Search NASA⌕ Search

SEARCH · Search NASA

Results for “500 kV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An SF 6 gas-insulated −500 kV DC conical insulator vacuum feedthrough

A test electrode was biased to −500 kV direct current (DC) by means of a novel SF 6 gas-insulated conical alumina insulator feedthrough. The design enables the extreme high vacuum conditions required by spin-polarized electron sources by reducing the photogun vacuum chamber volume compared to coaxial cylindrical insulators. In contrast to conventional inverted-insulator photogun designs that rely on solid dielectric interfaces for high-voltage terminations, the present design employs a pressurized SF 6 intervening volume between a conical alumina insulator and a modified commercial epoxy high-voltage cable receptacle. Here, this approach enables the use of commercially available cable hardware while extending the demonstrated operating voltage of solid feedthroughs. A maximum voltage of −500 kV was applied to a test electrode attached to the narrow end of the feedthrough inside a chamber filled with SF 6 at 170.3 kPa (10 psig) and later under vacuum to −259 kV, limited by field emission. The results demonstrate that a commercial high-voltage cable combined with a custom-designed SF 6 gas-insulated vacuum feedthrough can be used to bias photogun electrodes to −500 kV DC.

Palacios-Serrano, Gabriel [Thomas Jefferson Nation↗

Use of TCSR with Split Windings for Shortening the Spar Cycle Time in 500 kV Lines

The arc-fault recharge phenomenon in single-phase automatic reclosure (SPAR) of a line is examined. Abrief description is given of the design of a 500 kV thyristor controlled shunt reactor (TCSR) with split valve-side windings. This type of TCSR is shown to effectively quench a single-phase arc fault in a power transmission line and shortens the SPAR cycle time.

42 ENGINEERING↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV dc to a future polarized beam photogun, to be designed for operating at 350kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

TCSR Features Facilitating Safe Testing of 500 kV Power Transmission Lines

Reasons are examined for failures of gas-insulated circuit breakers on lines with shunt reactors that provide a level of line compensation close to 100%. It is shown that using a TCSR as a linear reactor makes it possible to eliminate the reason leading to failure of the circuit breaker in line testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas, ↗

Inner surface flash-over of insulator of low-inductance high-voltage self-breakdown gas switch and its application

In this paper, the inner surface flash-over of high-voltage self-breakdown switch, which is used as a main switch of pulse modulator, is analyzed in theory by employing the method of distributed element equivalent circuit. Moreover, the field distortion of the switch is simulated by using software. The results of theoretical analysis and simulation by software show that the inner surface flash-over usually starts at the junction points among the stainless steel, insulator, and insulation gas in the switch. A switch with improved structure is designed and fabricated according to the theoretical analysis and simulation results. Several methods to avoid inner surface flash-over are used to improve the structure of switch. In experiment, the inductance of the switch is no more than 100 nH, the working voltage of the switch is about 600 kV, and the output voltage and current of the accelerator is about 500 kV and 50 kA, respectively. And the zero-to-peak rise time of output voltage at matched load is less than 30 ns due to the small inductance of switch. The original switch was broken-down after dozens of experiments, and the improved switch has been worked more than 200 times stably.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a compact generator for gigawatt, nanosecond high-voltage pulses

A compact generator producing 2.2-ns 1.5 GW high-voltage pulses was developed. The generator employed a 27.6 Ω, 0.9 ns pulse-forming-line (PFL), which was charged by an iron core transformer with a turn ratio of 2:33.5 and a coefficient of 0.94. A 1.2 μF, 20 kV capacitor and a hydrogen thyratron were used in the primary circuit. When the thyratron closed at 14.5 kV, 3.4% of the energy stored in the capacitor was delivered to the PFL in 850 ns, producing a peak voltage of up to ∼500 kV. In addition, the principle of triple resonance transformation was employed by adding a 50 pF tuning capacitor and a 1.15 mH inductor between the transformer and the PFL, which led to a significant reduction of the duration and peak value of the transformer voltage without reducing that in the PFL. Meanwhile, an adjustable self-break oil switch was applied. By using transmission lines with impedance overmatched to that of the PFL, the generator delivered a 512 kV pulse across an electron beam diode, generating radiation with a dose of 20 mR/pulse at 20 cm ahead of the diode. The generator provides an excellent ultra-short radiation pulse source for the studies on radiation physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a high-power, high-gain, 2nd harmonic, 22.848 GHz gyroklystron

In this paper we consider the design of a four-cavity, high-gain K-band gyroklystron experiment for high gradient structure testing. The frequency doubling gyroklystron utilizes a beam voltage of 500 kV and a beam current of 200 A from a magnetron injection gun (MIG) originally designed for a lower-frequency device. The microwave circuit features input and gain cavities in the circular TE{sub 011} mode and penultimate and output cavities that operate at the second harmonic in the TE{sub 021} mode. We investigate the MIG performance and study the behavior of the circuit for different values of perpendicular to parallel velocity ratio (α= V{sub ⊥}/ V{sub z}). This microwave tube is expected to be able to produce at least 20 MW of power in 1μs pulses at a repetition rate of at least 120 Hz. A maximum efficiency of 26% and a large signal gain of 58 dB under zero-drive stable conditions were simulated for a velocity ratio equal to 1.35.

43 PARTICLE ACCELERATORS↗

Design, conditioning, and performance of a high voltage, high brightness dc photoelectron gun with variable gap

A new high voltage photoemission gun has been constructed at Cornell University which features a segmented insulator and a movable anode, allowing the cathode-anode gap to be adjusted. In this work, we describe the gun's overall mechanical and high voltage design, the surface preparation of components, as well as the clean construction methods. We present high voltage conditioning data using a 50 mm cathode-anode gap, in which the conditioning voltage exceeds 500 kV, as well as at smaller gaps. Finally, we present simulated emittance results obtained from a genetic optimization scheme using voltage values based on the conditioning data. These results indicate that for charges up to 100 pC, a 30 mm gap at 400 kV has equal or smaller 100% emittance than a 50 mm gap at 450 kV, and also a smaller core emittance, when placed as the source for the Cornell energy recovery linac photoinjector with bunch length constrained to be <3 ps rms. For 100 pC up to 0.5 nC charges, the 50 mm gap has larger core emittance than the 30 mm gap, but conversely smaller 100% emittance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high efficiency Ku-band radial line relativistic klystron amplifier

To achieve the gigawatt-level microwave amplification output at Ku-band, a radial-line relativistic klystron amplifier is proposed and investigated in this paper. Different from the annular electron beam in conventional axial relativistic klystron amplifiers, a radial-radiated electron beam is employed in this proposed klystron. Owing to its radially spreading speciality, the electron density and space charge effect are markedly weakened during the propagation in the radial line drift tube. Additionally, the power capacity, especially in the output cavity, is enhanced significantly because of its large volume, which is profitable for the long pulse operation. Particle-in-cell simulation results demonstrate that a high power microwave with the power of 3 GW and the frequency of 14.25 GHz is generated with a 500 kV, 12 kA electron beam excitation and the 30 kW radio-frequency signal injection. The power conversion efficiency is 50%, and the gain is about 50 dB. Meanwhile, there is insignificant electron beam self-excitation in the proposed structure by the adoption of two transverse electromagnetic reflectors. The relative phase difference between the injected signals and output microwaves keeps stable after the amplifier saturates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Terahertz-Driven Local Dipolar Correlation in a Quantum Paraelectric

Light-induced ferroelectricity in quantum paraelectrics is a new avenue of achieving dynamic stabilization of hidden orders in quantum materials. In this Letter, we explore the possibility of driving a transient ferroelectric phase in the quantum paraelectric KTaO 3 via intense terahertz excitation of the soft mode. We observe a long-lived relaxation in the terahertz-driven second harmonic generation (SHG) signal that lasts up to 20 ps at 10 K, which may be attributed to light-induced ferroelectricity. Through analyzing the terahertz-induced coherent soft-mode oscillation and finding its hardening with fluence well described by a single-well potential, we demonstrate that intense terahertz pulses up to 500 kV=cm cannot drive a global ferroelectric phase in KTaO 3 . Instead, we find the unusual long-lived relaxation of the SHG signal comes from a terahertz-driven moderate dipolar correlation between the defect-induced local polar structures. We discuss the impact of our findings on current investigations of the terahertz-induced ferroelectric phase in quantum paraelectrics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of the Pacific DC Intertie Wide Area Damping Controller

This study describes the design and implementation of a proof-of-concept Pacific DC Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV DCtransmission line in the WI. The control system utilizes real-time phasor measurement unit feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.

24 POWER TRANSMISSION AND DISTRIBUTION↗