3D Seismic Reflection Attributes of a Geothermal Area
Images from a 3D seismic reflection survey across a geothermal area are shown. Images of coherency and acoustic impedance are shown. Well tracks and MEQ location are overlain.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Images from a 3D seismic reflection survey across a geothermal area are shown. Images of coherency and acoustic impedance are shown. Well tracks and MEQ location are overlain.
Prestack reverse time migration (RTM) is a method for imaging the subsurface using the inner product of wavefield extrapolation in shot domain and in receiver domain. It is well known that RTM is better for preserving amplitudes and phases than other prestack migrations. Since 3D seismic data is huge data volume and it needs heavy computing works, it requires parallel computing in order to have a meaningful depth image of the 3D subsurface. We implemented a parallelized version of 3D RTM for prestack depth migration. The results of numerical example for 3D SEG/EAGE salt model showed good agreement with the original geological model. We applied RTM to offshore 3D seismic reflection data. The study area is 12 × 25 km with 120 survey lines. Shot and receiver spacing is 25 m and 12.5 m. The line spacing is 100 m. Shot gathers were preprocessed to enhance signal to noise ratio and velocity model was calculated from conventional stack velocity. Both of them were used to obtain 3D image using RTM. The results show reasonable subsurface image.
This is 2D and 3D seismic reflection data from Utah FORGE reprocessed during Phase 2c. The readme file containing an explanation of the data including data formats, software that can be used, processing, and projection and datum used. The Reprocessing document gives the rationale for reprocessing and shows examples of the improvements that were obtained. For all 3D and 2D data the following datasets were created and output in SEG-Y format: - Unmigrated Time - Prestack Time Migration (PSTM), Unenhanced (UnEnh) and Enhanced (Enh) - Prestack Depth Migration (PSDM), Unenhanced (UnEnh) and Enhanced (Enh) - Velocity Model used for Migration
Abstract: This geophysical monitoring review is intended to lay the ground work for an approach to integrating monitoring strategies with risk assessment and risk reduction and to summarize work conducted by U.S. Department of Energy's National Risk Assessment Partnership (NRAP) participants that addresses key questions related to monitoring strategies. Commercial, demonstration and pilot geologic CO2 storage (GCS) projects have provided a wealth of practical experience in monitoring technologies. In this manuscript we review a few key projects, specific geophysical methods, well-based methods, geophysical workflows and some suggested best practices. These practices are often driven and governed by regulatory requirements (e.g. U.S. Environmental Protection Agency [US-EPA] Class VI underground injection regulation) and the need for effective reservoir management of pressures and volumes as well as the site-specific risks to containment, plume migration, and underground sources of drinking water. Reducing uncertainty in monitoring is likely to lead to reducing uncertainty in risk. One of our conclusions is the need for field experiment testing that is risk-driven. It is notable that GCS pilot projects have been designed for safe storage, and to date they have been successful. Technical challenges at all geologic CO2 storage sites include assuring injectivity and capacity predictions are reliable, the fate and subsurface topology of the CO2 plume is acceptable, regulatory permitting and compliance are accomplished in a timely manner, needed business assurances are supported by quantitative technical data, and the storage operation is acceptable to stakeholders. There is risk associated with all of these challenges necessitating a monitoring program utilizing both direct and indirect monitoring methods. Because of the direct association of risk and monitoring in GCS, geophysical monitoring is viewed as a key component in approaching risk assessment. To address monitoring in the context of risk assessment the U.S. Department of Energy's National Risk Assessment Partnership (NRAP) has undertaken a review of work related to monitoring storage sites. In this review we provide a framework for monitoring and then present some specific monitoring tools that may be useful for regulatory compliance, as well as technologies that are applicable to leakage detection.
Woolsey Mound, located at Mississippi Canyon Lease Block 118 (MC118), is the site of the Gulf of Mexico hydrate research consortium’s seafloor observatory, where gas hydrates outcrop at the seafloor. The presence of gas hydrates in the mound is confirmed directly by coring and indirectly by 3D seismic reflection data. Craters, pockmarks, chemosynthetic communities, and authigenic carbonates populate the seafloor at Woolsey Mound. Each crater is characterized by a network of shallow crestal faults that connect the hydrate mound to the underlying allochthonous salt body. We characterize the temporal and spatial evolution of gas hydrates at Woolsey Mound under natural perturbations using four collocated 3D seismic reflection data sets that span over 14 years. Data acquisition differences embedded in the data sets arising from variation in geometry, sample rate, and phase are minimized using the “cross-equalization” method. Our results indicate that hydrate formation and dissociation vary temporally and spatially in close connection to the shallow crestal faults. Evidence of gas hydrate dissociation is observed over a period of three years (2000–2003), where major dissociation occurred along the southern portion of the crestal fault in the southeast crater. The dissociation is less prominent in the southwest crater. Evidence of methane venting is observed between 2000 and 2010, which is mostly concentrated in the southeast crater. The residual amplitude anomalies observed between 2000 and 2014 in the mound are mostly positive, implying that the methane venting had increased significantly. The positive anomalies are correlated with the methane seepage recorded in 2011. Our results indicate the evolution of a fault-controlled gas hydrate system in the northern Gulf of Mexico, which would aid in assessing its impact on the seafloor.
Amplitude images (both vertical and depth slices) extracted from 3D seismic reflection survey over area of Walker Ranch area (adjacent to Raft River). Crossline spacing of 660 feet and inline of 165 feet using a Vibroseis source. Processing included depth migration. Micro-earthquake hypocenters on images. Stratigraphic information and nearby well tracks added to images. Images are embedded in a Microsoft Word document with additional information. Exact location and depth restricted for proprietary reasons. Data collection and processing funded by Agua Caliente. Original data remains property of Agua Caliente.
The results of monitoring of carbon dioxide (CO 2 ) injection at the Illinois Basin—Decatur Project (IBDP) and the companion Illinois Industrial Carbon Capture and Sequestration Sources (IL-ICCS) project—have shown that reservoir response to fluid pressure changes can vary significantly at different injection locations within the same reservoir. Predrill reservoir characterization is important to identify potentially seismogenic faults. However, interpretations of newly reprocessed 3D seismic reflection data illustrate the challenges related to their identification in a region dominated by faulting with small vertical offsets. Faults interpreted in the 3D seismic volume range from ~300 to 1200 m wide and are in the same size range as faults that could have been the source of historical events up to Mw 2.7 in central Illinois. The array of monitoring sensors that was installed for the IBDP continues to collect data, as injection operates in IL-ICCS, the second injection well. CO 2 injection rates for the IL-ICCS well are on average 1.7 times the rates injected in the IBDP well, but a significantly reduced rate of induced seismicity is observed. This article presents results of passive seismic monitoring for the duration of the project to date, integrating active and passive seismic data to develop a new interpretation of the subsurface structure at the Decatur site that explicitly identifies pathways for fluid flow into the basement leading to induced seismicity, and provides a geological explanation for the sharp reduction of induced seismicity during injection at higher rates into the second well. The use of seismic moment to estimate the length of seismogenic slip planes in the local subsurface suggests that faults large enough to produce felt seismicity are unlikely to be present at or near the Decatur site.
Well logs and 3D seismic reflection data are integrated to image Lower Miocene depocenters of the upper Texas and westernmost Louisiana coastal and offshore areas. Although previously interpreted at a large scale (3rd order cycles), the detailed stratigraphy and depositional history of the early Miocene succession has not been fully developed. The upper lower Miocene interval from Robulus L (MFS10) to Amphistegina B (MFS9) has been further subdivided into five 4th order cycles (each 200 to 300 m thick) to provide finer scale stratigraphic detail and interpretation of depositional environments. Results of the finer scale correlations are presented in a series of sandstone percent maps. Overall, the maps display a strike-elongate (sub-parallel to the present day coastline) orientation for the sandstone bodies which thin to the southeast (basinward). Net sandstone thickness is relatively low in older cycles and increases in younger cycles suggesting an overall progradation of the deltaic system into the mapped area through time. Continued marine regression and southward movement of the shoreline are also confirmed by seismic amplitude 2 maps. After a major transgression associated with Robulus L deltaic progradation occurred under rising sea level conditions. Deltaic sediments prograded southward and sandstone brought to the upper Texas coast was distributed laterally by longshore currents to form strandplain coast lines. Maximum regression occurred during the interval MFS9_2 to MFS9_3 when a deltaic depocenter formed offshore Texas in east High Island area. However, sandstone thickness progressively decreased laterally to the east (offshore Louisiana) where more shale was present and marine processes reworked deltaic derived sandstones into shore parallel bars. There was a clear retreat of the shoreline during the youngest cycle marking the beginning of transgression associated with Amphistegina B . Detailed stratigraphic interpretation (at a 4th order scale) shows more variability in the dominant shoreline processes during early Miocene than previously thought. Recognition of sedimentary systems variability at a 4th order scale is critical for improved hydrocarbon exploration and in understanding potential future CO 2 storage in the area.
This study reports on analyses of natural, geologic CO 2 migration paths in Farnsworth Oil Field, northern Texas, where CO 2 was injected into the Pennsylvanian Morrow B reservoir as part of enhanced oil recovery and carbon sequestration efforts. We interpret 2D and 3D seismic reflection datasets of the study site, which is located on the western flank of the Anadarko basin, and compare our seismic interpretations with results from a tracer study. Petroleum system models are developed to understand the petroleum system and petroleum- and CO 2 -migration pathways. We find no evidence of seismically resolvable faults in Farnsworth Field, but interpret a karst structure, erosional structures, and incised valleys. These interpretations are compared with results of a Morrow B well-to-well tracer study that suggests that inter-well flow is up-dip or lateral. Southeastward fluid flow is inhibited by dip direction, thinning, and draping of the Morrow B reservoir over a deeper, eroded formation. Petroleum system models predict a deep basin-ward increase in temperature and maturation of the source rocks. In the northwestern Anadarko Basin, petroleum migration was generally up-dip with local exceptions; the Morrow B sandstone was likely charged by formations both below and overlying the reservoir rock. Based on this analysis, we conclude that CO 2 escape in Farnsworth Field via geologic pathways such as tectonic faults is unlikely. Abandoned or aged wellbores remain a risk for CO 2 escape from the reservoir formation and deserve further monitoring and research.
Seismic reflection the primary tool used in petroleum exploration and production, but use in geothermal exploration is less standard, in part due to cost but also due to the challenges in identifying the highly-permeable zones essential for economic hydrothermal systems [e.g. Louie et al., 2011; Majer, 2003]. Newer technology, such as wireless sensors and low-cost high performance computing, has helped reduce the cost and effort needed to conduct 3D surveys. The second difficulty, identifying permeable zones, has been less tractable so far. Here we report on the use of seismic attributes from a 3D seismic survey to identify and map permeable zones in a hydrothermal area.
All datasets and products specific to the Steptoe Valley model area. Includes a packed ArcMap project (.mpk), individually zipped shapefiles, and a file geodatabase for the northern Steptoe Valley area; a GeoSoft Oasis montaj project containing GM-SYS 2D gravity profiles along the trace of our seismic reflection lines; a 3D model in EarthVision; spreadsheet of links to published maps; and spreadsheets of well data.
All datasets and products specific to the Carson Sink Basin. Includes a packed ArcMap (.mpk), individually zipped shapefiles, and a file geodatabase for the Carson Sink area; a GeoSoft Oasis montaj project containing GM-SYS 2D gravity profiles along the trace of our seismic reflection lines; a 3D model in EarthVision; spreadsheet of links to published maps; and spreadsheets of well data.
The complex postdetonation geologic structures that form after an underground nuclear explosion are difficult to constrain because increased heterogeneity around the damage zone affects seismic waves that propagate through the explosion site. Generally, a vertical rubble-filled structure known as a chimney is formed after an underground nuclear explosion that is composed of debris that falls into the subsurface cavity generated by the explosion. Compared with chimneys that collapse fully, leaving a surface crater, partially collapsed chimneys can have remnant subsurface cavities left in place above collapsed rubble. The 1964 nuclear test HADDOCK, conducted at the Nevada test site (now the Nevada National Security Site), formed a partially collapsed chimney with no surface crater. Understanding the subsurface structure of these features has significant national security applications, such as aiding the study of suspected underground nuclear explosions under a treaty verification. In this study, we investigated the subsurface architecture of the HADDOCK legacy nuclear test using hybrid 2D–3D active source seismic reflection and refraction data. The seismic data were acquired using 275 survey shots from the Seismic Hammer (a 13,000 kg weight drop) and 65 survey shots from a smaller accelerated weight drop, both recorded by ~1000 three-component 5 Hz geophones. First-arrival, P-wave tomographic modeling shows a low-velocity anomaly at ~200 m depth, likely an air-filled cavity caused by partial collapse of the rock column into the temporary postdetonation cavity. A high-velocity anomaly between 20 and 60 m depth represents spall-related compaction of the shallow alluvium. Hints of low velocities are also present near the burial depth (~364 m). The reflection seismic data show a prominent subhorizontal reflector at ~300 m depth, a short-curved reflector at ~200 m, and a high-amplitude reflector at ~50 m depth. Comparisons of the reflection sections to synthetic data and borehole stratigraphy suggest that these features correspond to the alluvium–tuff contact, the partial collapse cavity, and the spalled layer, respectively.
Most geothermal resources in the Great Basin region of the western USA are blind, and thus the discovery of new commercial-grade systems requires synthesis of favorable characteristics for geothermal activity. The geothermal play fairway concept involves integration of multiple parameters indicative of geothermal activity to identify promising areas for new development. This project integrated multiple datasets to apply the play fairway concept and assess geothermal potential in a large region of the Great Basin in Nevada. It is therefore referred to as the Nevada play fairway project. This project was a strong collaborative effort between several organizations, led by the Nevada Bureau of Mines and Geology at the University of Nevada, Reno, but with key support from the U.S. Geological Survey, ATLAS Geosciences, Inc,, Hi-Q Geophysical, Inc., Lawrence Berkeley National Laboratory, Utah Geological Survey, and Innovative Geothermal Ltd. In Budget Period 1 of this project, available data for nine geologic, geochemical, and geophysical parameters were initially synthesized to produce a new detailed geothermal potential map of 96,000 km2 from west-central to eastern Nevada. These parameters were grouped into subsets and individually weighted to delineate rankings for local permeability, intermediate permeability, regional permeability, and thermal potential, which collectively defined geothermal play fairways (i.e., most likely locations for significant geothermal fluid flow). This initial work was aimed at reducing the risks in regional exploration and therefore facilitating discovery of new commercial-grade systems in blind settings, as well as in areas with surface expressions of geothermal activity. Budget Period 2 of the project involved detailed analysis of some of the most promising areas identified in Phase 1. Twenty-four highly prospective areas, including both known undeveloped systems and previously undiscovered potential blind systems, were identified for further analysis. After reconnaissance of these areas, five of the most promising sites were selected for detailed studies. Multiple techniques were employed in the detailed studies, including geologic mapping, shallow temperature surveys, gravity surveys, Lidar, geochemical studies, seismic reflection analysis, and 3D modeling. The goal of the detailed studies was to identify specific areas with the highest likelihood for high permeability and thermal fluids, such that drill sites could be targeted. Three main sets of predictive maps were generated for each detailed study area: 1) play fairway maps, 2) play fairway error maps, and 3) direct evidence maps. Local- and intermediate-scale permeability models were revised to reflect results of the detailed geologic, geophysical, and geochemical analyses. Budget Period 3 of the project involved more detailed geophysical analyses and temperature-gradient (TG) drilling in southeastern Gabbs Valley and northern Granite Springs Valley, deemed the two most promising sites, with the goal of providing preliminary validation of the play fairway methodology. In southeastern Gabbs Valley, the collocation of a favorable structural setting (displacement transfer zone and fault intersections), Quaternary faults, intersecting and terminating gravity gradients, magnetic low, shallow (2 m) temperature anomaly, low resistivity anomaly, and promising geothermometry from nearby water wells provided evidence for a blind system. Drilling of six TG holes defines an apparent geothermal system at this locality with temperatures as high as 124°C at 152 m. This system is blind, with no surface hot springs, fumaroles, or paleo-geothermal deposits. For northern Granite Springs Valley, a favorable structural setting (termination of a major Quaternary normal fault), terminating gravity gradient, magnetic gradient, newly discovered sinter deposits, nearby warm water wells, previously drilled TG holes in the vicinity, and promising geothermometry suggest a hidden system. Drilling of six new TG holes yields temperatures of ~96°C at ~250 m, suggesting the presence of a geothermal system. Major lessons learned in the course of this project include: 1) initially identified sites commonly include multiple favorable structural settings at a finer scale; 2) promising sites in Cenozoic basins cannot be recognized without detailed geophysical surveys; and 3) play fairway analysis should be refined as the exploration program vectors into the most promising sites and finer-scale data are acquired. In addition to producing copious amounts of data, this project resulted in 16 published papers, 10 abstracts, more than 40 presentations across the U.S. and abroad (including several keynote addresses), 2 Masters theses, and 7 media reports.
The Great Basin region of the western USA is capable of producing much greater amounts of geothermal energy than the current ~670 MW from ~25 power plants. Most geothermal resources in this region are blind, and thus the favorable characteristics for geothermal activity must be synthesized and methodologies need to be developed to discover new commercial-grade systems. In the Nevada play fairway project, nine geologic, geochemical, and geophysical parameters were synthesized to produce a new detailed geothermal potential map of 96,000 km2 from west-central to eastern Nevada. These parameters were grouped into subsets and individually weighted to delineate rankings for local permeability, regional permeability, and heat, which collectively defined geothermal play fairways (i.e., most likely locations for significant geothermal fluid flow). This work is aimed at reducing the risks in geothermal exploration and therefore facilitating discovery of new commercial-grade systems in blind settings, as well as in areas with surface expressions of geothermal activity. Twenty-four highly prospective areas, including both known undeveloped systems and previously undiscovered potential blind systems, were identified across the region for further analysis. Five of the most promising sites have been selected for detailed studies: Granite Springs Valley, Sou Hills, southern Gabbs Valley, Crescent Valley, and Steptoe Valley. Multiple techniques, including detailed geologic mapping, shallow temperature surveys, detailed gravity surveys, LiDAR, geochemical studies, seismic reflection analysis, and 3D modeling, are now being employed in these areas. The ultimate goal of these detailed studies is to determine the most likely areas for high permeability thermal fluids such that potential drill sites can be targeted. Potential new blind systems discovered in this project include southern Gabbs Valley and Granite Springs Valley currently undergoing detailed study, as well as step-overs in the Dun Glen area and along the west flank of the Humboldt Range.
Estimates suggest that the Great Basin region is capable of producing much greater amounts of geothermal energy than the current ~600 MW from ~24 power plants. Because most of the geothermal resources in this region are blind, it is imperative that the favorable characteristics for geothermal activity be synthesized and methodologies developed to discover new robust systems. Nine geologic, geochemical, and geophysical parameters were synthesized to produce a new detailed geothermal play fairway map of a large transect across the Great Basin region (96,000 km2) from west-central to eastern Nevada. These parameters were grouped into subsets to delineate rankings for local permeability, regional permeability, and heat, which collectively defined geothermal play fairways (i.e., most likely locations for significant geothermal fluid flow). The primary objective of this work was to reduce the risks in geothermal exploration and thus facilitate discovery of commercial-grade, blind geothermal fields. Two dozen highly prospective areas, including both known systems and previously undiscovered potential blind systems, have been identified across the region for further analysis, of which several will be selected for detailed studies. Multiple techniques, including detailed geologic mapping, shallow temperature surveys, detailed gravity surveys, LiDAR, geochemical studies, seismic reflection analysis, and 3D modeling, are being employed in the detailed studies. Initial work on the detailed studies has begun and will proceed over the next year.
The Great Basin of the western USA is capable of producing much greater amounts of geothermal energy than the current ~670 MW from ~25 power plants. Most geothermal resources in this region are blind, and thus the favorable characteristics for geothermal activity must be synthesized and methodologies developed to discover new commercial-grade systems (>130oC). The geothermal play fairway concept involves integration of multiple parameters indicative of geothermal activity as a means of identifying promising areas for new development. In the Nevada play fairway project, nine geologic, geochemical, and geophysical parameters were initially synthesized to produce a new geothermal potential map of 96,000 km2. These parameters were grouped into subsets and individually weighted to delineate rankings for heat and local, intermediate, and regional permeability, which collectively defined the play fairways. From the regional map, 24 highly prospective areas, including known undeveloped systems and unknown potential blind systems, were identified for further analysis. Five particularly promising sites were then selected for detailed studies. Multiple techniques, including geologic mapping, Quaternary fault analysis, 2-m temperature surveys, gravity surveys, LiDAR, geochemical studies, seismic reflection analysis, and 3D modeling, were employed in these areas to define likely sites for high permeability and define highly prospective drilling targets. Local and intermediate permeability models were revised to reflect results of detailed analyses and generate new detailed play fairway maps. Lessons learned include: 1) initially identified sites commonly include multiple favorable settings at a finer scale; 2) promising sites in Cenozoic basins cannot be recognized without detailed geophysical surveys; and 3) play fairway analysis is critical at multiple scales, providing a means to select regional prospects as well as vectoring into drilling targets at individual sites. Based on our detailed studies, several potential new, high temperature systems were discovered. However, TG drilling is needed to confirm commercial grade resources.
We have evaluated the concept of practicing S-wave reflection seismology with legacy 3D seismic data generated by a P-wave source and recorded with only vertical geophones. This type of S-wave imaging is based on the principle that seismic P-wave sources not only produce a downgoing illuminating P wavefield, but they also simultaneously produce a downgoing illuminating SV wavefield that, in almost all cases, is suitable for S-wave reflection imaging. The S-mode used in this study is the SV-P, or converted-P, mode. This mode involves a downgoing illuminating SV wavefield and an upgoing reflected P-mode that is recorded by vertical geophones. In flat-layered stratigraphy, the lengths of the SV and P raypaths in SV-P imaging are identical to the lengths of the SV and P raypaths in P-SV imaging with P-sources and 3C geophones. P-SV imaging of deep rocks has been practiced for more than two decades; SV-P imaging is a new concept. SV-P data should provide the same options for investigating deep rocks as do P-SV data. We have determined one of the equivalences between SV-P data extracted from vertical-geophone data and P-SV data extracted from horizontal geophones: that both modes react to azimuth-dependent variations in the S velocity in anisotropic rocks. Azimuthal variations in the SV-P traveltime can be used to define the polarization direction of the fast-S-wave mode, which is also the azimuth of the maximum horizontal stress (SHmax). Our investigation demonstrates a noninvasive method for monitoring changes in the SHmax azimuth across a CO 2 storage reservoir, or any targeted porous rock, as fluids are cycled into, and then out of, that rock’s pore space.