A Novel AC to AC Wireless Power Transfer System for EV Charging Applications

In this paper, a novel ac to ac wireless power transfer (WPT) system is introduced for electric vehicle (EV) charging applications to reduce cost and design complexity. The presented wireless power transfer concept achieves unity power factor (UPF) on the grid-side by using a hybrid frequency ac / ac converter without an additional converter stage and closed loop control compared to the conventional systems. Due to inherent merit of the proposed ac / ac converter, ac input with 60 Hz grid frequency can be directly transferred to the load by superimposing with high frequency switching signal through the wireless coils. To validate the theoretical analysis of the proposed WPT system, the experimental results of the proposed converter are provided for 650 W output power by using 6 inches air gap between the couplers with the input of 110 VRMS ac source. The system overall efficiency is measured 89 % achieving 0.99 power factor (PF) and 1.5 % current total harmonic distortion (THD).

Asa, Erdem↗

Measurement of 227 Ac impurity in 225 Ac using decay energy spectroscopy

225 Ac is a valuable medical radionuclide for targeted $\alpha$ therapy, but 227 Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227 Ac, with the 227 Ac/ 225 Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225 Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from $\alpha$ decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss in this paper. Using this technique we measured the EOB 227 Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.

07 ISOTOPE AND RADIATION SOURCES↗

Inexact convex relaxations for AC optimal power flow: Towards AC feasibility

Convex relaxations of AC optimal power flow (AC-OPF) problems have attracted significant interest as in several instances they provably yield the global optimum to the original non-convex problem. If, however, the relaxation is inexact, the obtained solution is not AC-feasible. The quality of the obtained solution is essential for several practical applications of AC-OPF, but detailed analyses are lacking in existing literature. Here, this paper aims to cover this gap. We provide an in-depth investigation of the solution characteristics when convex relaxations are inexact, we assess the most promising AC feasibility recovery methods for large-scale systems, and we propose two new metrics that lead to a better understanding of the quality of the identified solutions. We perform a comprehensive assessment on 96 different test cases, ranging from 14 to 3120 buses, and we show the following: (i) Despite an optimality gap of less than 1%, several test cases still exhibit substantial distances to both AC feasibility and local optimality and the newly proposed metrics characterize these deviations. (ii) Penalization methods fail to recover an AC-feasible solution in 15 out of 45 test cases. (iii) The computational benefits of warm-starting non-convex solvers have significant variation, but a computational speedup exists in over 75% of cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

Riemannian Optimization Applied to AC Optimal Power Flow: Preprint

The nonlinear, nonconvex AC optimal power flow problem is of growing importance as the nature of the power grid evolves. This problem can be difficult to solve for interior point methods. However, the advent of optimization algorithms over smooth Riemannian manifolds presents an alternative approach. The nonlinear, nonconvex constraints in the AC power flow problem form an embedded submanifold of Euclidean space. In this paper, the authors explore the performance of Riemannian optimization algorithms for the ACOPF problem where the optimization is performed directly on the AC power flow manifold. They demonstrate that these are viable computational alternatives to interior point methods. This is done by using Julia and the packages PowerModels.jl and Manopt.jl.

manifold optimization↗

DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution

DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MIDAS-DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution (MIDAS-DC2AC)

MIDAS DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

Tan, Jin↗

Enabling AC electroluminescence in quasi-2D perovskites by uniformly arranging different-n-value nanoplates to allow bidirectional charge transport

Perovskite light-emitting diodes (LEDs) are normally operated under forward direct current (DC) to realize electron/hole injection at cathode/anode surfaces. In this work, we demonstrate an alternating current (AC) driven LED enabled by bi-directionally allowed charge transport in quasi-2D perovskite (PEA 2 MA n-1 PbnI 3n+1 ) film. Essentially, the bi-directional charge transport is realized by uniformly arranging different-n-value 2D nanoplates together with symmetrically designed anode/cathode interfaces, which can allow injected electrons and holes to form light-emitting states under both forward and reverse biases, leading to an AC electroluminescence (EL) with the device architecture of ITO/PEI/PEDOT:PSS/PEA 2 MA n-1 PbnI 3n+1 /P3HT/PEI/Ag. The high AC EL performance was achieved with the radiance = 24 W Sr -1 m -2 and 18.3 W Sr -1 m -2 and EQE = 12.5% and 3.7% under forward and reverse biases. Furthermore, the device-operational stability was largely improved with the half-intensity time of T 50 = 11.0 h under AC bias (+2 V/-2 V, 50 Hz) as compared to T 50 = 3.9 h under forward bias (+2 V/0 V, 50 Hz).

36 MATERIALS SCIENCE↗

Modeling the AC Power Flow Equations with Optimally Compact Neural Networks: Application to Unit Commitment

Nonlinear power flow constraints render a variety of power system optimization problems computationally intractable. Emerging research shows, however, that the nonlinear AC power flow equations can be successfully modeled using neural networks. These neural networks can be exactly transformed into mixed integer linear programs and embedded inside challenging optimization problems, thus replacing nonlinearities that are intractable for many applications with tractable piecewise linear approximations. Such approaches, though, suffer from an explosion of the number of binary variables needed to represent the neural network. Accordingly, this paper develops a technique for training an "optimally compact'' neural network, i.e., one that can represent the power flow equations with a sufficiently high degree of accuracy while still maintaining a tractable number of binary variables. We demonstrate the use of this neural network as an approximator of the nonlinear power flow equations by embedding it in the AC unit commitment problem, transforming the problem from a mixed integer nonlinear program into a more manageable mixed integer linear program. We use the 14-, 57-, and 89-bus networks as test cases and compare the AC-feasibility of commitment decisions resulting from the neural network, DC, and linearized power flow approximations. Our results show that the neural network model outperforms both the DC and linearized power flow approximations when embedded in the unit commitment problem. The neural network formulation most often selects a feasible unit commitment schedule, and furthermore, it only s

AC power flow↗

A Universal Converter for DC, Single-phase AC, and Multi-phase AC Systems (Final Report)

The goal of this project was to develop a new class of universal power converters that utilize the unique properties of WBG switches, including high reverse voltage blocking and fast switching, to achieve superior performance in universal converters. Some of the features of the proposed converter are as follows: 1) Significantly longer lifetime, higher power density, lower costs associated with bill of materials, and lower shipping, installation, and repair costs compared to the existing WBG-based solutions, 2) Very flexible operation for transferring power between any type of source (dc, single-phase ac, or multi-phase ac) and any type of load (dc, single-phase ac, or multi-phase ac) without using large passive components or additional stages/components, even when the instantaneous values of input and output power are not the same, and 3) High performance operation at all power levels. Considering its advantages and wide range of applications, the proposed converter has the potential to create a new paradigm in power electronics. Among numerous applications of this converter are electric vehicles, wind energy systems, PV systems, industrial motor drives, residential variable frequency drive systems, and nanogrid applications. This project focused on the application of this converter for residential PV, residential motor drive, and industrial motor drive applications, and evaluated the performance of this converter for these applications.

42 ENGINEERING↗

AC to AC Solid State Transformer with Bidirectional Switches

This report details the work of the 3-year project for the AC-to-AC Solid State Transformer with Bidirectional Switches project devoted to developing and demonstrated a Type I Solid State Transformer. This report details the design, fabrication, and evaluation of both three-phase and single-phase versions of this solid state transformer operating as a single module, modules in parallel, and modules in cascade. Additionally, this report details the fabrication and evaluation of custom Silicon Carbide bidirectional switches to enable this topology with a comparison between monolithically integrated bidirectional switches as well as co-packaged back-to-back unidirectional devices. Finally, results for custom-fabricated Fe 4 N/ferrite laminated toroidal cores for high frequency transformers are present.

42 ENGINEERING↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗

Unfolder-based single-stage AC-AC conversion system

An power converter includes an unfolder connected to a three-phase source and has an output connection with a positive terminal, a negative terminal and a neutral terminal. The unfolder creates two unipolar piece-wise sinusoidal DC voltage waveforms offset by a half of a period. A three-input converter connected to the unfolder produces a quasi-sinusoidal output voltage across output terminals. Switches of the converter selectively connect the positive, negative and neutral inputs across the output terminals. A PWM controller controls a first duty ratio and a second duty ratio for the converter based on a phase angle of the source and a modulation index generated from an error signal related to a control variable. The duty ratios are time varying with a fundamental frequency of the source. The modulation index relates to output voltage of the converter, peak voltage or current of the source and/or peak current at the output terminals.

Teeneti, Chakridhar Reddy↗

Unfolder-based single-stage AC-AC conversion system

A power converter includes an unfolder connected to a three-phase source and has an output connection with three output terminals. A three-input converter connected to the unfolder produces a quasi-sinusoidal output voltage across converter output terminals. Switches of the converter selectively connect each of the three output terminals across the converter output terminals. A pulse-width modulation controller controls a first duty ratio and a second duty ratio for the converter based on a phase angle of the source and a modulation index generated from an error signal related to a control variable. The duty ratios are time varying at a rate related to a fundamental frequency of the source. The modulation index relates to output voltage of the converter, peak voltage or current of the source and/or peak current at the output terminals.

Teeneti, Chakridhar Reddy↗