Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABSORPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Device-scale CFD modeling of gas-liquid multiphase flow and amine absorption for CO2 capture

In this paper we aim to develop a validated device-scale CFD model that can predict quantitatively both hydrodynamics and CO2 capture efficiency for an amine-based solvent absorber column with random Pall ring packing. A Eulerian porous-media approach and a two-fluid model were employed, in which the momentum and mass transfer equations were closed by literature-based empirical closure models. We proposed a hierarchical approach for calibrating the parameters in the closure models to make them accurate for the packed column. Specifically, a parameter for momentum transfer in the closure was first calibrated based on data from a single experiment. With this calibrated parameter, a parameter in the closure for mass transfer was next calibrated under a single operating condition. Last, the closure of the wetting area was calibrated for each gas velocity at three different liquid flow rates. For each calibration, cross validations were pursued using the experimental data under operating conditions different from those used for calibrations. This hierarchical approach can be generally applied to develop validated device-scale CFD models for different absorption columns.

Pan, Wenxiao↗

Two-photon absorption of soft X-ray free electron laser radiation by graphite near the carbon K-absorption edge

We have examined the transmission of soft X-ray pulses from the FERMI free electron laser through carbon films of varying thickness, quantifying nonlinear effects of pulses above and below the carbon K-edge. At typical of soft X-ray free electron laser intensities, pulses exhibit linear absorption at photon energies above and below the K-edge, ~308 and ~260 eV, respectively; whereas two-photon absorption becomes significant slightly below the K-edge, ~284.2 eV. The measured two-photon absorption cross section at 284.18 eV (~6 x 10-48 cm4 s) is 7 orders of magnitude above what is expected from a simple theory based on hydrogen-like atoms - a result of resonance effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cr L-Edge X-ray Absorption Spectroscopy of Cr III (acac) 3 in Solution with Measured and Calculated Absolute Absorption Cross Sections

X-ray absorption spectroscopy at the L-edge of 3d transition metals is widely used for probing the valence electronic structure at the metal site via 2p–3d transitions. Assessing the information contained in L-edge absorption spectra requires systematic comparison of experiment and theory. We investigate the Cr L-edge absorption spectrum of high-spin chromium acetylacetonate Cr III (acac) 3 in solution. Using a transmission flatjet enables determining absolute absorption cross sections and spectra free from X-ray-induced sample damage. We address the challenges of measuring Cr L absorption edges spectrally close to the O K absorption edge of the solvent. We critically assess how experimental absorption cross sections can be used to extract information on the electronic structure of the studied system by comparing our results of this Cr III (3d 3 ) complex to our previous work on L-edge absorption cross sections of Mn III (acac) 3 (3d 4 ) and Mn II (acac) 2 (3d 5 ). Considering our experimental uncertainties, the most insightful experimental observable for this d 3 (Cr III )–d 4 (Mn III )–d 5 (Mn II ) series is the L-edge branching ratio, and we discuss it in comparison to semiempirical multiplet theory and ab initio restricted active space calculations. Finally, we further discuss and analyze trends in integrated absorption cross sections and correlate the spectral shapes with the local electronic structure at the metal sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Examination of the Measurement of Absorption Using the Reverberant Room Method for Highly Absorptive Acoustic Foam

The absorption coefficient for material specimens are needed to quantify the expected acoustic performance of that material in its actual usage and environment. The ASTM C423-09a standard, "Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberant Room Method" is often used to measure the absorption coefficient of material test specimens. This method has its basics in the Sabine formula. Although widely used, the interpretation of these measurements are a topic of interest. For example, in certain cases the measured Sabine absorption coefficients are greater than 1.0 for highly absorptive materials. This is often attributed to the diffraction edge effect phenomenon. An investigative test program to measure the absorption properties of highly absorbent melamine foam has been performed at the Riverbank Acoustical Laboratories. This paper will present and discuss the test results relating to the effect of the test materials' surface area, thickness and edge sealing conditions. A follow-on paper is envisioned that will present and discuss the results relating to the spacing between multiple piece specimens, and the mounting condition of the test specimen.

Absorption↗

Absorption of laser radiation in a H-He plasma. I - Theoretical calculation of the absorption coefficient

The theory for calculating the absorption of laser radiation by hydrogen is outlined for the temperatures and pressures of common laboratory plasmas. Nonhydrogenic corrections for determining the absorption by helium are also included. The coefficients for the absorption of He-Ne laser radiation at the wavelengths of 0.633, 1.15, and 3.39 microns in a H plasma is presented for temperatures in the range from 10,000 to 40,000 K and electron number densities in the range from 10 to the 15th power to 10 to the 18th power per cu cm. The total absorption of a H-He plasma calculated from this theory is compared with the measured absorption. The theoretical composition of the H-He absorption is analyzed with respect to the significant absorption processes, inverse bremsstrahlung, photoionization, resonance excitation, and photodetachment.

Stallcop, J. R.↗

Interstellar Mg II and C IV absorption toward Markarian 205 by NGC 4319 - An 'optically thick' QSO absorption system

We have used the Goddard High-Resolution Spectrograph aboard HST to detect interstellar Mg II and C IV absorption lines toward Mrk 205, a QSO whose sightline passes within 3/h kpc of the foreground galaxy NGC 4319. Absorption is detected from both local Milky Way gas and from NGC 4319, making this the first observation of an isolated, low-redshift galaxy causing an 'optically thick' QSO absorption system. We also observed for the first time Mg II absorption from two local High Velocity Clouds along this same sightline. The data support the premise that metal absorption lines seen at higher redshift in QSO spectra originate in gas associated with intervening galaxies. However, neither the strong absorption by (half) of our own Galaxy, nor the weak absorption by NGC 4319, may be typical of absorbers in general.

Bowen, David V.↗

Absorption of laser radiation in a H-He plasma. II - Experimental measurement of the absorption coefficient

The absorption coefficients of 0.633-, 1.15-, and 3.39-micron laser radiation for a homogeneous H-He plasma have been measured in the temperature range from 12.2 to 21.7 (x 1000 K) and in the electron number density range 0.45 to 6.5 (x 10 to the 17th power per cu cm). Good agreement is found between the experimentally determined total absorption for each of the wavelengths and that calculated from theory. Furthermore, because the 3.39-micron absorption is dominated by inverse bremsstrahlung, while the 0.633-micron absorption is dominated by photoionization and resonance absorption, the experiment indicates a correct assessment by the theory of these individual absorption mechanisms.

Billman, K. W.↗

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra is described. The fluorescent intensity If is linearly proportional to the absorption coefficient μ. For studies of surface structures around an element (κ) the fluorescence detection is often the mode of choice. However, the measurement may suffer from a self-absorption (SA) effect which nonlinearly distorts the spectra. The effect is severe when κ is concentrated or the measurements are carried out in certain geometries. Here, the correlations among emission events in compounds are examined following resonance X-ray core-electron excitation within κ. Under conditions leading to SA, If emitted from κ apparently has a conjugated relationship with the fluorescent intensities simultaneously emitted from other elements (ξ). Normalizing the former (κ) by the latter (ξ) will largely remove SA effects and reduce this nonlinear problem to a tractable linear problem. This does result in a moderate reduction of the spectral amplitude due to the so-called secondary emission from ξ excited by the emission from κ. Nonetheless, the resulting spectra will allow one to accurately determine bond distances and disorder and, in some respects, can be superior to spectra obtained via the absorption channel. For μξ < μκ and grazing incidence geometry, the amplitude reduction can be small and simple normalization is sufficient to restore the spectral integrity with remarkable accuracy. This has been instrumental in unravelling the surface and subsurface structures around cations in amorphous Ga–In–O and Zn–Sn–O films which are otherwise inaccessible due to severe SA effects. This method has also been applied to several samples with μξ ≃ μκ to examine its applicability. For these samples, the amplitude reduction is 12 ± 4% versus their standards for the data measured with the classical 45°/45° geometry. This experimental method is easy to implement. Since If from κ and ξ are measured by the same detector system, it is also superior to other methods in removing systematic errors such as detector system nonlinearity, electronic noise, and some beam instabilities, and in removing spectral imperfections due to, for example, SA effects, diffraction effects and sample inhomogeneity. The distortions resulting from the latter can be severe in the spectra measured in transmission mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗

A comparison of quasar absorption line systems with absorption by the galactic halo

Milky Way halo and quasar absorption spectra contain a number of remarkable similarities which include mixed ion absorption, a general absence of excited fine structure levels with the possible exception of excited C II, similar column densities, and similar multicomponent line profiles. The extreme sensitivity of UV lines to small amounts of gas is well illustrated in a comparison of 21-cm H I emission with UV absorption toward the Large Magellanic Cloud. This sensitivity shows that galaxies are likely to appear significantly larger in UV absorption than in 21-cm emission and that the size problem for galactic halos is probably not a serious one. It is concluded that many of the absorption line systems seen in the spectra of quasars are probably produced in the gaseous halos of intervening galaxies.

Savage, B. D.↗

The measurement of absolute absorption of millimeter radiation in gases - The absorption of CO and O2

An apparatus is described that will measure absolute absorption of millimeter radiation in gases. The method measures the change in the quality factor of a Fabry-Perot resonator with and without gas present. The magnitude of the change is interpreted in terms of the absorption of the lossy medium inside the resonator. Experiments have been performed on the 115-GHz CO line and the 119-GHz O2 line at two different temperatures to determine the linewidth parameter and the peak absorption value. These numbers can be combined to give the integrated intensity which can be accurately calculated from results of spectroscopy measurements. The CO results are within 2 percent percent of theoretically predicted valves. Measurements on O2 have shown that absorption can be measured as accurately as 0.5 dB/km with this technique. Results have been obtained for oxygen absolute absorption in the 60-80-GHz region.

Read, William G.↗

Absorption of acoustic waves by sunspots. II - Resonance absorption in axisymmetric fibril models

Analytical calculations of acoustic waves scattered by sunspots which concentrate on the absorption at the magnetohydrodynamic Alfven resonance are extended to the case of a flux-tube embedded in a uniform atmosphere. The model is based on a flux-tubes of varying radius that are highly structured, translationally invariant, and axisymmetric. The absorbed fractional energy is determined for different flux-densities and subphotospheric locations with attention given to the effects of twist. When the flux is highly concentrated into annuli efficient absorption is possible even when the mean magnetic flux density is low. The model demonstrates low absorption at low azimuthal orders even in the presence of twist which generally increases the range of wave numbers over which efficient absorption can occur. Resonance absorption is concluded to be an efficient mechanism in monolithic sunspots, fibril sunspots, and plage fields.

Rosenthal, C. S.↗

The Hubble Space Telescope Quasar Absorption Line Key Project: The Unusual Absorption-Line System in the Spectrum of PG 2302+029--Ejected or Intervening?

We report the discovery of a high-ionization broad absorption line system at a redshift of z(sub abs) = 0.695 in the spectrum of the z(sub em) = 1.052 radio-quiet quasar PG 2302+029. Broad absorption with FWHM from 3000 to 5000 km/s is detected from C iv, N v, and O vi in Hubble Space Telescope (HST) Faint Object Spectrograph spectra of the quasar. A narrow-line system (FWHM approx. 250 km/s) at z(sub abs) = 0.7016 is resolved from the broad blend and includes absorption by Ly alpha and the C iv, N v, and O vi doublets. No absorption by low-ionization metal species (e.g., Si II and Mg II) is detected in the HST or ground-based spectra for either the broad or the narrow system. The centroids of the broad system lines are displaced by approx. 56,000 km/s to the blue of the quasar's broad emission lines. The reddest extent of the broad-line absorption is more than 50,000 km/s from the quasar. The properties of this system are unprecedented, whether it is an intervening or an ejected system.

Jannuzi, B. T.↗

Determining CDOM Absorption Spectra in Diverse Coastal Environments Using a Multiple Pathlength, Liquid Core Waveguide System. Measuring the Absorption of CDOM in the Field Using a Multiple Pathlength Liquid Waveguide System

We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, a(sub CDOM), and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values (r > 0.99) and showed a linear response across all four pathlengths. Values of a(sub CDOM) measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of a(sub CDOM) for MPLCW measurements was 0.002 - 231.5/m. At low CDOM concentrations (a(sub 370) < 0.1/m) spectrophotometric a(sub CDOM) were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples. The maximum deviation in replicate MPLCW spectra was less than 0.001 absorbance units. The portability, sampling, and optical characteristics of a MPLCW system provide significant enhancements for routine CDOM absorption measurements in a broad range of natural waters.

Miller, Richard L.↗