Formula for thermal accommodation coefficients.
Formula for thermal accommodation coefficient as basis for accommodation coefficient of monatomic gas-solid system calculation
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Formula for thermal accommodation coefficient as basis for accommodation coefficient of monatomic gas-solid system calculation
Thermal accommodation coefficient measurements with rare gases and metals and alkali metal sets
Normal and tangential momentum accommodation coefficients in low density facility
A CFD model for simulating the self-pressurization of a large scale liquid hydrogen storage tank is utilized in this paper to model the MHTB self-pressurization experiment. The kinetics-based Schrage equation is used to account for the evaporative and condensi ng interfacial mass flows in this model. The effect of the accommodation coefficient for calculating the interfacial mass transfer rate on the tank pressure during tank selfpressurization is studied. The values of the accommodation coefficient which were considered in this study vary from 1.0e-3 to 1.0e-1 for the explicit VOF model and from 1.0e-4 to 1.0e-3 for the implicit VOF model. The ullage pressure evolutions are compared against experimental data. A CFD model for controlling pressure in cryogenic storage tanks by spraying cold liquid into the ullage is also presented. The Euler-Lagrange approach is utilized for tracking the spray droplets and for modeling the interaction between the droplets and the continuous phase (ullage). The spray model is coupled with the VOF model by performing particle tracking in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. Droplet-ullage heat and mass transfer are modeled. The flow, temperature, and interfacial mass flux, as well as droplets trajectories, size distribution and temperatures predicted by the model are presented. The ul lage pressure and vapor temperature evolutions are compared with experimental data obtained from the MHTB spray bar mixing experiment. The effect of the accommodation coefficient for calculating the interfacial and droplet mass transfer rates on the tank pressure during mixing of the vapor using spray is studied. The values used for the accommodation coefficient at the interface vary from 1.0e-5 to 1.0e-2. The droplet accommodation coefficient values vary from 2.0e-6 to 1.0e-4.
Thermal accommodation coefficients determination in temperature jump region
Aerodynamic torque on spinning spherical satellite, noting applications to accommodation coefficient measurement and study of aerodynamic gas-surface interactions
We have determined the accommodation coefficient, gamma, of a helium film from 1.15 to 4 K by measuring the time constant of a rotating superconducting Nb sphere levitated in vapor and covered with a saturated helium film. The conventional assumption of the phenomenological theory of superfluidity, that the order parameter psi vanishes at the free surface of helium II, implies that gamma, is unity and independent of temperature. We find that gamma, is nearly unity above the lambda point, suffers an abrupt drop close to T-lambda, and gradually levels off to the value of about 0.8 at lower temperatures.
Thermal accommodation coefficients of Ar atomic beams scattered from nominal plane of Ag crystal measured by time of flight techniques
Molecular beam apparatus for determining momentum accommodation coefficients for neutral particle - surface interactions
Energy accommodation coefficients for He3-W and He4-W, comparing results with classical gas-solid interaction theory
Accommodation coefficients ratio of He 4 to He 3 measured on W and K clean surfaces
Preliminary results are reported of the direct measurement of accommodation coefficients for HNO3, N2O5 and HCl on water drops, aqueous sulfuric acid drops and ice particles. The heterogeneous chemistry of these species together with ClONO2 has been implicated in the ozone depletion observed in the Antarctic stratosphere during the spring in the last eight years. The most plausible chemical mechanism involves the removal of nitrogen oxide species via condensation on ice particles in polar stratospheric clouds resulting in a increase in the active chlorine species responsible for the ozone depletion. The observation of low NO2 and high ClO densities in the Antarctic stratosphere last summer appear to be consistent with such a mechanism.
High energy molecular beam apparatus and optical lever for measurement of momentum and energy accommodation coefficients under satellite conditions
Nonequilibrium liquid/vapor phase transformations can occur in superheated or subcooled liquids in fast processes such as in evaporation in a vacuum. The rate at which such a phase transformation occurs depends on the "condensation" or "accommodation" coefficient, Beta, which is a property of the interface. Existing measurement techniques for Beta are complex and expensive. The development of a relatively inexpensive and reliable technique for measurement of Beta for a wide range of substances and temperatures is of great practical importance. The dynamics of a bubble in an acoustic field strongly depends on the value of Beta. It is known that near the saturation temperature, small vapor bubbles grow under the action of an acoustic field due to "rectified heat transfer." This finding can be used as the basis for an effective measurement technique of Beta. We developed a theory of vapor bubble behavior in an isotropic acoustic wave and in a plane standing acoustic wave. A numerical code was developed which enables simulation of a variety of experimental situations and accurately takes into account slowly evolving temperature. A parametric study showed that the measurement of Beta can be made over a broad range of frequencies and bubble sizes. We found several interesting regimes and conditions which can be efficiently used for measurements of Beta. Measurements of Beta can be performed in both reduced and normal gravity environments.
In this paper, a computational model that describes pressure control phase of a typical MHTB experiment will be presented. The fidelity of the model will be assessed by comparing the models predictions with MHTB experimental data. In this paper CFD results for MHTB spray bar cooling case with 50 tank fill ratio will be presented and analyzed. Effect of accommodation coefficient for calculating droplet-ullage mass transfer will be evaluated.
The Magellan spacecraft was inserted into an elliptical orbit around the planet Venus on August 10, 1990. A small aerodynamic force was applied later to the spacecraft for 730 consecutive orbits to lower the apoapsis of the orbit from 8500 km to 541 km. Atmospheric drag removed a maximum of 2 m/sec per orbit from the velocity at periapsis for a total delta-V of 1200 m/sec. This paper will discuss the thermal accommodation coefficient which was inferred from one of the four solar panel temperature measurements from the aerobraking pass through the atmosphere.
Aerodynamic torque equations for axis motion of spinning spherical satellite
Laminar models agree closely with the pressure evolution and vapor phase temperature stratification but under-predict liquid temperatures. Turbulent SST k-w and k-e models under-predict the pressurization rate and extent of stratification in the vapor but represent liquid temperature distributions fairly well. These conclusions seem to equally apply to large cryogenic tank simulations as well as small scale simulant fluid pressurization cases. Appropriate turbulent models that represent both interfacial and bulk vapor phase turbulence with greater fidelity are needed. Application of LES models to the tank pressurization problem can serve as a starting point.