Improved 235U, 238U, 239Pu, and 240Pu Photofission Cross Sections Across the GDR
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.
Photon-induced fission product yield (FPY) measurements were conducted on the isotope 238U. Fission was induced using Eγ = 13.0 MeV monoenergetic photons produced by the Triangle Universities Nuclear Laboratory’s (TUNL’s) High Intensity γ-ray Source (HIγS) facility. Short-lived FPYs were measured by performing cyclic activation of the sample using a rapid target transfer system. Following activation, the 238U target was rapidly (0.4 s) transferred to a counting station consisting of two well-shielded high-purity germanium (HPGe) detectors. The irradiation-counting cycle was repeated until the summed data had sufficient statistical accuracy. Twenty-eight unique fission products with half-lives ranging from 1 s to 450 s were identified, and their cumulative FPYs determined. Furthermore, the results are compared with previous independent FPY measurements using inverse kinematics. Good agreement between the data sets is found despite the different excitation energy distributions of the fissioning nucleus in the experiments.
Anefficient routine for computing Legendre moments of the Doppler-broadened elastic scattering kernel, including resonance scattering effects, has been implemented in the ISOXML module of Griffin. Isotropic scattering in the center-of-mass system and the ideal gas model for target motion are assumed. A ladder-operator formulation is introduced to compute all Legendre moments from order 0 to N simultaneously, enabling near-linear scaling of computational cost with respect to the maximum Legendre order. A physics-based strategy for constructing outgoing energy grids has also been developed, in which a tailored base grid is combined with adaptive refinement to maintain accuracy while limiting the number of outgoing energy points. For energies between resonances, a constant cross-section model is employed to further reduce computational cost. In addition, a quantitative criterion is derived to determine isotope-wise cut-off incident energies based on a prescribed up-scattering probability coverage. For 238U, up to incident energies of approximately 75, 230, and 661 eV at 294, 900, and 2500 K (corresponding to a 2% up-scattering probability threshold), computation of P0 kernels requires 1–8 s and computation of P0–P5 kernels requires 0.4–4 min using a single thread, while maintaining 1–3% relative error in up-scattering probability. These results demonstrate that the proposed formulation enables accurate and computationally practical Doppler-broadened kernel generation for online multigroup cross-section production in Griffin.
The ENDF/B-VIII.1 release is the newest evaluated nuclear data library produced, distributed, and recommended by CSEWG for use in nuclear science and technology applications. Among the many key advances, relative to the previous version ENDF/B-VIII.0, are: re-evaluation of 239Pu file by a joint international effort; updated 16,18O, 19F, 28-30Si, 50-54Cr, 55Mn, 54,56,57Fe, 63,65Cu, 139La, 233,235,238U, and 240,241Pu neutron nuclear data by the IAEA-coordinated INDEN collaboration; significant changes for 3He, 6Li, 9Be, 51V, 88Sr, 103Rh, 140,142Ce, Dy, 181Ta, Pt, 206-208Pb, and 234,236U neutron data; new nuclear data for the photo-nuclear, being 196 adopted from the IAEA2019 Photonuclear Data Library and one new file from JENDL-5; and new evaluations for the charged-particle and atomic sublibraries. Numerous thermal neutron scattering kernels were re-evaluated or provided for the very first time. Additionally, new covariance testing was implemented. ENDF/B-VIII.1 reduced bias in the simulations of many integral experiments with particular progress noted for fluorine, copper and stainless steel containing benchmarks. Data issues which had hindered the deployment of ENDF/B-VIII.0 for commercial nuclear power applications in high burn-up situations, were addressed. ENDF/B-VIII.1 data are distributed in both ENDF-6 and GNDS formats.
Neptunium-236g is a rare radionuclide used as a tracer for neptunium-237 analyses. The availability of 236gNp is limited and the viable production routes are costly, time consuming, and only produce trace quantities of the desired product. For this work, two known production methods were tested to determine product recovery, purity, and viability for use as a tracer. The first method utilizes a photon-irradiated 237Np target to produce 236gNp by the 237Np(?,n)?236Np reaction. The second method utilizes the 238U(d,4n) ?236Np reaction. These production routes were evaluated previously, and the former was considered ineffective without isotope separation and the latter was not well-characterized for the 236mNp/236gNp production ratio. Recent resurgence of electromagnetic isotope separation technology has enabled at least partial recovery of 236gNp from part-per-million abundance feeds produced by the photonuclear reaction. To address the lack of production data for the second method, a deuteron-irradiated depleted uranium target was chemically processed to recover and purify the Np for abundance and ratio analyses. The status and current analytical results for each production method are presented.
This report documents an evaluation of 238 U prompt fission neutron spectra (PFNS) which is a deliverable for a FY2024 Q4 NCSP (Nuclear Criticality Safety Program) milestone. This evaluation is new; its prior input is based on extended Los Alamos and exciton models implemented in the code CoH. Experimental covariances were estimated for five experimental data sets. One of these data sets that was measured by the Chi-Nu team of LANL and LLNL. It covers the 238 U PFNS for continuous incident-neutron energies of 1–20 MeV and outgoing-neutron energies from 10 keV– 10 MeV with high precision. Contrary to Chi-Nu data, previous data sets were measured in a limited energy range. The resulting evaluated data correspond well to the experimental PFNS taken into account for the evaluation. The evaluated PFNS also produce average mean energies in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of the Flattop, Flattop-Pu and BigTen ICSBEP critical assemblies (which all have thick reflectors with high percentages of 238 U), the differences of simulated values compared to those using ENDF/B-VIII.1β3 is modest (less than 25 pcm). In addition to that, the new PFNS predict on average 238 U LLNL pulsed-sphere neutron-leakage spectra slightly better than ENDF/BVIIII.0 and ENDF/B-VIII.1β3 PFNS. The differences are, however, well within the experimental uncertainties.