Search NASA⌕ Search

SEARCH · Search NASA

Results for “5f”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

On the 3d6 4s2 (5D) - 3d7 4s1 (5F) separation in Fe

Full CI calculations are used to calibrate SDSI treatment of the 5D-5F separation in the Fe atom. The (5s4p2d), (5s4p3d), and (5s4p2d1f) basis sets were used for the FCI calculations. The importance of the 3s and 3p correlation and the relativistic effects are studied at SDCI level. The role of polarization functions in computing atomic separations in transition metal atoms is discussed. It is observed that the FCI separation is slightly smaller than the SDCI results, and the SDCI data yield an adequate description of the 5D-5F separation with only 8 electrons correlated. It is concluded that the differential effect of higher excitations becomes more important when the 3s and 3p electrons are correlated.

Bauschlicher, Charles W., Jr.↗

Northrop F-5F shark nose development

During spin susceptibility testing of the Northrop F-5F airplane, two erect spin entries were obtained from purely longitudinal control inputs at low speed. Post flight analysis of the data showed that the initial yaw departure occurred at zero sideslip, and review of wind tunnel data showed significant yawing moments present at angles of attack well above stall. Further analysis of this wind tunnel data indicated that the yawing moments were being generated by the long slender nose of the airplane. Redesign of the nose was accomplished, resulting in a nose configuration which completely alleviated the asymmetric yawing moments.

Edwards, O. R.↗

F-5F Shark Nose radome lightning test

A unique F-5F radome wtih a geometry similar to a Shark Nose profile was tested with a high voltage Marx generator, 1,200,000 volts in order to demonstrate the effectiveness of the lightning protection system with currents from 5,000 amperes or greater. An edge discontinuity configuration is a characteristic feature in the forward region of the radome and occasionally serves as an attachment point. The results of nineteen attachment tests at various aspect angles with an air gap of one meter indicated that no damage occurred to the dielectric material of the radom. The test proved the effectiveness of the lightning protection system.

Scott, G. W.↗

On the 3d2 4s2, 3d3 4s1, and 3d4 states of Ti

The energies of the 3F (3d2 4s2), 5F (3d3 4s1) and 5D (3d4) states of Ti are investigated on the basis of MCSCF and CI calculations. Following SCF calculations using a basis set including the primitive set of Wachters (1970) and the diffuse d function of Hay (1977), four full-electron CI calculations involving the 3d and 4s electrons were performed to obtain the natural orbitals, and the full CI calculations were repeated. MCSCF calculations then performed using the most important configurations of the natural orbital basis are found to be in agreement with those of Dunning (1980), but to differ from CI results. CI(SD) calculations including single and double excitations from the MCSCF reference are found to be in agreement with the full CI but differ from experimental energy separations. Further calculations reveal that Dunning's MCSCF description is an oversimplication of the problem, and that the 5F-5D separation at the CI(SD) level is in good agreement with experiment for all basis sets but the 3F state is too low relative to the 5F and 5D states.

Bauschlicher, C. W., Jr.↗

TiCl, TiH and TiH+ Bond Energies, a Test of a Correlation Consistent Ti Basis Set

Correlation consistent basis sets are developed for Ti atom. The polarization functions are optimized for the average of the 3F and 5F states. One series of correlation consistent basis sets is for 3d and 4s correlation, while the second series includes 3s and 3p correlation as well as 3d and 4s correlation. These basis sets are tested using the Ti 3F-5F separation and the dissociation energies of TiCl X4Phi, TiH X4Phi, and TiH(+) X3Phi. The CCSD(T) complete basis set limit values are determined by extrapolation. The Douglas Kroll approach is used to compute the scalar relativistic effect. Spin-orbit effects are taken from experiment and/or computed at the CASSCF level. The Ti 3F-5F separation is in excellent agreement with experiment, while the TiCl, TiH, and TiH(+) bond energies are in good agreement with experiment. Extrapolation with the valence basis set is consistent with other atoms, while including 3s and 3p correlation appears to make extrapolation.

Bauschlicher, Charles W., Jr.↗

Recent results of the Goddard rocket program for observing stars.

Rockets flown by A. M. Smith have yielded spectra of Alpha Vir, Bl V, Zeta Puppis, O 5f, Zeta Ori, O9.5 Ib, Zeta Oph, O9.5 V and Zeta Per, Bl Ib, at about 0.5 A resolution. Many weak subordinate lines are visible in the range 924 to 1700 A as well as strong resonance lines, some of which have P Cygni profiles. Sharp interstellar lines from C I, C II, O I and Si II are seen. Stecher and Smith have confirmed the presence of CO in the interstellar medium from lines in the ultraviolet spectra of Zeta Oph and Zeta Per. Absolute energy calibrations of the ultraviolet energy distribution of Alpha Leo, Alpha CMa, Gamma Ori and Kappa Ori have been derived with accuracy to about plus or minus 15% over the range 1350-3100 A from rocket spectra at 10 A resolution obtained by D. C. Evans.

Underhill, A. B.↗

Research for preparation of cation-conducting solids by high-pressure synthesis and other methods

It was shown that two body-centered-cubic skeleton structures, the Im3 KSbO3 phase and the defect-pyrochlore phase A(+)B2X6, do exhibit fast Na(+)-ion transport. The placement of anions at the tunnel intersection sites does not impede Na(+)-ion transport in (NaSb)3)(1/6 NaF), and may not in (Na(1+2x)Ta2 5F)(Ox). The activation energies are higher than those found in beta-alumina. There are two possible explanations for the higher activation energy: breathing of the bottleneck (site face or edge) through which the A(+) ions must pass on jumping from one site to another may be easier in a layer structure and/or A(+)-O bonding may be stronger in the cubic structures because the O(2-) ion bonds with two (instead of three) cations of the skeleton. If the former explanation is dominant, a lower activation energy may be achieved by optimizing the lattice parameter. If the latter is dominant, a new structural principle may have to be explored.

Goodenough, J. B.↗

Transition probabilities and Stark-broadening parameters of neutral and singly ionized lead

Strengths and Stark widths of the prominent visible PbI and PbII lines are measured in emission by means of a gas-driven shock tube. Absolute ionic line strengths for 7s-7p and 7p-7d arrays conform well to quantum-mechanical sum rules and agree with theoretical predictions, but 6d-5f results differ markedly from central-field approximations. Neutral-line strengths agree satisfactorily with available comparison data. Semiempirical theory predicts the widths of PbII lines with characteristic reliability of better than 25%.

Miller, M. H.↗

Full configuration interaction benchmark calculations for TiH

Full configuration interaction (FCI) results for the 3F and 5F states of Ti and the 4Phi and 2Delta states of TiH are presented. While the coupled pair functional (CPF) or modified CPF approaches are found to work well for the 4Phi state of TiH, they do not perform as well for the 2Delta state. Although for mu, the CASSCF/MRCI methods do well for the 2Delta state, when the active space is expanded outside the normal valence definition, the dipole moment is only brought into agreement with the FCI results by natural orbital iterations.

Bauschlicher, Charles W., Jr.↗

An ab initio study of Fe(CO)n, n = 1,5, and Cr(CO)6

Ab initio calculations have been performed for Cr(CO)6 and Fe(CO)n, n = 1,5. Basis sets of better than double zeta quality are used, and correlation is included using the modified coupler-pair functional method. The computed geometries and force constants are in reasonable agreement with experiment. The sequential bond dissociation energies of CO from Fe(CO)5 are estimated to be: 39, 31, 25, 22, and greater than 5 kcal/mol. It is noted that the first bond dissociation energy is relative to the singlet ground state of Fe(CO)5 and the lowest singlet state of Fe(CO)4, whereas the second is relative to the ground triplet states of Fe(CO)4 and Fe(CO)3. In addition, the binding energy for Fe-CO would be modified to 18 kcal/mol if dissociation occurred to the Fe(5F) excited state asymptote. The CO binding energies for Fe and Cr are found to be in poorer agreement with experiment than those found in a previous study on Ni(CO)4. The origins of this difference are discussed.

Barnes, Leslie A.↗

Effects of afternoon "siesta" naps on sleep, alertness, performance, and circadian rhythms in the elderly

STUDY OBJECTIVES: To determine the effects of a 90-minute afternoon nap regimen on nocturnal sleep, circadian rhythms, and evening alertness and performance levels in the healthy elderly. DESIGN AND SETTING: Nine healthy elderly subjects (4m, 5f, age range 74y-87y) each experienced both nap and no-nap conditions in two studies each lasting 17 days (14 at home, 3 in the laboratory). In the nap condition a 90-minute nap was enforced between 13:30 and 15:00 every day, in the no-nap condition daytime napping was prohibited, and activity encouraged in the 13:30-15:00 interval. The order of the two conditions was counterbalanced. PARTICIPANTS: N/A INTERVENTIONS: N/A MEASUREMENTS: Diary measures, pencil and paper alertness tests, and wrist actigraphy were used at home. In the 72 hour laboratory studies, these measures were augmented by polysomnographic sleep recording, continuous rectal temperature measurement, a daily evening single trial of a Multiple Sleep Latency Test (MSLT), and computerized tests of mood, activation and performance efficiency. RESULTS: By the second week in the "at home" study, an average of 58 minutes of sleep was reported per siesta nap; in the laboratory, polysomnography confirmed an average of 57 minutes of sleep per nap. When nap and no-nap conditions were compared, mixed effects on nocturnal sleep were observed. Diary measures indicated no significant difference in nocturnal sleep duration, but a significant increase (of 38 mins.) in 24-hour Total Sleep Time (TST) when nocturnal sleeps and naps were added together (p<0.025). The laboratory study revealed a decrease of 2.4% in nocturnal sleep efficiency in the nap condition (p<0.025), a reduction of nocturnal Total Sleep Time (TST) by 48 mins. in the nap condition (p<0.001) which resulted primarily from significantly earlier waketimes (p<0.005), but no reliable effects on Wake After Sleep Onset (WASO), delta sleep measures, or percent stages 1 & 2. Unlike the diary study, the laboratory study yielded no overall increase in 24-hour TST consequent upon the siesta nap regimen. The only measure of evening alertness or performance to show an improvement was sleep latency in a single-trial evening MSLT (nap: 15.6 mins., no nap: 11.5 mins., p<0.005). No significant change in circadian rhythm parameters was observed. CONCLUSIONS: Healthy seniors were able to adopt a napping regimen involving a 90-minute siesta nap each day between 13:30 and 15:00, achieving about one hour of actual sleep per nap. There were some negative consequences for nocturnal sleep in terms of reduced sleep efficiency and earlier waketimes, but also some positive consequences for objective evening performance and (in the diary study) 24-hour sleep totals. Subjective alertness measures and performance measures showed no reliable effects and circadian phase parameters appeared unchanged.

Non-NASA Center↗

Gender Differences in Baroreflex Sensitivity after Bed Rest

Two potential contributing factors to post-spaceflight orthostatic intolerance are decreases in baroreflex sensitivity (BRS) and sympathetic nervous system response. The purpose of this study was to examine the shape of the BRS curve and sympathetic response to a wide range of blood pressures (BP) before and during 6 head-down bed rest (BR). METHODS: Normal volunteers were tested one day before BR (20M, 1 0F) and near BR days 30 (20M, 10F), 60 (16M, 8F), and 90 (1 0M, 5F). BP was pharmacologically manipulated by 10-min infusions of phenylephrine (PE) and sodium nitroprusside (SNP) at 3 increasing concentrations with a 20-min rest between PE and SNP. Electrocardiogram and continuous finger blood pressure were recorded. A blood sample was drawn at the end of each infusion to measure plasma norepinephrine levels. The spontaneous baroreflex slope (SBS), a measure of BRS, was calculated as the slope of a sequence of 3 or more beats in which the systolic BP (SBP) and following R-R interval (RR) both increased or decreased. The data included saturated responses at the upper but not the lower end of the BP range. Mean response curves were constructed using second-order mixed model analysis. Results are based on term significance in the models. RESULTS RR: RR was lower during BR than pre BR (p<0.001). Pre BR males were modeled by a linear RR response to SBP (p=0.000) while females had a quadratic response which saturated at high SBP (p=0.019). By day 30, both genders were modeled by a linear response; compared to males, females had an attenuated (lower slope) RR response to changes in SBP (p=0.031). SBS: SBS vs SBP analysis showed a lower SBS during BR (p<0.001) when compared to pre BR. Females had a higher SBS than males pre BR (p=0.006). Females exhibited saturating SBS at higher SBP (p=0.016) on day 30, while males were modeled by a linear SBS response to SBP (p=0.035). NE: Females had different NE response to diastolic BP than males pre BR (p=0.035) and on day 30 (p=0.005). CONCLUSION: NE, RR and SBS responses to BP are affected by gender and BR. Not only do gender and BR baseline differences exist, but gender and BR also influence the slope and saturation of the BRS curves. Attenuated and saturating RR and SBS responses, as well as differences in baseline values, may contribute to the higher rates of orthostatic intolerance in women and after bed rest.

Arzeno, Natalia M.↗

Low-Dose Caffeine Administration During Acute Sleep Deprivation Eliminates Visual Motion Processing Impairment, but Does Not Improve Saccadic Rate

Oculomotor tracking performance changes according to time awake. A constant routine (CR) study demonstrated that increasing time awake 1) reduces the precision of visual motion processing, 2) decreases steady-state closed-loop pursuit performance and 3) decreases peak saccadic velocity. We aimed to determine the contribution of homeostatic sleep pressure on these oculometric changes by administering low-dose caffeine over one night of sleep deprivation. Participants completed two weeks of at-home 8.5 hours sleep per day, followed by an approximately 24-hour laboratory CR in semi-recumbent posture under less than 4 lux of light. The visual tracking task was performed every two hours after waking and hourly overnight. Low-dose caffeine of 0.3 milligrams per kilogram was administered hourly during the biological night. Nine participants (5F) completed the study. Caffeine dosing: 1) prevented the impairment of visual motion processing, 2) reduced by approximately half the impairment of closed-loop pursuit performance (gain, minus 0.47 percent per hour, significance of slope change: p (probability) less than 0.006; proportion smooth, minus 0.35 percent per hour, p less than 0.005), and 3) had an insignificant (p less than 0.39) effect on the impairment of saccadic peak velocity (slope, minus 1.13 percent per hour; intercept, minus 0.62 percent per hour). These results suggest that visual motion processing and some proportion of closed-loop pursuit performance are impaired due to homeostatic mechanisms during sleep deprivation.

Sleep↗

Shockwave/Boundary-Layer Interaction Studies Performed in the NASA Langley 20-Inch Mach 6 Air Tunnel

This paper highlights results from a collaborative study performed by The University of Tennessee Space Institute (UTSI) and NASA Langley Research Center on the Shockwave/Boundary-Layer Interaction (SWBLI) generated by a cylindrical protuberance on a flat plate in a Mach 6 flow. The study was performed in the 20-Inch Mach 6 Air Tunnel at NASA Langley Research Center and consisted of two separate entries. In the first entry, simultaneous high-speed schlieren and high-speed pressure-sensitive paint (PSP) imaging – which was performed for the first time in the 20-Inch Mach 6 facility at NASA Langley – were performed as well as simultaneous high-speed schlieren and oil-flow imaging. In the second entry, the model configuration was modified to increase the size of the interaction region. High-speed schlieren and infrared thermography (IR) surface imaging were performed in this second entry. The goal of these tests was to characterize the SBLI in the presence of a laminar, transitional, and turbulent boundary layer using high-speed optical imaging techniques. AoA = sting angle-of-attack (°) dcylinder = cylinder diameter (mm) dtrip = cylindrical tripping element diameter (mm) Δshock = shock stand-off distance (mm) hcylinder = cylinder height (mm) htrip = cylindrical tripping element height (mm) HSS = high-speed schlieren M∞ = freestream Mach number PSP = pressure-sensitive paint Re∞ = freestream unit Reynolds number (m-1) SWBLI = shockwave/boundary-layer interaction θplate = model plate angle (°) Introduction his paper highlights two experimental entries performed in the 20-Inch Mach 6 Air Blowdown Tunnel at NASA Langley Research Center in collaboration with The University of Tennessee Space Institute (UTSI). The purpose of these entries was to characterize the dynamic shockwave/boundary-layer interaction (SWBLI) between a vertical cylinder on a flat plate and laminar, transitional (XSWBLI), and turbulent (SWTBLI) boundary layers with a freestream Mach number of 6 using non-intrusive optical diagnostics. Experiments performed by Murphree et al.1,2 were among the first to specifically characterize XSWBLI induced by a vertical cylinder on a flat plate geometry using several optical measurement techniques. Recent optical studies of XSWBLI phenomenon have been performed by UTSI at Mach 2 in their low-enthalpy blow wind tunnel3-8 and by Texas A&M University and UTSI at Mach numbers of 6 and 7 in their Adjustable Contour Expansion wind tunnel.9 The experiments described in this paper were intended to complement previous studies by expanding the freestream unit Reynolds number range, Re∞, over which the XSWBLI phenomena has been observed. Additionally these experiments, made possible under NASA’s new facility funding model under the Aeronautics Evaluation and Test Capabilities (AETC) project, promoted collaboration between university and NASA researchers. The initial entry in the 20-Inch Mach 6 Air Tunnel at NASA Langley occurred in December of 2016. Originally, testing was to occur in November of 2016 in the 31-Inch Mach 10 Air Tunnel at NASA Langley. This facility was chosen so that the XSWBLI phenomenon could be observed at much higher Mach numbers than had previously been attempted in ground test experiments. The model selected for this experiment, a 10° half-angle wedge with a sharp leading edge (described in detail in section II.B), had previously been used by Danehy et al. [10] for boundary layer transition studies using the nitric oxide planar laser-induced fluorescence (NO PLIF) flow visualization technique. In that work, it was determined that transition could be induced downstream of a single htrip = 1-mm tall, dtrip = 4-mm diameter cylindrical tripping element and that the streamwise location of the transition could be changed for a single Re∞ by changing the model angle-of-attack (AoA) (see Fig. A3 in Ref. [10] for more details). Based on the findings of that work, a decision was made to use the wedge model with the cylindrical tripping element to trip the boundary layer flow ahead of a cylindrical protuberance in order to achieve a XSWBLI. Unfortunately, the 31-Inch Mach 10 facility had been taken offline for repairs in October of 2016 and a decision was made to move the test to the 20-Inch Mach 6 facility. Since the behavior of the boundary layer with the chosen model configuration had not been studied before in that facility and the available test time was limited, the entry was considered to be exploratory and was used to collect spatially-resolved and time-resolved flow and surface visualization data that would be used to inform a second entry. Test techniques included simultaneous high-speed schlieren (HSS) captured at 160 kHz and high-speed pressure sensitive paint captured at 10 kHz as well as oil flow visualization, captured at 750 Hz. The second entry in the 20-Inch Mach 6 facility occurred in June and July of 2017. In this follow-on test, modifications to the wind tunnel model were made based on observations made during the first entry and included removing the cylindrical tripping element, increasing the size of the cylinder used to induce the SWBLI to increase the size of the interaction while simultaneously improving spatial resolution, and using a swept ramp array, similar to that described in Ref. [11], to trip the flow to turbulence. Simultaneous HSS (captured at 140 kHz, 100 kHz, and 40 kHz) and conventional IR thermography (captured at 30 Hz) imaging were performed simultaneously in this follow-on entry. This paper is intended to serve as a summary of the work performed during these two entries, to detail lessons learned from each entry, and to highlight some of the datasets acquired. Details on the experimental setup, model configuration, and techniques used are provided. Papers providing a more rigorous analysis of data acquired during the second entry, including statistical, spectral, and modal decomposition methods, can be found in Refs. [12,13]. An entry examining XSWBLI in the 31-Inch Mach 10 Blowdown Wind Tunnel facility is currently planned for mid-to-late calendar year 2019, pending the success of facility repairs. The work performed and described in this paper and the upcoming entry in the 31-Inch Mach 10 facility at NASA Langley have been made possible by NASA’s new facility funding model under the Aeronautics Evaluation and Test Capabilities (AETC) project. Wind Tunnel Facility All experiments discussed in this paper were performed in the 20-Inch Mach 6 Air Tunnel at NASA Langley Research Center. Specific details pertaining to this facility can be found in Refs. [14,15], with only a brief description of the facility provided here. For both entries, the nominal freestream unit Reynolds number was varied between 1.8×106 m-1 (0.5×106 ft-1) and 26.3×106 m-1 (8×106 ft-1). The nominal stagnation pressure was varied between 0.21 MPa and 3.33 MPa and the nominal stagnation temperature was varied between 480 K and 520 K to achieve the desired Re∞ condition. For all runs, the nominal freestream Mach number was 6. The nearly square test section is 520.7-mm (20.5-inches) wide by 508-mm (20-inches) high. Two 431.8-mm (17-inch) diameter windows made of Corning 7940, Grade 5F schlieren-quality glass serve as the side walls of the tunnel and provide optical access for the high-speed schlieren measurements. A rectangular window made of the same material as the side windows served as the top wall of the test section and provided optical access for the high-speed PSP and oil flow measurements. For the second entry, this top window was replaced with a Zinc Selenide (ZnSe) window with an anti-reflection coating capable of passing IR wavelengths between 8μm and 12μm with greater than 98% transmittance. The model was sting supported by a strut attached to a hydraulic system that allows for the model pitch angle to be adjusted between -5° to +55°. For the first entry, an initial pitch/pause sweep of the model AoA was performed to observe the resulting SWBLI. Ultimately, however, the sting pitch angle for this entry was fixed at +10.0° so that the angle of the top surface of the wedge relative to the streamwise axis of the tunnel (referred to herein as the plate angle, θplate), was θplate = 0°. For the second entry, θplate = 0° and θplate = -13.25° were initially tested with the swept ramp array (discussed in the following section) to determine which orientation produced conditions most favorable for XSWBLI to occur based on the heating signatures observed over the top surface of the model in the IR thermography images. Based on these initial tests, θplate = -13.25° was set for the remainder of the runs in the second entry. For both entries, any model changes were performed in a housing located beneath the closed test section. Prior to performing a run of the tunnel, the housing was sealed and the tunnel started. Once the appropriate freestream conditions were achieved, the model was injected into the test section using a hydraulic injection system. B. Model Geometry For all runs, a 10° half-angle (20° full-angle) wedge model with a sharp leading edge was used. The model is described in detail in Refs. [10,16]. The top surface of the sharp leading edge of the model extended 47.8 mm from its upstream-most edge to a junction with the upstream edge of a stainless steel top plate that then extended an (a) (c) (b) Fig. 1 (a) Schematic of top surface of wedge model with gas seeding insert, (b) perspective view of the model in the 20-Inch Mach 6 tunnel with centerline pressure orifices on sharp leading edge, and (c) a perspective view of the model with stainless steel (top) and SLA middle insert (bottom) during the first entry. Flow occurs from left to right.

Bathel, Brett F.↗