Search NASA⌕ Search

SEARCH · Search NASA

Results for “787”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-E-T-787: Utility of the Two Candidate 192-Ir and 169-Yb HDR Sources for Use with a Novel Direction Modulated Brachytherapy Tandem Applicator for Cervical Cancer Treatment

Purpose: A novel tungsten alloy shielded, MRI-compatible, direction modulated brachytherapy (DMBT) concept tandem applicator, which enables unprecedented intensity modulation, was used to evaluate treatment plan quality improvement over a conventional tandem. The utility of the 192-Ir and 169-Yb HDR sources, for use with the DMBT applicator, was evaluated. Methods: The total diameter of the DMBT tandem applicator is 6.0 mm, which consists of 5.4-mm diameter tungsten alloy and 0.3 mm thick plastic sheath. The tandem has 6 symmetric peripheral 1.3-mm diameter grooves for the source to travel. MCNPX v.2.6 was used to simulate the 192-Ir and 169-Yb sources inside the DMBT applicator. First, TG-43 source parameters were evaluated. Second, 3D dose matrix with 1 mm3 resolution were imported into an in-house-coded inverse optimization treatment planning program to obtain optimal plans for 19 clinical cases. All plans were compared with the standard tandem and ring plans. Prescription dose was 15.0 Gy. All plans were normalized to receive the same HRCTV D90. Results: Generally, the DMBT tandem (and ring) plans were better than the conventional tandem and ring plans for 192-Ir and 169-Yb HDR sources. The mean data of D2cc for bladder, rectum, and sigmoid were 11.65±2.30 Gy, 7.47±3.05 Gy, and 9.84±2.48 Gy for Ir-192 DMBT tandem, respectively. These data for Yb-169 were 11.67±2.26 Gy, 7.44±3.02 Gy, and 9.83±2.38 Gy, respectively. The HR-CTV D98 and V100 were 16.37±1.86 Gy and 97.37 ± 1.92 Gy for Ir-192 DMBT, respectively. The corresponding values for Yb-169 were 16.43±1.86 Gy, and 97.51 ± 1.91 Gy. Plans with the 169-Yb source generally produced more favorable results where V100 increased by 13.65% while D2cc across all OARs reduced by 0.54% compared with the 192-Ir plans. Conclusion: For the DMBT tandem applicator, 169-Yb source seems to produce more directional beams resulting in increased intensity modulation capacity, thus resulting in more conformal plans.

60 APPLIED LIFE SCIENCES↗

Eliminating Inconsistencies in Simulation and Treatment Planning Orders in Radiation Therapy

Purpose: To identify deficiencies with simulation and treatment planning orders and to develop corrective measures to improve safety and quality. Methods and Materials: At Washington University, the DMAIIC formalism is used for process management, whereby the process is understood as comprising Define, Measure, Analyze, Improve, Implement, and Control activities. Two complementary tools were used to provide quantitative assessments: failure modes and effects analysis and reported event data. The events were classified by the user according to severity. The event rates (ie, number of events divided by the number of opportunities to generate an event) related to simulation and treatment plan orders were determined. Results: We analyzed event data from the period 2008-2009 to design an intelligent SIMulation and treatment PLanning Electronic (SIMPLE) order system. Before implementation of SIMPLE, event rates of 0.16 (420 of 2558) for a group of physicians that were subsequently used as a pilot group and 0.13 (787 of 6023) for all physicians were obtained. An interdisciplinary group evaluated and decided to replace the Microsoft Word-based form with a Web-based order system. This order system has mandatory fields and context-sensitive logic, an ability to create templates, and enables an automated process for communication of orders through an enterprise management system. After the implementation of the SIMPLE order, the event rate decreased to 0.09 (96 of 1001) for the pilot group and to 0.06 (145 of 2140) for all physicians (P<.0001). The average time to complete the SIMPLE form was 3 minutes, as compared with 7 minutes for the Word-based form. The number of severe events decreased from 10.7% (45 of 420) and 12.1% (96 of 787) to 6.2% (6 of 96) and 10.3% (15 of 145) for the pilot group and all physicians, respectively. Conclusions: There was a dramatic reduction in the total and the number of potentially severe events through use of the SIMPLE system. In addition, the order process has become more efficient and reliable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The molecular gradient using the divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation theory: The DEC-RI-MP2 gradient

We report an implementation of the molecular gradient using the divide-expand-consolidate resolution of the identity second-order Møller-Plesset perturbation theory (DEC-RI-MP2). The new DEC-RI-MP2 gradient method combines the precision control as well as the linear-scaling and massively parallel features of the DEC scheme with efficient evaluations of the gradient contributions using the RI approximation. We further demonstrate that the DEC-RI-MP2 gradient method is capable of calculating molecular gradients for very large molecular systems. A test set of supramolecular complexes containing up to 158 atoms and 1960 contracted basis functions has been employed to demonstrate the general applicability of the DEC-RI-MP2 method and to analyze the errors of the DEC approximation. Moreover, the test set contains molecules of complicated electronic structures and is thus deliberately chosen to stress test the DEC-RI-MP2 gradient implementation. Additionally, as a showcase example the full molecular gradient for insulin (787 atoms and 7604 contracted basis functions) has been evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of Transposable Elements in the Ectomycorrhizal Fungus Laccaria bicolor

Background: The publicly available Laccaria bicolor genome sequence has provided a considerable genomic resource allowing systematic identification of transposable elements (TEs) in this symbiotic ectomycorrhizal fungus. Using a TEspecific annotation pipeline we have characterized and analyzed TEs in the L. bicolor S238N-H82 genome. Methodology/Principal Findings: TEs occupy 24% of the 60 Mb L. bicolor genome and represent 25,787 full-length and partial copy elements distributed within 171 families. The most abundant elements were the Copia-like. TEs are not randomly distributed across the genome, but are tightly nested or clustered. The majority of TEs exhibits signs of ancient transposition except some intact copies of terminal inverted repeats (TIRS), long terminal repeats (LTRs) and a large retrotransposon derivative (LARD) element. There were three main periods of TE expansion in L. bicolor: the first from 57 to 10 Mya, the second from 5 to 1 Mya and the most recent from 0.5 Mya ago until now. LTR retrotransposons are closely related to retrotransposons found in another basidiomycete, Coprinopsis cinerea. Conclusions: This analysis 1) represents an initial characterization of TEs in the L. bicolor genome, 2) contributes to improve genome annotation and a greater understanding of the role TEs played in genome organization and evolution and 3) provides a valuable resource for future research on the genome evolution within the Laccaria genus.

Labbe, Jessy L↗

Simplified Aid for Extra-Vehicular Activity Rescue (SAFER) Battery Assessment

In 2013, the Boeing Company model 787-8 Dreamliner commercial aircraft experienced three catastrophic lithium (Li) battery failures. The cause of each failure resulted in a single-cell thermal runaway (TR) condition, which propagated to adjacent battery cells. Two of the failures involved rechargeable lithium-ion (Li-Ion) batteries, and the third event involved a nonrechargeable lithium-manganese dioxide (Li-MnO2) battery. In response to these Li battery failures, the NASA Engineering and Safety Center (NESC) approved a technical assessment of the International Space Station Simplified Aid for Extra-Vehicular Activity Rescue (SAFER) Li non-rechargeable battery. This assessment was conducted to evaluate the SAFER Li nonrechargeable battery safety design features against Boeing 787 Dreamliner Li battery failure lessons learned. Specifically, this investigation focused on assessing the severity of a SAFER battery TR hazard conditions.

Iannello, Christopher J.↗

Propulsion Airframe Aeroacoustics and Aircraft System Noise Flight Research Test: NASA Overview

Motivations and the formulation of the objectives are described for an ambitious flight research test conducted in collaboration between NASA and The Boeing Company. The Propulsion Airframe Aeroacoustics and Aircraft System Noise Flight Research Test was executed by the Boeing ecoDemonstrator Program with an Etihad Airways Boeing 787-10 aircraft. Five key technical approaches are described that were used to accomplish the more unconventional and challenging objectives of the research. In addition to the modern technology of the 787, these include evaluating multiple acoustic shielding and reflection effects using both the wing and fuselage in straight flight and banking flight paths, hardwalling the aft duct liner, and utilizing an extensive instrumentation array both on the ground and on the aircraft. The research level version of NASA’s aircraft system noise prediction capability including a new acoustic scattering method were used to confirm the technical approaches and provide guidance for the detailed design of instrumentation and flight test plans. Initial comparisons are shown of flight test data to predictions using the research level of NASA’s Aircraft Noise Prediction Program. Significant prediction challenges are revealed when compared to these high-quality data, while major progress is shown both in the measurement and the prediction of propulsion airframe aeroacoustic effects in flight. This comparison marks the first rigorous validation with modern flight test data and establishes a basis to further understand and quantify the state of NASA’s current capability and to develop improvements in the fidelity of aircraft system noise predictions. The context of multiple coordinated companion research papers is described as well as future plans for the continued analysis of this flight research data.

Propulsion Airframe Aeroacoustics↗

Atomistic Conversion Reaction Mechanism of WO 3 in Secondary Ion Batteries of Li, Na, and Ca

Abstract Intercalation and conversion are two fundamental chemical processes for battery materials in response to ion insertion. The interplay between these two chemical processes has never been directly seen and understood at atomic scale. Here, using in situ HRTEM, we captured the atomistic conversion reaction processes during Li, Na, Ca insertion into a WO 3 single crystal model electrode. An intercalation step prior to conversion is explicitly revealed at atomic scale for the first time for Li, Na, Ca. Nanoscale diffraction and ab initio molecular dynamic simulations revealed that after intercalation, the inserted ion–oxygen bond formation destabilizes the transition‐metal framework which gradually shrinks, distorts and finally collapses to an amorphous W and M x O (M=Li, Na, Ca) composite structure. This study provides a full atomistic picture of the transition from intercalation to conversion, which is of essential importance for both secondary ion batteries and electrochromic devices.

He, Yang↗

Proteogenomic strategies for identification of aberrant cancer peptides using large-scale Next Generation Sequencing data

Cancer is driven by the acquisition of somatic DNA lesions. Distinguishing the early driver mutations from subsequent passenger mutations is key to molecular sub-typing of cancers, and the discovery of novel biomarkers. The availability of genomics technologies (mainly wholegenome and exome sequencing, and transcript sampling via RNA-seq, collectively referred to as NGS) have fueled recent studies on somatic mutation discovery. However, the vision is challenged by the complexity, redundancy, and errors in genomic data, and the difficulty of investigating the proteome using only genomic approaches. Recently, combination of proteomic and genomic technologies are increasingly employed. However, the complexity and redundancy of NGS data remains a challenge for proteogenomics, and various trade-offs must be made to allow for the searches to take place. This paperprovides a discussion of two such trade-offs, relating to large database search, and FDR calculations, and their implication to cancer proteogenomics. Moreover, it extends and develops the idea of a unified genomic variant database that can be searched by any mass spectrometry sample. A total of 879 BAM files downloaded from TCGA repository were used to create a 4.34 GB unified FASTA database which contained 2,787,062 novel splice junctions, 38,464 deletions, 1105 insertions, and 182,302 substitutions. Proteomic data from a single ovarian carcinoma sample (439,858 spectra) was searched against the database. By applying the most conservative FDR measure, we have identified 524 novel peptides and 65,578 known peptides at 1% FDR threshold. The novel peptides include interesting examples of doubly mutated peptides, frame-shifts, and non-sample-recruited mutations, which emphasize the strength of our approach.

59 BASIC BIOLOGICAL SCIENCES↗

Pollution and Risk of PAHs in Surface Sediments from the Tributaries and Their Relation to Anthropogenic Activities, in the Main Urban Districts of Chongqing City, Southwest China

Concentrations, sources and risk of 16 priority polycyclic aromatic hydrocarbons (PAHs) were investigated in surface sediments from 19 representative tributaries in a regional scale of Chongqing City. The total concentration of 16 PAHs (ΣPAHs) ranged from 221 to 3205 ng g{sup −1} with a mean of 1055 ng g{sup −1}. Most tributaries of the Jialing River exhibited significantly higher ΣPAHs concentrations (mean 1864 ng g{sup −1}) compared to those flowing into the Yangtze River (mean 787 ng g{sup −1}). Isomeric ratio and hierarchical clustering analysis showed combustion may impact sedimentary PAHs at most center sites of the City, while PAHs at most sites were mixed of petrogenic and pyrogenic sources. Toxicity equivalency concentration for carcinogenic PAH were 2–4 times more than the Dutch limit. More comprehensive assessment of safety is suggested to reduce environmental risk of PAHs in sediments.

54 ENVIRONMENTAL SCIENCES↗

Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of 0.1 wt.% Co on the Hot Deformation and Toughness of Fine-Grained Low-Carbon Steel at Sub-zero Temperatures

The effect of 0.1 wt.% Co on the hot deformation behavior of fine-grained low-carbon microalloyed steel was investigated at temperatures of 850-1200 °C and a strain rate of 5 s{sup −1}. Furthermore, the toughness of the steel with and without Co at sub-zero temperatures was evaluated. The results suggest that the addition of 0.1 wt.% Co increases the flow stress and delays the occurrence of dynamic recrystallization (DRX) at the same deformation temperature and strain. The DRX fraction of steel specimens without and with 0.1 wt.% Co was about 67.4 and 43.9% at 850 °C, respectively. Then, it increased to 100% at 1100 °C. Compared with steel without Co, cementite particles in the tempered sorbite of steel with 0.1 wt.% Co decreased in size but increased in quantity, yield strength increased from 756 to 787 MPa, and Charpy V-notch energy at − 20 and − 50 °C improved from 69 and 41 to 102 and 65 J, respectively. The fracture morphology and crack propagation characteristics were consistent with the variation in impact energy.

36 MATERIALS SCIENCE↗

Unexpectedly Severe Acute Radiotherapy Side Effects Are Associated With Single Nucleotide Polymorphisms of the Melanocortin-1 Receptor

Purpose: The melanocortin-1 receptor (MC1R) regulates melanin biogenesis. Deoxyribonucleic acid sequence variants in the form of single nucleotide polymorphisms (SNPs) of MC1R affect melanin expression and are linked to skin phenotype. We aimed to determine whether SNPs of MC1R were associated with unexpectedly severe ionizing radiation reactions. Methods and Materials: The MC1R genotype of a cohort of Australians with unexpectedly severe acute and/or late reactions (Common Terminology Criteria Version 3 (CTCv3) Grade 3 or 4) to radiotherapy (RT) for cancer (n = 30) was analyzed. The findings were compared with control data from our previous study of MC1R representative of the general Australian population (n = 1,787). Results: The difference in frequency of alleles encoding a 'red hair color' phenotype in the cohort of patients with unexpectedly severe acute radiation reactions (n = 12) was significantly increased compared with the control population (p = 0.003). Acute radiosensitivity was especially associated with the R160W variant allele (odds ratio, 3.64 [95% confidence interval, 1.3-10.27]). The corresponding comparison of MC1R controls with unexpectedly severe late radiation reactions (n = 18) was not significant. It was also found that R160W as a part of the genotype in the patients with unexpectedly severe acute RT side effects as compared with the control group was also significant (p = 0.043). Conclusions: In this small cohort of cancer patients, deoxyribonucleic acid sequence variants of the MC1R gene, especially the R160W variant, have been associated with unexpectedly severe acute reactions to RT. This result needs to be verified in a larger cohort of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Study of Prostate Intrafraction Motion During External Beam Radiotherapy With Daily Endorectal Balloon

Purpose: To prospectively investigate intrafraction prostate motion during radiofrequency-guided prostate radiotherapy with implanted electromagnetic transponders when daily endorectal balloon (ERB) is used. Methods and Materials: Intrafraction prostate motion from 24 patients in 787 treatment sessions was evaluated based on three-dimensional (3D), lateral, cranial-caudal (CC), and anterior-posterior (AP) displacements. The mean percentage of time with 3D, lateral, CC, and AP prostate displacements >2, 3, 4, 5, 6, 7, 8, 9, and 10 mm in 1 minute intervals was calculated for up to 6 minutes of treatment time. Correlation between the mean percentage time with 3D prostate displacement >3 mm vs. treatment week was investigated. Results: The percentage of time with 3D prostate movement >2, 3, and 4 mm increased with elapsed treatment time (p < 0.05). Prostate movement >5 mm was independent of elapsed treatment time (p = 0.11). The overall mean time with prostate excursions >3 mm was 5%. Directional analysis showed negligible lateral prostate motion; AP and CC motion were comparable. The fraction of time with 3D prostate movement >3 mm did not depend on treatment week of (p > 0.05) over a 4-minute mean treatment time. Conclusions: Daily endorectal balloon consistently stabilizes the prostate, preventing clinically significant displacement (>5 mm). A 3-mm internal margin may sufficiently account for 95% of intrafraction prostate movement for up to 6 minutes of treatment time. Directional analysis suggests that the lateral internal margin could be further reduced to 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subclassification of Recursive Partitioning Analysis Class II Patients With Brain Metastases Treated Radiosurgically

Purpose: Although the recursive partitioning analysis (RPA) class is generally used for predicting survival periods of patients with brain metastases (METs), the majority of such patients are Class II and clinical factors vary quite widely within this category. This prompted us to divide RPA Class II patients into three subclasses. Methods and Materials: This was a two-institution, institutional review board-approved, retrospective cohort study using two databases: the Mito series (2,000 consecutive patients, comprising 787 women and 1,213 men; mean age, 65 years [range, 19-96 years]) and the Chiba series (1,753 patients, comprising 673 female and 1,080 male patients; mean age, 65 years [range, 7-94 years]). Both patient series underwent Gamma Knife radiosurgery alone, without whole-brain radiotherapy, for brain METs during the same 10-year period, July 1998 through June 2008. The Cox proportional hazard model with a step-wise selection procedure was used for multivariate analysis. Results: In the Mito series, four factors were identified as favoring longer survival: Karnofsky Performance Status (90% to 100% vs. 70% to 80%), tumor numbers (solitary vs. multiple), primary tumor status (controlled vs. not controlled), and non-brain METs (no vs. yes). This new index is the sum of scores (0 and 1) of these four factors: RPA Class II-a, score of 0 or 1; RPA Class II-b, score of 2; and RPA Class II-c, score of 3 or 4. Next, using the Chiba series, we tested whether our index is valid for a different patient group. This new system showed highly statistically significant differences among subclasses in both the Mito series and the Chiba series (p < 0.001 for all subclasses). In addition, this new index was confirmed to be applicable to Class II patients with four major primary tumor sites, that is, lung, breast, alimentary tract, and urogenital organs. Conclusions: Our new grading system should be considered when designing future clinical trials involving brain MET patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic, magnetic, and structural properties of CrMnSb 0.5 Si 0.5

Half-metallic Heusler compounds are among the most actively studied materials for applications in spin-based devices. Largely, this is due to their higher Curie temperature compared with the other half-metallic compounds, and relative ease of fabrication. Here we theoretically study one such Heusler alloy CrMnSb 0.5 Si 0.5 . In particular, we demonstrate a potential stability of this compound by estimating its formation energy, its half-metallic electronic structure (stable under a considered range of biaxial strain), and ferrimagnetic alignment. The calculated Curie temperature of this material is 787 K, much higher than room temperature. At the same time, we have shown that in thin-film geometry the spin-polarization of this material is strongly reduced due to the emergence of surface states in the minority-spin energy gap. In addition, one of the considered termination surfaces is thermodynamically unstable, while the other is stable. Here, the presented results may be useful for researchers working on practical applications in the field of spintronics.

36 MATERIALS SCIENCE↗

Investigation of thermal aging effects on the tensile properties of Alloy 617 by in-situ synchrotron wide-angle X-ray scattering

The nickel-base Alloy 617 has been considered as the lead candidate structural material for the intermediate heat exchanger (IHX) of the Very-High-Temperature Reactor (VHTR). In order to assess the long-term performance of Alloy 617, thermal aging experiments up to 10,000 h in duration were performed at 1000 degrees C. Subsequently, in-situ synchrotron wide-angle X-ray scattering (WAXS) tensile tests were carried out at ambient temperature. M23C6 carbides were identified as the primary precipitates, while a smaller amount of M6C was also observed. The aging effects were quantified in several aspects: (1) macroscopic tensile properties, (2) volume fraction of the M23C6 Phase, (3) the lattice strain evolution of both the matrix and the M23C6 precipitates, and (4) the dislocation density evolution during plastic deformation. The property-microstructure relationship is described with a focus on the evolution of the M23C6 phase. For aging up to 3000 h, the yield strength (YS) and ultimate tensile strength (UTS) showed little variation, with average values being 454 MPa and 787 MPa, respectively. At 10,000 h, the YS and UTS reduced to 380 MPa and 720 MPa, respectively. The reduction in YS and UTS is mainly due to the coarsening of the M23C6 Precipitates. After long term aging, the volume fraction of the M23C6 phase reached a plateau and its maximum internal stress was reduced, implying that under large internal stresses the carbides were more susceptible to fracture or decohesion from the matrix. Finally, the calculated dislocation densities were in good agreement with transmission electron microscopy (TEM) measurements. The square roots of the dislocation densities and the true stresses displayed typical linear behavior and no significant change was observed in the alloys in different aging conditions.

Alloy 617↗