Development of safety requirements for HTGRs design - 18467

The safety requirements for the design of High Temperature Gas-cooled Reactors (HTGRs), which is analogous to the IAEA specific safety requirements (SSR) for Light Water Reactor (LWR) design (IAEA SSR-2/1), has been developed by the research committee established in the Atomic Energy Society of Japan so as to incorporate the HTGR safety features demonstrated by High Temperature Engineering Test Reactor (HTTR), lessons learned from the accident of Fukushima Daiichi Nuclear Power Station and requirements for the coupling of the hydrogen production plants with nuclear plant. The safety design approach was determined to establish a high level of safety design standards by utilizing inherent safety features of HTGRs. The safety requirements is then developed using the objectives provisions tree methodology based on the safety design approach. The requirements for a structural integrity of fuel during accident conditions, for a confinement structure instead of a leak-tight pressure resistance containment vessel, for a passive residual heat removal from outside of reactor pressure vessel, etc., which are significantly different from those of LWR, are stated in the developed safety requirements. This paper describes overview of the proposed HTGR specific safety requirements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Research and Experiment on the Key Technologies of the Spent Fuel Storage in HTR-PM - 18486

High Temperature Reactor demonstration project of China (HTR-PM) is one of the major national science and technology projects, some key technologies for the design and operation of the demonstration project are formed to research according to the main technology. The spent fuel storage system is one of the main systems of the HTR-PM. In order to solve the technical problems related to the operation of spent fuel, several experiments have been conducted, including: spent fuel loading, getting back, spent fuel canister hoisting, storage well cover hoisting, storage canister drop and so on. In the study process, the test facility has been set up to carry on the operation and the experiment verification to ensure the reliability and safety of the spent fuel storage system. Spent fuel storage system undertakes spent fuel receiving, spent fuel canister transfer, storage, lifting and other functions in HTR-PM, the project research need to solve several major technical problems related to the spent fuel operation, which mainly include: Develop the transportable spent fuel canister for HTR-PM, the canister is corrosion resistance, impact resistance, and is in subcritical condition when loaded with fuel. Develop the spent fuel canister hoister, which could hoist the spent fuel canister safely and reliably. Develop the spent fuel storage well cover hoister, which could hoist the well cover safely and reliably. Study the small probability of the spent fuel canister in extreme condition of canister hoist falling accidents, to ensure the radiation protect safety and residual heat removal safety of the canister in case of the canister drop when lifting. Develop the spent fuel charging device and return device, which could load the spent fuel elements into the spent fuel canister, and could take out the fuel elements from the canister. The key technology and equipment of the spent fuel storage system in HTR-PM would be solved through the research of the project. Project research is very important for the implementation and safe operation of the HTR-PM project. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Analysis of FFTF Loss-of-Flow Tests with SAS4A/SASSYS-1

The Fast Flux Test Facility (FFTF) was the most recent Sodium-cooled Fast Reactor (SFR) built in the United States. The Passive Safety Test (PST) program was carried out on FFTF between 1984 and 1986 to demonstrate the capability of passive reactor shutdown and decay heat removal in response to protected and unprotected transients. In order to recover the information and knowledge that has been gained from FFTF, a research project was initiated focusing on the simulation of Unprotected Loss of Flow Without Scram (LOFWOS) tests similar to the knowledge preservation activities conducted for EBR-II by Argonne National Laboratory in earlier years. These knowledge preservation activities are intended to support the validation of computational tools and methods in the area of SFR passive safety. Comparisons with experimental data and other safety codes provide opportunities to improve SFR design and safety analysis codes and methods.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Containment margins in FFTF for postulated failure of in-vessel post-accident heat removal

This study was performed to complete the assessment of potential melt-through consequences for the postulated failure of post-accident heat removal following a hypothetical core disruptive accident (HCDA) in the FFTF. The SPRAY, SOFIRE, CACECO, HAA-3B, and COMRADEX codes were used to determine potential site boundary radiation doses. Parametric comparisons were made to evaluate the effects of natural hydrogen-oxygen recombination, reactor cavity liner failures and containment coolers. Containment pressure relief, vent/purge options, and the effects of exhaust filtration were also included in the study. The potential site boundary radiation exposures for all options considered were within 10 CFR 100 guideline values.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Robotic Underwater Decontamination Services for Nuclear Applications-18464

Successful Underwater Robotic Decontamination Demonstrates Dose-Saving And Outage-Shortening Technology Diakont successfully provided underwater robotic decontamination services on a North American nuclear power plant's refueling cavity and dryer-separator pool in Spring 2017 using a new tool system. Historically, nuclear plant operators have conducted cleaning and decontamination of these surfaces manually, after draining water from the space. However manual decontamination is slow, and can result in excessive personnel dose exposure. The underwater robotic decontamination services present a vast improvement over manual decontamination because it reduces personnel dose exposure, reduces radwaste, doesn't impact plant chemistry, and doesn't risk inadvertently spreading contamination. Also the new decontamination method avoids the risk of personnel injury and component damage associated with hydrolasing. And by performing the decontamination robotically while the cavities are flooded, in many cases the critical path outage schedule can be shortened. Able to decontaminate horizontal, vertical, and curved surfaces, the decontamination tools easily navigate to areas within flooded cavities that are inaccessible to previous solutions, performing decontamination in parallel to other activities including fuel movement. Also, unlike other legacy solutions, the new tools do not require continuous use of an overhead crane or other method of suspension while performing the decontamination activities. The ROV-type decontamination tool attaches and drives along the cavity and component surfaces using a high-force, no-flow vortex generator, even in the presence of Residual Heat Removal (RHR) or shutdown cooling flow. Efficient, effective cleaning is performed using a rugged brushing action to detach the crud, while vacuuming it away at high flow rates to a submerged filter. At the Spring 2017 refueling outage, the decontamination services with the new methodology were so effective that no additional manual cavity decontamination was required after drain-down. Using the tool's ability to swim, attach, and crawl, field technicians decontaminated the majority of the surfaces designated by the plant operator. Preliminary surveys indicated that all contamination levels were reduced to <50 K dpm/100 cm{sup 2}, helping the utility meet their INPO/Industry collective radiation exposure goals. The new cleaning and decontamination services are ideal for servicing various underwater areas within nuclear power plants such as refueling cavities, BWR-6 drywell heads, spent fuel pools, cask loading pools and fuel transfer canals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on the heat removal for fuel debris using heat pipes

Simple method to retrieve fuel debris by meta-stabilizing: Heat removal system is needed. Heat removal using heat pipes: Cover fuel debris with geopolymer. What is a heat pipe: Heat transport medium with cycles of evaporation and condensation. It consists of the container, working fluid, and the wick. Advantage: Internal vacuum structure, small amount of working fluid, Massive heat transfer due to high-speed movement of hydraulic fluid. Cycle of hydraulic fluid with capillary structure. Because the cycle works independently of gravity, we can set heat pipes at free angle. We evaluated the availability of heat pipes within PCV. Investigation of hydrogen and oxygen concentration of internal gas collected by water replacement method: Non-condensable gas was confirmed inside the heat pipe irradiated by gamma rays. The heat removal effect by the heat pipe greatly descends to the extent close to the copper pipe by Gamma ray irradiation. The above reason was presumed to be that non-condensable gas was generated by radiolysis and the active length of the condensation part of the heat pipe decreased. Counter measures to decrease the amount of non-condensable gas is necessary for using heat pipes under radiation environment. We are doing the experiments to check changes in non-condensable gas generation by using catalysts or other kinds of liquids under Gamma ray irradiation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual System Design of a Supercritical CO{sub 2} cooled Micro Modular Reactor - 18492

Small modular reactor (SMR) concepts proposed in the past have compact size and a longer life reactor core than the conventional nuclear power plants. However, previous concepts based on the water-cooled technologies with a steam Rankine cycle have shown that the complete modularization is still technically challenging. This study suggests an innovative concept of a reactor directly cooled by supercritical carbon dioxide (S-CO{sub 2}) with S-CO{sub 2} Brayton cycle as a power conversion system, namely KAIST MMR (Micro Modular Reactor). To enhance neutron economy and maximize the fuel volume fraction of the core, a uranium carbide fuel controlled by drum type control rods was used in the fast-spectrum MMR. The core has long life (20 years) without refueling or reshuffling as well as inherent safety features. The reactor can be used as a distributed power source, and replace outdated fossil fuel power plants for small cities. Moreover, we propose a S-CO{sub 2} Brayton cycle as a power conversion system to achieve small, high performance and lightweight module. Thanks to the compact core and power conversion system, the entire system can be contained in a single module. The target of the system is to achieve small and compact system that can be transported via ground transportation of a single module containing the core and the power conversion system altogether. In order to meet this target single module s total weight is minimized in the order of 150 tons. The external size of a module is less than 7 m in length and 4 m in diameter. It produces 12 MWe electricity from 36 MWt reactor core. The S-CO{sub 2} Brayton cycle was optimized, and the cycle components were designed while maximizing the performance and minimizing the weight. A passive decay heat removal system utilizing shell and tube heat exchangers was also developed, and examined its performance with transient analysis code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Orificed Flow Results for a Two-Phase Natural Circulation Loop

Researchers at University of Wisconsin - Madison have constructed a 1/4 scaled experimental facility to study the operation of a two-phase natural circulation decay heat removal system. The Reactor Cavity Cooling System (RCCS) is a decay heat removal safety system designed for high temperature generation IV reactors. The system removes decay heat by encircling the outside of the walls of the pressure/containment vessel with cooling channels. These channels are filled with either air in an open loop configuration or water in a closed loop configuration. Radiative and convective heat loads from the pressure vessel induce a buoyancy driven flow in the risers. In accident conditions, the water-based system reaches saturation and the resulting steam is vented off further removing heat until the water inventory is depleted. The water based system has been under investigation at University of Wisconsin - Madison for variations in performance under various flow restriction cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow Characteristics of Intermediate Heat Exchanger with CFD Methodology on Nuclear Safety Application

The intermediate heat exchanger (IHX) plays an important role in the field of nuclear power plant, and its safety margin could strongly affected by the flow distribution of secondary flow inlet. As a result, the size of secondary inlet is crucial in thermal design. However, the IHX contains thousands of heat exchanger tubes, and it takes larger time to simulate each tube accurately. Other than that, there are more delicate devices in a nuclear power plant, so it would take too much time to simulate actual model. Although system code could solve problems effectively, it could not detect local deformation. On nuclear safety application, how to save time and receive specific results in an efficient way is necessary. Therefore, the porous media model and the heat exchanger model from computational fluid dynamics (CFD) were adopted in this study. The methodology not only can save much time than actual model but also receive more specific results than system code. To ensure the accuracy, validation of the methodology is also presented in this study by modeling RHR heat exchanger of L nuclear power plant. The results of the simulation were compared to experimental values from L nuclear power plant and receive small errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Analysis of the Passive Residual Heat Removal System of an Integral Reactor

A demand for small modular reactors (SMRs) is gradually emerging worldwide, especially in Middle East Asia and Africa. SMART (System-integrated Modular Advanced ReacTor) developed by KAERI (Korea Atomic Energy Research Institute) is the first mover among several SMRs. It is designed to produce 100 MW of electricity, or 90 MW of electricity and 40,000 tons of desalinated water concurrently, which is sufficient for 100,000 residents. SMART is currently holding the initiative as the first licensed integral reactor in the world since 4 July 2012, when the standard design approval (SDA) was officially issued by the Nuclear safety and security commission (NSSC). After that, the SMART safety enhancement project was successfully conducted with intense support of the Government, resulting in an in-depth development of the most advanced safety features including the passive residual heat removal system (PRHRS). Recently, an agreement between KAERI and King Abdullah city for atomic and renewable energy (K.A. CARE) was officially signed for the pre-project engineering (PPE) in pursuit of the construction of SMART and developing human resources capability. Both parties are currently conducting a three-year preliminary study to review the feasibility of building SMART and to prepare for its commercialization. KAERI also takes responsibility to train R and D personnel chosen from Kingdom of Saudi Arabia. Sooner or later, SMART will open the global market of SMR and be the best competitive pioneer. Since the Fukushima accident, the passive cooling system of a nuclear reactor has received a great amount of attention. SMART is designed with passive systems in order to ensure the safety of the reactor. The PRHRS is one of the passive safety systems, which is activated after an accident to remove the residual heat from the core and the sensible heat of the reactor coolant system (RCS) through the steam generators (SGs) until the condition of the RCS reaches a safe shutdown condition. In the present study, the thermal performance of the PRHRS is predicted by using in-house code. Temperature of the RCS and the cooling rate of the RCS are traced with time to see if it is satisfactorily designed to meet the design requirements of the PRHRS. The dependency of the mass flow rate of the natural circulation on the filling ratio (FR) is also discussed. The FR is arbitrarily chosen from 0.22 to 0.50 and further parametric study is needed in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The ATWS analysis of the HTR-10GT core induced by the earthquake - 18489

The 10 MW High Temperature Gas Cooled Test Reactor (HTR-10) has been built in Institute of Nuclear and New Energy Technology (INET) and has been operating successfully since the beginning of 2003. The core outlet temperature of HTR-10 is 700 deg. C. To verify the technology of gas-turbine direct cycle, at first INET had a plan to increase its core outlet temperature to 750 deg. C and use a helium gas turbine instead of the steam generator (then the reactor is called HTR-10GT). Though HTR-10 has good intrinsic safety, the design basic accidents and beyond design basis accidents of HTR-10GT must be analyzed according to China s nuclear regulations due to changed operation parameters. THERMIX code system is used to study the Anticipated Transient Without Scram (ATWS) caused by an earthquake. The gravity acceleration of the earthquake will make the porosity of the pebble bed smaller, which will thus induce a positive reactivity. The packing fraction of the HTR-10GT core will increase to 0.64 from 0.61, while a reactivity of 1.24% will be inserted into an initial core and 0.788% for an equilibrium core. Then the reactor power increased and the temperature of the core increased. When the neutron flux of power measuring range exceeded 123% and the reactor period becomes less than 20 seconds, the reactor should scram. It was supposed that all the control rods in the reflectors had been blocked and the reactor could not scram. Thus the accident went on and the core temperature and the system pressure increased but the reactor shutdown at last because of its natural negative temperature reactivity feedback mechanism. The residual heat would be removed out of the core by the cavity cooling system. During the accident sequence the maximum fuel temperature was 1223 deg. C. If a temperature coefficient error of 20% was considered during analyzing, the peak temperature of the fuel during the ATWS will reach 1266 deg. C. It was a little higher than 1230 deg. C --the fuel temperature limitation of HTR-10. Now the sphere fuel used in HTR-10GT will also be used in HTR-PM and the temperature limitation has been raised to 1620 deg. C, so the HTR-10GT is safe during the ATWS caused by an earthquake. The paper also compares the analysis result of HTR10-GT to those of HTR-10. The results shows that the HTR-10GT is still safe during the accident though its operating temperature is higher than HTR-10. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Understanding and Controlling Cesium Loading on Crystalline Silicotitanate - 19601

Savannah River Remediation (SRR) contracted with Westinghouse Electric Corporation (WEC), Columbia Energy and Environmental Services (CEES), to build and deliver a modular ion exchange process that will be used to remove radioactive cesium from dissolved salt solution contained in Tank 10 at the Savannah River Site (SRS). The resulting decontaminated salt solution will be sent to Tank 11 and then to Tank 50 for final disposition in grout at the Saltstone facility. At the end of processing, the loaded ion exchange (IX) columns are drained, rinsed, and dried. The IX columns are removed from the modular unit and stored at Interim Safe Storage (ISS). This ion exchange process is called the Tank Closure Cesium Removal (TCCR) system. The TCCR system consists of several unit operations and process monitoring capability housed within three modular units. The first modular unit contains the process control computer, the second modular unit contains the main process equipment (two prefilters, four IX columns, and resin trap (post filtration)), and the third modular unit is the ventilation system. The main unit operations of the TCCR system are filtration, ion exchange, and ventilation. The ion exchange media utilized is a form of inorganic Crystalline Silicotitanate (CST), IONSIV{sup TM} R9120-B supplied by UOP Honeywell. CST has a high selectivity for cesium (Cs) and has some affinity for other Group IA alkali metals on the periodic chart (hydrogen, lithium, sodium, potassium, rubidium, and francium). CST has also been shown to have affinity for strontium and actinides. Cesium loading on the CST is dependent on many factors including chemical composition (cations and anions), temperature, and pH of the salt solution. The actual amount of Cs loaded onto an IX column is dependent on the factors above along with the salt solution volume fed to the IX column. Because of CST's high selectivity for Cs, the Cs-137 equilibrium loading can contribute enough decay heat to result in an ion exchange column boiling event under no flow conditions in the IX column. The boiling event under no flow is a safety concern that must be prevented from occurring. To prevent boiling of the column under no flow conditions, the Cs-137 equilibrium loading must be determined and understood. Several methodologies were evaluated for performing the Cs-137 equilibrium loading determination for CST. After review of available research and development (R and D), batch equilibrium contact test data, and Zheng Anthony Miller (ZAM) model predictions for the salt solution chemistry in Tank 10, a methodology for determining the Cs-137 equilibrium loading on CST was selected. The methodology selected involves an in-tank batch equilibrium contact test performed in duplicate that considers additional corrections to account for anticipated operational evolutions. The in-tank batch equilibrium contact test utilizes ∼0.1 grams of CST secured in a slotted sample vial. The slotted sample vial design allows for salt solution to be in contact with the CST. The slotted sample vials containing the CST are submerged in Tank 10 and exposed to the salt solution for ten days. After ten days, the samples are retrieved and sent to the Savannah River National Laboratory (SRNL) for analysis of the Cs-137 equilibrium loading. Additional corrections are then made to the Cs-137 results to account for anticipated operational evolutions. Anticipated operational evolutions include external additions (water/caustic) to Tank 10 that result in a change to its chemical composition, tank temperature effects, departures from the laboratory testing (mixed vs. stagnant tank conditions), and IX column flushes. A description of the methodologies considered, feasibility of methodology deployment, and the down select process (benefits vs. risks) is discussed in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Empirical Correlation for Condensation Heat Transfer Coefficient of Air-Steam Mixture on a Vertical Tube

The Passive Containment Cooling System (PCCS) provides passive means to remove the decay heat and protect the integrity of the containment during severe accidents. For thermal design and performance evaluation of the PCCS condensers, one needs experimental data and a heat transfer model for condensation heat transfer in the presence of a noncondensable gas on a vertical tube. The main objective of this study is to propose a new empirical correlation, based on the experimental data obtained in Jeju National University, expressed in terms of dimensionless numbers. Dimensionless numbers to account for vapor-gas condensation phenomena are found by non-dimensionalizing the governing boundary layer equations, and the predictions of the proposed correlation is validated with selected sets of experimental data. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of a Passive Endothermic Reaction Cooling System

Passive reactor core cooling systems can mitigate the effects of station blackout conditions and avoid accidents similar to what occurred at the Fukushima Dai-ichi reactors. Advanced nuclear reactor designs such as the Advanced Heavy Water Reactor (AHWR) and others include passive cooling systems. The AHWR utilizes water storage tanks that can remove decay heat for more than 50 days after station blackout. While these systems do not rely on electricity, they do rely on passive valves to function during an emergency situation. The purpose of the present work is to determine the feasibility of a passive endothermic reaction cooling system (PERCS). The PERCS relies on an endothermic reaction that does not proceed until it reaches a threshold temperature. Thus, a vessel filled with chemicals that undergo an endothermic reaction can be directly connected to the reactor core without any valves and only react once accident conditions raise the temperature past the threshold temperature. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LOCA Analysis for the NIST Research Reactor

The research reactor (aka NBSR) at the National Institute of Standards and Technology (NIST) is a heavy water cooled, moderated, and reflected tank-type research reactor that operates at atmospheric pressure and a design power of 20 MW. Core power is generated in 30 fuel elements, each with 17 fuel plates in an upper section and a separate lower section. Power is removed using forced convection and heat exchangers in the cooling loop. The licensing analysis of the loss-of-coolant accident (LOCA) in the NBSR was addressed in the current Safety Analysis Report (SAR). The SAR discusses the low probability of a significant pipe break: 'the main piping is located in protected areas, system pressures are low, and flow rates are small so that wear is not an issue.' Therefore, the probability of a large break, including a double-ended guillotine break, is extremely low. For smaller breaks where the operator has time to take action, procedures are in place to 1) mitigate a loss of water by tripping pumps and closing control valves to isolate the reactor vessel after the falling water level in the vessel is detected by instrumentation, and 2) ensure that emergency cooling water continues to flow for as long as needed. The SAR also refers to an analysis of why there is sufficient water without forced cooling to cool the fuel elements (FEs) in a LOCA if the flow channels between two fuel plates (or a fuel plate and an outside plate) remain filled with water. That analysis was based on a flooding-limited critical power but assumed that reactor trip had taken place. A more recent study showed that some scenarios may lead to the draining of water from the coolant channels. In these cases, the cooling on the inside of the fuel element is from emergency cooling water that falls only along the inner surface of one of the side plates in the fuel elements; the remaining surfaces within the fuel element being exposed to gas. The analysis therein was done for both the present high-enriched uranium fuel (HEU) and the proposed low-enriched uranium fuel (LEU). The LOCA analyses done previously assumed that there is sufficient cooling during the short-term, i.e., before the water level reaches the top of the fuel plates and begins to drain from the coolant channels or before decay heat becomes low enough such that the flooding-limited critical power shows that there is no problem. The present study is to determine if that assumption is correct, i.e., to consider the situation immediately after the break, before and after reactor trip when the power is still relatively high.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantification of functional impact classification on the current U.S. nuclear fleet

Currently, nuclear power generates only a small fraction of the world's electricity, though it does have the potential to meet the needs of the world as long as its production can compete with the alternative energy base load producers. In U.S the commercial nuclear fleet comprises of Light Water Reactors (LWRs), consisting of Pressurized Water Reactors (PWRs) and Boiling Water Reactors (BWRs). Many plants experience multiple events each year, which lead to reactor trips or scrams. This subsequently leads to plants being off the grid, which is not an economically favorable situation in the current energy markets. This study helps identify functional impact (FI) event categories for both PWR's and BWR's. Understanding that not all events and their causes can be anticipated, current industry best practices implement lessons learned to provide challenges and issues identification. In turn these are studied to achieve improved operational practices, and design modifications. This leads to overall enhanced resiliency. FI groups are the categories of initiating events (IE). IEs are unplanned events that occur while a nuclear plant is in critical operation, and requires that the plant be shut down to achieve a stable state. When a risk cannot be eliminated, IEs are identified and studied to reduce the risk and contribute to the identification of mitigations, safer designs and operational practices. Breaking IE events into groups' results in the classification of FI groups. A FI group is a risk-significant event category that could impact the ability of a NPP to remove decay heat from the reactor. Inability to remove decay heat from the reactor has the potential to lead to core damage. For an event to be considered a FI, it must be associated with a manual or automatic reactor trip, irrespective of the order of events. In addition, the plant must be at or above the point of adding heat and the event must happen before or shortly after a reactor trip. One or more FIs may be identified in any individual reactor trip sequence. The relationship between FI sequence, and/or frequency per a plant event is outside the scope of this paper. For example, the loss of offsite power (LOOP) can occur from eternal events (i.e. weather, human, wildlife etc.). This results in an event that requires a transfer of power to an emergency source, such as a generator, which produces a reactor trip and then a closure of main steam isolation valves (MSIVS). The FI applicable to this reactor trip sequence would be LOOP and closure of at least one MSIV in each main steam line. The results presented herein are focused on the analysis and evaluation of FI event categories. Only FI categories that can be found in IE studies, Initialing Events Spreadsheet and are recorded in a historical review of Licensee Event Reports (LERs) from 1988 through 2013. The results of this analysis can support plant decisions, design, procedures, and identify weakness.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Molten Salt Reactor Simulations using MPACT-CTF

The US Department of Energy and industry have shown significant interest in advanced reactors, as evidenced by over 1.3 billion dollars of private investments in companies to develop advanced reactor concepts. More than seven of these advanced reactor concepts use molten salt reactor (MSR) technology. Based on this interest in MSR technology, ORNL has invested in the development of the MSR simulation capability, extending some capabilities in VERA to model this high-profile reactor concept. In this paper, the MPACT deterministic neutron transport capability and the COBRA Two-Fluid (CTF) subchannel capability are adapted to handle liquid fuel MSRs. Specifically, this work focuses on modifications to the depletion algorithms to account for isotopic mixing, continuous feed, and continuous removal. Models will be added to account for drift of precursors and decay heat emitters as the liquid fuel flows through the reactor coolant system. Modifications to CTF, including the addition of molten salt properties, are also addressed. Finally, the coupled MPACT-CTF capability is used to simulate the 30-year operation of an MSR.