Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACTIVATION ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Health-care district management information system plan: Review of operations analysis activities during calendar year 1975 and plan for continued research and analysis activities

Operations research activities developed to identify the information required to manage both the efficiency and effectiveness of the Veterans Administration (VA) health services as these services relate to individual patient care are reported. The clinical concerns and management functions that determine this information requirement are discussed conceptually. Investigations of existing VA data for useful management information are recorded, and a diagnostic index is provided. The age-specific characteristics of diseases and lengths of stay are explored, and recommendations for future analysis activities are articulated. The effect of the introduction of new technology to health care is also discussed.

Nielson, G. J.↗

Applications of activation analysis to geochemical, meteoritic and lunar studies.

The application of activation analysis techniques to the analysis of cosmological materials, i.e., terrestrial, tektitic, meteoritic, and lunar matter, is reviewed. Elemental determinations can be made by instrumental fast-neutron and thermal-neutron activation analysis, photonuclear and charged-particle activation analysis, and by radiochemical neutron activation analysis. Partition-coefficient methods, autoradiography studies, gamma-gamma coincidence counting, and age determination by neutron activation are discussed. Attention is given to K-Ar and I-Xe dating of meteorites.

Showalter, D. L.↗

LaBr 3 : Ce self-activation analysis for measuring fast neutron fields

Measurement of the fast neutron production rate in deuterium–tritium (D–T) fusion reactions is important for applications such as active interrogation, fusion diagnostics, and borehole logging. Such measurements are typically performed by neutron activation analysis of metal foils, especially copper. Copper foil activation analysis requires efficiency and energy calibrations of the detector used to measure the foil, and it relies on the detection of 511 keV gamma rays, which are prominent in the active background when neutrons are being produced. Alternatives, such as 79m Br produced by inelastic neutron scattering on 79 Br, are limited by short half-life, low-energy gamma emission, and inability to selectively measure D–T neutrons. This work describes a novel alternative approach to measure ≳10 MeV neutron fields based on self-activation analysis of a LaBr 3 :Ce detector. The activity of 78 Br, the activation product of the 79 Br(n,2n) 78 Br reaction, is used to determine the neutron flux and infer the neutron production rate. We experimentally demonstrate the method with a cylindrical LaBr 3 :Ce crystal with a diameter and height of 3.81 cm that was placed at an ~18 cm distance from the neutron production point, at a 90° angle with respect to the deuteron beam in a D–T neutron generator. Operating voltage and current of the generator were adjusted to evaluate the technique’s performance over a nominal generator output range of approximately (1 - 9) x 10 7 n/s. The neutron output obtained from LaBr 3 :Ce activation agrees to within three standard deviations of the output obtained using copper activation. The self-activation technique can be conveniently employed in a variety of applications to simplify measurements of fast neutrons produced in D–T fusion reactions.

Active interrogationLaBr3↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of radioisotope tracer and activation analysis techniques for contamination monitoring in space environment simulation chambers

Radioisotope measurement techniques and neutron activation analysis are evaluated for use in identifying and locating contamination sources in space environment simulation chambers. The alpha range method allows the determination of total contaminant concentration in vapor state and condensate state. A Cf-252 neutron activation analysis system for detecting oils and greases tagged with stable elements is described. While neutron activation analysis of tagged contaminants offers specificity, an on-site system is extremely costly to implement and provides only marginal detection sensitivity under even the most favorable conditions.

Smathers, J. B.↗

Neutron activation analysis for antimetabolites

Determination of metal ion contaminants in food samples is studied. A weighed quantity of each sample was digested in a concentrated mixture of nitric, hydrochloric and perchloric acids to affect complete solution of the food products. The samples were diluted with water and the pH adjusted according to the specific analysis performed. The samples were analyzed by neutron activation analysis, polarography, and atomic absorption spectrophotometry. The solid food samples were also analyzed by neutron activation analysis for increased sensitivity and lower levels of detectability. The results are presented in tabular form.

Source record↗

Orbital operations study. Volume 2: Interfacing activities analysis. Part 4: Support operations activity group

The findings of the support operations activity group of the orbital operations study are presented. Element interfaces, alternate approaches, design concepts, operational procedures, functional requirements, design influences, and approach selection are presented. The following areas are considered: (1) crew transfer, (2) cargo transfer, (3) propellant transfer, (4) attached element operations, and (5) attached element transport.

Steinwachs, W. L.↗

Nondestructive activation analysis of sample of lunar surface material returned by Luna 16 automatic station

The composition of a sample of lunar surface material returned by the Luna 16 automatic station from the Sea of Fertility was studied, using nondestructive activation analysis. The structure of the returned surface material is inhomogeneous; the surficial material is thin, quite homogeneous, and the granularity increases with depth. Based on grain size, the sample was separated into five zones. The activation analysis was conducted on a sample taken from the friable surficial layer, zone A. The content of Al, Mn, Na, Cr, Co, Fe, and Sc was determined by nondestructive activation analysis of the sample. In determining Cr, Co, Fe, and Sc, the sample was irradiated for 24 hours and cooled for 10 days. Gamma spectra of the samples were recorded with a semiconductor Ge(Li)-detector and a multichannel analyzer, and measurement data were processed with an electronic computer.

Chayko, M.↗