Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABDOMEN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Efficient Pipeline for Abdomen Segmentation in CT Images

Computed tomography (CT) scans usually include some disadvantages due to the nature of the imaging procedure, and these handicaps prevent accurate abdomen segmentation. Discontinuous abdomen edges, bed section of CT, patient information, closeness between the edges of the abdomen and CT, poor contrast, and a narrow histogram can be regarded as the most important handicaps that occur in abdominal CT scans. Currently, one or more handicaps can arise and prevent technicians obtaining abdomen images through simple segmentation techniques. In other words, CT scans can include the bed section of CT, a patient’s diagnostic information, low-quality abdomen edges, low-level contrast, and narrow histogram, all in one scan. These phenomena constitute a challenge, and an efficient pipeline that is unaffected by handicaps is required. In addition, analysis such as segmentation, feature selection, and classification has meaning for a real-time diagnosis system in cases where the abdomen section is directly used with a specific size. A statistical pipeline is designed in this study that is unaffected by the handicaps mentioned above. Intensity-based approaches, morphological processes, and histogram-based procedures are utilized to design an efficient structure. Performance evaluation is realized in experiments on 58 CT images (16 training, 16 test, and 26 validation) that include the abdomen and one or more disadvantage(s). The first part of the data (16 training images) is used to detect the pipeline’s optimum parameters, while the second and third parts are utilized to evaluate and to confirm the segmentation performance. The segmentation results are presented as the means of six performance metrics. Thus, the proposed method achieves remarkable average rates for training/test/validation of 98.95/99.36/99.57% (jaccard), 99.47/99.67/99.79% (dice), 100/99.91/99.91% (sensitivity), 98.47/99.23/99.85% (specificity), 99.38/99.63/99.87% (classification accuracy), and 98.98/99.45/99.66% (precision). In summary, a statistical pipeline performing the task of abdomen segmentation is achieved that is not affected by the disadvantages, and the most detailed abdomen segmentation study is performed for the use before organ and tumor segmentation, feature extraction, and classification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-P-08: Establishment of Local Diagnostic Reference Levels of Routine Abdomen Exam in Computed Tomography According to Body Weight

Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the local diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.

60 APPLIED LIFE SCIENCES↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulated Online Adaptive Magnetic Resonance–Guided Stereotactic Body Radiation Therapy for the Treatment of Oligometastatic Disease of the Abdomen and Central Thorax: Characterization of Potential Advantages

Purpose: To characterize potential advantages of online-adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (SBRT) to treat oligometastatic disease of the non-liver abdomen and central thorax. Methods and Materials: Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR image guided RT system. The SBRT plans were created on the basis of tumor/organ at risk (OAR) anatomy at initial computed tomography simulation (P{sub I}), and simulated adaptive plans were created on the basis of observed MR image set tumor/OAR “anatomy of the day” (P{sub A}). Each P{sub A} was planned under workflow constraints to simulate online-adaptive RT. Prescribed dose was 50 Gy/5 fractions, with goal coverage of 95% planning target volume (PTV) by 95% of the prescription, subject to hard OAR constraints. The P{sub I} was applied to each MR dataset and compared with P{sub A} to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results: Hard OAR constraints were met for all P{sub Is} based on anatomy from initial computed tomography simulation, and all P{sub As} based on anatomy from each daily MR image set. Application of the P{sub I} to anatomy of the day caused OAR constraint violation in 19 of 30 cases. Adaptive planning increased PTV coverage in 21 of 30 cases, including 14 cases in which hard OAR constraints were violated by the nonadaptive plan. For 9 P{sub A} cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a nonadaptive setting. Conclusions: Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared with nonadaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.

60 APPLIED LIFE SCIENCES↗

Percutaneous drainage and management of fluid collections associated with necrotic or cystic tumors in the abdomen and pelvis

Purpose: The purpose of the study was to evaluate the efficacy and safety of percutaneous drainage for palliation of symptoms and sepsis in patients with cystic or necrotic tumors in the abdomen and pelvis. Materials and methods: This is a single center retrospective study of 36 patients (18 men, mean age = 51.1 years) who underwent percutaneous drainage for management of cystic or necrotic tumors in the non-postoperative setting over an 11-year period. Nineteen patients with intraabdominal fluid collections associated with primary malignancies included: cervical (n = 7), colorectal (n = 3), urothelial (n = 3), and others (n = 6). The 17 patients with fluid collections associated with intraabdominal metastases stemmed from the following primary malignancies: oropharyngeal squamous cell carcinoma (n = 3), colorectal (n = 3), ovarian (n = 2), lung (n = 2), melanoma (n = 2) along with others (n = 5). Indications for percutaneous drainage were as follows: pain (36/36; 100%); fever and/or leukocytosis (34/36; 94%), and mass effect (21/36; 58%). Seven patients underwent additional sclerosis with absolute alcohol. Criteria for drainage success were temporary or definitive relief of symptoms and sepsis control. Results: Successful sepsis control was achieved in all patients with sepsis (34/34; 100%) and 30/36 (83%) patients had improvement in pain. Duration of catheterization ranged from 2 to 90 days (mean = 22 days). There were four cases of fluid re-accumulation and one patient developed catheter tract seeding. Alcohol ablation was successful in two patients (2/7; 29%). Nearly all patients (34/36; 94%) died during the follow-up period. Conclusions: Percutaneous drainage was effective for palliative treatment of symptomatic cystic and necrotic tumors in the majority of patients in this series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-I-03: Preliminary Study of Size-Specific Dose Estimates in Adult Abdomenal CT Examinations in Taiwan

Purpose: This study was to investigate size-specific dose estimates (SSDE) for routine adult abdominal CT examinations in Taiwan. Methods: A national survey was conducted in Taiwan in 2014 to investigate SSDEs for routine adult abdominal CT examinations. The hospitals involved in this study provided CT images of their typical patients. The CT image in the level of the middle liver was selected to record the corresponding tube current, slice mAs or effective mAs. The image was also used to estimate the dimensions of patient as measuring the lengths in the anterior to posterior (AP) and lateral (LAT) directions. The effective diameter was then calculated from AP and LAT, and used to look up conversion factors in the AAPM 204 report. The volume CTDI (CTDIvol) for each CT unit was measured on sites using a 32-cm cylindrical standard dose phantom and a calibrated pencil-type ionization chamber. Individual patient’s SSDEs were then calculated from the corresponding SSDE conversion factor and the CTDIvol. Results: The study cohort included 111 CT units. The ratio of turning on automatic tube current modulation (ATCM) or not is 88:23. Effective diameters are 258.7±25.1 mm (167–366 mm). 99.3% of typical patients selected by each hospital have smaller effective diameter than the 32-cm dosimetry phantom. Adult abdomenal SSDE is 17.5 ± 8.8 mGy (1.9-58 mGy). The SSDE seems to decrease as the effective diameter increases as the ATCM turns off, and independent with the effective diameter as the ATCM turns on. Conclusion: The SSDE for typical patients in Taiwan was investigated. We continue to complete this investigation in 2015 to include more valid data to establish SSDE reference level in Taiwan. This study was financially supported by the Atomic Energy Council in Taiwan.

60 APPLIED LIFE SCIENCES↗

Application of Optical Measurement Techniques During Stages of Pregnancy: Use of Phantom High Speed Cameras for Digital Image Correlation (D.I.C.) During Baby Kicking and Abdomen Movements

Paired images were collected using a projected pattern instead of standard painting of the speckle pattern on her abdomen. High Speed cameras were post triggered after movements felt. Data was collected at 120 fps -limited due to 60hz frequency of projector. To ensure that kicks and movement data was real a background test was conducted with no baby movement (to correct for breathing and body motion).

Gradl, Paul↗

Spontaneous Intramuscular Hematomas of the Abdomen and Pelvis: A New Multilevel Algorithm to Direct Transarterial Embolization and Patient Management

PurposeTo report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH).Materials and MethodsFrom May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized as IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed.ResultsTwo patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III).ConclusionTAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE.Level of Evidence4.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Human adipose-derived mesenchymal stromal cells from face and abdomen undergo replicative senescence and loss of genetic integrity after long-term culture

Body fat depots are heterogeneous concerning their embryonic origin, structure, exposure to environmental stressors, and availability. Thus, investigating adipose-derived mesenchymal stromal cells (ASCs) from different sources is essential to standardization for future therapies. In vitro amplification is also critical because it may predispose cell senescence and mutations, reducing regenerative properties and safety. Here, we evaluated long-term culture of human facial ASCs (fASCs) and abdominal ASCs (aASCs) and showed that both met the criteria for MSCs characterization but presented differences in their immunophenotypic profile, and differentiation and clonogenic potentials. The abdominal tissue yielded more ASCs, and these had higher proliferative potential, but facial cells displayed fewer mitotic errors at higher passages. However, both cell types reduced clonal efficiency over time and entered replicative senescence around P12, as evaluated by progressive morphological alterations, reduced proliferative capacity, and SA-β-galactosidase expression. Loss of genetic integrity was detected by a higher proportion of cells showing nuclear alterations and γ-H2AX expression. Our findings indicate that the source of ASCs can substantially influence their phenotype and therefore should be carefully considered in future cell therapies, avoiding, however, long-term culture to ensure genetic stability.

60 APPLIED LIFE SCIENCES↗

Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study

Purpose: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast-to-noise ratio (CNR). Methods: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m{sup 2} with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64-slice DS-CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. Results: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16–26 kg/m{sup 2}) and for all sizes (16–35 kg/m{sup 2}) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%–107%, 23%–83%, and 6%–12%, respectively. Conclusions: DS single energy CT can be used to reduce CM dose by 44%–53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual-energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source.

60 APPLIED LIFE SCIENCES↗

Extended abdominopelvic MRI versus CT at the time of adnexal mass characterization for assessing radiologic peritoneal cancer index (PCI) prior to cytoreductive surgery

Purpose: To evaluate whether extending the MRI scan to include the abdomen at the time of adnexal mass characterization could replace additional CT for peritoneal cancer index (PCI) assessment. Methods: After institutional review board approval for this prospective study, 36 consecutive females with ovarian and FT malignancies were included. All patients signed an informed consent. Patients underwent preoperative CT (32 patients) and MRI (36 patients). Images were interpreted by 2 independent observers. Surgical data were available in 27 patients. Region-by-region analysis was performed for detection rates of peritoneal carcinomatosis (PC). Inter-observer agreement for each region was evaluated by kappa statistics. Radiologic PCI was calculated by CT and MRI independently and inter-observer agreement for CT and MRI as well as agreement between radiologic and surgical PCI were evaluated by weighted-kappa statistics. Results: On region-by-region analysis, the highest detection rates of PC were noted at the central abdomen and pelvis. Detection rates were higher by MRI than CT, mainly in bowel serosal surface, pelvis, and right upper abdomen regions. Inter-observer agreement of MRI was higher than CT in most regions. The median PCI by CT was 5 and 4 for the first and second observers (range 0–21 for both observers), respectively. The median PCI by MRI was 6 (range 0–23 for both observers). The inter-observer agreement of PCI was excellent by both CT and MRI (k = 0.876 and k = 0.912, respectively). The agreement between CT and surgical PCI was 0.660 and 0.590 for the first and second observers, respectively. The agreement between MRI and surgical PCI was 0.797 and 0.798 for the first and second observers, respectively. Conclusions: Extending MRI scan to include the abdomen at the time of adnexal mass characterization allows accurate estimation of PC, with better results than CT, obviating the need for dedicated CT scan of abdomen and pelvis for imaging of PC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-235: Audiovisual Biofeedback Improves the Correlation Between Internal and External Respiratory Motion

Purpose: External respiratory surrogates are often used to predict internal lung tumor motion for beam gating but the assumption of correlation between external and internal surrogates is not always verified resulting in amplitude mismatch and time shift. To test the hypothesis that audiovisual (AV) biofeedback improves the correlation between internal and external respiratory motion, in order to improve the accuracy of respiratory-gated treatments for lung cancer radiotherapy. Methods: In nine lung cancer patients, 2D coronal and sagittal cine-MR images were acquired across two MRI sessions (pre- and mid-treatment) with (1) free breathing (FB) and (2) AV biofeedback. External anterior-posterior (AP) respiratory motions of (a) chest and (b) abdomen were simultaneously acquired with physiological measurement unit (PMU, 3T Skyra, Siemens Healthcare Erlangen, Germany) and real-time position management (RPM) system (Varian, Palo Alto, USA), respectively. Internal superior-inferior (SI) respiratory motions of (c) lung tumor (i.e. centroid of auto-segmented lung tumor) and (d) diaphragm (i.e. upper liver dome) were measured from individual cine-MR images across 32 dataset. The four respiratory motions were then synchronized with the cine-MR image acquisition time. Correlation coefficients were calculated in the time variation of two nominated respiratory motions: (1) chest-abdomen, (2) abdomen-diaphragm and (3) diaphragm-lung tumor. The three combinations were compared between FB and AV biofeedback. Results: Compared to FB, AV biofeedback improved chest-abdomen correlation by 17% (p=0.005) from 0.75±0.23 to 0.90±0.05 and abdomen-diaphragm correlation by 4% (p=0.058) from 0.91±0.11 to 0.95±0.05. Compared to FB, AV biofeedback improved diaphragm-lung tumor correlation by 12% (p=0.023) from 0.65±0.21 to 0.74±0.16. Conclusions: Our results demonstrated that AV biofeedback significantly improved the correlation of internal and external respiratory motion, thus suggesting the need of AV biofeedback in respiratory-gated treatments.

60 APPLIED LIFE SCIENCES↗

Efficacy of compression of different capacitance beds in the amelioration of orthostatic hypotension

Orthostatic hypotension (OH) is the most disabling and serious manifestation of adrenergic failure, occurring in the autonomic neuropathies, pure autonomic failure (PAF) and multiple system atrophy (MSA). No specific treatment is currently available for most etiologies of OH. A reduction in venous capacity, secondary to some physical counter maneuvers (e.g., squatting or leg crossing), or the use of compressive garments, can ameliorate OH. However, there is little information on the differential efficacy, or the mechanisms of improvement, engendered by compression of specific capacitance beds. We therefore evaluated the efficacy of compression of specific compartments (calves, thighs, low abdomen, calves and thighs, and all compartments combined), using a modified antigravity suit, on the end-points of orthostatic blood pressure, and symptoms of orthostatic intolerance. Fourteen patients (PAF, n = 9; MSA, n = 3; diabetic autonomic neuropathy, n = 2; five males and nine females) with clinical OH were studied. The mean age was 62 years (range 31-78). The mean +/- SEM orthostatic systolic blood pressure when all compartments were compressed was 115.9 +/- 7.4 mmHg, significantly improved (p < 0.001) over the head-up tilt value without compression of 89.6 +/- 7.0 mmHg. The abdomen was the only single compartment whose compression significantly reduced OH (p < 0.005). There was a significant increase of peripheral resistance index (PRI) with compression of abdomen (p < 0.001) or all compartments (p < 0.001); end-diastolic index and cardiac index did not change. We conclude that denervation increases vascular capacity, and that venous compression improves OH by reducing this capacity and increasing PRI. Compression of all compartments is the most efficacious, followed by abdominal compression, whereas leg compression alone was less effective, presumably reflecting the large capacity of the abdomen relative to the legs.

Non-NASA Center↗

The Tribolium homeotic gene Abdominal is homologous to abdominal-A of the Drosophila bithorax complex

The Abdominal gene is a member of the single homeotic complex of the beetle, Tribolium castaneum. An integrated developmental genetic and molecular analysis shows that Abdominal is homologous to the abdominal-A gene of the bithorax complex of Drosophila. abdominal-A mutant embryos display strong homeotic transformations of the anterior abdomen (parasegments 7-9) to PS6, whereas developmental commitments in the posterior abdomen depend primarily on Abdominal-B. In beetle embryos lacking Abdominal function, parasegments throughout the abdomen are transformed to PS6. This observation demonstrates the general functional significance of parasegmental expression among insects and shows that the control of determinative decisions in the posterior abdomen by homeotic selector genes has undergone considerable evolutionary modification.

Non-NASA Center↗

Imaging in the pre-operative staging of ovarian cancer

The main prognostic factor in ovarian cancer is the stage of disease at diagnosis. The staging system in use (FIGO classification, updated in 2014) is based on the surgical-pathological findings. Although surgical staging is the gold standard in ovarian cancer, the initial patient management depends on the imaging-based pre-surgical staging assessment, in order to identify unresectable or difficult to resect disease. Radiologists need to be aware of the strengths of the available imaging modalities, as well as the imaging pitfalls. Clear understanding of pattern of disease spread and review areas are critical for accurate staging and treatment planning. The current standard of care for pre-surgical staging is CT of the thorax, abdomen, and pelvis. This allows a rapid evaluation of disease extent and is fairly accurate in identifying bulky disease but has definite limitations in assessing the extent of small volume disease and in the confirmation of certain sites of disease beyond the abdomen. Functional MRI has been reported to be superior in detecting small peritoneal deposits. PET/CT may be used as a problem-solving tool in some patients where determination remains unclear, particularly in confirmation of advanced stage beyond the abdomen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool

Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-E-11: Novel Matching Module for Respiration-Gated Motion Tumor of Cone-Beam Computed Tomography (CBCT) to 4DCT

Purpose: Four dimensional computed tomography (4DCT) scans reliably record whole respiratory phase and generate internal target volumes (ITV) for radiotherapy planning. However, image guiding with cone-beam computed tomography (CBCT) cannot acquire all or specific respiratory phases. This study was designed to investigate the correlation between average CT and Maximum Intensity Projection (MIP) from 4DCT and CBCT. Methods: Retrospective respiratory gating were performed by GE Discovery CT590 RT. 4DCT and CBCT data from CRIS Dynamic Thorax Phantom with simulated breathing mode were analyzed. The lung tissue equivalent material encompassed 3 cm sphere tissue equivalent material. Simulated breathing cycle period was set as 4 seconds, 5 seconds and 6 seconds for representing variation of patient breathing cycle time, and the sphere material moved toward inferior and superior direction with 1 cm amplitude simulating lung tumor motion during respiration. Results: Under lung window, the volume ratio of CBCT scans to ITVs derived from 10 phases average scans was 1.00 ± 0.02, and 1.03 ± 0.03 for ratio of CBCT scans to MIP scans. Under abdomen window, the ratio of CBCT scans to ITVs derived from 10 phases average scans was 0.39 ± 0.06, and 0.06 ± 0.00 for ratio of CBCT scans to MIP scans. There was a significant difference between lung window Result and abdomen window Result. For reducing image guiding uncertainty, CBCT window was set with width 500 and level-250. The ratio of CBCT scans to ITVs derived from 4 phases average scans with abdomen window was 1.19 ± 0.02, and 1.06 ± 0.01 for ratio of CBCT to MIP scans. Conclusion: CBCT images with suitable window width and level can efficiently reduce image guiding uncertainty for patient with mobile tumor. By our setting, we can match motion tumor to gating tumor location on planning CT more accurately neglecting other motion artifacts during CBCT scans.

60 APPLIED LIFE SCIENCES↗