Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC ATTENUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Monitoring the State-of-Charge of a Vanadium Redox Flow Battery with the Acoustic Attenuation Coefficient: An In Operando Noninvasive Method

Redox flow battery technology has been increasingly recognized as a promising option for large-scale grid energy storage. Access to high-fidelity information on the health status of the electrolyte, including the state-of-charge (SOC), is vital to maintaining optimal and economical battery operation. In this study, an ultrasonic probing cell that can be used to measure SOC in real time is designed. This unprecedented, new measurement approach overcomes the influence of varying temperatures by measuring the acoustic attenuation coefficient of the redox flow battery electrolyte online and noninvasively. The new approach is used to estimate the SOC of a vanadium redox flow battery (VRFB) in operando from measured acoustic properties. The accuracy of the SOC estimated from the acoustic properties is validated against SOC calculated by the titration method. The results show that the acoustic attenuation coefficient is a robust parameter for SOC monitoring, with a maximum error of 4.8% and extremely low sensitivity to temperature, while sound speed appears to be less accurate in the benchmark-inference method, with a maximum error of 22.5% and high sensitivity to temperature. The acoustic measurement approach has great potential for inexpensive real-time SOC monitoring of redox flow battery operations.

25 ENERGY STORAGE↗

In operando, non-invasive state-of-charge monitoring for redox flow batteries

This document describes techniques and systems for in operando, non-invasive SOC monitoring of redox flow batteries. The described techniques and systems allow for accurate, inexpensive, portable, and real-time methods to measure the SOC of redox flow batteries. System operators can monitor the SOC by measuring an acoustic attenuation coefficient of the electrolyte in the redox flow battery. The acoustic attenuation coefficient is measured using an ultrasonic transducer attached to a probing cell, which is connected to an electrolyte flow of a redox flow battery. The acoustic attenuation coefficient provides an accurate, real-time SOC measurement that is generally insensitive to varying operational temperatures of the electrolyte solution.

25 ENERGY STORAGE↗

Online and noninvasive monitoring of battery health at negative-half cell in all-vanadium redox flow batteries using ultrasound

Hydrogen evolution is one of the major side reactions that is detrimental to the health of all-vanadium redox flow batteries, especially for long-term cycling. Effective, low-cost, and accurate online prediction and detection methods for hydrogen generation are not yet available. In this work, we designed an online, noninvasive ultrasonic probing approach for monitoring the state of charge (SoC), predicting the hydrogen generation, and detecting hydrogen gas bubbles in anolyte solutions. The technique employs a pulse-echo method to measure the sound speed and the acoustic attenuation coefficient of the anolyte solution. Through static offline experiments and online in operando experiments, we have demonstrated that when hydrogen gas is generated in anolyte solutions, large variations are observed in both sound speed and acoustic attenuation coefficient measurements. We found that the variations of acoustic attenuation coefficient are highly correlated (correlation coefficients >0.9) with the gas flow rate. In conclusion, the designed acoustic method can monitor the SoC of anolyte, predict the hydrogen generation, and detect the presence of gas bubbles in an anolyte solution and, thus, provide information about the state of health for operation and management of flow battery systems.

25 ENERGY STORAGE↗

Studies of elasticity, sound propagation and attenuation of acoustic modes in granular media: final report

This is the final report describing the results of DOE Grant # DE-FG02-03ER15458 with original termination date of April 31, 2013, which has been extended to April 31, 2014. The goal of this project is to develop a theoretical and experimental understanding of sound propagation, elasticity and dissipation in granular materials. The topic is relevant for the efficient production of hydrocarbon and for identifying and characterizing the underground formation for storage of either CO 2 or nuclear waste material. Furthermore, understanding the basic properties of acoustic propagation in granular media is of importance not only to the energy industry, but also to the pharmaceutical, chemical and agricultural industries. We employ a set of experimental, theoretical and computational tools to develop a study of acoustics and dissipation in granular media. These include the concept effective mass of granular media, normal modes analysis, statistical mechanics frameworks and numerical simulations based on Discrete Element Methods. Effective mass measurements allow us to study the mechanisms of the elastic response and attenuation of acoustic modes in granular media. We perform experiments and simulations under varying conditions, including humidity and vacuum, and different interparticle force-laws to develop a fundamental understanding of the mechanisms of damping and acoustic propagation in granular media. A theoretical statistical approach studies the necessary phase space of configurations in pressure, volume fraction to classify granular materials.

58 GEOSCIENCES↗

Additively manufactured locally resonant interpenetrating lattice structure

A method and apparatus for attenuating acoustic waves is provided. A lattice is formed with a plurality of support struts. A plurality of resonating struts are formed extending between the support struts, wherein the resonating struts are configured to attenuate acoustic waves within a predetermined range of frequencies while allowing acoustic waves outside the predetermined range of frequencies to pass through the resonant structure unattenuated. The resonant structure is interposed between two bodies to isolate one body from acoustic waves from the other body over the predetermined range of frequencies.

Hammetter, Chris↗

SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement

Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic a human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.

60 APPLIED LIFE SCIENCES↗

Electrochemical-acoustic time of flight: in operando correlation of physical dynamics with battery charge and health

We demonstrate that a simple acoustic time-of-flight experiment can measure the state of charge and state of health of almost any closed battery. An acoustic conservation law model describing the state of charge of a standard battery is proposed, and experimental acoustic results verify the simulated trends; furthermore, a framework relating changes in sound speed, via density and modulus changes, to state of charge and state of health within a battery is discussed. Regardless of the chemistry, the distribution of density within a battery must change as a function of state of charge and, along with density, the bulk moduli of the anode and cathode changes as well. The shifts in density and modulus also change the acoustic attenuation in a battery. Experimental results indicating both state-of-charge determination and irreversible physical changes are presented for two of the most ubiquitous batteries in the world, the lithium-ion 18650 and the alkaline LR6 (AA). Overall, a one-or two-point acoustic measurement can be related to the interaction of a pressure wave at multiple discrete interfaces within a battery, which in turn provides insights into state of charge, state of health, and mechanical evolution/degradation.

Hsieh, AG↗

Paracousti v. 2.0.0

Paracousti simulates 3-D acoustic wave propagation in fixed (non-moving) complex media. It solves the linear acoustic equations of motion using the velocity-pressure system of first order linear differential equations on a finite-difference Cartesian grid using Newton’s law of motion and mass continuity equations. It also has the ability to incorporate acoustic attenuation to simulate non-recoverable energy losses via the velocity-memory-pressure system of linear differential equations. We assume stationary, non-heat conducting, adiabatic media (fluid) where the background sound speed and material density are fixed in time. Capabilities include massively parallel design, optimization for high contrast media interfaces, inclusion of arbitrary pressure and force sources defined by the user, inclusion of arbitrary pressure and velocity receivers defined by the user, acoustic wavefield snapshots in time for visualization, and convolutional perfectly matched layers to minimize artificial grid boundary reflections. Paracousti was built upon the foundational framework of TDAAPS (Time-Domain Atmospheric Acoustic Propagation Suite) by Neill Symons, Dave Aldridge, and Leiph Preston.

Preston, Leiph↗

Dynamics of Gas Bubbles From a Submarine Hydrocarbon Seep Within the Hydrate Stability Zone

We validate a new model for mass transfer and bubble transport for natural seeps on the continental margins using an integrated observation of a seep at 883 m in the Northern Gulf of Mexico. In the model, mass transfer is assumed to transition from clean to dirty bubble mass transfer rates following a characteristic hydrate formation time that depends on the initial bubble surface area and the hydrate subcooling. We show that buoyancy-induced upwelling is negligible for the bubble stream. We initialize the model using precise data observed at the seafloor and validate the model results to optical and acoustic measurements within the bubble stream. The model accurately predicts the acoustic attenuation of the bubble flare by lateral spreading and bubble shrinkage throughout the water column. In conclusion, the model shows that up to 99.4% by mass of the released gases from this seep dissolves into the ocean within the hydrate stability zone.

03 NATURAL GAS↗

SU-F-I-14: 3D Breast Digital Phantom for XACT Imaging

Purpose: The X-ray induced acoustic computed tomography (XACT) is a new imaging modality which combines X-ray contrast and high ultrasonic resolution in a single modality. Using XACT in breast imaging, a 3D breast volume can be imaged by only one pulsed X-ray radiation, which could dramatically reduce the imaging dose for patients undergoing breast cancer screening and diagnosis. A 3D digital phantom that contains both X-ray properties and acoustic properties of different tissue types is indeed needed for developing and optimizing the XACT system. The purpose of this study is to offer a realistic breast digital phantom as a valuable tool for improving breast XACT imaging techniques and potentially leading to better diagnostic outcomes. Methods: A series of breast CT images along the coronal plane from a patient who has breast calcifications are used as the source images. A HU value based segmentation algorithm is employed to identify breast tissues in five categories, namely the skin tissue, fat tissue, glandular tissue, chest bone and calcifications. For each pixel, the dose related parameters, such as material components and density, and acoustic related parameters, such as frequency-dependent acoustic attenuation coefficient and bandwidth, are assigned based on tissue types. Meanwhile, other parameters which are used in sound propagation, including the sound speed, thermal expansion coefficient, and heat capacity are also assigned to each tissue. Results: A series of 2D tissue type image is acquired first and the 3D digital breast phantom is obtained by using commercial 3D reconstruction software. When giving specific settings including dose depositions and ultrasound center frequency, the X-ray induced initial pressure rise can be calculated accordingly. Conclusion: The proposed 3D breast digital phantom represents a realistic breast anatomic structure and provides a valuable tool for developing and evaluating the system performance for XACT.

60 APPLIED LIFE SCIENCES↗

Roles of bulk viscosity on Rayleigh-Taylor instability: Non-equilibrium thermodynamics due to spatio-temporal pressure fronts

Direct numerical simulations of Rayleigh-Taylor instability (RTI) between two air masses with a temperature difference of 70 K is presented using compressible Navier-Stokes formulation in a non-equilibrium thermodynamic framework. The two-dimensional flow is studied in an isolated box with non-periodic walls in both vertical and horizontal directions. The non-conducting interface separating the two air masses is impulsively removed at t = 0 (depicting a heaviside function). No external perturbation has been used at the interface to instigate the instability at the onset. Computations have been carried out for rectangular and square cross sections. The formulation is free of Boussinesq approximation commonly used in many Navier-Stokes formulations for RTI. Effect of Stokes’ hypothesis is quantified, by using models from acoustic attenuation measurement for the second coefficient of viscosity from two experiments. Effects of Stokes’ hypothesis on growth of mixing layer and evolution of total entropy for the Rayleigh-Taylor system are reported. The initial rate of growth is observed to be independent of Stokes’ hypothesis and the geometry of the box. Following this stage, growth rate is dependent on the geometry of the box and is sensitive to the model used. As a consequence of compressible formulation, we capture pressure wave-packets with associated reflection and rarefaction from the non-periodic walls. The pattern and frequency of reflections of pressure waves noted specifically at the initial stages are reflected in entropy variation of the system.

42 ENGINEERING↗

Analysis of laboratory data on ultrasonic monitoring of permeability reduction due to biopolymer formation in unconsolidated granular media

We show how to estimate the fluid permeability changes due to accumulated biopolymer within the pore space of a granular material using laboratory measurements of overall permeability, together with various well-known quantitative measures (e.g., porosity, specific surface area, and formation factor) of the granular medium microstructure. The main focus of the paper is on mutual validation of existing theory and a synthesis of new experimental results. Here, we find that the theory and data are in good agreement within normal experimental uncertainties. We also establish quantitative empirical relationships between seismic and/or acoustic attenuation and overall permeability for these same systems.

58 GEOSCIENCES↗

SU-E-J-140: Simulation Study Using Thermoacoustics to Image Proton Dose and Range in Water and Skull Phantom

Purpose: In this study, thermoacoustic pressure signals generated from a proton beam were simulated in water and currently within a skull phantom to investigate the sensitivity of radioacoustic CT imaging in the brain. Methods: Thermoacoustically generated pressure signals from a pulse pencil proton beam (12, 15, 20, and 27cm range) were simulated in water. These simulated pressure signal are detected using a (71) transducer array placed along the surface of a cylinder (30cm × 40cm) and rotated over 2π (in 2 degree increments), where the normal vector to the surface of each transducer intersects the isocenter of the scanner. Currently, a software skull phantom is positioned at isocenter, where the scattering, absorption and speed of dispersion of the thermoacoustic signal through a three layer cortical-trabecular-cortical structure is being simulated. Based on data obtained from the literature, the effects of acoustic attenuation and speed-of-sound (dispersion) will be applied within the 3D FBP algorithm to obtain dosimetric images. Results: Based on hydrophone detector specifications, a 0.5MHz bandwidth and 50dB re 1μPa per Hz^1/2, a 1.6cGy sensitivity at the Bragg peak was demonstrated while maintaining a 1.0 mm (FWHM) range resolution along the central axis of the beam. Utilizing this same information, the integral dose within the Bragg peak and distal edge compared to MC had a 2% (statistical) and 5% voxel-based RMS at this same dose sensitivity. We plan to present preliminary data determining the range sensitivity for a head phantom for this scanner design and the feasibility of imaging the proton dose in patients with a brain tumor undergoing therapy. Conclusion: RACT scanner provides 3D dosimetric images with 1.6cGy (Bragg peak) sensitivity with 1mm range sensitivity. Simulations will be performed to determine feasibility to treat brain cancer patients.

60 APPLIED LIFE SCIENCES↗

Technology Summary L-21044 Tunnel Sensor Hydrogeology Evaluations

Illicit tunneling along the U.S. Mexican border is a persistent national security problem. Several types of sensors could be to used to detect tunnels, but the hydrogeology of the subsurface makes some technologies ineffective. This effort used available borehole and surface geology data to develop 3D hydrogeologic models, which could then provide the input for optimizing subsurface sensor technologies to detect tunnels. Depending on the specific type of sensor, the following physical properties of the subsurface are important: longitudinal speed (velocity-p), shear speed (velocity-s), acoustic attenuation, electrical permittivity, electrical conductivity, density and elastic properties. LLNL developed a procedure which uses hydrogeological datasets to determine 3D hydrogeology cross sections. The physical properties of the rocks are generally not known precisely, thus ranges of properties would need to be considered. This cross-section data can then be utilized to enhance modeling studies to optimize sensor types/systems.

58 GEOSCIENCES↗

Split Hopkinson Resonant Bar Test for Sonic-Frequency Acoustic Velocity and Attenuation Measurements of Small, Isotropic Geologic Samples

Mechanical properties (seismic velocities and attenuation) of geological materials are often frequency dependent, which necessitates measurements of the properties at frequencies relevant to a problem at hand. Conventional acoustic resonant bar tests allow measuring seismic properties of rocks and sediments at sonic frequencies (several kilohertz) that are close to the frequencies employed for geophysical exploration of oil and gas resources. However, the tests require a long, slender sample, which is often difficult to obtain from the deep subsurface or from weak and fractured geological formations. In this paper, an alternative measurement technique to conventional resonant bar tests is presented. This technique uses only a small, jacketed rock or sediment core sample mediating a pair of long, metal extension bars with attached seismic source and receiver - the same geometry as the split Hopkinson pressure bar test for large-strain, dynamic impact experiments. Because of the length and mass added to the sample, the resonance frequency of the entire system can be lowered significantly, compared to the sample alone. The experiment can be conducted under elevated confining pressures up to tens of MPa and temperatures above 100 C, and concurrently with x-ray CT imaging. The described Split Hopkinson Resonant Bar (SHRB) test is applied in two steps. First, extension and torsion-mode resonance frequencies and attenuation of the entire system are measured. Next, numerical inversions for the complex Young's and shear moduli of the sample are performed. One particularly important step is the correction of the inverted Young's moduli for the effect of sample-rod interfaces. Examples of the application are given for homogeneous, isotropic polymer samples and a natural rock sample.

54 ENVIRONMENTAL SCIENCES↗

Resonance-enhanced compact nonlinear acoustic source of low frequency collimated beam for imaging applications in highly attenuating media

Acoustic signal sources include acoustic resonators that include acoustic nonlinear materials. Acoustic signals at higher frequencies are mixed in the nonlinear materials to produce a lower frequency acoustic signal. Resonance provides increased efficiency in producing acoustic signals at difference frequencies corresponding to resonance frequencies. Higher frequency acoustic signals used in nonlinear mixing are preferably at frequencies corresponding to resonance frequencies as well.

Pantea, Cristian↗