Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACCURACY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Large-Scale Materials Modeling at Quantum Accuracy: Ab Initio Simulations of Quasicrystals and Interacting Extended Defects in Metallic Alloys

Ab initio electronic-structure has remained dichotomous between achievable accuracy and length-scale. Quantum many-body (QMB) methods realize quantum accuracy but fail to scale. Density functional theory (DFT) scales favorably but remains far from quantum accuracy. We present a framework that breaks this dichotomy by use of three interconnected modules: (i) invDFT: a methodological advance in inverse DFT linking QMB methods to DFT; (ii) MLXC: a machine-learned density functional trained with invDFT data, commensurate with quantum accuracy; (iii) DFT-FE-MLXC: an adaptive higher-order spectral finite-element (FE) based DFT implementation that integrates MLXC with efficient solver strategies and HPC innovations in FE-specific dense linear algebra, mixed-precision algorithms, and asynchronous compute-communication. Furthermore, we demonstrate a paradigm shift in DFT that not only provides an accuracy commensurate with QMB methods in ground-state energies, but also attains an unprecedented performance of 659.7 PFLOPS (43.1% peak FP64 performance) on 619,124 electrons using 8,000 GPU nodes of Frontier supercomputer.

density functional theory↗

Registration accuracy and attitude accuracy

Since higher spatial resolution is desired by many applications disciplines coupled with registration in the sub-to-1 pixel range, improved registration accuracy has become necessary. The trend is likely to continue, with image data resolution of 10 meters or less being a routine requirement before the end of this decade. This registration accuracy can only be achieved by the combination of registration and attitude accuracy. This report described the need for improving the attitude accuracy. The relationship between registration accuracy and attitude accuracy is shown, along with criteria for design consideration in establishing adequate attitude accuracy. A precise on-board attitude control system design is essential to provide the attitude accuracy needed to support the subpixel accuracy required for registration of higher resolution images.

Fang, A. C.↗

Evolution of methods of assessing the accuracy of metal-cutting machines. 2. Evolution of concepts and models used in assessing the accuracy of metal-cutting machines

The evolution of methods used in assessing and monitoring the accuracy of metal-cutting machines is considered. Changes in terminology and in the concept of accuracy are discussed. Relations between the evolution of accuracy and the methods used for its determination are presented, in the context of the most important developments responsible for machine-tool accuracy. The development of models of machine-tool accuracy is reviewed, and the corresponding mathematical apparatus for the accuracy assessment is presented. The applicability of the various approaches is determined.

42 ENGINEERING↗

Improving Collision Induced Dissociation (CID), High Energy Collision Dissociation (HCD), and Electron Transfer Dissociation (ETD) Fourier Transform MS/MS Degradome-Peptidome Identifications Using High Accuracy Mass Information

Identification of peptides through analysis of peptide ion fragmentation mass spectra is key to proteomic/peptidomic studies. Advanced mass spectrometry has enabled measurement of peptide fragments with {approx}ppm mass error levels; however, mass accuracy has not been widely utilized in broad aspects of peptide identification. In this work we describe how peptide high-precision fragments measured with Fourier transform mass spectrometry can provide a powerful discriminative capability to distinguish true peptide 'hits' from possible incorrect peptides. For identification of peptides having multiple termini and carrying multiple charges, we show that the simple utilization of high-precision mass fragments information results in improved peptide analysis coverage and consistency, with coverage of >95% peptides identified totally from different spectral scoring and peptide statistic probability methods developed for moderate accuracy mass spectral peptide identification.

59 BASIC BIOLOGICAL SCIENCES↗

High-accuracy {sup 233}U(n,f) cross-section measurement at the white-neutron source n{sub T}OF from near-thermal to 1 MeV neutron energy

The {sup 233}U(n,f) cross section has been measured at the white neutron source n{sub T}OF in a wide energy range with a dedicated fission ionization chamber. We report here the results from {approx}30 meV to 1 MeV neutron energy. The {sup 233}U(n,f) cross section has been determined relative to a reference sample of {sup 235}U(n,f) measured simultaneously with the same detector. The very high instantaneous neutron flux and the intrinsically low background of the n{sub T}OF installation result in an accuracy around 3% in the whole energy range, while the energy resolution of the neutron beam allows for an accurate description of the fission cross section by means of R-matrix analysis over a wide energy range. The results are, in general, in good agreement with the most recent high-accuracy measurement of this fission cross section, over the more limited range of the previous measurements, and indicated that even the latest evaluations underestimate the cross section in the epithermal region. The present high-quality data provide the basis for a more precise evaluation of the {sup 233}U fission cross section and for improving the reliability of databases needed for the design of new energy systems based on the Th/U cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Insensitivity of the octahedral spherical hohlraum to power imbalance, pointing accuracy, and assemblage accuracy

The random radiation asymmetry in the octahedral spherical hohlraum [K. Lan et al., Phys. Plasmas 21, 0 10704 (2014)] arising from the power imbalance, pointing accuracy of laser quads, and the assemblage accuracy of capsule is investigated by using the 3-dimensional view factor model. From our study, for the spherical hohlraum, the random radiation asymmetry arising from the power imbalance of the laser quads is about half of that in the cylindrical hohlraum; the random asymmetry arising from the pointing error is about one order lower than that in the cylindrical hohlraum; and the random asymmetry arising from the assemblage error of capsule is about one third of that in the cylindrical hohlraum. Moreover, the random radiation asymmetry in the spherical hohlraum is also less than the amount in the elliptical hohlraum. The results indicate that the spherical hohlraum is more insensitive to the random variations than the cylindrical hohlraum and the elliptical hohlraum. Hence, the spherical hohlraum can relax the requirements to the power imbalance and pointing accuracy of laser facility and the assemblage accuracy of capsule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

Environmental Molecular Sciences Laboratory↗

An improved method to increase the predictive accuracy of the ECR technique

The technique of electrical conductivity relaxation (ECR) is a widely utilized method for obtaining oxygen chemical surface exchange (k) and bulk diffusion (D) coefficients for mixed ionic electronic conductors. Although the technique is conceptually simple, its practical application does not frequently produce reliably accurate values of k and D, and many examples of poor agreement can be found in the published literature. In this present paper, methods for enhancing the accuracy of the ECR technique relative to data processing are described in detail. Physically accurate determination of the actual starting time (t{sub 0}) and improved methods for data fitting of ECR measurements are discussed. To test the methods described, generated relaxation data sets are analyzed by using non-linear-least-square (NLLS) methods. The results showed that fixing t{sub 0} based on an ideally stirred reactor model improves the fitted results compared to treating t{sub 0} as a fitted parameter. Additionally, evaluation of the global minimum in the fitted error is made by analyzing multiple samples of varying thickness, which improves parameter evaluation compared to analysis of a single relaxation data set. The improved accuracy of the computed values of k and D is described in comparison to conventional methods.

Bulk diffusion coefficient↗

Probing Accuracy-Speedup Tradeoff in Machine Learning Surrogates for Molecular Dynamics Simulations

The performance promise of machine learning surrogates of molecular dynamics simulations of soft materials is significant but generally comes at the cost of acquiring large training datasets to learn the complex relationships between input soft material attributes and output properties. Under the constraint of limited high-performance computing resources, optimizing the size of the training datasets becomes paramount. Using an artificial neural network based surrogate for molecular dynamics simulations of confined electrolytes, we explore the tradeoff between surrogate accuracy and computational gains. Accuracy is assessed by computing the root-mean-square errors between the surrogate predictions and the ground truth results obtained via molecular dynamics simulations. The computational performance is judged by evaluating the speedup which incorporates the training dataset creation time. Improvement in accuracy occurs with a loss of speedup, which scales as the inverse of the training dataset size. Furthermore, the link between surrogate generalizability and the accuracy-speedup tradeoff is assessed by examining the errors incurred in surrogate predictions on unseen, interpolated input variables and developing a net speedup metric to capture the associated gains.

Anions↗

On the accuracy of the MB-pol many-body potential for water: Interaction energies, vibrational frequencies, and classical thermodynamic and dynamical properties from clusters to liquid water and ice

The MB-pol many-body potential has recently emerged as an accurate molecular model for water simulations from the gas to the condensed phase. In this study, the accuracy of MB-pol is systematically assessed across the three phases of water through extensive comparisons with experimental data and high-level ab initio calculations. Individual many-body contributions to the interaction energies as well as vibrational spectra of water clusters calculated with MB-pol are in excellent agreement with reference data obtained at the coupled cluster level. Several structural, thermodynamic, and dynamical properties of the liquid phase at atmospheric pressure are investigated through classical molecular dynamics simulations as a function of temperature. The structural properties of the liquid phase are in nearly quantitative agreement with X-ray diffraction data available over the temperature range from 268 to 368 K. The analysis of other thermodynamic and dynamical quantities emphasizes the importance of explicitly including nuclear quantum effects in the simulations, especially at low temperature, for a physically correct description of the properties of liquid water. Furthermore, both densities and lattice energies of several ice phases are also correctly reproduced by MB-pol. Following a recent study of DFT models for water, a score is assigned to each computed property, which demonstrates the high and, in many respects, unprecedented accuracy of MB-pol in representing all three phases of water. Published by AIP Publishing.

Reddy, Sandeep K. (ORCID:0000000214586853)↗

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]↗

Exploring the limit of accuracy for density functionals based on the generalized gradient approximation: Local, global hybrid, and range-separated hybrid functionals with and without dispersion corrections

The limit of accuracy for semi-empirical generalized gradient approximation (GGA) density functionals is explored by parameterizing a variety of local, global hybrid, and range-separated hybrid functionals. The training methodology employed differs from conventional approaches in 2 main ways: (1) Instead of uniformly truncating the exchange, same-spin correlation, and opposite-spin correlation functional inhomogeneity correction factors, all possible fits up to fourth order are considered, and (2) Instead of selecting the optimal functionals based solely on their training set performance, the fits are validated on an independent test set and ranked based on their overall performance on the training and test sets. The 3 different methods of accounting for exchange are trained both with and without dispersion corrections (DFT-D2 and VV10), resulting in a total of 491 508 candidate functionals. For each of the 9 functional classes considered, the results illustrate the trade-off between improved training set performance and diminished transferability. Since all 491 508 functionals are uniformly trained and tested, this methodology allows the relative strengths of each type of functional to be consistently compared and contrasted. The range-separated hybrid GGA functional paired with the VV10 nonlocal correlation functional emerges as the most accurate form for the present training and test sets, which span thermochemical energy differences, reaction barriers, and intermolecular interactions involving lighter main group elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the many-body expansion for large systems. II. Accuracy considerations

To complement our study of the role of finite precision in electronic structure calculations based on a truncated many-body expansion (MBE, or “n-body expansion”), we examine the accuracy of such methods in the present work. Accuracy may be defined either with respect to a supersystem calculation computed at the same level of theory as the n-body calculations, or alternatively with respect to high-quality benchmarks. Both metrics are considered here. In applications to a sequence of water clusters, (H{sub 2}O){sub N=6−55} described at the B3LYP/cc-pVDZ level, we obtain mean absolute errors (MAEs) per H{sub 2}O monomer of ∼1.0 kcal/mol for two-body expansions, where the benchmark is a B3LYP/cc-pVDZ calculation on the entire cluster. Three- and four-body expansions exhibit MAEs of 0.5 and 0.1 kcal/mol/monomer, respectively, without resort to charge embedding. A generalized many-body expansion truncated at two-body terms [GMBE(2)], using 3–4 H{sub 2}O molecules per fragment, outperforms all of these methods and affords a MAE of ∼0.02 kcal/mol/monomer, also without charge embedding. GMBE(2) requires significantly fewer (although somewhat larger) subsystem calculations as compared to MBE(4), reducing problems associated with floating-point roundoff errors. When compared to high-quality benchmarks, we find that error cancellation often plays a critical role in the success of MBE(n) calculations, even at the four-body level, as basis-set superposition error can compensate for higher-order polarization interactions. A many-body counterpoise correction is introduced for the GMBE, and its two-body truncation [GMBCP(2)] is found to afford good results without error cancellation. Together with a method such as ωB97X-V/aug-cc-pVTZ that can describe both covalent and non-covalent interactions, the GMBE(2)+GMBCP(2) approach provides an accurate, stable, and tractable approach for large systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

QCD static energy at next-to-next-to-next-to leading-logarithmic accuracy

We compute the static energy of QCD at short distances at next-to-next-to-next-to-leading logarithmic accuracy in terms of the three-loop singlet potential. By comparing our results with lattice data we extract the value of the unknown piece of the three-loop singlet potential.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-57: Delivered Activity Accuracy of Radium 223 Dichloride Injections, When Being Administrated for Castration Resistant Prostate Cancer, Symptomatic Bone Metastases. The Impact of Residual Activity in the Spent Syringe and Dispensing Accuracy of Ra 223

Purpose: To quantify the delivered activity accuracy of Radium 223 dichloride injections, when being administrated for castration – resistant prostate cancer, symptomatic bone metastases. The impact of residual activity in the spent syringe and dispensing accuracy of Ra 223. Methods: The administration is by slow intravenous injection over 1 minute followed by double flushing of the 10 mL syringe and IV with saline. Eighty (80) procedures was used to investigate variations in the activity from the amount prescribed (µCi) = 1.35 × Patient weight Kg. The Activity dispensed into a 10mL syringe using a NIST traceable Capintec CRC-25R Chamber and a cross calibrated capintec CRC-15R to measure activity in the syringe immediately before and after administration Results: The patients weight range from 121Ib to 235lb and doses ranging 74.25 µCi to 144.2 µCi. The deviation of dispensed dose vs Prescribed dose average +2.1% with a range of −1.1% to +5.7%. The Dose measured before administration ranges 79.3 µCi to 154.9 µCi. Deviation from the dispensed dose was show to average +2.9% with a range of −0.8% to +7.3%. The average residual dose post injection was 2.5 µCi or 2.2% of the pre injection activity. Ranging from 0.9 µCi to 6.2 µCi, 0.7% to 5.4% respectively. Subtracting the residual activity from that measured activity before injection and comparing it to prescription dose was shown to have an average variation of +2.7% with a range of −0.8% to 7.4%. Conclusion: The case resulted in the 6.2 µCi maximum residual dose had two syringes. A small, 82.8 µCi activity, case resulted in the 7.4% maximum variation in measures less residual verses prescription dose. The average +2.1 % dispenses activity of Ra 223 over the prescription dosage was seen to counteract the average 2.2% residual dosage found to remain in the syringe.

60 APPLIED LIFE SCIENCES↗

Improved precision and accuracy in quantifying plutonium isotope ratios by RIMS

Resonance ionization mass spectrometry (RIMS) holds the promise of rapid, isobar-free quantification of actinide isotope ratios in as-received materials (i.e. not chemically purified). Recent progress in achieving this potential using two Pu test materials is presented. RIMS measurements were conducted multiple times over a period of two months on two different Pu solutions deposited on metal surfaces. Measurements were bracketed with a Pu isotopic standard, and yielded absolute accuracies of the measured Pu-240/Pu-239 ratios of 0.7 and 0.58 %, with precisions (95 % confidence intervals) of 1.49 and 0.91 %. The minor isotope Pu-238 was also quantified despite the presence of a significant quantity of U-238 in the samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗