Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PhotoSketch: a photocentric urban 3D modeling system

Online mapping services from Google, Apple, and Microsoft are exceedingly popular applications for exploring 3D urban cities. Their explosive growth provides impetus for photorealistic 3D modeling of urban scenes. Although classical algorithms such as multiview stereo and laser range scanners are traditional sources for detailed 3D models of existing structures, they generate heavyweight models that are not appropriate for the streaming data that these navigation applications leverage. Instead, lightweight models as produced by interactive image-based tools are better suited for this domain. The contribution of this work is that it merges the benefits of multiview geometry, an intuitive sketching interface, and dynamic texture mapping to produce lightweight photorealistic 3D models of buildings. We present experimental results from urban scenes using our PhotoSketch system.

3D photography↗

Commissioning and benchmarking a 3D dosimetry system for clinical use

Purpose: A 3D dosimetry system is described which consists of two parts: a radiochromic plastic dosimeter PRESAGE (which responds to absorbed dose with a linear change in optical-density) and the Duke large-field-of-view optical-CT scanner (DLOS). The DLOS/PRESAGE system has recently been commissioned and benchmarked for clinical use and, in particular, for verification and commissioning of complex radiation treatments. Methods: DLOS commissioning involved determining the dynamic range, spatial resolution, noise, temporal, and other characteristics of the light source and imaging components. Benchmarking tests were performed on the combined DLOS/PRESAGE system to establish baseline dosimetric performance. The tests consisted of delivering simple radiation treatments to PRESAGE dosimeters, and comparing the measured 3D relative dose distributions with the known gold standard. The gold standard distribution was obtained from machine beam-data or the treatment planning system (TPS). All studies used standardized procedures to ensure consistency. Results: For commissioning, isotropic spatial resolution was submillimeter (MTF > 0.5 for frequencies of 1.5 lp/mm) and the dynamic range was {approx}60 dB. Flood field uniformity was within 10% and stable after 45 min of warm-up. Stray-light is small, due to telecentricity, but even the residual can be removed through deconvolution by a point-spread-function. For benchmarking, the mean 3D passing NDD (normalized dose distribution) rate (3%, 3mm, 5% dose threshold) over the benchmark data sets was 97.3% {+-} 0.6% (range 96%-98%), which is on par with other planar dosimeters used in external beam radiation therapy indicating excellent agreement. Noise was low at <2% of maximum dose (4-12 Gy) for 2 mm reconstructions. The telecentric design was critical to enabling fast imaging with minimal stray-light artifacts. Conclusions: This work presents the first comprehensive benchmarking of a 3D dosimetry system for clinical use. The DLOS/PRESAGE benchmark tests show consistently good agreement to simple known distributions. The system produces accurate isotropic 2 mm dose data over clinical volumes (e.g., 16 cm diameter phantoms, 12 cm height), in under 15 min. It represents a uniquely useful and versatile new tool for commissioning and verification of complex therapy treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comprehensive evaluation of the PRESAGE/optical-CT 3D dosimetry system

This work presents extensive investigations to evaluate the robustness (intradosimeter consistency and temporal stability of response), reproducibility, precision, and accuracy of a relatively new 3D dosimetry system comprising a leuco-dye doped plastic 3D dosimeter (PRESAGE) and a commercial optical-CT scanner (OCTOPUS 5x scanner from MGS Research, Inc). Four identical PRESAGE 3D dosimeters were created such that they were compatible with the Radiologic Physics Center (RPC) head-and-neck (H and N) IMRT credentialing phantom. Each dosimeter was irradiated with a rotationally symmetric arrangement of nine identical small fields (1x3 cm{sup 2}) impinging on the flat circular face of the dosimeter. A repetitious sequence of three dose levels (4, 2.88, and 1.28 Gy) was delivered. The rotationally symmetric treatment resulted in a dose distribution with high spatial variation in axial planes but only gradual variation with depth along the long axis of the dosimeter. The significance of this treatment was that it facilitated accurate film dosimetry in the axial plane, for independent verification. Also, it enabled rigorous evaluation of robustness, reproducibility and accuracy of response, at the three dose levels. The OCTOPUS 5x commercial scanner was used for dose readout from the dosimeters at daily time intervals. The use of improved optics and acquisition technique yielded substantially improved noise characteristics (reduced to {approx}2%) than has been achieved previously. Intradosimeter uniformity of radiochromic response was evaluated by calculating a 3D gamma comparison between each dosimeter and axially rotated copies of the same dosimeter. This convenient technique exploits the rotational symmetry of the distribution. All points in the gamma comparison passed a 2% difference, 1 mm distance-to-agreement criteria indicating excellent intradosimeter uniformity even at low dose levels. Postirradiation, the dosimeters were all found to exhibit a slight increase in opaqueness with time. However, the relative dose distribution was found to be extremely stable up to 90 h postirradiation indicating excellent temporal stability. Excellent interdosimeter reproducibility was also observed between the four dosimeters. Gamma comparison maps between each dosimeter and the average distribution of all four dosimeters showed full agreement at the 2% difference, 2 mm distance-to-agreement level. Dose readout from the 3D dosimetry system was found to agree better with independent film measurement than with treatment planning system calculations in penumbral regions and was generally accurate to within 2% dose difference and 2 mm distance-to-agreement. In conclusion, these studies demonstrate excellent precision, accuracy, robustness, and reproducibility of the PRESAGE/optical-CT system for relative 3D dosimetry and support its potential integration with the RPC H and N credentialing phantom for IMRT verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Creating 3D Web-Based Game Environment Using BIM Models for Virtual On-Site Visiting of Building HVAC Systems

A web-based 3D game project was presented in this paper to demonstrate the process of using building information modeling (BIM) to create an interactive 3D on-line `Green' training environment. The system architecture, the implementation process and major components of this virtual training environment were discussed. Existing studies on BIM-based collaborations mainly focused on local-file-sharing approach using proprietary applications. Limited research focused on using BIM as an online gaming platform to create a web browser-based interactive 3D virtual environment for collaboration, learning and/or training. The gap was partially caused by the lack of understanding how to implement a BIM-based game in web browser environment. In this paper, the authors provided an implementation example using a hospital BIM model to create an interactive web-based 3D BIM game environment to allow users to visualize and interact with the BIM components using regular web browsers. The intention of this project is to create a proprietaryindependent training environment to conduct energy re-commissioning trainings for hospital facility management staff. This virtual BIM environment can potentially be customized for engineering student learning and project collaborations as well. The conclusion was that current BIM and game technology are mature enough to allow us to create serious web-based interactive learning/training virtual environment. The successful integration of BIM and web browsers paved the way for many learning and training applications, which need built-environment as context.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Note: An improved 3D imaging system for electron-electron coincidence measurements

We demonstrate an improved imaging system that can achieve highly efficient 3D detection of two electrons in coincidence. The imaging system is based on a fast frame complementary metal-oxide semiconductor camera and a high-speed waveform digitizer. We have shown previously that this detection system is capable of 3D detection of ions and electrons with good temporal and spatial resolution. Here, we show that with a new timing analysis algorithm, this system can achieve an unprecedented dead-time (<0.7 ns) and dead-space (<1 mm) when detecting two electrons. A true zero dead-time detection is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 08: A Low-Cost Optical Scanner and Gantry for use with 3D Printing of Radiation Therapy Accessories

Purpose: Three-dimensional printing has been implemented at our institution to create customized treatment accessories including shielding and bolus. In order to effectively use 3D printing, the topography of the patient must first be acquired. To this end, we have evaluated a low-cost structured-light 3D scanner in order to assess the clinical viability of this technology. Methods: For ease of use, the scanner (3D Systems, Sense 3D Scanner) was mounted in a simple gantry that guided its motion and maintained an optimum distance between the scanner and the object. To characterise the spatial accuracy of the scanner, we used a geometric phantom and an anthropomorphic head phantom. The geometric phantom was machined from plastic and had overall dimensions of 24 cm by 15 cm and included a hemispherical and a tetrahedron protrusion roughly the dimensions of an average forehead and nose respectively. Meshes acquired by the optical scanner were compared to meshes generated from high-resolution CT images. Results: Scans were acquired in under one minute. Most of the optical scans contained noticeable artefacts although in most instances these were considered minor. Using an algorithm that calculated distances between the two meshes, we found most of the optical scanner measurements agreed with those from CT to within about 1 mm for the geometric phantom and to within about 2 mm for the head phantom. Conclusion: In summary, we deemed this scanner to be clinically acceptable and it has been used to design treatment accessories for several skin cancer patients.

60 APPLIED LIFE SCIENCES↗

Valved nozzle with a compensator and massively parallel 3D printing system

In one aspect, the present disclosure provides a nozzle for a 3D printing system. The nozzle may include a flowpath with a material inlet and a material outlet. The nozzle may further include a valve in fluid communication with the flowpath between the material inlet and the material outlet, where the valve includes a closed state and an open state, where in the closed state the valve obstructs the flowpath between the material inlet and the material outlet, and where in the open state the material inlet is in fluid communication with the material outlet. The nozzle may further include a compensator in fluid communication with the flowpath, where the compensator includes a contracted state associated with the open state of the valve and an expanded state associated with the closed state of the valve.

Lewis, Jennifer A.↗

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

Enhancing the ATR Primary Coolant System: A 3D Modeling Approach

The project consisted in system inspections to the ATR Primary Coolant System involving welds, fittings, motors, pumps, flanges, and heat exchangers to enhance Inservice Inspection program as required by DOE orders. NOTE: This article is to be published as "DOE & DOE Contractors Only" in the OPEXShare application, which means it will be available for viewing to DOE & DOE Contractor registered users only. This article can also be used by CAES for their training and safety meetings.

42 - ENGINEERING↗

Controllable 3D Manufacturing System

Next generation Small Modular Reactor (SMR) requires new and improved techniques, instrumentations and strategies to deal with the anticipated high radiation and high temperature environment (esp. in reactors). Component manufacturing technologies will be required that take full advantage of the new 3-D printing methods employed by additive manufacturing technologies. These manufacturing methods must be capable of producing components or sub components on a limited production basis and with nuclear quality. Based on our success in developing a variety of award-winning high energy and high power ultrafast fiber lasers and our pioneered work in fs laser 3D manufacturing (US patents, 9643361 and 9770760), PolarOnyx proposes to use tunable fiber lasers to develop smart AM & SM system to make nuclear quality components for SMR. In Phase I, we have achieved critical milestones and experimentally demonstrated the most critical functions of the proposed controllable laser AM: • Developed and investigated a series of NDI sensing technologies. Combination of IR thermal image and high resolution visible camera provides a powerful tool to characterize thermal distribution and defects. • Built an in-line laser induced breakdown spectroscopy (LIBS) to real time detect compositions of powder and parts, and melting temperature of the melting pool. It proves the LIBS is a very powerful tool to precisely guide the process. • Filed a patent (Application number 16378485) for integrating IR and visible images and LIBS for intelligent AM system. • Developed control algorithm and proved it works well for overhang experiment. • Achieved high density (>99%) and excellent mechanical properties. • Succeeded in developing a working and reliable calibration method to extract true temperature distribution during AM process. • Demonstrated spatial and temporal pulse shaping methods, and impact on microstructures. • Filed one utility patent • Laid out a solid path for phase II to work on controllable 3D manufacturing system development and optimization and to make components with nuclear quality. Our proprietary fs fiber laser based AM processing offers an ultimate solution for manufacturing high temperature components with high strength for nuclear systems. The 3D AM system in conjunction with the intelligent sensing and control is energy efficient and cost effective for the growing nuclear industries. Successful development of the proposed AM technology will provide a vital tool to solve existing and potential issues. This technology will be directly applied in the 3D printing area with combined market share of $10(s) of billions. The achievement in this research will have significant and wide social, scientific, and economic impacts by providing affordable low cost intelligent AM/SM systems, laser micromachining systems, improving energy efficiency, and reducing fabrication and operational cost. Having demonstrated the proof of concept in Phase I, we will prototype the controllable AM/SM system and investigate the efficiency and qualification of fabricating various nuclear quality components in Phase II.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-J-164: An Investigation of a Low-Cost ‘dry’ Optical-CT Scanning System for 3D Dosimetry

Purpose: To characterize and explore the efficacy of a novel low-cost, lowfluid, broad-beam optical-CT system for 3D-dosimetry in radiochromic Presage dosimeters. Leading current optical-CT systems incorporate expensive glass-based telecentric lens technology, and a fluid bath with substantial amounts of fluid (which introduces an inconvenience factor) to minimize refraction artifacts. Here we introduce a novel system which addresses both these limitations by: (1) the use of Fresnel lenses in a telecentric arrangement, and (2) a ‘solid’ fluid bath which dramatically reduces the amount of fluid required for refractive-index (RI) matching. Materials Methods: A fresnel based telecentric optical-CT system was constructed which expands light from a single red LED source into a nominally parallel beam into which a cubic ‘dry-tank’ is placed. The drytank consists of a solid polyurethane cube (with the same RI as Presage) but containing a cylindrical cavity (11.5cm diameter × 11cm ) into which the dosimeter is placed for imaging. A narrow (1-3mm) gap between the walls of the dosimeter and dry-tank is filled with a fluid of similar RI. This arrangement reduces the amount of RI fluid from about 1000cc to 75cc, yielding substantial practical benefit in convenience and cost. The new system was evaluated in direct comparison against Eclipse planning system from a 4-field parallel-opposed treatmen Results: Gamma calculations of dose from DFOS-dry system versus Eclipse showed 92% and 97% agreement with 4mm/4% and 5mm/5% criteria, respectively, in the central 80% of dose distribution. Reconstructions showed some edge artifacts, as well as some dose underestimation towards the dosimeter edge. Conclusion: The implementation of Fresnel based ‘dry’ optical-CT for 3Ddosimetry would represent an important advance enhancing costeffectiveness and practical viability. The performance of the prototype presented here is not yet comparable to the state-of-the-art, but shows sufficient promise for further investigation to elevate image quality to match gold-standard optical-CT systems. This work was supported by NIH R01CA100835.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

07 ISOTOPE AND RADIATION SOURCES↗

Wide Area 3D Measurement System for Analysis of 3013 Inner Container Closure Weld Region

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR, a laser confocal microscope (LCM) is used to perform close visual examination of the surface and to measure corrosion features on the surface. However, in FY20, the introduction of the Wide Area 3D Measurement System (WAMS) was tested as a method for faster inspection of the ICCWR. Optimization of the WAMS parameters for data collection was carried out using a generic tear-drop type sample containing large and fine Stress Corrosion Cracking (SCC) fractures and high resolution images were compared to the image obtained with the LCM. Although the image with the LCM shows higher resolution than the WAMS images, the small features can be still identified in the WAMS images. The advantage of collecting data for the full circumference using the WAMS is that it can take about a week to complete, which represents 1/16 of the time needed with the LCM. Nonetheless, both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS can be utilized to obtain images for faster screening or identification of corrosion features on the surface while the LCM can be utilized to obtain higher resolution images of those areas identified by the WAMS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Billion-atom synchronous parallel kinetic Monte Carlo simulations of critical 3D Ising systems

An extension of the synchronous parallel kinetic Monte Carlo (spkMC) algorithm developed by Martinez et al. [J. Comp. Phys. 227 (2008) 3804] to discrete lattices is presented. The method solves the master equation synchronously by recourse to null events that keep all processors' time clocks current in a global sense. Boundary conflicts are resolved by adopting a chessboard decomposition into non-interacting sublattices. We find that the bias introduced by the spatial correlations attendant to the sublattice decomposition is within the standard deviation of serial calculations, which confirms the statistical validity of our algorithm. We have analyzed the parallel efficiency of spkMC and find that it scales consistently with problem size and sublattice partition. We apply the method to the calculation of scale-dependent critical exponents in billion-atom 3D Ising systems, with very good agreement with state-of-the-art multispin simulations.

97 MATHEMATICS AND COMPUTING↗

3013 Inner Container Closure Weld Region (ICCWR) Characterization by Wide Area 3D Measurement System (WAMS) Analysis (FY21 Progress Report)

As part of the 3013 Surveillance Program, through-wall penetration from stress corrosion cracking (SCC) of the 3013 inner containers has been identified as the most credible condition for failure withing the 50- years lifetime. Chlorides contained in Pu-bearing material, together with intra-canister humidity levels, metallurgical conditions, and internal stresses have been found to produce corrosion in the Inner Container Closure Weld Region (ICCWR) of the 3013 canister system. A Laser Confocal Microscope (LCM) is used as part of the 3013 Surveillance Program protocol to identify the prevalence of corrosion and corrosionrelated cracking in the ICCWR2. With the LCM, a close visual examination is made of the ICCWR surface along with measurements of corrosion-related features. LCM inspections produce immense amounts of image data that is time intensive to analyze. There is also a 9-year backlog of images, with approximately 49 canisters that must be evaluated. To expedite data analysis and reduce the amount of generated data, a Wide Area 3D Measurement System (WAMS) microscope has been added to the examination protocol. Although WAMS is a lower resolution microscope, small features of interest can be still identified. The advantage of collecting data for the full circumference using the WAMS is that it can take about 1/16 of the time needed with the LCM. Both systems offer capabilities that combined can be utilized to expedite the examination of the ICCWR. The WAMS is an efficient system for screening and identification of corrosion features while the LCM can be utilized to obtain higher resolution images areas identified by the WAMS. This report explains and justifies the data collection methods used with the WAMS. It includes a summary of the data generated by WAMS in FY21. The goals set for data collection in FY21 were met. A total of twenty-two DE’s were imaged, and analysis was carried out on eleven samples. The analyzed samples showed large numbers of potential cracks and pits distributed throughout the surfaces. Lastly, to explain the advantages of the WAMS, its capabilities were compared to those of a simpler microscope. Micrographs of the samples imaged in FY21 and those analyzed are included in the appendices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fragility of ferromagnetic double exchange interactions and pressure tuning of magnetism in 3 d - 5 d double perovskite Sr 2 FeOsO 6

The ability to tune exchange (magnetic) interactions between 3d transition metals in perovskite structures has proven to be a powerful route to discovery of novel properties. Here we demonstrate that the introduction of 3d-5d exchange pathways in double perovskites enables additional tunability, a result of the large spatial extent of 5d wave functions. Using x-ray probes of magnetism and structure at high pressure, we show that compression of Sr2FeOsO6 drives an unexpected continuous change in the sign of Fe-Os exchange interactions and a transition from antiferromagnetic to ferrimagnetic order. We analyze the relevant electron-electron interactions, shedding light into fundamental differences with the more thoroughly studied 3d-3d systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗