Search NASA⌕ Search

SEARCH · Search NASA

Results for “15 - GEOTHERMAL ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Search for gamma rays of energy 10(15) eV from Cygnus X-3

Finite flux of excess radiation of energy 10 to the 15th power has been reported by two groups from the direction of Cygnus X-3, with the characteristic periodicity of 4.8 hrs. Samorski and Stamm find that the muon content of the showers generated by this excess radiation is about 77% of that in normal cosmic ray showers, whereas the expectation for gamma ray showers is less than 10%. It is thus difficult to understand the nature of the radiation arriving from the direction of Cygnus X-3. Samorski and Stamm measured the muon densities close to the core (approx. 10 m), where contamination due to other components is severe. Even though this does not explain the high ratio of muon densities, measurements should be carried out away from the core to establish the nature of the radiation. In order to establish the signal from Cygnus X-3 and its muon content with better statistical significance, an extensive air shower array, specifically designed for this purpose was operated at Kolar Gold Fields (longitude: 78 deg .3 E; latitude: + 12 deg .95; atmospheric depth: 920 q/square centimeters) since September, 1984. The details of the array and the accuracy of arrival direction measurements are discussed.

Bhat, P. N.↗

Composition of primary cosmic rays at energies 10(15) to approximately 10(16) eV

The sigma epsilon gamma spectrum in 1 approx. 5 x 1000 TV observed at Mt. Fuji suggests that the flux of primary protons 10 to the 15 approx 10th eV is lower by a factor of 2 approx. 3 than a simple extrapolation from lower energies; the integral proton spectrum tends to be steeper than around to the power V and the spectral index tends to be steeper than Epsilon to the -17th power around 10 to the 14th power eV and the spectral index becomes approx. 2.0 around 10 to the 15th power eV. If the total flux of primary particles has no steepening up to approx 10 to the 15th power eV, than the fraction of primary protons to the total flux should be approx 20% in contrast to approx 45% at lower energies.

Amenomori, M.↗

The longitudinal development of muons in cosmic ray air showers at energies 10(15) - 10(17) eV

The relationship between longitudinal development of muons and conventional equi-intensity cuts is carefully investigated. The development of muons in Extensive Air Showers (EAS) has been calculated using simulation with a scaling violation model at the highest energies and mixed primary composition. Profiles of equi-intensity cuts expected at observation altitudes of 550, 690 and 930/sq cm can fit the observed data very well.

Source record↗

Anisotropy of cosmic rays of energy 10 (15) eV to 10 (17) eV observed at Akeno

Anisotropy of cosmic rays is studied with extensive air showers (EAS) data by muon trigger. The present results support those obtained by electron trigger which suggest the significant anisotropy of second harmonics with phase around 100 deg in right ascension for showers of 10 to the 16th power - 10 to the 17th power eV, and predominant arrival direction of 230 deg in right ascension for muon-rich showers. It seems that the phase of the first harmonics in the energy range below 10 to the 11th power eV is about 300 deg in right ascension and the second harmonics near 6 x 10 to the 14th power eV is statistically significant with an amplitude of 0.39 + or - 0.13% in direction of 83 + or - 10 deg in right ascension.

Kifune, T.↗

RACEE: Community of Klawock Competition Project Summary

RACEE is a US Department of Energy (DOE) competition that challenged rural Alaskan communities to commit to saving 15% energy by 2020 (baseline 2010) which aligns with the State’s Energy Efficiency goal. In January 2016, 64 communities, including eight Southeast communities, submitted pledges to become energy champions and move to the next phase of the competition. In April, DOE announced that 13 communities would be eligible to apply for up to $3.4 million in funding to implement the community energy efficiency plans they develop in Phase II of the competition. Klawock is one of those 13 communities and the only eligible community in Southeast Alaska.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Toward Energy-Efficient HPC: Insights from Power Profiling a Cloud-Resolving Earth System Model

Power is a fundamental constraint as supercomputing advances to exascale. Efficient operation within strict power budgets requires application-aware power management based on a detailed understanding of application-level power behavior. This work analyzes the Energy Exascale Earth System Model (E3SM) atmosphere component, SCREAM, on Perlmutter (NERSC) and Frontier (OLCF). We characterize power variation across inputs, concurrency levels, and power caps, evaluate the energy impact of code optimizations, and attribute energy within the code using a newly developed GPU energy model. Results show that SCREAM’s peak power remains stable during its core execution phase and decreases gradually as concurrency increases. Power capping experiments reveal a performance–energy "sweet spot". On Perlmutter, limiting GPU power to 50% of thermal design power (TDP) achieves up to 15% energy savings with a 7% performance penalty. On Frontier, a 40% TDP cap yields up to 10% energy savings with less than 10% performance loss. Code optimizations reduce SCREAM energy by shortening run time without increasing power. Modeling reveals a critical insight: data movement accounts for approximately 70% of SCREAM’s GPU energy. This fundamentally shifts the optimization focus from FLOPS to data transfer reduction for this class of applications, offering the most impactful strategy for improving energy efficiency. This work establishes a foundation for practical, application-aware power management at exascale.

Zhao, Zhengji [Lawrence Berkeley National Laborato↗

Atomic Data and Spectral Line Intensities for CA XVII

Electron impact collision strengths, energy levels, oscillator strengths and spontaneous radiative decay rates are calculated for Ca XVII. The configurations used are 2s(sup 2), 2s2p, 2p(sup 2), 2l3l', 214l' and 2s5l', with l = s,p and l' = s,p, d giving rise to 92 fine-structure levels in intermediate coupling. Collision strengths are calculated at seven incident energies (15, 30, 75, 112.5, 150, 187.5 and 225 Ry) for the transitions within the three lowest configurations corresponding to the 10 lowest energy levels, and five incident energies (75, 112.5, 150, 187.5 and 225 Ry) for transitions between the lowest five levels and the n = 3,4,5 configurations. Calculations have been carried out using the distorted wave approximation. Excitation rate coefficients are calculated as a function of electron temperature by assuming a Maxwellian electron velocity distribution. Using the excitation rate coefficients and the radiative transition rates of the present work, and R-Matrix results for the 2s2, 2s2p, 2p2 configurations available in the literature, statistical equilibrium equations for level populations are solved at electron densities covering the range of 10(exp 8)-10(exp 14)/cu cm at an electron temperature of log Te(K)=6.7, corresponding to the maximum abundance of Ca XVII. Spectral line intensities are calculated, and their diagnostic relevance L; discussed. This dataset will be made available in the next version of the CHIANTI database.

Bhatia, A.K.↗

Retro-Commissioning Sensor Suitcase for Energy Efficiency (CRADA Final Report)

The Sensor Suitcase project aimed to enable cost-effective, data-driven retro-commissioning (RCx) in small commercial buildings through a self-installable toolkit consisting of portable sensors and diagnostic software. Results showed that the Sensor Suitcase could identify common operational faults leading to 5–15% energy savings opportunities, with automated reports requiring minimal user interpretation. The project adhered closely to its Statement of Work (SOW) but evolved the reporting interface and sensor logging duration based on field feedback. The development and validation of diagnostics are documented in PNNL technical reports and internal analysis summaries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling hydrogen markets: Energy system model development status and decarbonization scenario results

Hydrogen can be used as an energy carrier and chemical feedstock to reduce greenhouse gas emissions, especially in difficult-to-decarbonize markets such as medium- and heavy-duty vehicles, aviation and maritime, iron and steel, and the production of fuels and chemicals. Significant literature has been accumulated on engineering-based assessments of various hydrogen technologies, and real-world projects are validating technology performance at larger scales and for low-carbon supply chains. While energy system models continue to be updated to track this progress, many are currently limited in their representation of hydrogen, and as a group they tend to generate highly variable results under decarbonization constraints. Here, the present work provides insights into the development status and decarbonization scenario results of 15 energy system models participating in study 37 of the Stanford Energy Modeling Forum (EMF37), focusing on the U.S. energy system. The models and scenario results vary widely in multiple respects: hydrogen technology representation, scope and type of hydrogen end-use markets, relative optimism of hydrogen technology input assumptions, and market uptake results reported for 2050 under various decarbonization assumptions. Most models report hydrogen market uptake increasing with decarbonization constraints, though some models report high carbon prices being required to achieve these increases and some find hydrogen does not compete well when assuming optimistic assumptions for all advanced decarbonization technologies. Across various scenarios, hydrogen market success tends to have an inverse relationship to success with direct air capture (DAC) and carbon capture and storage (CCS) technologies. While most model-scenario combinations predict modest hydrogen uptake by 2050 – <10 million metric tons (MMT) – aggregating the top 10 % of market uptake results across sectors suggests an upper range demand potential of 42–223 MMT. The high degree of variability across both modeling methods and market uptake results suggests that increased harmonization of both input assumptions and subsector competition scope would lead to more consistent results across energy system models. The wide variability in results indicates strongly divergent conclusions on the role of hydrogen in a decarbonized energy future.

08 HYDROGEN↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ionization states of low-energy cosmic rays - Results from Spacelab 3 cosmic-ray experiment

The Indian cosmic ray experiment Anuradha, conducted onboard Spacelab 3 during April 29-May 6, 1985 was designed to obtain information on the ionization states of low-energy cosmic rays, using the geomagnetic field as a rigidity filter to place an upper limit on the ionization state of individual cosmic ray particles. This paper presents data confirming the presence of three distinct groups of energetic particles in the near-earth space: (1) low-energy (15-25 MeV/nucleon) anomalous cosmic rays that are either singly ionized or consistent with their being in singly ionized state, (2) fully ionized galactic cosmic ray ions, and (3) partially ionized iron and sub-iron group ions (which account for about 20 percent of all the iron and sub-iron group ions detected at the Spacelab 3 orbit within the magnetosphere in the energy interval 25-125 MeV/nucleon). It is argued that these partially ionized heavy ions are indeed a part of the low-energy galactic cosmic rays present in the interplanetary space.

Dutta, A.↗

Greenhouse gas emissions reduction strategies that maximize portfolio-wide life cycle cost reduction, resilience, and environmental justice benefits

While strategies to achieve net-zero emissions at an individual site are well understood, new analysis methods are required for organizations seeking to achieve net-zero across multiple facilities, each with concurrent priority goals. At a portfolio level, distinct locations present varied challenges that cannot be addressed through singular solutions, and competing goals can take precedence with the assumption that net-zero emissions strategies deter from energy resilience and cost savings, therefore negatively impacting nearby communities. This study tests these assumptions by analyzing 16 diverse sites (varying in size, climate, and energy use) to identify strategies that reduce emissions and assess the impact these strategies have on life cycle costs, resilience, and communities with environmental justice concerns. Methods were developed to approximate missing information essential to net-zero evaluation. Established methods were augmented to evaluate life cycle costs, resilience, and environmental justice impacts across a set of strategies and accommodate the multi-criteria analyses. Potential benefits from identified strategies were quantified using site characteristics and a set of corresponding metrics. The net-zero analysis found that 11 sites could use on-site strategies to eliminate all but 2% of emissions generated. The remaining emissions can be offset, for instance through sequestration, executed at the portfolio scale. On-site carbon-free energy was found to reduce 51% of emissions across all sites; efficiency reduced 19% of emissions; sequestration 16%; procured carbon-free energy 15%; fuel switching 1.6%; and fleet electrification 1.3%. Building electrification, however, increased emissions by 4.4%. Different strategies also provide cost, resilience, and/or environmental justice benefits—the degree to which varies with individual site conditions. The findings indicate an advantage to considering the strategies as a comprehensive set, which leads to co-benefits, both in the ability to achieve net-zero goals and in advancing other goals. The results present the case for comprehensive advanced planning at the portfolio level to prioritize investments that will balance the minimization of emissions and life cycle cost with the maximization of resilience and environmental justice benefits. The novel methods for evaluation and integration, valuation of benefits, and consideration at the portfolio scale allow organizations to select investments that simultaneously address multiple key priorities.

Net-Zero Emissions↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Implementation of an ICS Ransomware Testbed: Scenarios, Variants, and Evaluation Methods

Ransomware attacks on Industrial Control Systems (ICS) have emerged as a formidable threat to the United States’ critical infrastructure, eliciting grave concerns regarding national security. In March 2023, the FBI Internet Crime Complaint Center (IC3) unveiled its 2022 Internet Crime Report, highlighting a concerning 870 complaints related to ransomware impacting U.S. critical infrastructure. Of the country's 16 critical infrastructure sectors, 14 encountered at least one ransomware attack. Notably, while the Healthcare and Public Health sector suffered the most, reporting 210 attacks, sectors pivotal to ICS networks and governmental organizations were also targeted: the Defense Industrial Base reported 1 attack, Water and Wastewater Systems 3, Chemical 19, Energy 15, Government Facilities 115, and Critical Manufacturing 157. For instance, a ransomware attack on a major chemical company could jeopardize not only its production but also pose environmental risks should systems controlling hazardous materials be compromised. In 2022, three ransomware variants predominantly targeted U.S. critical infrastructure: HIVE, with 87 attacks; ALPHV/BlackCat, with 114; and LOCKBIT, with 149. Several cyber-attacks, such as the MOVEit data breach in May 2023 and the Colonial Pipeline ransomware attack in May 2021, have been so impactful that they commanded national attention. The DarkSide hacking group's assault on the Colonial Pipeline, initiated on May 6th, 2021, stands as one of the most substantial and publicly acknowledged cyber-attacks against U.S. critical infrastructure. The group exploited an exposed Virtual Private Network (VPN) password, paving the way for initial intrusion and subsequent data theft. A mere day later, DarkSide unleashed a ransomware attack that compromised vital accounting and billing systems, prompting an immediate shutdown of the pipeline to mitigate further ransomware proliferation across its network. This crisis spurred a robust response from the U.S. president and regulators, culminating in a national emergency declaration related to the pipeline shutdown on May 9th, 2021. This incident mirrors the 2017 NotPetya ransomware attack that significantly impacted the shipping giant Maersk, highlighting an urgent need for fortified cybersecurity across various industries. Future incidents, akin to the Colonial Pipeline attack, could potentially be mitigated—or entirely averted—should government agencies and private entities scrutinize system vulnerabilities, exploring various ransomware types and entry points. Proactive measures, such as conducting experiments on VPN accounts or auditing passwords to pinpoint duplicate usage across diverse systems and software, might illuminate feasible entry points and vulnerability zones within an organization's systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Encounters with Jupiter - The Low Energy Charged Particle results of Voyager

Results of the Low Energy Charged Particle (LECP) experiments on board the Voyager spacecraft, designed to measure the fluxes and compositions of ions of energies 28 keV or greater and electrons of energies 15 keV or greater, during Jupiter encounter are presented. Observations of intense particle bursts coming from Jupiter several weeks before Jovian magnetosphere entry, magnetopause crossings, a hot corotating outer magnetospheric plasma, decreases in particle fluxes at the orbits of the Galilean satellites 10-hr particle flux periodicities and a magnetospheric wind are discussed. A new model of the Jovian magnetosphere based on the Voyager results is presented, and areas of continuing LECP Jovian data analysis are indicated.

Carbary, J. F.↗