Search NASA⌕ Search

SEARCH · Search NASA

Results for “AERODYNAMIC HEAT TRANSFER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Identifying Characteristics of Wildfire Towers and Troughs

Wildfire behavior is dictated by the complex interaction of numerous physical phenomena including dynamic ambient and fire-induced winds, heat transfer, aerodynamic drag on the wind by the fuel and combustion. These phenomena create complex feedback effects between the fire and its surroundings. In this study, we aim to study the mechanisms by which buoyant flame dynamics along with vortical motions and instabilities control wildfire propagation. Specifically, this study employs a suite of simulations conducted with the physics-based coupled fire-atmosphere behavior model (FIRETEC). The simulations are initialized with a fire line and the fires are allowed to propagate on a grass bed, where the fuel heights and wind conditions are varied systematically. Flow variables are extracted to identify the characteristics of the alternating counter-rotational vortices, called towers and troughs, that drive convective heat transfer and fire spread. These vortices have previously been observed in wildfires and laboratory fires, and have also been observed to arise spontaneously in FIRETEC due to the fundamental physics incorporated in the model. However, these past observations have been qualitative in nature and no quantitative studies can be found in the literature which connected these coherent structures fundamental to fire behavior with the constitutive flow variables. To that end, a variety of state variables are examined in the context of these coherent structures under various wind profile and grass height conditions. Identification of various correlated signatures and fire-atmosphere feedbacks in simulations provides a hypothesis that can be tested in future observational or experimental efforts, potentially assisting experimental design, and can aid in the interpretation of data from in situ detectors.

54 ENVIRONMENTAL SCIENCES↗

Internal energy balance and aerodynamic heating predictions for hypersonic turbulent boundary layers

The elemental equation governing heat transfer in aerodynamic flows is the internal energy equation. For a boundary layer flow, a double integration of the Reynolds-averaged form of this equation provides an expression of the wall heat flux in terms of the integrated effects, over the boundary layer, of various physical processes: turbulent dissipation, mean dissipation, turbulent heat flux, etc. Recently available direct numerical simulation data for a Mach 11 cold-wall turbulent boundary layer allows a comparison of the exact contributions of these terms in the energy equation to the wall heat flux with their counterparts modeled in the Reynolds-averaged Navier-Stokes (RANS) framework. Various approximations involved in RANS, both closure models as well as approximations involved in adapting incompressible RANS models to a compressible form, are assessed through examination of the internal energy balance. There are a number of potentially problematic assumptions and terms identified through this analysis. Here, the effect of compressibility corrections of the dilatational dissipation type is explored, as is the role of the modeled turbulent dissipation, in the context of wall heat flux predictions. The results indicate several potential avenues for RANS model improvement for hypersonic cold-wall boundary-layer flows.

42 ENGINEERING↗

Turbine Aero-Thermal Technologies for 65% Combined Cycle Efficiency (Phase I Final Report)

GE Power (GEP), a division of General Electric Company, performed a gas turbine technology development program that integrated Aerodynamic and Heat Transfer advances as an important and innovative step towards the DOE goal of 65% combined cycle efficiency. Improved efficiency will also contribute towards the reduction in the cost of electricity identified by the DOE for the US through reduced fuel consumption, and through lowering the capital cost of the generating equipment. It is currently predicted that the result of this project will enable 0.40~0.65 pt in combined cycle efficiency improvement. This technology will be directly applicable to gas turbines utilizing coal gasification processes where hydrogen-rich coal-derived synthesis gas is produced with natural gas being the developmental fuel.

03 NATURAL GAS↗

Biophysical impacts of Earth greening largely controlled by aerodynamic resistance

Satellite observations show widespread increasing trends of leaf area index (LAI), known as the Earth greening. However, the biophysical impacts of this greening on land surface temperature (LST) remain unclear. Here, we quantify the biophysical impacts of Earth greening on LST from 2000 to 2014 and disentangle the contributions of different factors using a physically based attribution model. We find that 93% of the global vegetated area shows negative sensitivity of LST to LAI increase at the annual scale, especially for semiarid woody vegetation. Further considering the LAI trends (P ≤ 0.1), 30% of the global vegetated area is cooled by these trends and 5% is warmed. Aerodynamic resistance is the dominant factor in controlling Earth greening’s biophysical impacts: The increase in LAI produces a decrease in aerodynamic resistance, thereby favoring increased turbulent heat transfer between the land and the atmosphere, especially latent heat flux.

54 ENVIRONMENTAL SCIENCES↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems How Mohawk and Velo3Dare Printing the Future of Energy

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

A high temperature Heat Transfer Fluid circulator compressor with wide turn down ratio aerodynamic performance was designed, fabricated and tested for application with high pressure super Critical CO2 fluid capable of temperatures and pressures to >750°C and 25 MPa respectively. The modular system decoupled the drive motor system from an independent compressor shaft to provide thermal isolation between the high temperature compressor shaft and the lower temperature capable motor elements. While the thermal management approach appears to be viable there are potential losses in the secondary cooling flows that need to be taken into account and fine-tuned during operation in order to achieve desired overall system efficiencies. The system was also shown to be viable and dynamically stable throughout the entire operating speed range, thereby validating the overall system configuration and structural design approach used. Finally, while it was not possible to achieve specific PTC-10 test points, the compressor performance tests provide sufficient data to indicate that the compressor has the ability to achieve the required performance in practice. The two key factors affecting compressor design and cost are the maximum expected temperature and pressure. The maximum allowable temperatures for current state-of-the-art (SOA) motor driven compressor technology is limited to of approximately 150-200°C, but inlet temperatures >750 °C may be encountered. While the optimal efficiency of compression is in the transcritical region, some concepts require inlet pressures to 225 bar.

14 SOLAR ENERGY↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Experimental Investigation of Sweeping Jet Film Cooling in a Transonic Turbine Cascade

Abstract The sweeping jet (SJ) film cooling hole has shown promising cooling performance compared to the standard shaped hole in low-speed conditions. The present work demonstrates the first attempt of SJ film cooling at an engine relevant Mach number. An experimental investigation was conducted to study the SJ film cooling on a nozzle guide vane suction surface. A well-established additive manufacturing technique commonly known as stereolithography (SLA) was utilized to design a transonic, engine representative vane geometry in which a row of SJ holes was used on the vane suction surface. Experiments were performed in a linear transonic cascade at an exit Mach number of 0.8 and blowing ratios of BR = 0.25–2.23. The measurement of heat transfer was conducted with the transient IR method, and the convective heat transfer coefficient (HTC) and adiabatic film cooling effectiveness were estimated using a dual linear regression technique (DLRT). Aerodynamic loss measurements were also performed with a total pressure Kiel probe at 0.25Cax downstream of the exit plane of the vane cascade. Experiments were also conducted for a baseline-shaped hole (777-hole) for a direct comparison. Results showed that the SJ hole has a wider coolant spreading in the lateral direction near the hole exit due to its sweeping motion that improves the overall cooling performance particularly at high blowing ratios (BR > 1). Aerodynamic loss measurement suggested that the SJ hole has a comparable total pressure loss to the 777-shaped hole.

Engineering↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

A Hybrid Bulk Algorithm to Predict Turbulent Fluxes over Dry and Wet Bare Soils

Measurements made in the Columbia River basin (Oregon) in an area of irregular terrain during the second Wind Forecast Improvement Project (WFIP2) field campaign are used to develop an optimized hybrid bulk algorithm to predict the surface turbulent fluxes from readily measured or modeled quantities over dry and wet bare or lightly vegetated soil surfaces. The hybrid (synthetic) algorithm combines (i) an aerodynamic method for turbulent flow, which is based on the transfer coefficients (drag coefficient and Stanton number), roughness lengths, and Monin–Obukhov similarity; and (ii) a modified Priestley–Taylor (P-T) algorithm with physically based ecophysiological constraints, which is essentially based on the surface energy budget (SEB) equation. Soil heat flux in the latter case was estimated from measurements of soil temperature and soil moisture. In the framework of the hybrid algorithm, bulk estimates of the momentum flux and the sensible heat flux are derived from a traditional aerodynamic approach, whereas the latent heat flux (or moisture flux) is evaluated from a modified P-T model. Direct measurements of the surface fluxes (turbulent and radiative) and other ancillary atmospheric/soil parameters made during WFIP2 for different soil conditions (dry and wet) are used to optimize and tune the hybrid bulk algorithm. The bulk flux estimates are validated against the measured eddy-covariance fluxes. We also discuss the SEB closure over dry and wet surfaces at various time scales based on the modeled and measured fluxes. Although this bulk flux algorithm is optimized for the data collected during the WFIP2, a hybrid approach can be used for similar flux-tower sites and field campaigns.

54 ENVIRONMENTAL SCIENCES↗

Development of a 300 MWe Utility Scale Oxy-Fuel sCO2 Turbine

A 300 MWe direct-fired supercritical carbon dioxide (sCO2) oxy-fuel turbine is being developed that will burn natural gas-fired, coal syngas and even hydrogen mixtures capable of 1,150ºC turbine inlet temperature at 300 bar. This design will significantly improve the state-of-the-art for thermal efficiency and results in a high-pressure stream of CO2 with 98%+ carbon capture, making the power plant near emission-free and more efficient than Natural Gas Combined Cycle (NGCC) plants with carbon capture. This power plant will be capable of burning coal through gasification and cleanup of the synthesis gas (syngas). sCO2 power cycles are a transformational technology for the energy industry, providing higher efficiency heat source energy conversion for conventional and alternative energy sources. This novel cycle significantly reduces capital costs because of smaller equipment footprints, design modularity, and allows for rapid cyclic load and source following to balance solar and wind energy power swings. Oxy-fuel sCO2 cycles take these advantages even further, utilizing higher firing temperatures, improved efficiency, and simpler carbon capture strategies. This turbine will require cooled turbine nozzles and blades as well as advanced thermal management systems to accommodate these high temperatures. The cooled blade heat transfer correlations required new test programs at higher Reynolds number than air-breathing gas turbines for impingement, serpentine, and pin-fin regions. Novel blade optimization was performed to maximize aerodynamic efficiency, while minimizing cooling flows. A turbine layout was generated utilizing individual combustor cans with cooled liners feeding into a 6-stage axial flow turbine with cooled stator nozzles and turbine blades. The case design and thermal management preliminary design will be described.

Moore, Jeffrey↗

Numerical Investigation of Wall-Cooling Effect on Aero-Optical Distortions for Hypersonic Boundary Layer

Compressible wall-modeled large-eddy simulations of Mach 8 turbulent boundary-layer flows over a flat plate were carried out for the conditions of the hypersonic wind tunnel at Sandia National Laboratories. The simulations provide new insight into the effect of wall cooling on the aero-optical path distortions for hypersonic turbulent boundary-layer flows. Four different wall-to-recovery temperature ratios, 0.3, 0.48, 0.71, and 0.89, are considered. Despite the much lower grid resolution, the mean velocity, temperature, and resolved Reynolds stress profiles from the simulation for a temperature ratio of 0.48 are in good agreement with those from a reference direct numerical simulation. The normalized root-mean-square optical path difference obtained from the present simulations is compared with that from reference direct numerical simulations, Sandia experiments, as well as predictions obtained with a semi-analytical model by Notre Dame University. Here the present analysis focuses on the effect of wall cooling on the wall-normal density correlations, on key underlying assumptions of the aforementioned model such as the strong Reynolds analogy, and on the elevation angle effect on the optical path difference. Wall cooling is found to increase the velocity fluctuations and decrease the density fluctuations, resulting in an overall reduction of the normalized optical path distortion. Compared to the simulations, the basic strong Reynolds analogy overpredicts the temperature fluctuations for cooled walls. Also different from the strong Reynolds analogy, the velocity and temperature fluctuations are not perfectly anticorrelated. Finally, as the wall temperature is raised, the density correlation length, away from the wall but inside the boundary layer, increases significantly for beam paths tilted in the downstream direction.

42 ENGINEERING↗

Laser Measurements and Modeling of Shock Tunnel Freestream Velocity and Multispecies Thermal Nonequilibrium

Coherent anti-Stokes Raman scattering (CARS) and nitric oxide molecular tagging velocimetry (NO-MTV) were used to characterize the freestream in Sandia’s Hypersonic Shock Tunnel (HST) using a burst-mode laser operated at 100 kHz. Experiments were performed at nominal freestream velocities of 3 and 4 km/s using both air and N 2 test gas. The CARS diagnostic provides nonequilibrium characterization of the flow by measuring vibrational and rotational temperatures of N 2 and O 2 , which are compared to NO temperatures from separate laser absorption experiments. Simultaneous, collinear freestream velocities were measured using NO MTV along with pitot pressure measurements. Furthermore, this extensive freestream dataset is compared to nonequilibrium CFD that is capable of modeling species-specific, vibrational temperatures throughout the nozzle expansion. Significant nonequilibrium between vibrational and rotational temperatures was measured at each flow condition. N 2 exhibits the most nonequilibrium, followed by O 2 and NO. The CFD model captures this trend, although it consistently overpredicts N 2 and O 2 vibrational temperatures. At 3 km/s, the modeled NO nonequilibrium is underpredicted, whereas it is overpredicted at 4 km/s. Good agreement is seen between CFD and the velocity and rotational temperature measurements. Experiments with water added to the test gas yielded no discernable difference in vibrational relaxation.

Aerodynamics↗

Hard x-ray methods for studying the structure of amorphous thin films and bulk glassy oxides

High-energy photon diffraction minimizes many of the corrections associated with laboratory x-ray diffractometers, and enables structure factor measurements to be made over a wide range of momentum transfers. The method edges us closer toward an ideal experiment, in which coordination numbers can be extracted without knowledge of the sample density. Three case studies are presented that demonstrate new hard x-ray methods for studying the structure of glassy and amorphous materials. First, the methodology and analysis of high-energy grazing incidence on thin films is discussed for the case of amorphous In 2 O 3 . Additionally, the connectivity of irregular InO 6 polyhedra are shown to exist in face-, edge- and corner-shared configurations in the approximate ratio of 1:2:3. Secondly, the technique of high-energy small and wide angle scattering has been carried out on laser heated and aerodynamically levitated samples of silica-rich barium silicate (20BaO:80SiO 2 ), from the single phase melt at 1500 C-o to the phase separated glass at room temperature. Based on Ba-O coordination numbers of 6 to 7, it is argued that the although the potential of Ba is ionic, it is weak enough to cause the liquid-liquid immiscibility to become metastable. Lastly, high-energy small and wide angle scattering has also been applied to high water content (up to 12 wt.%) samples of hydrous SiO 2 glass quenched from 1500 C-o at 4 GPa. An increase of Si 1 O 2 correlations at 4.3 angstrom is found to be consistent with an increase in the population of three-membered SiO 4 rings at the expense of larger rings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Wind Loading on CSP Collectors Caused by Turbulent Wind Fluctuations: Insights from a 2-Year Field Campaign

Concentrating Solar Power (CSP) is a promising solar technology for electricity generation with thermal energy storage and with the additional benefit of industrial heat production. Wind loading on CSP collector structures, such as parabolic troughs or heliostats, is one of the primary drivers of their structural design costs. In particular, dynamic wind loading is a major source of uncertainty in the collector design process, which heavily relies on wind tunnel testing. In the field, the turbulent nature of the incoming wind creates fluctuating loads (support structure loads and resulting mirror deflections) on the collectors, with impacts on fatigue lifetime and optical performance. As is well known, wind tunnel tests cannot entirely reproduce the complex turbulent wind conditions typically observed at full-scale plants. To shed light on this topic, NREL initiated a field campaign at the operational Nevada Solar One (NSO) powerplant that uses parabolic troughs as solar collectors. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs. We use the published 2-year dataset of high-resolution combined wind and structural loads measurements [1] to characterize the dynamic structural wind response. For quantifying dynamic wind loading, we apply the concept of admittance functions, which are spectral transfer functions that couple the turbulent wind to resulting structural loads (aerodynamic admittance), and to the structural response (mechanical admittance). In practice, aerodynamic admittance describes which turbulent eddy sizes are effective in creating structural loads. The mechanical admittance describes in which frequency ranges these loads are reinforced or dampened by the structure. While these functions are an established concept in civil engineering, their recent application to a single full-scale heliostat [2] proved their broader applicability to CSP collectors. Here, we present a characterization of admittance functions for full-scale parabolic trough collectors and show how wind characteristics (mean wind speed and direction, turbulent kinetic energy, turbulent length scales), the sun-tracking trough angle, and row position alter the admittance functions. Further, we study to which extent the admittance functions are universal for a specific trough geometry and how our findings compare to reported heliostat results. References [1] https://data.openei.org/submissions/5938. [2] Blume, K., Roger, M., and Pitz-Paal, R. 2023b. "Simplified analytical model to describe wind loads and wind-induced tracking deviations of heliostats." Solar Energy, 256, 96-109. https://doi.org/10.1016/j.solener.2023.03.055.

admittance functions↗

Meteorological Conditions and Atmospheric Components Concentration in Urban Sites in Knoxville, USA. 2024

This dataset, which contains five csv files, reports several meteorological conditions such as temperature, wind speed, solar radiation, and net radiation measured in Cumberland Estates Park (CEP) and Socially Equal Energy Efficient Development (SEEED) sites in Knoxville, Tennessee, USA. Also, hourly concentration of particulate matter (PM) with different aerodynamic diameter and inorganic gases such as ozone and nitrogen dioxide measured in the two are included in this dataset. The concentrations of PM and inorganic gases were monitored using the MODULAIR, a low-cost sensor equipped with a solar power module. The measurement of the concentration of biogenic and anthropogenic volatile organic compounds (VOCs) of the two sites was determined using a High-Resolution Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). The VOCs were collected using miniature canister (400 mL) equipped with female RAVEqc valve to 1/4” male compression fitting and an integrated passive air sampling kit. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

54 ENVIRONMENTAL SCIENCES↗