Search NASA⌕ Search

SEARCH · Search NASA

Results for “ABSORPTION IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Direct absorption imaging of ultracold polar molecules

We demonstrate a scheme for direct absorption imaging of an ultracold ground-state polar molecular gas near quantum degeneracy. Imaging molecules without closed optical cycling transitions is challenging. Our technique relies on photon-shot-noise-limited absorption imaging on a strong but open bound-bound molecular transition. We present a systematic characterization of this imaging technique. Using this technique combined with time-of-flight expansion, we demonstrate the capability to determine momentum and spatial distributions for the molecular gas. With its capability of imaging molecules in arbitrary external fields, we anticipate that this technique will find many applications in the study of molecular quantum gases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning imaging absorption spectrometer for atmospheric chartography

The SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY is an instrument which measures backscattered, reflected, and transmitted light from the earth's atmosphere and surface. SCIAMACHY has eight spectral channels which observe simultaneously the spectral region between 240 and 1700 nm and selected windows between 1940 and 2400 nm. Each spectral channel contains a grating and linear diode array detector. SCIAMACHY observes the atmosphere in nadir, limb, and solar and lunar occultation viewing geometries.

Burrows, John P.↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Retrieval and molecule sensitivity studies for the global ozone monitoring experiment and the scanning imaging absorption spectrometer for atmospheric chartography

The Global Ozone Monitoring Experiment (GOME) and the SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) are diode based spectrometers that will make atmospheric constituent and aerosol measurements from European satellite platforms beginning in the mid 1990's. GOME measures the atmosphere in the UV and visible in nadir scanning, while SCIAMACHY performs a combination of nadir, limb, and occultation measurements in the UV, visible, and infrared. A summary is presented of the sensitivity studies that were performed for SCIAMACHY measurements. As the GOME measurement capability is a subset of the SCIAMACHY measurement capability, the nadir, UV, and visible portion of the studies is shown to apply to GOME as well.

Chance, Kelly V.↗

Analysis and calibration of absorptive images of Bose-Einstein condensate at nonzero temperatures

We describe the method allowing quantitative interpretation of absorptive images of mixtures of Bose-Einstein condensate and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction and eliminates arbitrariness of most of the previous approaches. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sublimation and oxidation measurements of graphite and carbon black at high temperatures in a shock tube using absorption imaging and thermal emission

Surface mass loss rates due to sublimation and oxidation at temperatures of 3000–7000 K have been measured in a shock tube for graphite and carbon black (CB) particles. Diagnostics are presented for measuring surface mass loss rates by diffuse backlit illumination extinction imaging and thermal emission. Here, the surface mass loss rate is found by regression fitting extinction and emission signals with an independent spherical primary particle assumption. Measured graphite sublimation and oxidation rates are reported to be an order of magnitude greater than CB sublimation and oxidation rates. It is speculated that the difference between CB and graphite surface mass loss rates is largely due to the primary particle assumption of the presented technique which misrepresents the effective surface area of an aggregate particle where primary particles overlap and shield inner particles. Measured sublimation rates are compared to sublimation models in the literature, and it is seen graphite shows fair agreement with the models while CB underestimates, likely a result of the particle shielding affect not being considered in the sublimation model.

36 MATERIALS SCIENCE↗

Diffusion, thermalization, and optical pumping of YbF molecules in a cold buffer-gas cell

We produce YbF molecules with a density of 10{sup 18} m{sup -3} using laser ablation inside a cryogenically cooled cell filled with a helium buffer gas. Using absorption imaging and absorption spectroscopy we study the formation, diffusion, thermalization, and optical pumping of the molecules. The absorption images show an initial rapid expansion of molecules away from the ablation target followed by a much slower diffusion to the cell walls. We study how the time constant for diffusion depends on the helium density and temperature and obtain values for the YbF-He diffusion cross section at two different temperatures. We measure the translational and rotational temperatures of the molecules as a function of time since formation, obtain the characteristic time constant for the molecules to thermalize with the cell walls, and elucidate the process responsible for limiting this thermalization rate. Finally, we make a detailed study of how the absorption of the probe laser saturates as its intensity increases, showing that the saturation intensity is proportional to the helium density. We use this to estimate collision rates and the density of molecules in the cell.

74 ATOMIC AND MOLECULAR PHYSICS↗

Toward inverse backscatter absorption gas imaging: imaging a dry gas plume with ambient H 2 O absorption

This paper introduces inverse backscatter absorption gas imaging (iBAGI), a transparent gas imaging technique based on absorption spectroscopy of gases naturally present in ambient air being displaced by transparent gases. We demonstrate reconstruction of a 2-D image of a dry gas plume by measuring light of a raster-scanned diode laser tuned to an absorption line of atmospheric H 2 O. We quantify the performance depending on the distance to the backdrop and show that the key transmission metric is independent of absorption path length. We conclude with an outlook toward calibration-free, single-ended iBAGI using scattering from low-reflectivity backdrops.

Klug, Joseph C.↗

Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (~739 ± 98 kPa and ~751 ± 154 kPa for two Xe resonances) is in relatively good agreement with the pressure value of ~758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ~ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others) containing various elements opaque to other more conventional imaging techniques. As a result, the ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Absorption Spectroscopy Imaging of Biological Tissues

X-ray absorption spectroscopy (XAS) is proving invaluable in determining the average chemical form of metals or metalloids in intact biological tissues. As most tissues have spatial structure, there is great additional interest in visualizing the spatial location of the metal(loid) as well as its chemical forms. XAS imaging gives the opportunity of producing maps of specific chemical types of elements in vivo in dilute biological systems. X-ray fluorescence microprobe techniques are routinely used to study samples with spatial heterogeneity. Microprobe produces elemental maps, with chemical sensitivity obtained by recording micro-XAS spectra at selected point locations on the map. Unfortunately, using these procedures spatial detail may be lost as the number of point spectra recorded generally is limited. A powerful extension of microprobe is XAS imaging or chemically specific imaging. Here, the incident energy is tuned to features in the near-edge which are characteristic of the expected chemical forms of the element. With a few simple assumptions, these XAS images can then be converted to quantitative images of specific chemical form, yielding considerable clarity in the distributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Bimodal Absorption System Imaging Campaign (BASIC). I. A Dual Population of Low-metallicity Absorbers at z < 1

The bimodal absorption system imaging campaign (BASIC) aims to characterize the galaxy environments of a sample of 36 H I-selected partial Lyman limit systems (pLLSs) and Lyman limit systems (LLSs) in 23 QSO fields at z ≲ 1. These pLLSs/LLSs provide a unique sample of absorbers with unbiased and well-constrained metallicities, allowing us to explore the origins of metal-rich and low-metallicity circumgalactic medium (CGM) at z < 1. Here we present Keck/KCWI and Very Large Telescope/MUSE observations of 11 of these QSO fields (19 pLLSs) that we combine with Hubble Space Telescope/Advanced Camera for Surveys imaging to identify and characterize the absorber-associated galaxies at 0.16 ≲ z ≲ 0.84. We find 23 unique absorber-associated galaxies, with an average of one associated galaxy per absorber. For seven absorbers, all with <10% solar metallicities, we find no associated galaxies with logM * ≳ 9.0 within ρ/R vir and |Δv|/v esc ≤ 1.5 with respect to the absorber. We do not find any strong correlations between the metallicities or H I column densities of the gas and most of the galaxy properties, except for the stellar mass of the galaxies: the low-metallicity ([X/H] ≤ –1.4) systems have a probability of $0.39_{–0.15}^{+0.16}$ for having a host galaxy with logM * ≥ 9.0 within ρ/R vir ≤ 1.5, while the higher metallicity absorbers have a probability of $0.78_{–0.13}^{+0.10}$. This implies metal-enriched pLLSs/LLSs at z < 1 are typically associated with the CGM of galaxies with logM * > 9.0, whereas low-metallicity pLLSs/LLSs are found in more diverse locations, with one population arising in the CGM of galaxies and another more broadly distributed in overdense regions of the universe. Using absorbers not associated with galaxies, we estimate the unweighted geometric mean metallicity of the intergalactic medium to be [X/H] ≲ –2.1 at z < 1, which is lower than previously estimated.

79 ASTRONOMY AND ASTROPHYSICS↗

Contrast-enhanced spectral mammography with a photon-counting detector

Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. Methods: A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Results: Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another {approx}70%-90% improvement was found to be within reach for an optimized system. Conclusions: Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot X-ray phase-contrast imaging using two-dimensional gratings

We developed a two-dimensional gratings-based X-ray interferometer that requires only a single exposure for clinical radiography. The interferometer consisted of a checkerboard phase grating for {pi} phase modulation and a latticed amplitude grating. Using a synchrotron radiation source, the phase grating modulates the X-rays and generates a self-image, transformed to a moire fringe by the amplitude grating. To allow use of a conventional X-ray tube, the latticed source grating was installed downstream from the X-ray tube. Differential phase-contrast and scattering images in two orthogonal directions were obtained by Fourier analysis of the single moire fringe image and an absorption image. Results show that characteristic features of soft tissue in two orthogonal directions were clearly shown in the differential phase-contrast images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray imaging methods for high-energy density physics applications

Large scale high-energy density science facilities continue to grow in scale and complexity worldwide. The increase in driver capabilities, including pulsed-power and lasers, continue to push the boundaries of temperature, pressure, and densities, opening up new physics regimes. X-ray imaging is one of the many diagnostic techniques that are used to probe states of matter in these extreme conditions. Improved fabrication and polishing methods have provided improved x-ray microscope performance, while improving detector and x-ray sources now enable pico-second imaging with few micron resolutions. Here this Review will cover x-ray imaging methods, primarily absorption imaging, and their improvements over the last few decades.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical investigations of quantum walks by cold atoms in a double optical lattice

We investigate the feasibility of carrying out quantum walks with cold atoms in a double optical lattice. Monte Carlo simulations of time-of-flight (TOF) detection and absorption imaging were carried out, focusing on a specific experimental implementation. These indicate that absorption imaging would be best suited for detection of quantum walks. With typical experimental parameters a few hundred quantum walk steps will be needed for an unambiguous detection of the quantum walk signature. We show that in special cases, few-step quantum walks can also be detected in our system if one measures the relative population of the atoms in their internal states rather than their displacement in space, that is, measurements are made in the space of the coin operator rather than in that of the displacement operator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗