Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR INLET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effects of Inlet Area Ratio on Operability of an Axial Air Inlet Rotating Detonation Combustor

This research presents the first results from a new Rotating Detonation Combustor (RDC) design with an axial air inlet and rear-facing angled fuel injection. This design features a variable air inlet that allows for the study of the effect of inlet area ratio on operation and to directly study the coupling between the air plenum and channel of the RDC while minimizing inlet pressure losses. This device maintains the same downstream channel configuration as those previously tested in our laboratory, which includes a 154 mm outer channel diameter and a constant area channel with a width of 7.6 mm. All tests were completed with a downstream hydrogen-air afterburner capable of flashing back in the channel to initiate detonation operation. Initial tests demonstrated successful operation at air mass flow rates from 160 to 770 g/s and equivalence ratios from 0.53 to 1.05 at multiple air inlet to channel area ratios, indicated that sensors installed within the air feed plenum are able to characterize the dynamic characteristics of waves within the detonation channel, and verified that the design goals for this configuration were achieved.

Shepard, Joshua↗

Energy and Environmental Analyses of a Solar–Gas Turbine Combined Cycle with Inlet Air Cooling

Sensitivity to ambient air temperatures, consuming a large amount of fuel, and wasting a significant amount of heat dumped into the ambient atmosphere are three major challenges facing gas turbine power plants. This study was conducted to simultaneously solve all three aforementioned GT problems using solar energy and introducing a new configuration that consists of solar preheating and inlet-air-cooling systems. In this study, air was preheated at a combustion chamber inlet using parabolic trough collectors. Then, inlet air to the compressor was cooled by these collectors by operating an absorption cooling cycle. At the design point conditions, this novel proposed integration resulted in a 6.87% relative increase in generated power and a 10.53% relative decrement in fuel consumption, achieving a 19.45% relative increment in the plant’s thermal efficiency. This was accompanied by a reduction of 0.026 kg/s, 4.2 kg/s, and 0.278 kg/s in CO 2 , CO, and NOx emissions, respectively. Finally, spider diagrams were employed to assess the impact of the operating parameters on the overall system’s performance and its associated environmental implications.

14 SOLAR ENERGY↗

Mixing and detonation structure in a rotating detonation engine with an axial air inlet

High-fidelity simulations of an experimental rotating detonation engine with an axial air inlet were conducted. The system operated with hydrogen as fuel at globally stoichiometric conditions. Instantaneous data showed that the detonation front is highly corrugated, and is considerably weaker than an ideal Chapman–Jouguet wave. Regions of deflagration are present ahead of the wave, caused by mixing with product gases from the previous cycle, as well as the injector recovery process. It is found that as the post-detonation high pressure flow expands, the injectors recover unsteadily, leading to a transient mixing process ahead of the next cycle. The resulting flow structure not only promotes mixing between product and reactant gases, but also increases likelihood of autoignition. These results show that the detonation process is very sensitive to injector design and the transient behavior during the detonation cycle. Phase-averaged statistics and conditionally averaged data are used to understand the overall reaction structure. As a result, comparisons with available experimental data on this configuration show remarkable good agreement of the predicted reacting flow structure.

42 ENGINEERING↗

Design and Testing of a Water-Cooled Rotating Detonation Combustor at Elevated Operating Pressures - Abstract

This is an extended abstract being submitted for consideration that briefly describes the material that will be included in the final paper. This study will detail the design and testing of a water-cooled Rotating Detonation Combustor (RDC) that permits operation for extended periods of time ensuring that the device has reach a stable operating temperature. Extended run times also provides an opportunity to consider transient behaviors that occur as a result of altering the operating conditions such as equivalence ratio. The experimental setup is also unique in that it consists of a ducted exhaust with a downstream high-temperature valve that can control the pre-combustion pressure in the RDC independent of the combustor annulus and exit geometry. This paper will examine the results from the extended operation of the water-cooled RDC over a range of both transient and steady state equivalence ratios (0.5 - 1.0), pre-combustion operating pressures (0 - 207 kPa), mass flow rates (0.42 – 0.5 kg/sec) and air inlet throat area to combustor channel area ratios (0.09 – 0.32). All tests were performed while operating on hydrogen in air at a nominal air inlet temperature of 340 – 350 K. Limited data obtained at an elevated inlet air temperature of 480 K will also be discussed. Results suggest that under certain conditions the operating mode of the detonation wave can vary as it approaches a stable operating temperature. For the RDC tested, a stable operating temperature is not achieved until approximately 8-10 seconds of run time.

Ferguson, Donald↗

Dynamic study of direct CO 2 capture from indoor air using poly(ethylenimine)-impregnated fiber sorbents

Supported amine adsorbents are promising materials for direct air capture (DAC) of CO 2 due to their high CO 2 capacity and relatively low energy requirement for regeneration. For a DAC process, it is essential to properly define operating parameters to achieve high sorbent productivity (amount of CO 2 captured per unit quantity of sorbent material over unit time). It is furthermore essential to understand the kinetic behavior of the process under the influence of various operating conditions such as the inlet air velocity, sorbent composition, and humidity to select an effective range of operating conditions to maximize sorbent productivity. Here, the dynamic behavior of a DAC process is probed using a fixed fiber sorbent contactor containing poly(ethylenimine) (PEI)-impregnated composite silica/cellulose acetate (CA) fibers. Throughout this study, experiments are conducted using both simulated air (398 ppm CO 2 balanced by N 2 ) and real indoor air (~400–500 ppm CO 2 ). The experimental behavior of the fibers using simulated air and indoor air is compared, and the influence of the inlet air velocity on the breakthrough behavior is assessed. By changing operating conditions, the impact on the fiber sorbent productivity (mmol CO 2 g fiber –1 h –1 ) is quantified to identify conditions that could favor high rates of CO 2 removal. The kinetics of steam-assisted CO 2 desorption are studied, identifying achievable desorption times. Productivities of 1.2 mmol CO 2 g fiber –1 h –1 are obtained using an inlet air velocity of 1.1 m s –1 . Performance trends show that further increasing the inlet air velocity will likely lead to even higher productivities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elevated Inlet Temperature Effects on the Operation of a Rotating Detonation Combustor

This experimental work explores the impact of elevated inlet temperatures on a H2/air operated rotating detonation combustor (RDC) without a nozzle. In practical systems, the temperature of the inlet air would be higher than that found in many laboratory settings. Inlet air pre-heating up to 480 K was accomplished by using an integrated pebble-bed heater. The operation of the RDC was found to switch from a single detonation wave at ambient temperature to two, counter-rotating detonation waves at higher temperatures for some of the conditions tested. In addition, the detonation wave properties (i.e., speed and pressure ratio) were impacted by the elevated inlet temperature. The cause of the observed changes in the operation dynamics was explored by evaluating the existence of secondary waves prior to the operational mode change and the changes in the cycle-averaged inlet Mach number.

Feleo, Alexander↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗

Enhanced Air-Cooling System with Optimized Asynchronously-Cooled Thermal Energy Storage

A transformative dry-cooling system that includes two primary dry-cooling components has been developed in this project. The two main features of this new technology consist of: (a) an ultra-enhanced air-cooled condenser (ACC), with novel swirl-producing and boundary-layer disrupting enhanced surface on the air-side of the condenser that substantially increase the heat transfer coefficients, and (b) a novel daytime peak-load shifting system that reduces the ambient air inlet temperature for air cooling, consisting of a highly compact and enhanced air pre-cooler that transfers the heat load to a unique thermal energy storage (TES), and which is coupled to the ACC in (a).

20 FOSSIL-FUELED POWER PLANTS↗

Enhanced cooling tower technology for power plant efficiency increase and operating flexibility

The Final Report describes the results of the work completed during the “Enhanced Cooling Tower Technology for Power Plant Efficiency Increase and Operating Flexibility” project. The objectives of work were to develop and demonstrate the prototype (up to 100 kWth) of an economically viable “all weather” Sub-Dew Point Cooling Tower (SDPCT) with inlet air cooling and dehumidification including testing in laboratory-controlled environment for simulating various ambient conditions. The inlet air is cooled and dehumidified by a Pressure Dehumidifying System (PDHS) installed at the cooling tower inlet.

20 FOSSIL-FUELED POWER PLANTS↗

Fluidization of Group A Glass Particles: Experiments and Preliminary Validation

This work is aimed at providing reliable high-quality data from fluidization experiments. Geldart Group A glass beads are used as bed material. The fluidizing medium is air at atmospheric pressure which enters the system at 40% relative humidity. The air inlet velocity is varied over a broad range from 2 U mf to 26 U mf , where the minimum fluidization velocity, U mf , is 0.608 cm/s. There is not a significant change in the mean values of differential pressure; however, there are noticeable trends in their standard deviation values. Preliminary validation studies are performed using the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). The results from Eulerian-Eulerian (MFiX-TFM, two-fluid model) and Eulerian-Lagrangian (MFiX-PIC, particle-in-cell) formulations are compared. The work presented in this report highlights the applicability of MFiX-PIC for large-scale applications, and reveals that PIC simulation offers a suitable alternative to TFM simulation when effects due to multiple components or polydispersity are significant. PIC modeling provides a readily extendible framework for such systems. However, PIC models do rely on an empirical closure for inter-particle stress. Some solution discrepancies were evident in MFiX-PIC predictions which require further analysis. As such, the study underlines the need for a systematic approach to quantify the sources of numerical uncertainty within the PIC model. However, even with known empiricism, MFiX-PIC has demonstrated considerable potential in analyzing gas-solid systems. The results obtained are encouraging and warrant further investigation to improve the predictive capability of MFiX-PIC.

36 MATERIALS SCIENCE↗

A Method to Design and Optimize Axial Flow Cyclones for Gas–Liquid Separation

This article provides a detailed design guide, optimization, and performance assessment for air–water separation of an axial flow cyclone. Axial flow cyclones (also known as swirl tube demisters, mist eliminators, or Austin–Write cyclones) have a range of applications in several different industries. This method of gas–liquid separation offers many benefits. Among these are high liquid separation efficiencies (near 99%) and an inline design that allows them to be more easily fitted into existing piping structures. Despite these benefits, there are several design parameters that have not been optimized for performance in wastewater purification applications. This research fills the gap in the literature by quantifying the effect of new design parameters on water collection efficiency, η water collection , and the air bypass efficiency, η air bypass , defined as the ratio of the air mass flowrate exiting through the desired air outlet over the inlet air mass flowrate. A set of wide-ranging experiments were conducted to study the effects of gas–liquid flow rates, tube geometry, and relative injection angles to optimize the water collection and air bypass efficiencies. The water collection efficiency exceeded 99.8% when the liquid streamline came in direct contact with the water drainage exit. An empirical correlation was developed to predict the swirl pitch as a function of the above design parameters. Predictions from the correlation were within 10% of the experimental results. The correlation can be used to design highly efficient in-line gas–liquid separators.

Engineering↗

Spark-ignited direct-injection engine combustion systems

A direct-injection stratified charge internal combustion engine includes a combustion cylinder to receive an air-fuel mixture, and an air intake port to inlet air into the combustion cylinder. The direct-injection engine also includes a fuel injector configured to deliver fuel within the cylinder in a spray pattern substantially aligned to a cylinder central axis to create the air-fuel mixture. A spark igniter is located within a path of the spray pattern to ignite combustion of the air-fuel mixture. The direct-injection engine further includes a movable piston defining a lower boundary of the combustion cylinder to contain the combustion of the air-fuel mixture. The piston is configured to include a bowl portion having local geometric features located on an intake port side of the combustion cylinder to redirect fluid flow towards a vortex in fluid communication with a combustion location near the cylinder central axis.

42 ENGINEERING↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Pressure Gain, Stability, and Operability of Methane/Syngas Based RDEs Under Steady and Transient Conditions (Final Project Report)

The scope of this work addresses key issues associated with losses associated with the detonation wave and other processes internal to the RDE operation, as well as it develops modeling tools for the evaluation of these losses and exhaust emissions in RDEs. The main challenge in studying RDEs is that RDE performance is highly reliant on the specifics of the design so much so that simple/canonical systems alone cannot provide useful engineering information, but practical RDE designs are sufficiently complex and involve extreme operational environments that detailed access either experimentally (laser diagnostics, for instance) or computationally (direct numerical simulations) are as yet to become practical. To overcome this challenge, we have conducted a combined experimental/simulation/analytical study investigating key phenomena that control the characteristics of operation of RDEs. As a result, the study has developed tools and methods that can be used to evaluate performance and design approaches using reduced-physics models, with the assumptions validated using detailed simulations, and the model prediction tested using experimental observations. The specific objectives of the research were: (1) Develop and demonstrate a low-loss fully axial injection concept, taking advantage of stratification effects to alter the detonation structure and position the wave favorably within the combustor; (2) Obtain stability and operability characteristics of an RDE across operating conditions to aid in the development of operability and performance rules for the operations of other systems; and (3) Develop quantitative metrics for performance gain as well as quantitative description of the loss mechanisms through a combination of diagnostics development, reduced-order modeling, and detailed simulations. The work conducted here has made contribution on design of low-loss inlets that has broad application within the power generation industry for use with pressure gain combustion. The operability and stability of different designs, while focusing on axial air inlet designs, has been analyzed. The effect of nozzle and injection conditions was studied. Models and simulations of exhaust emissions, focusing on NOx emission has been developed and used to investigate how operation of the RDE affect NOx production using Lagrangian analysis of RDE simulations. This work has built on previous programs, with the goal of further understanding operation of RDEs and elevate the readiness of design consideration. In addition, a suite of diagnostic and modeling tools have been developed to obtain quantitative metrics on performance based on measurements, which can be readily transferred to other experimental configurations.

08 HYDROGEN↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Prediction of Detonation-Induced Disturbances Propagating Upstream into Inlets of Rotating Detonation Combustors

Disturbances caused by the detonation wave in a rotating detonation combustor (RDC) propagate upstream through the inlet, and can potentially affect and couple to upstream components, such as turbomachinery or isolators. These disturbances can potentially also affect the operation of the RDC itself. By drawing from the analogy of a detonation wave bounded by an inert gas, the pressure disturbances observed upstream of the inlet are explained as the consequence of the passage of an upstream propagating oblique shock. In this study, the pressure rise in the plenum from the oblique shock is measured in an axial air inlet RDC. The speed of the upstream propagating wave is estimated to be moderately above the acoustic speed of the oxidizer in the plenum. The wave propagates into the plenum despite local regions of choking in the inlet. It is estimated that the time it takes a fluid particle to transit from the plenum to the detonation channel through the inlet is much larger than the rotational time of the detonation wave. This implies that a fluid particle experiences multiple shocks prior to entering the detonation channel. The oblique shock propagating upstream through the inlet area change is modeled by leveraging an analogy with a quasi-1D shock wave moving in a variable area duct with mean (incoming) flow. Due to flow expansion along the area change, fluid particles are found to experience stronger shocks in the inlet than in the plenum, thereby creating different thermodynamic states within the fill region as the oxidizer emerges from the inlet.

Feleo, Alexander↗

Technoeconomic assessment of distillation heat transfer intensification using aeroelastically fluttering reeds

Dry cooling, where forced air is the heat transfer medium, is a preferable cooling method in arid locations lacking readily available process water. However, such locations often experience high ambient temperatures that limit the effectiveness of air cooling. The objective of this study is to quantify the economic and energetic benefits of heat transfer intensification via the implementation of aeroelastically fluttering reeds to the air-cooled condenser of a methanol distillation column. Condenser size and performance, regarding recovered methanol and required fan power, is evaluated across condenser operating temperatures (T cond ) from 60 to 62°C and heat transfer coefficients (U) U base –2U base for a range of inlet air temperatures based on ambient temperature data from Yuma, Arizona. Under typical design sizing, condenser capital cost was reduced by 6%–35% (1.3U base –2U base ) and nominal methanol recovery was increased from 0.26% to 0.38% (T cond = 62–60°C). At optimized condenser size, all enhanced U and T cond pairs increase methanol recovery and reduce fan power costs compared to the optimal Ubase reference. Overall, using enhanced heat transfer to maintain condenser temperature under a wider range of inlet conditions, rather than to reduce operation temperature, produces more favorable performance. Methanol price is not a determining factor in which pairs are profitable. Analysis was repeated for a global warming scenario, revealing more valuable improvements under elevated temperatures. Energy savings from condenser improvement to a methanol production system are not significant with respect to an optimized conventional system. Furthermore, unit economic and energetic incentives suggest implementation of fluttering reeds may be justified in other applications.

42 ENGINEERING↗