EFFECTS OF MOISTURE IN THE 9975 SHIPPING PACKAGE FIBERBOARD ASSEMBLY

The fiberboard assembly used in 9975 shipping packages as an impact-absorption and insulation component has the capacity to absorb moisture, with an accompanying change to its properties. While package fabrication requirements generally maintain the fiberboard moisture content within manufacturing range, there is the potential during use or storage for atypical handling or storage practices which result in the absorption of additional moisture. In addition to performing a transportation function, the 9975 shipping packages are used as a facility storage system for special nuclear materials at the Savannah River Site. A small number of packages after extended storage have been found to contain elevated moisture levels. Typically, this condition is accompanied by an axial compaction of the bottom fiberboard layers, and the growth of mold. In addition to potential atypical practices, fiberboard can exchange moisture with the surrounding air, depending on the ambient humidity. Laboratory data have been generated to correlate the equilibrium moisture content of cane fiberboard with the humidity of the surrounding air. These data are compared to measurements taken within shipping packages. With a reasonable measurement of the fiberboard moisture content, an estimate of the fiberboard properties can be made. Over time, elevated moisture levels will negatively impact performance properties, and promote fiberboard mold growth and resultant degradation.

42 ENGINEERING↗

EXAMINATION OF SHIPPING PACKAGE 9975-05050

Shipping package 9975-05050 was examined in K-Area following its identification as a high wattage package. Elevated temperature and fiberboard moisture content are key parameters that impact the degradation rate of fiberboard within 9975 packages in a storage environment. The high wattage of this package contributes significantly to component temperatures. After examination in K-Area, the package was provided to SRNL for further examination of the fiberboard assembly. The moisture content of the fiberboard was relatively low (compared to packages examined previously), but the moisture gradient (between fiberboard ID and OD surfaces) was relatively high, as would be expected for the high heat load. The cane fiberboard appeared intact and displayed no apparent change in integrity relative to a new package.

42 ENGINEERING↗

EXAMINATION OF SHIPPING PACKAGE 9975-2130

Shipping package 9975-02130 was examined in K-Area following the identification of a nonconforming condition; the axial gap between the drum flange and upper fiberboard assembly exceeded the maximum allowed value of 1 inch. The average measured axial gap was 1.1 inches. The fiberboard assembly in this package contained moisture levels of {approx}14-24% wood moisture equivalent ({approx}12-19 wt%) This is moderately higher than typically seen in conforming packages, but not as high as seen on most packages which have exceeded the allowed axial gap. Small patches of mold were growing on portions of the lower fiber assembly, but the fiberboard appeared intact and with little apparent change in its integrity. The lead shield had a heavy layer of corrosion product, some of which flaked off easily. The thickness of several flakes was measured, and varied from 0.0016 to 0.0031 inch. However, additional corrosion product remained on the shield under the flaked regions, so the total thickness of corrosion product exceeds 0.0031 inch.

09 BIOMASS FUELS↗

Examination of Shipping Packages 9975-02694 and 9975-02729

SRNL has assisted in the examination of two 9975 shipping packages (9975-02694 and 9975-02729) following their use for storage of nuclear material in K-Area Complex (KAC). Both of these were targeted for examination because they were exposed to water from a leaking expansion joint during storage. When first opened in KAC, the axial gap was found to be in excess of the 1 inch maximum criterion, signaling the potential for degradation of the fiberboard overpack and drum. Within each package the highest fiberboard moisture levels were observed in the bottom layers, but no mold was observed in either package. The fiberboard in each package appeared to retain good integrity consistent with non-degraded material. Minor corrosion was also observed on these drums along the lower stitch welds and on several closure bolts.

42 ENGINEERING↗

Examination of shipping packages 9975-01658, 9975-02075 and 9975-02738

SRNL has assisted in the examination of three 9975 shipping packages (9975-01658, 9975-02075 and 9975-02738) following their use for storage of nuclear material in K-Area Complex (KAC). Each of these was targeted for examination because the axial gap exceeded the 1 inch maximum criterion, signaling the potential for degradation of the fiberboard overpack and drum. Each package experienced a degree of compaction of the bottom fiberboard layers, and had elevated moisture levels toward the bottom. A small amount of mold was observed on the lower fiberboard assembly in 9975-02738. However, the majority of the fiberboard in each package appeared to retain good integrity consistent with non-degraded material. Minor corrosion was observed on these drums, but is judged to have not compromised the drum integrity.

42 ENGINEERING↗

Aging Behavior of the Viton® Fluoroelastomer O-Rings in the 9975 Shipping Package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This paper describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior and leak performance. The CSR behavior of O-rings was evaluated at temperatures from 79 °C to 177 °C. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 75 °C). O-rings were also aged in Primary Containment Vessel (PCV) fixtures at temperatures ranging from 79 °C to 232 °C. The fixtures are helium leak tested periodically to determine if they remain leak-tight. The PCV fixture tests demonstrate that the 9975 O-rings will remain leak-tight at temperatures up to 149 °C for 3 years or more, and no leak failures have been observed with up to 8 years aging at 93 °C. Significantly longer periods of leak-tight service are expected at the lower temperatures actually experienced in the storage environment. The predictive model developed from the CSR data conservatively indicates a service life of more than 20 years at the bounding temperature of 75 °C. Although the relationship between CSR behavior and leak-tight performance has not been established for this design, the CSR predictions for this O-ring are conservative relative to leak-tight performance to date.

36 MATERIALS SCIENCE↗

CSR behavior and aging model for the Viton© Fluorelastomer O-rings in the 9975 shipping package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report for Packaging (SARP) requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This report describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both GLT and GLT-S compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior. The CSR behavior of O-rings was evaluated at temperatures from 175 to 400 °F. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 156 °F). The predictive model developed from the CSR data conservatively indicates a service life of approximately 37 years for Viton GLT O-rings at the maximum effective service temperature of 156 °F. The estimated service life for Viton GLT-S O-rings is significantly longer.

36 MATERIALS SCIENCE↗

EXAMINATION OF SHIPPING PACKAGES 9975-02274 AND 9975-04769

Shipping packages 9975-02274 and 9975-04769 were examined in K-Area following the identification of a non-conforming condition; the axial gap between the drum flange and upper fiberboard assembly exceeded the maximum allowed value of 1 inch. The fiberboard in package 9975-02274 had slightly elevated moisture content, up to 19% wood moisture equivalent (WME). Other compliant packages have displayed similar moisture levels locally, but not as consistently throughout the entire fiberboard assembly. Evidence of mold was observed on the lower assembly, although it appeared relatively dormant. Relatively little compaction or physical degradation was observed in this package. Due to the mold, it is recommended that the fiberboard in this package not be re-used. The fiberboard in package 9975-04769 was relatively dry (7-10% WME) and showed no sign of compaction or physical degradation. Variations in the axial gap that have been measured on this package result from variations in the height of the upper and lower fiberboard assemblies, and their relative orientation to each other. The fiberboard in this package is physically sound and considered fit for continued use.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

EXAMINATION OF SHIPPING PACKAGES 9975-01818, 9975-01903 AND 9975-02287

Three 9975 shipping packages were examined to investigate the non-conforming condition of an axial air gap greater than 1 inch. This condition typically indicates the presence of excess moisture in the fiberboard overpack, and may be accompanied by degradation in the fiberboard properties. The package with the largest axial air gap (9975-01818, with an air gap of 1.437 inches) was found to contain significant excess moisture, and the lower fiberboard assembly was covered with mold and was significantly degraded in strength. This condition is very similar to that observed previously in package 9975-01819. Both packages (-1818 and -1819) appear to contain a similar amount of excess moisture, which was previously estimated for 9975-01819 as {approx}2.5 liters. The condition of 9975-01818 was also evidenced by several rust spots along the bottom chime of the drum, although no significant rust was noted on the closure bolts. Packages 9975-01903 and 9975-02287 were also examined. The axial air gap in these two packages was less than in 9975-01818, but still exceeded 1 inch. These two packages contained elevated moisture levels, although not significantly higher than seen in other 'typical' packages. The fiberboard in these two packages was of sound integrity, and appeared generally consistent with undegraded material. A few small patches of mold on and near the bottom of the fiberboard in 9975-01903 appeared dormant. No mold was observed on package 9975-02287. The SPA will provide recommendations on possible follow-up activities with these three packages. This might include a demonstration in SRNL of whether removal of the caplugs from similar packages would facilitate removal of excess moisture. Future efforts should also include an assessment of using the 1 inch axial gap criterion as a valid indicator of fiberboard degradation.

42 ENGINEERING↗

EXAMINATION OF SHIPPING PACKAGES 9975-01968, 9975-04353 AND 9975-06870

Three 9975 shipping packages were examined to investigate the non-conforming condition of an axial air gap greater than 1 inch. This condition typically indicates the presence of excess moisture in the fiberboard overpack, and may be accompanied by degradation in the fiberboard properties. In the case of these three packages, no excess moisture was present, and the fiberboard was not visibly degraded. However, the lower fiberboard assembly from 9975-06870 was separated into two pieces. The lead shield from 9975-04353 was heavily corroded, while the shield from 9975-01968 had very little corrosion. In the case of 9975-06870, the shield was covered by a stainless steel sleeve, and the condition of the lead was not observed. No other conditions of concern were observed in these three packages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-02168

The Savannah River Site (SRS) stores packages containing plutonium (Pu) materials in the K-Area Complex (KAC). The Pu materials are packaged per the DOE 3013 Standard and stored within Model 9975 shipping packages in KAC. The KAC facility DSA (Document Safety Analysis) credits the Model 9975 package to perform several safety functions, including criticality prevention, impact resistance, containment, and fire resistance to ensure the plutonium materials remain in a safe configuration during normal and accident conditions. The Model 9975 package is expected to perform its safety function for at least 12 years from initial packaging. The DSA recognizes the degradation potential for the materials of package construction over time in the KAC storage environment and requires an assessment of materials performance to validate the assumptions of the analysis and ultimately predict service life. As part of the comprehensive Model 9975 package surveillance program, destructive examination of package 9975-02028 was performed following field surveillance in accordance with Reference. Field surveillance of the Model 9975 package in KAC included nondestructive examination of the drum, fiberboard, lead shield and containment vessels. Results of the field surveillance are provided in Attachment 1. Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-02168. For those attributes that were also measured during the field surveillance, no significant changes were observed. Two conditions were identified that do not meet inspection criteria. These conditions are subject to additional investigation and disposition by the Surveillance Program Authority. The conditions include: (1) The lead shield was covered with a white corrosion layer, and (2) Fiberboard thermal conductivity in the axial direction exceeded the specified range. The Surveillance Program Authority was notified of these conditions and will document the findings by surveillance report. All other observations and test results met identified criteria, or were collected for information and trending purposes.

42 ENGINEERING↗

Examination of shipping packages 9975-01641, 9975-01692, 9975-03373, 9975-02101 AND 9975-02713

SRNL has assisted in the examination of five 9975 shipping packages following storage of nuclear material in K-Area Complex (KAC). Two packages (9975-01641 and -01692) with water intrusion resulting from a roof leak were selected for detailed examination after internal fiberboard degradation (mold) was observed. 9975-01692 contained regions of saturated fiberboard and significant mold, while the second package was less degraded. A third package (9975-03373) was removed from storage for routine surveillance activities, and set aside for further examination after a musty odor was noted inside. No additional degradation was noted in 9975-03373, but the lower assembly could not be removed from the drum for detailed examination. Two additional packages (9975-02101 and -02713) identified for further examination were among a larger group selected for surveillance as part of a specific focus on high-wattage packages. These two packages displayed several non-conforming conditions, including the following: (1) the axial gap criterion was exceeded, (2) a significant concentration of moisture was found in the bottom fiberboard layers, with active mold in this area, (3) condensation and/or water stains were observed on internal components (drum, lid, air shield), and (4) both drums contained localized corrosion along the bottom lip. It is recommended that a new screening check be implemented for packages that are removed from storage, as well as high wattage packages remaining in storage. An initial survey for corrosion along the drum bottom lip of high wattage packages could identify potential degraded packages for future surveillance focus. In addition, after packages have been removed from storage (and unloaded), the drum bottom lip and underside should be inspected for corrosion. The presence of corrosion could signal the need to remove the lower fiberboard assembly for further inspection of the fiberboard and drum prior to recertification of the package.

42 ENGINEERING↗

Fiberboard Humidity Data for 9975 Shipping Packages

The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humidity and temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts.

36 MATERIALS SCIENCE↗

Fiberboard Humidity Data for 9975 Shipping Packages

The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humidity and temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts.

36 MATERIALS SCIENCE↗

Fiberboard Humidity Data for 9975 Shipping Packages

The 9975 surveillance program is identifying a technical basis to support extending the storage period of 9975 packages in KAC beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Two efforts have been undertaken to better understand the levels and behavior of moisture within the fiberboard assemblies of the 9975 shipping package. In the first effort, an initial survey of humidity and temperature in the upper air space of 26 packages stored in KAC was made. The data collected within this first effort help to illustrate how the upper air space humidity varies with the local ambient temperature and package heat load. In the second effort, direct measurements of two test packages are providing a correlation between humidity and fiberboard moisture levels within the package, and variations in moisture throughout the fiberboard assembly. This effort has examined packages with cane fiberboard and internal heat levels of 5 and 10W to date. Additional testing is expected to include 15 and 19W heat levels, and then repeat the same four heat levels with softwood fiberboard assemblies. This report documents the data collected to date within these two efforts

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of shipping package 9975-02403

SRNL examined shipping package 9975-02403 following storage of nuclear material in K-Area Complex (KAC). As a result of field surveillance activities in KAC, this package was identified to contain several non-conforming and other conditions. Further examination of this package in SRNL confirmed significant moisture and mold in the bottom layers of the lower fiberboard assembly, and identified additional corrosion along the seam weld and on the bottom of the drum. It was recently recommended that checking for corrosion along the bottom edge of the drum be implemented for packages that are removed from storage, as well as high wattage packages remaining in storage. The appearance of such corrosion on 9975-02403 further indicates that such corrosion may provide an indication of significant moisture concentration and related degradation within the package. This condition is more likely to develop in packages with higher internal heat loads.

99 GENERAL AND MISCELLANEOUS↗

Compression Stress-Relaxation and Oxygen Consumption Behavior of 9975 Shipping Package O-rings

The 9975 shipping package is used within the DOE complex for shipping special nuclear materials. The shipping packages are currently approved for up to 20 years storage in K-Area Complex (KAC) and work continues to provide technical basis to extend that period. Several techniques have been used at Savannah River National Laboratory to monitor the aging performance of Viton ® GLT or GLT-S fluoroelastomer O-rings. These experiments all involve accelerated aging of the O-ring samples at elevated temperatures. This report describes efforts to extend the service life estimate of GLT and GLT-S O-rings used in the 9975 shipping package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Aging Behavior of Viton{sup R} O-Ring Seals in the 9975 Shipping Package - 12594

The Savannah River Site (SRS) is storing plutonium (Pu) materials in the K-Area Materials Storage (KAMS) facility. The Pu materials were packaged according to the DOE-STD-3013 standard and shipped to the SRS in Type B 9975 packages. The robust 9975 shipping package was not designed for long-term product storage, but it is a specified part of the storage configuration and the KAMS facility safety basis credits the 9975 design with containment. Within the 9975 package, nested stainless steel containment vessels are closed with dual O-ring seals based on Viton{sup R} GLT or GLT-S fluoro-elastomer. The aging behavior of the O-ring compounds is being studied to provide the facility with advanced notice of nonconformance and to develop life prediction models. A combination of field surveillance, leak testing of surrogate fixtures aged at bounding service temperatures, and accelerated-aging methodologies based on compression stress-relaxation and oxygen consumption analysis is being used to evaluate seal performance. A summary of the surveillance program relative to seal aging behavior is presented. The aging behavior of fluoro-elastomer seals based on Viton{sup R} GLT and GLT-S is being studied to develop life prediction models in support of long-term storage of plutonium materials in the 9975 shipping packages at the Savannah River Site. Field surveillance data in combination with accelerated-aging data suggest a significant lifetime for the seals. Typical storage conditions are not anticipated to challenge the leak-tightness of the seals for many years. Early life prediction models based on compression stress relaxation indicate a seal lifetime of ∼12 years at the maximum service temperature predicted (93 deg. C). Seal lifetimes at lower, more realistic conditions are likely significantly longer. Service life predictions based on CSR data are thus far conservative relative to predictions based on time to leakage failure. Surveillance data on packages examined after 6 years in storage show only minor compression set of the O-rings and no significant degradation. Surveillance and testing will continue as needed to validate and refine life prediction models. (authors)