices below $\$$5 gallon gas equivalents using realistic algal productivities. Short (process scale) and longer (decadal trends) sustainability assessments show that marine microalgae can enhance the sustainability of energy production and lead to other realized benefits in water, fertilizer and land use for other sectors (e.g. agriculture). This project successfully demonstrated all of the components of an end-to-end process from mass microalgae cultivation and dewatering, to recovery and conversion of algae biomass components, to final product demonstration and process valuation; the combined results provide a framework for future commercialization of algae based biofuels.

09 BIOMASS FUELS↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational characterization and experimental validation of the thermal neutron source for neutron capture therapy research at the University of Missouri

Parameter studies, design calculations and neutronic performance measurements have been completed for a new thermal neutron beamline constructed for neutron capture therapy cell and small-animal radiobiology studies at the University of Missouri Research Reactor. The beamline features the use of single-crystal silicon and bismuth sections for neutron filtering and for reduction of incident gamma radiation. The computational models used for the final beam design and performance evaluation are based on coupled discrete-ordinates and Monte Carlo techniques that permit detailed modeling of the neutron transmission properties of the filtering crystals with very few approximations. Validation protocols based on neutron activation spectrometry measurements and rigorous least-square adjustment techniques show that the beam produces a neutron spectrum that has the anticipated level of thermal neutron flux and a somewhat higher than expected, but radio-biologically insignificant, epithermal neutron flux component. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Computational Studies of Gas Phase Reactions of Zirconium Tetrachloride (ZrCl{sub 4}) and Metal Chloride Impurities

Zirconium-based cladding materials that surround used nuclear fuel (UNF) rods represent a significant fraction of the total amount of high level waste that must be disposed of in long term geological repositories. The decontamination, recovery and reuse of these materials would significantly reduce the high level waste associated with light water reactors and could provide a new source of hafnium free zirconium for the fabrication of new nuclear components. One part in the strategy to recycle zirconium from used cladding materials involves developing a computational modeling (DFT) protocol to understand the reactions between ZrCl{sub 4} and metal chloride impurities that may occur in the gas phase during sublimation. Several of the metal chloride species present are known to form Lewis acid/base adducts in the gas phase and development of purification protocols require investigation into the properties of these ZrCl{sub 4} contaminates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗