Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

(Doublon) Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed, such as the Transient Heatsink Overpower Response capsule (THOR), the Transient Water Irradiation System for TREAT (TWIST), and Sirius. Each has provided valuable data for materials performance and reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments can cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used for code verification, validation and uncertainty quantification. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the verification, validation and uncertainty quantification approach. To overcome this problem, the autocorrected reactimeter algorithm (ACRA) has been developed. This approach infers a time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e., when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for developing an improved version of the ACRA that does not require frozen configurations. To develop this new algorithm, we need a precise and unbiased implementation of the inverse point kinetic equations (IPKEs) as any error in the reactivity evaluation will be propagated into the choice of the optimal spatial correction. Indeed, the previous reactimeter algorithm would use approximations, such as a negligible flux amplitude derivative, to focus on rapidity. For the numerical validation of ACRA, we aim at absolute error under for reactivity derived from signals similar to the one of this study. In this summary, we test eight different IPKE implementations. Each will process a mockup signal built for this study, similar to those that the future ACRA will process. Each reactivity output will be compared to the reference reactivity that has been used to generate the mockup signal. The implementation minimizing the difference with the reference reactivity will be used in the development of a new ACRA formulation.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conformational restriction shapes the inhibition of a multidrug efflux adaptor protein

Abstract Membrane efflux pumps play a major role in bacterial multidrug resistance. The tripartite multidrug efflux pump system from Escherichia coli , AcrAB-TolC, is a target for inhibition to lessen resistance development and restore antibiotic efficacy, with homologs in other ESKAPE pathogens. Here, we rationalize a mechanism of inhibition against the periplasmic adaptor protein, AcrA, using a combination of hydrogen/deuterium exchange mass spectrometry, cellular efflux assays, and molecular dynamics simulations. We define the structural dynamics of AcrA and find that an inhibitor can inflict long-range stabilisation across all four of its domains, whereas an interacting efflux substrate has minimal effect. Our results support a model where an inhibitor forms a molecular wedge within a cleft between the lipoyl and αβ barrel domains of AcrA, diminishing its conformational transmission of drug-evoked signals from AcrB to TolC. This work provides molecular insights into multidrug adaptor protein function which could be valuable for developing antimicrobial therapeutics.

59 BASIC BIOLOGICAL SCIENCES↗

Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed; each has provided valuable data for materials performance, reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used to do verification, validation and uncertainty quantification (VVUQ) on codes. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the VVUQ approach. To overcome this problem, an Autocorrected Reactimeter Algorithm (ACRA) has been developed. This approach infers time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e. when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for the development of an improved version of the ACRA which does not require frozen configurations

22 GENERAL STUDIES OF NUCLEAR REACTORS↗