3D detector and electronics integration technologies: Applications to ILC, SLHC, and beyond
Abstract Not Provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
As a possible candidate for extremely radiation tolerant tracking devices we present a novel detector design - namely 3D detectors - based on poly-crystalline CVD diamond sensors with a pixel readout. The fabrication of recent 3D detectors as well their results in recent beam tests are presented. We measured the hit efficiency and signal response of two 3D diamond detectors with 50 × 50 μm cell sizes using pixel readout chip technologies currently used at CMS and ATLAS. In all runs, both devices attained efficiencies >98 % in a normal incident test beam of minimum ionising particles. The highest efficiency observed during the beam tests was 99.2 %.
We undertook, at Brookhaven National Laboratory (BNL), full 3D simulations of one-sided dual-type column 3D Si detectors (p-type substrate) after irradiation levels up to 1 x 10{sup 16} n{sub eq}/cm{sup 2}. Etching does not extend all the way through the substrate, so that all electrodes are on the front side; the backside was neither supported nor processed, covered only with a layer of silicon dioxide. Hence, BNL's one-sided dual-type column 3D detectors are true one-sided detectors. Our simulations of the electric fields at various fluences will add to our knowledge about the practicable applicability of these detectors in the high-radiation environment of future colliders. Simulations show that the full depletion voltage, V{sub fd}, for a dual-column 3D detector is about 1.4 times higher than that of a 2D (planar) pad detector with a thickness d, the same as the column spacing, L{sub p}, in the 3D detector. Moreover, the highest E-field is near the n{sup +} column, while the high E-field mainly is distributed between the n{sup +} and p{sup +} columns. The low E-field is between the two p{sup +} columns, with its lowest point in the center of the unit cell with two p{sup +} columns and two n{sup +} columns. To fully deplete a dual-column 3D detector at 1 x 10{sup 16} n{sub eq}/cm{sup 2} with a reasonable bias ({le} 200 V) necessitates reducing the column spacing, L{sub p}, to 30 {mu}m. The volume under the columns (10% of the total volume) can be depleted with a modest bias ({le}200 V); this underlying volume is not a dead volume. In addition, this depletion volume can support detection sensitivity directly under the columns, thereby lowering the effective dead volume in a 3D Si detector.
Explore the source record for details and available documents.
Semiconductor silicon detectors are used in many applications for detection and imaging of ionizing radiation. Detection of neutrons is also possible with these devices. However, the silicon detectors must be adapted for the thermal neutron detection and imaging. The devices must be supplemented with a material which 'converts ' neutrons into a radiation detectable directly in the semiconductor detector. The principle of the thermal neutron detection with semiconductor silicon detectors is explained. Advantages of such detectors are shown as well as their limitations. The way of the detector improvement using 3D detector technologies is described. The 3D detector properties were simulated; real 3D structures were fabricated and successfully tested with a beam of thermal neutrons, finally. The functionality of these devices was proved.
The planned luminosity upgrade of the CERN LHC to the super LHC (sLHC) requires investigation of new radiation hard tracking detectors. Compared to the LHC, tracking detectors must withstand a 5-10 times higher radiation fluence. Promising radiation hard options are planar silicon detectors with n-side readout and silicon detectors in 3D technology, where columnar electrodes are etched into the silicon substrate. This article presents beam test measurements per formed with planar and 3D n-in-p silicon strip detectors. The detectors were irradiated to different fluences, where the maximum fluence was 3 x 10{sup 15} 1 MeV neutron equivalent particles per square centimeter (n{sub eq}/cm{sup 2}) for the planar detectors and 2 x 10{sup 15} n{sub eq}/cm{sup 2} for the 3D detectors. In addition to signal measurements, charge sharing and resolution of both detector technologies are compared. An increased signal from the irradiated 3D detectors at high bias voltages compared to the signal from the unirradiated detector indicates that charge multiplication effects occur in the 3D detectors. At a bias voltage of 260 V, the 3D detector irradiated to 2 x 10{sup 15} n{sub eq}/cm{sup 2} yields a signal almost twice as high as the signal of the unirradiated detector. Only 30% of the signal of an unirradiated detector could be measured with the planar detector irradiated to 3 x 10{sup 15} n{sub eq}/cm{sup 2} at a bias voltage of 600 V, which was the highest bias voltage applied to this sensor.
μLaue diffraction with a polychromatic X-ray beam can be used to measure strain fields and crystal orientations of micro crystals. The hydrostatic strain tensor can be obtained once the energy profile of the reflections is measured. However, this remains a challenge both on the time scale and reproducibility of the beam position on the sample. In this review, we present a new approach to obtain the spatial and energy profiles of Laue spots by using a pn-junction charge-coupled device, an energy-dispersive area detector providing 3D resolution of incident X-rays. The morphology and energetic structure of various Bragg peaks from a single crystalline Cu micro-cantilever used as a test system were simultaneously acquired. The method facilitates the determination of the Laue spots’ energy spectra without filtering the white X-ray beam. The synchrotron experiment was performed at the BM32 beamline of ESRF using polychromatic X-rays in the energy range between 5 and 25 keV and a beam size of 0.5 μm × 0.5 μm. The feasibility test on the well known system demonstrates the capabilities of the approach and introduces the “3D detector method” as a promising tool for material investigations to separate bending and strain for technical materials.
Purpose: Patient-specific QA procedures for IMRT and VMAT are traditionally performed by comparing TPS calculations with measured single point values and plane dose distributions by means of gamma analysis. New QA devices permit us to calculate 3D dose distributions on patient anatomy as redundant secondary check and reconstruct it from measurements taken with 2D and 3D detector arrays. 3D dose calculations allow us to perform DVH-based comparisons with clinical relevance, as well as 3D gamma analysis. One of these systems (Compass, IBA Dosimetry) combines traditional 2D with new anatomical-based 3D gamma analysis. This work shows the ability of this system by comparing 2D and 3D gamma analysis in pre-treatment QA for several VMAT prostate plans. Methods: Compass is capable of calculating dose as secondary check from DICOM TPS data and reconstructing it from measurements taken by a 2D ion chamber array (MatriXX Evolution, IBA Dosimetry). Both 2D and 3D gamma tests are available to compare calculated and reconstructed dose in Compass with TPS RT Dose. Results: 15 VMAT prostate plans have been measured with Compass. Dose is reconstructed with Compass for these plans. 2D gamma comparisons can be done for any plane from dose matrix. Mean gamma passing rates for isocenter planes (axial, coronal, sagittal) are (99.7±0.2)%, (99.9±0.1)%, (99.9±0.1)% for reconstructed dose planes. 3D mean gamma passing rates are (98.5±1.7)% for PTVs, (99.1±1.5)% for rectum, (100.0±0.0)% for bladder, (99.6±0.7)% for femoral heads and (98.1±4.1)% for penile bulb. Conclusion: Compass is a powerful tool to perform a complete pre-treatment QA analysis, from 2D techniques to 3D DVH-based techniques with clinical relevance. All reported values for VMAT prostate plans are in good agreement with TPS values. This system permits us to ensure the accuracy in the delivery of VMAT treatments completing a full patient-specific QA program.
During this project our group has succeeded in producing and measuring a number of 3D diamond devices. We have worked with manufacturers and shown that poly-crystalline CVD (pCVD) diamond can be grown reliably with a 5% uniformity in industry. We have produced 3D diamond devices and scaled up the production technology from roughly 100 cells on a device to 4000 cells on a device. We have increased the column yield from 92% to 99%. We have reduced the cell size from our safe initial choice 150μm x 150μm cells to the HL-LHC size of 50μm x 50μm cells. We have reduced the column diameter from 6-10 μm to 2.6 μm. In beam tests we have quantified the amount of charge each 3D device yields for minimizing ionizing particles and compared this to that produced by a planar diamond device. Very recently, we produced the first 3D diamond pixel devices read out with both ATLAS and CMS pixel electronics, tested them in particle beams at CERN and PSI. Finally we have successfully tested the first irradiated 3Ddiamond device after a fluence of 3.5 x 10 15 800 MeV p/cm 2 .
In collaboration between the University of Michigan and Los Alamos National Laboratory, a 3D position-sensing CdZnTe (CZT) detector prototype was built and integrated into a high-altitude balloon platform to evaluate its performance in a space-like mixed-radiation environment. The detector prototype, Orion Eagle, was designed to operate in near-vacuum environments without any temperature regulation. Orion Eagle was hand-launched from NASA’s Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM on September 26, 2021, and successfully operated throughout a 9-hour flight, which reached 38.5 km in altitude. The flight met its objectives, successfully detecting atmospheric gamma rays and galactic cosmic rays, and raising the Technical Readiness Level from 4 to 6 for large-volume 3D CZT detector technology for space applications. Ionization tracks produced by charged particles create spatial signatures in the detector that are distinguishable from discrete gamma-ray interactions. Therefore, the 3D position-sensing capabilities using pixelated electrodes on a CZT detector can help enable discrimination of background charged particles from gamma-ray events without an anticoincidence shield. The potential for background rejection capability, ambient-temperature operation, gamma-ray coded-aperture and Compton imaging, and near High Purity Germanium (HPGe) energy resolution motivate the use of large-volume 3D CZT imaging spectrometers in future space missions.
The ATLAS Forward Physics (AFP) project aims to measure protons scattered under a small angle from the pp collisions in ATLAS. In order to perform such measurements, a new silicon tracker, together with a time-of-flight detector for pile-up removal, are planned to be installed at ∼210 m from the interaction point and at 2-3 mm from the LHC proton beam. To cope with such configuration and maximize the physics outcome, the tracker has to fulfil three main requirements: endure highly non-uniform radiation doses, due to the very inhomogeneous beam profile, have slim and efficient edges to improve the acceptance of the tracker, and provide good position resolution. Recent laboratory and beam test characterization results of AFP prototypes will be presented. Slim-edged 3D pixel detectors down to 100-200 μm were studied and later non-uniformly irradiated (with a peak fluence of several 10{sup 15} n{sub eq}/cm{sup 2}) to determine the fulfilment of the AFP requirements. (authors)
In this study, the requirements to achieve high detection efficiency (above 50%) and gigahertz (GHz) frame rate for the proposed 42-keV X-ray free-electron laser (XFEL) at Los Alamos are summarized. Direct detection scenarios using C (diamond), Si, Ge and GaAs semiconductor sensors are analyzed. Single-photon counting (SPC) mode and weak SPC mode using Si can potentially meet the efficiency and frame rate requirements and be useful to both photoelectric absorption and Compton physics as the photon energy increases. Multilayer three-dimensional (3D) detector architecture, as a possible means to realize SPC modes, is compared with the widely used two-dimensional (2D) hybrid planar electrode structure and 3D deeply entrenched electrode architecture. Demonstration of thin film cameras less than 100-μm thick with onboard thin ASICs could be an initial step to realize multilayer 3D detectors and SPC modes for XFELs.
The Super-LHC upgrade puts strong demands on the radiation hardness of the innermost tracking detectors of the CMS, which cannot be fulfilled with any conventional planar detector design. The so-called 3D detector architectures, which feature columnar electrodes passing through the substrate thickness, are under investigation as a potential solution for the closest operation points to the beams, where the radiation fluence is estimated to reach 10{sup 16} n{sub eq}/cm{sup 2}. Two different 3D detector designs with CMS pixel readout electronics are being developed and evaluated for their advantages and drawbacks. The fabrication of full-3D active edge CMS pixel devices with p-type substrate has been successfully completed at SINTEF. In this paper, we study the expected post-irradiation behaviors of these devices with simulations and, after a brief description of their fabrication, we report the first leakage current measurement results as performed on wafer.
This paper reports on the current status of the development of International Linear Collider vertex detector pixel readout chips based on multi-tier vertically integrated electronics. Initial testing results of the VIP2a prototype are presented. The chip is the second embodiment of the prototype data-pushed readout concept developed at Fermilab. The device was fabricated in the MIT-LL 0.15 {micro}m fully depleted SOI process. The prototype is a three-tier design, featuring 30 x 30 {micro}m{sup 2} pixels, laid out in an array of 48 x 48 pixels.
Purpose: Lung SBRT is being used by an increasing number of clinics, including our center which recently treated its first patient. In order to validate this technique, the 3D dose distribution of the SBRT plan was measured using a previously developed 3D detector based on plenoptic camera and plastic scintillator technology. The excellent agreement between the detector measurement and the expected dose from the treatment planning system Pinnacle{sup 3} shows great promise and amply justify the development of the technique. Methods: The SBRT treatment comprised 8 non-coplanar 6MV photon fields with a mean field size of 12 cm{sup 2} at isocentre and a total prescription dose of 12Gy per fraction for a total of 48Gy. The 3D detector was composed of a 10×10×10 cm{sup 2} EJ-260 water-equivalent plastic scintillator embedded inside a truncated cylindrical acrylic phantom of 10cm radius. The scintillation light was recorded using a static R5 light-field camera and the 3D dose was reconstructed at a 2mm resolution in all 3 dimensions using an iterative backprojection algorithm. Results: The whole 3D dose distribution was recorded at a rate of one acquisition per second. The mean absolute dose difference between the detector and Pinnacle{sup 3} was 1.3% over the region with more than 10% of the maximum dose. 3D gamma tests performed over the same region yield passing rates of 98.8% and 96.6% with criteria of 3%/1mm and 2%/1mm, respectively. Conclusion: Experimental results showed that our beam modeling and treatment planning system calculation was adequate for the safe administration of small field/high dose techniques such as SBRT. Moreover, because of the real-time capability of the detector, further validation of small field rotational, dynamic or gated technique can be monitored or verified by this system.
Silicon sensors with a three-dimensional (3-D) architecture, in which the n and p electrodes penetrate through the entire substrate, have many advantages over planar silicon sensors including radiation hardness, fast time response, active edge and dual readout capabilities. The fabrication of 3D sensors is however rather complex. In recent years, there have been worldwide activities on 3D fabrication. SINTEF in collaboration with Stanford Nanofabrication Facility have successfully fabricated the original (single sided double column type) 3D detectors in two prototype runs and the third run is now on-going. This paper reports the status of this fabrication work and the resulted yield. The work of other groups such as the development of double sided 3D detectors is also briefly reported.
The invention utilizes one exposure without moving parts to provide multiple x-ray views of an object. It relies on a 3D detector, which can be a stack of film plates, and a specified focusing x-ray optic. The x-ray optic, discussed below, allows collection of x-rays from a localized volume, just like an ordinary optical lens, and the stacked film plate, or other 3D detector design, allows collection of the multiple focal plane information from one line of sight.
We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 {micro}s, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.