Development of a detachable high speed miniature scanning probe microscope for large area substrates inspection

We have developed a high speed, miniature scanning probe microscope (MSPM) integrated with a Positioning Unit (PU) for accurately positioning the MSPM on a large substrate. This combination enables simultaneous, parallel operation of many units on a large sample for high throughput measurements. The size of the MSPM is 19 × 45 × 70 mm{sup 3}. It contains a one-dimensional flexure stage with counter-balanced actuation for vertical scanning with a bandwidth of 50 kHz and a z-travel range of more than 2 μm. This stage is mechanically decoupled from the rest of the MSPM by suspending it on specific dynamically determined points. The motion of the probe, which is mounted on top of the flexure stage is measured by a very compact optical beam deflection (OBD). Thermal noise spectrum measurements of short cantilevers show a bandwidth of 2 MHz and a noise of less than 15 fm/Hz{sup 1/2}. A fast approach and engagement of the probe to the substrate surface have been achieved by integrating a small stepper actuator and direct monitoring of the cantilever response to the approaching surface. The PU has the same width as the MSPM, 45 mm and can position the MSPM to a pre-chosen position within an area of 275×30 mm{sup 2} to within 100 nm accuracy within a few seconds. During scanning, the MSPM is detached from the PU which is essential to eliminate mechanical vibration and drift from the relatively low-resonance frequency and low-stiffness structure of the PU. Although the specific implementation of the MSPM we describe here has been developed as an atomic force microscope, the general architecture is applicable to any form of SPM. This high speed MSPM is now being used in a parallel SPM architecture for inspection and metrology of large samples such as semiconductor wafers and masks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Colloquium : Measuring the neutron star equation of state using x-ray timing

One of the primary science goals of the next generation of hard x-ray timing instruments is to determine the equation of state of matter at supranuclear densities inside neutron stars by measuring the radius of neutron stars with different masses to accuracies of a few percent. Three main techniques can be used to achieve this goal. The first involves waveform modeling. The flux observed from a hotspot on the neutron star surface offset from the rotational pole will be modulated by the star s rotation, and this periodic modulation at the spin frequency is called a pulsation. As the photons propagate through the curved spacetime of the star, information about mass and radius is encoded into the shape of the waveform (pulse profile) via special and general-relativistic effects. Using pulsations from known sources (which have hotspots that develop either during thermo- nuclear bursts or due to channeled accretion) it is possible to obtain tight constraints on mass and radius. The second technique involves characterizing the spin distribution of accreting neutron stars. A large collecting area enables highly sensitive searches for weak or intermittent pulsations (which yield spin) from the many accreting neutron stars whose spin rates are not yet known. The most rapidly rotating stars provide a clean constraint, since the limiting spin rate where the equatorial surface velocity is comparable to the local orbital velocity, at which mass shedding occurs, is a function of mass and radius. However, the overall spin distribution also provides a guide to the torque mechanisms in operation and the moment of inertia, both of which can depend sensitively on dense matter physics. The third technique is to search for quasiperiodic oscillations in x-ray flux associated with global seismic vibrations of magnetars (the most highly magnetized neutron stars), triggered by magnetic explosions. The vibrational frequencies depend on stellar parameters including the dense matter equation of state, and large-area x-ray timing instruments would provide much improved detection capability. In addition, an illustration is given of how these complementary x-ray timing techniques can be used to constrain the dense matter equation of state and the results that might be expected from a 10 m 2 instrument are discussed. Also discussed are how the results from such a facility would compare to other astronomical investigations of neutron star properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma-accelerated flyer-plates for equation of state studies

We report on a new technique to accelerate flyer-plates to high velocities ({approx}5 km/s). In this work, a strong shock is created through direct laser ablation of a thin polyimide foil. Subsequent shock breakout of that foil results in the generation of a plasma characterized by a smoothly increasing density gradient and a strong forward momentum. Stagnation of this plasma onto an aluminum foil and the resultant momentum transfer accelerates a thin aluminum flyer-plate. The aluminum flyer-plate is then accelerated to a peak velocity of {approx}5 km/s before impact with a transparent lithium fluoride (LiF) window. Simulations of the stagnating plasma ramp compression and wave reverberations within the flyer-plate suggest that the temperature at the flyer-plate impact surface is elevated by less than 50 Degree-Sign C. Optical velocimetry is used to measure the flyer-plate velocity and impact conditions enabling the shocked refractive index of LiF to be determined. The results presented here are in agreement with conventional flyer-plate measurements validating the use of plasma-accelerated flyer-plates for equation of state and impact studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and verification of a novel hollow vibrating module for laser machining

If a vibration module is added on laser machining system, the quality of surface finish and aspect ratio on metals can be significantly enhanced. In this study, a single mobility model of vibrating laser along the path of laser beam was put forward. In order to realize the desired unidirectional motion, a resonance type vibration module with optical lens was designed and manufactured. This cylindrical module was composed of curved-beam flexure elements. The cylindrical coordinate system was established to describe the relationship of a curved-beam flexure element’s motion and deformation. In addition, the stiffness matrix of the curved-beam element was obtained. Finite element method and dynamical modeling were provided to analyze the resonance frequency and the displacement of the motion. The feasibility of the design was demonstrated with the help of experiments on frequency response. Experimental results show good agreement with theoretical analysis and simulation predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nature of size effects in compact models of field effect transistors

Investigations have shown that in the local approximation (for sizes L < 100 μm), AlGaN/GaN high electron mobility transistor (HEMT) structures satisfy to all properties of chaotic systems and can be described in the language of fractal geometry of fractional dimensions. For such objects, values of their electrophysical characteristics depend on the linear sizes of the examined regions, which explain the presence of the so-called size effects—dependences of the electrophysical and instrumental characteristics on the linear sizes of the active elements of semiconductor devices. In the present work, a relationship has been established for the linear model parameters of the equivalent circuit elements of internal transistors with fractal geometry of the heteroepitaxial structure manifested through a dependence of its relative electrophysical characteristics on the linear sizes of the examined surface areas. For the HEMTs, this implies dependences of their relative static (A/mm, mA/V/mm, Ω/mm, etc.) and microwave characteristics (W/mm) on the width d of the sink-source channel and on the number of sections n that leads to a nonlinear dependence of the retrieved parameter values of equivalent circuit elements of linear internal transistor models on n and d. Thus, it has been demonstrated that the size effects in semiconductors determined by the fractal geometry must be taken into account when investigating the properties of semiconductor objects on the levels less than the local approximation limit and designing and manufacturing field effect transistors. In general, the suggested approach allows a complex of problems to be solved on designing, optimizing, and retrieving the parameters of equivalent circuits of linear and nonlinear models of not only field effect transistors but also any arbitrary semiconductor devices with nonlinear instrumental characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray microfocusing with off-axis ellipsoidal mirror

High-precision ellipsoidal mirrors for two-dimensionally focusing X-rays to nanometer sizes have not been realized because of technical problems in their fabrication processes. The objective of the present study is to develop fabrication techniques for ellipsoidal focusing mirrors in the hard-X-ray region. We design an off-axis ellipsoidal mirror for use under total reflection conditions up to the X-ray energy of 8 keV. We fabricate an ellipsoidal mirror with a surface roughness of 0.3 nm RMS (root-mean-square) and a surface figure error height of 3.0 nm RMS by utilizing a surface profiler and surface finishing method developed by us. The focusing properties of the mirror are evaluated at the BL29XUL beamline in SPring-8. A focusing beam size of 270 nm × 360 nm FWHM (full width at half maximum) at an X-ray energy of 7 keV is observed with the use of the knife-edge scanning method. We expect to apply the developed fabrication techniques to construct ellipsoidal nanofocusing mirrors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A microwave resonator for limiting depth sensitivity for electron paramagnetic resonance spectroscopy of surfaces

A microwave Surface Resonator Array (SRA) structure is described for use in Electron Paramagnetic Resonance (EPR) spectroscopy. The SRA has a series of anti-parallel transmission line modes that provides a region of sensitivity equal to the cross-sectional area times its depth sensitivity, which is approximately half the distance between the transmission line centers. It is shown that the quarter-wave twin-lead transmission line can be a useful element for design of microwave resonators at frequencies as high as 10 GHz. The SRA geometry is presented as a novel resonator for use in surface spectroscopy where the region of interest is either surrounded by lossy material, or the spectroscopist wishes to minimize signal from surrounding materials. One such application is in vivo spectroscopy of human finger-nails at X-band (9.5 GHz) to measure ionizing radiation dosages. In order to reduce losses associated with tissues beneath the nail that yield no EPR signal, the SRA structure is designed to limit depth sensitivity to the thickness of the fingernail. Another application, due to the resonator geometry and limited depth penetration, is surface spectroscopy in coating or material science. To test this application, a spectrum of 1.44 μM of Mg{sup 2+} doped polystyrene 1.1 mm thick on an aluminum surface is obtained. Modeling, design, and simulations were performed using Wolfram Mathematica (Champaign, IL; v. 9.0) and Ansys High Frequency Structure Simulator (HFSS; Canonsburg, PA; v. 15.0). A micro-strip coupling circuit is designed to suppress unwanted modes and provide a balanced impedance transformation to a 50 Ω coaxial input. Agreement between simulated and experimental results is shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact steady-state and high-flux Falcon ion source for tests of plasma-facing materials

This paper describes the design and operation of the Falcon ion source. It is based on conventional design of anode layer thrusters. This ion source is a versatile, compact, affordable, and highly functional in the research field of the fusion materials. The reversed magnetic field configuration of the source allows precise focusing of the ion beam into small spot of Almost-Equal-To 3 mm and also provides the limited capabilities for impurity mass-separation. As the result, the source generates steady-state ion beam, which irradiates surface with high heat (0.3 - 21 MW m{sup -2}) and particle fluxes (4 Multiplication-Sign 10{sup 21}- 3 Multiplication-Sign 10{sup 23} m{sup -2}s{sup -1}), which approaches the upper limit for the flux range expected in ITER.

43 PARTICLE ACCELERATORS↗

Super-thin single crystal diamond membrane radiation detectors

We propose to use the non-electronic grade (nitrogen content 5 ppb < [N] < 5 ppm) single crystal (sc) chemical vapour deposited (CVD) diamond as a thin-membrane radiation detector. Using deep Ar/O{sub 2} plasma etching it is possible to produce self-supported few micrometres thick scCVD membranes of a size approaching 7 mm × 7 mm, with a very good surface quality. After metallization and contacting, electrical properties of diamond membrane detectors were probed with 5.486 MeV α-particles as an ionization source. Despite nitrogen impurity, scCVD membrane detectors exhibit stable operation, charge collection efficiency close to 100%, with homogenous response, and extraordinary dielectric strength up to 30 V/μm.

36 MATERIALS SCIENCE↗

Applications of SPM to Studies of Mineral–Water Interface Chemistry

The scanning probe microscope (SPM) has been utilized in studies of solid surfaces for nearly four decades. With resolution as high as the single atom level, valuable information on the structure and other properties of solid surfaces can be obtained. One of the most exciting areas of application for the SPM is in the study of mineral–water interfaces where the chemical reactions taking place are both of fundamental interest as well as important from an environmental/geochemical perspective. In this article, the basic design of one type of SPM, the atomic force microscope (AFM), is introduced followed by an examination of the different levels of resolution that may be exploited to obtain fundamental information on kink, step, and surface microtopography from mineral surfaces immersed in reactive solutions. The examples of these particular applications highlight the influence of solution chemistry on the rates and mechanisms of mineral growth and dissolution reactions that are readily followed with in-situ AFM instrumentation.

Higgins, Steven↗

Can We Better Constrain the Timing of GNAIW/UNADW Variability in the Western Equatorial Atlantic and Its Relationship to Climate Change During the Last Deglaciation?

We have revisited the well-trod VM28-122 core retrieved from the deep Colombian Basin, which includes sediments that reflect modern Upper North Atlantic Deep Water and extends through the last deglaciation into the last glacial period when the site was bathed in Glacial North Atlantic Intermediate Water. Here, we leverage the nearby Cariaco Basin's surface water radiocarbon reconstruction (reservoir age, and ΔR) on the IntCal20 timescale to recast the period of the last deglaciation with a newly constrained age model. Based on the revised age model, we observe that the multimillennial decrease in benthic δ 13 C and B/Ca (which record δ 13 C of dissolved inorganic carbon and Δ[CO 3 –2 ], respectively) began at 18,100 ± 240 (95% CI) calibrated years BP, synchronous with Termination 1, as identified by changes in the Antarctic Ice Sheet composite and by the onset of rapid glacier recession in the Southern Hemisphere (Denton et al., 2010, https://doi.org/10.1126/science.1184119; Denton et al., 2021, https://10.1016/j.quascirev.2020.106771). The beginning of the decrease in benthic δ 18 O is concurrent with the changes in carbon chemistry or at most, a few hundred years later. It is no later than 17,700 ± 300 (95% CI) yrs BP in our record, at the putative start of Heinrich Stadial 1. With sufficient data density (more than 2–3 control points per kyr) and an independent record of past surface water radiocarbon variations, it is possible to achieve late glacial and deglacial chronologies with fidelities similar to those of ice cores. Furthermore, doing so in more oceanographic locations should shed light more broadly on the mechanisms instrumental to abrupt climate change.

58 GEOSCIENCES↗

El Niño increases the risk of lower Mississippi River flooding

Mississippi River floods rank among the costliest climate-related disasters in the world. Improving flood predictability, preparedness, and response at seasonal to decadal time-scales requires an understanding of the climatic controls that govern flood occurrence. Linking flood occurrence to persistent modes of climate variability like the El Niño-Southern Oscillation (ENSO) has proven challenging, due in part to the limited number of high-magnitude floods available for study in the instrumental record. To augment the relatively short instrumental record, we use output from the Community Earth System Model (CESM) Last Millennium Ensemble (LME) to investigate the dynamical controls on discharge extremes of the lower Mississippi River. We show that through its regional influence on surface water storage, the warm phase of ENSO preconditions the lower Mississippi River to be vulnerable to flooding. In the 6–12 months preceding a flood, El Niño generates a positive precipitation anomaly over the lower Mississippi basin that gradually builds up soil moisture and reduces the basin’s infiltration capacity, thereby elevating the risk of a major flood during subsequent rainstorms. Our study demonstrates how natural climate variability mediates the formation of extreme floods on one of the world’s principal commercial waterways, adding significant predictive ability to near- and long-term forecasts of flood risk.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Characterization Techniques for Iron Pipe Corrosion Products and Iron Oxide Thin Films

A common problem faced by drinking water studies is that of properly characterizing the corrosion products (CP) in iron pipescor synthetic Fe (hydr)oxides used to simulate the iron pipe used in municipal drinking-water systems. The present work compares the relative applicability of a suite of imaging and analytical techniques for the characterization of CPs and synthetic Fe oxide thin films and provide an overview of the type of data that each instrument can provide as well as their limitations to help researchers and consultants choose the best technique for a given task. Crushed CP from a water distribution system and synthetic Fe oxide thin films formed on glass surfaces were chosen as test samples for this evaluation. The CP and synthetic Fe oxide thin films were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive spectroscopy, time-of-flight secondary ion mass spectrometry (ToF-SIMS), X-ray powder diffractometry (XRD), grazing incident diffractometry (GID), transmission electron microscopy (TEM), selected area electron diffraction, X-ray photoelectron spectroscopy (XPS), Fourier transform infrared, Mössbauer spectroscopy, Brunauer-Emmett-Teller N2 adsorption and Fe concentration was determined by the ferrozine method. XRD and GID were found to be the most suitable techniques for identification of the mineralogical composition of CP and synthetic Fe oxide thin films, respectively. AFM and a combined ToF-SIMS-AFM approach proved excellent for roughness and depth profiling analysis of synthetic Fe oxide thin films, respectively. Corrosion products were difficult to study by AFM due to their surface roughness, while synthetic Fe oxide thin films resisted most spectroscopic methods due to their limited thickness (118 nm). XPS analysis is not recommended for mixtures of Fe (hydr)oxides due to their spectral similarities. SEM and TEM provided great detail on mineralogical morphology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MODULES FOR EXPERIMENTS IN STELLAR ASTROPHYSICS (MESA): BINARIES, PULSATIONS, AND EXPLOSIONS

We substantially update the capabilities of the open-source software instrument Modules for Experiments in Stellar Astrophysics (MESA). MESA can now simultaneously evolve an interacting pair of differentially rotating stars undergoing transfer and loss of mass and angular momentum, greatly enhancing the prior ability to model binary evolution. New MESA capabilities in fully coupled calculation of nuclear networks with hundreds of isotopes now allow MESA to accurately simulate the advanced burning stages needed to construct supernova progenitor models. Implicit hydrodynamics with shocks can now be treated with MESA, enabling modeling of the entire massive star lifecycle, from pre-main-sequence evolution to the onset of core collapse and nucleosynthesis from the resulting explosion. Coupling of the GYRE non-adiabatic pulsation instrument with MESA allows for new explorations of the instability strips for massive stars while also accelerating the astrophysical use of asteroseismology data. We improve the treatment of mass accretion, giving more accurate and robust near-surface profiles. A new MESA capability to calculate weak reaction rates “on-the-fly” from input nuclear data allows better simulation of accretion induced collapse of massive white dwarfs and the fate of some massive stars. We discuss the ongoing challenge of chemical diffusion in the strongly coupled plasma regime, and exhibit improvements in MESA that now allow for the simulation of radiative levitation of heavy elements in hot stars. We close by noting that the MESA software infrastructure provides bit-for-bit consistency for all results across all the supported platforms, a profound enabling capability for accelerating MESA's development.

79 ASTRONOMY AND ASTROPHYSICS↗

Stability and normal zone propagation in YBCO CORC cables

In this study, a two layer conductor on round core cable was tested for stability and normal zone propagation at 77 K in a liquid nitrogen bath. The cable was instrumented with voltage taps and wires on each strand over the cable’s central portion (i.e. excluding the end connections of the cable with the outside world). A heater was placed in the central zone on the surface of the cable, which allowed pulses of various powers and durations to be generated. Shrinking (recovering) and expanding (not recovering) normal zones have been detected, as well as stationary zones which were in thermal equilibrium. Such stationary thermal equilibrium zones did not expand or contract, and hit a constant upper temperature while the heater current persisted; they are essentially a form of Stekly stability. Overall, the cable showed a high degree of stability. Notably, it was able to carry a current of 0.45I c cable with maximum temperature of 123 K for one minute without damage.

36 MATERIALS SCIENCE↗

NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset

Lawrence Berkeley National Laboratory (LBNL) contracted the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) to observe watersheds of interest near Crested Butte, CO with remotely sensed data including imaging spectroscopy. The flight box design encompassed the watersheds, and flight design targeted a minimum of 30% overlap between adjacent flight lines. The total area surveyed was 334 km2 across 72 lines. Flight lines were oriented north-south for consistency in solar illumination geometry. Seven days were required to cover the flight area. Some areas were flown additional times to improve data quality or temporal coincidence between airborne acquisitions and field sampling. In total, 102 lines were collected and can be downloaded here: https://portal.nersc.gov/wfsfa/doi-10-15485-1617204/. The instrument used for the acquisition was an Airborne Visible-Infrared Imaging Spectrometer - Next Generation (AVIRIS-NG), which records radiance within 426 contiguous spectral bands in the wavelength range from 380 to 2510 nm. The instrument was flown at a target aboveground altitude of 1000 m for a processed data spatial resolution of 1 m. These data are non-orthorectified, radiance data that require further processing prior to use as a surface reflectance data set.

2018 NEON and 2025 CHESS Campaigns↗

Detection of a Space Capsule Entering Earth’s Atmosphere with Distributed Acoustic Sensing (DAS)

On 24 September 2023, the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer sample return capsule (SRC) entered Earth’s atmosphere after successfully collecting samples from an asteroid. The known trajectory and timing of this return provided a rare opportunity to strategically instrument sites to record geophysical signals produced by the capsule because it travelled at hypersonic speeds through the atmosphere. For this work, we deployed two distributed acoustic sensing (DAS) interrogators to sample over 12 km of surface-draped fiber-optic cables, as well as six collocated seismometer-infrasound sensor pairs, spread across two sites near Eureka, Nevada. This campaign-style rapid deployment is the first reported recording of an SRC re-entry with any distributed fiber-optic sensing technology. The DAS interrogators recorded an impulsive arrival with an extended coda which had features that were similar to recordings from both the seismometers and infrasound sensors. While the signal-to-noise ratio of the DAS data was lower than the seismic-infrasound data, the extremely dense spacing of fiber-optic sensors allowed for more phases to be clearly distinguished and the visualization of the continuous transformation of the wavefront as it impacted the ground. Unexpectedly, the DAS recordings contain less low-frequency content than is present in both the seismic and infrasound data. The deployment conditions strongly affected the recorded DAS data; in particular, we observed that fiber selection and placement exert strong controls on data quality.

58 GEOSCIENCES↗

Selective stress-based microcantilever sensors for enhanced surveillance

Assessment of component aging and degradation in weapon systems remains a considerable challenge for the Integrated Stockpile Evaluation program. Analysis of weapon atmospheres can provide degradation signatures and indicate the presence of corrosive vapors. However, a critical need exists for compatible in-situ sensors to detect moisture and other gases over stockpile lifetimes. This inhibits development of both “self-aware weapons” and fully instrumented weapon test platforms that could provide in-situ data to validate high-fidelity models for gases within weapons. We developed platforms for on-demand weapon atmosphere surveillance based on static microcantilevers (SMC) and surface accoustic wave (SAW) devices coated with nanoporous metal organic frameworks (MOFs) to provide selectivity.