Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quaternary ammonium salt coated air filter for bioaerosol removal from building indoor air

Developing air filters with biocidal ability is important to protect the public from infectious respiratory diseases. A simple spray-coating approach was devised to fabricate antimicrobial air filters to remove bioaerosols. Here, the commercial antimicrobial agent Goldshield 75 was coated on the air filters through covalent immobilization, endowing the fabricated filter with long-lasting biocidal ability. All coated filters significantly inhibited both Gram-positive bacteria (Micrococcus luteus) and Gram-negative bacteria (Escherichia coli). The antibacterial ability of the coated filters is similar to the commercial AeraSafe antibacterial filter. The coated filter showed over 99.9 % antibacterial efficiency 3 months after the application of the coating. Both bacterial and virus filtration efficiencies of coated charged polypropylene filter were higher than 99.9 %. The coating did not have much effect on the NaCl aerosol filtration efficiency of the filters. This simple spray-coating strategy is a practical method for producing antimicrobial air filters for the prevention of infectious respiratory diseases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gross Alpha Beta Radioactivity in Air Filters Measured by Ultra Low Level alpha/beta Counter

Study of radioactivity in air as very important for life is done regularly using different methods in every country. As a result of nuclear reactors, atomic centrals, institutions and laboratories, which use the radioactivity substances in open or closed sources, there are a lot radioactive wastes. Mixing of these wastes after treatment with rivers and lakes waters makes very important control of radioactivity. At the other side nuclear and radiological accidents are another source of the contamination of air and water. Due to their radio toxicity, especially those of Sr{sup 90}, Pu{sup 239}, etc. a contamination hazard for human begins exist even at low concentration levels. Measurements of radioactivity in air have been performed in many parts of the world mostly for assessment of the doses and risk resulting from consuming air. In this study we present the results of international comparison organized by IAEA Vienna, Austria for the air filters spiked with unknown Alpha and Beta Activity. For the calibration of system we used the same filters spiked: a) with Pu-239 as alpha source; b) Sr-90 as beta source and also the blank filter. The measurements of air filter samples after calibration of the system are done with Ultra Low Level alpha/beta Counter (MPC 9604) Protean Instrument Corporation. The high sensitivity of the system for the determination of the Gross Alpha and Beta activity makes sure detection of low values activity of air filters. Our laboratory results are: Aalpha = (0.19+-0.01) Bq/filter and Aalpha(IAEA) = (0.17+-0.009) Bq/filter; A{sub b}eta = (0.33+-0.009) Bq/filter and A{sub b}eta (IAEA) = (0.29+-0.01) Bq/filter. As it seems our results are in good agreement with reference values given by IAEA (International Atomic Energy Agency).

54 ENVIRONMENTAL SCIENCES↗

Novel rapid oxidizing fusion method to determine Polonium-210 in air filters

A rapid method for the determination of polonium-210 in air filters has been created for use following a radiological event and for routine environmental monitoring. Air filter samples, including cellulose and glass fiber, are fused with a sodium or potassium nitrate/sodium hydroxide flux material. The alkaline matrix minimizes polonium volatility during sample digestion steps, while efficiently dissolving the air filter and inorganic matter implanted on the filter. The addition of nitrate to the flux destroys organic material which can decrease Polonium recovery during precipitation, extraction and source preparation steps. Polonium is concentrated and separated from the sample matrix using an iron hydroxide precipitation and extraction chromatography with DGA Resin. Polonium-210 is subsequently measured by alpha spectrometry following rapid microprecipitation with bismuth phosphate. The new method employs extraction chromatographic purification to remove alpha emitting interferences and sample matrix constituents which can interfere with 210 Po measurements using alpha spectrometry. The novel blend of sodium hydroxide and alkali metal nitrate digests the air filters quickly and effectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES

A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

54 ENVIRONMENTAL SCIENCES↗

Effect of Intake Air Filter Condition on Light-Duty Gasoline Vehicles

Proper maintenance can help vehicles perform as designed, positively affecting fuel economy, emissions, and the overall drivability. This effort investigates the effect of one maintenance factor, intake air filter replacement, with primary focus on vehicle fuel economy, but also examining emissions and performance. Older studies, dealing with carbureted gasoline vehicles, have indicated that replacing a clogged or dirty air filter can improve vehicle fuel economy and conversely that a dirty air filter can be significantly detrimental to fuel economy. The effect of clogged air filters on the fuel economy, acceleration and emissions of five gasoline fueled vehicles is examined. Four of these were modern vehicles, featuring closed-loop control and ranging in model year from 2003 to 2007. Three vehicles were powered by naturally aspirated, port fuel injection (PFI) engines of differing size and cylinder configuration: an inline 4, a V6 and a V8. A turbocharged inline 4-cylinder gasoline direct injection (GDI) engine powered vehicle was the fourth modern gasoline vehicle tested. A vintage 1972 vehicle equipped with a carburetor (open-loop control) was also examined. Results reveal insignificant fuel economy and emissions sensitivity of modern vehicles to air filter condition, but measureable effects on the 1972 vehicle. All vehicles experienced a measured acceleration performance penalty with clogged intake air filters.

air filters↗

Chemical and structural characterization of particulate fallout isolated from air-filters

We report particulate nuclear fallout is the radioactive byproduct of a nuclear event formed by the mixture of proximate environmental materials with vaporized bomb debris. The fallout debris can be transported into the atmosphere during cloud rise, raining out locally and dispersing globally constituting a radiation hazard and contributing to the distribution of anthropogenic radionuclides in the environment. Questions remain on how entrainment of environmental material in the fireball affects fallout formation processes and radionuclide incorporation and distribution during cooling. To inform the characterization of fallout including the development of fallout size distributions and how radionuclides are incorporated into fallout debris where entrainment plays a role, we analyzed an archived historic US air-filter collected by aircraft in the aftermath of ground interacting nuclear tests. Particulate fallout collected on the filter was isolated and analyzed using scanning electron microscopy (SEM), transmission electron microscopy (TEM) and NanoSIMS (Secondary Ion Mass Spectrometry) to determine chemistry, structure, morphology, and size of the particles. Results demonstrate that the particles isolated from the filter have spherical shape, display complex internal structures, and are mainly composed of Fe and Si oxides. In these spherical particles, Pu is preferentially associated with Fe-rich composition. The characterization of fallout particulate samples can provide information on nucleation and particle growth from the vapor phase to improve modeling and simulation of fallout hazards.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The iSERIES™ radon progeny compensation algorithm and its application to air filters

Sandia has developed methods to perform a rapid count using Canberra’s iSERIES™ Alpha/Beta Counting System, the iSOLO™. The purpose of this report is to show that by using the iSERIES™ built-in radon progeny compensation algorithm, the radon progeny-free gross alpha air concentration can be determined for a sample taken using a high volume air sampler or a lapel device within a few hours post-sampling. Also, a special form of the Currie Minimum Detectable Activity estimation was derived for use with the radon progeny stripping algorithm after it was discovered that the expression used by the Canberra software did not take the counts due to radon progeny into consideration as part of the background. This rapid air sample analysis proves to be a vast improvement to the current method that has an average turn-around time between seven and ten days.

Fournier, Sean Donovan↗

Prototype Ceramic High Efficiency Particulate Air Filter Testing and Filter Media Development for Nuclear Facility Ventilation

This report summarizes recent and past related Ceramic HEPA Filter activity for this NNSA NSR&D project and on-going plans for FY18 and FY19 work as presently planned. Prior work has evaluated concepts for a ceramic HEPA filter including ceramic support materials, filter media including electrospun filter media, and metal housing designs to accommodate the conservative temperature performance target of up to 500°C. This has been supported by modelling efforts discussed with nuclear facility system engineers and their management. The temperature and time-at-temperature are based on conservative, bounding temperatures from fire analysis presented as a draft EFCOG best practice paper for nuclear facility safety analysis. The overall goal is to improve safety of DOE nuclear facilities during fire scenarios by developing improved filtration technology including increasing performance while reducing pressure drop. Ceramic filtration technology can provide robust, passive mitigation against radiological releases. The goal of the ceramic HEPA filter is to provide a robust HEPA filter that provides increased temperature performance in an equivalent form factor (size and shape) that is similar to existing conventional HEPA filters used in facilities. Once qualified for use in facilities, the benefit of a ceramic HEPA filters could simplify and reduce safety and support system costs, as well as considerably lower life-cycle costs. Installation, monitoring, and maintenance of active fire suppression systems, as well as other related systems, are a considerable on-going cost to nuclear facilities. Reducing the level of dependence on Safety Class and Safety Significant fire alarm and fire suppression systems could allow significant cost savings. At present we are continuing research and development efforts towards the goal of a ceramic filter design, including improved ceramic filter media, that could reduce total operation cost for facilities utilizing HEPA filters.

42 ENGINEERING↗

Statistical Analysis of Low Flow Filter Efficiency Testing Results for Nuclear Material Storage Container Filters

Air filters designed to contain plutonium particulates while allowing hydrogen gas to escape are used in a variety of low flow rate applications in the nuclear industry. Examples include nuclear material storage containers, glove box bag-out bags and waste drums. Filter efficiency testing is essential to ensure filter performance, and yet the low testing flow rates present some challenges because the testing flow rates can be 5 to 6 orders of magnitude lower than those used to test large HEP A filter systems used in facility ventilation systems. Statistical analysis of low flow filter efficiency test results on nuclear material storage container filters has proven to be essential to ensure that the testing processes, test equipment, and filters meet the design requirements. This poster will describe the testing apparatus used to test nuclear material storage container filters and the use of statistical methods to analyze low flow filter efficiency test results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities

Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.

60 APPLIED LIFE SCIENCES↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Radiological/biological/aerosol removal system

An air filter replacement system for existing buildings, vehicles, arenas, and other enclosed airspaces includes a replacement air filter for replacing a standard air filter. The replacement air filter has dimensions and air flow specifications that allow it to replace the standard air filter. The replacement air filter includes a filter material that removes radiological or biological or aerosol particles.

54 ENVIRONMENTAL SCIENCES↗