Search NASA⌕ Search

SEARCH · Search NASA

Results for “ALARM SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Next ALarM System

NALMS is an alarm system application designed for availability, integrability, and extensibility. The NALMS development was driven by SLAC's efforts to replace the Alarm Handler, due for deprecation as a Motif-based application, and to introduce process improvements addressing hierarchy implementation overhead, limited operator engagement, and operator display integration.

Garrahan, Jacqueline↗

Report for 2.2.1 Task 5: Develop and Document a State-Based Alarm System for a Nuclear Power Plant Control Room Using Machine Learning. Light Water Reactor Sustainability Program report

In legacy control rooms the operators might have 20 to 30 alarms to deal with on 12 control boards, during a reactor trip. The new digital alarm system in the upgraded control room will display between 150 and 200 alarm points on a single screen. This overload of information prevents the operators from identifying any abnormal alarms quickly without having to scroll through the alarm list looking for the abnormal alarms. One way to tackle this problem could be to attempt to create a state-based alarm system which would identify plant states and would identify which alarms are expected in those states and suppress them from the alarm screen so that any unexpected alarms would be displayed and easily identified to the operators. This can be done today but is very labor intensive in that an operator or training instructor would be required to run scenarios and log the alarms to be suppressed. The hope is that Machine Learning (ML) can provide an alternative solution with less manual effort required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality, for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other functional requirements specified in ANSI/ANS-8.3.1997, are not included in the test. Routine and periodic maintenance and calibrations performed at Y-12 and AWE are intended to provide adequate confirmation for meeting these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Smart Alarm System for the CEBAF Injector

RadiaSoft and Jefferson Laboratory are working together to develop a machine-learning-based smart alarm system for the CEBAF injector. Because of the injector’s large number of parameters and possible fault scenarios, it is highly desirable to have an autonomous alarm system that can quickly identify and diagnose unusual machine states. We present our work on artificial neural networks designed to identify such undesirable machine states. In particular, we test both auto-encoders and inverse models as possible tools for differentiating between normal and abnormal states. These models are being developed using both supervised and unsupervised learning techniques, and are being trained using CEBAF injector data collected during dedicated machine studies as well as during regular operations. Lastly, we discuss tradeoffs between the two types of models.

Abell, D. T.↗

CS-Studio Alarm System Based on Kafka

The CS-Studio alarm system was originally based on a relational database and the Apache ActiveMQ message service. The former was necessary to store configuration and state, while the latter communicated state updates and user actions. In a recent update, the combination of relational database and ActiveMQ have been replaced by Apache Kafka. We present how this simplified the implementation while at the same time improving performance.

Kasemir, Kay↗

Qualification of Y-12 Legacy Criticality Accident Alarm System Detectors

The Y-12 National Security Complex has had a criticality accident alarm system (CAAS) capable to detect a criticality accident since 1945. With the exception of Y-12’s new High-enriched Uranium Materials Storage facility (HEUMF), the system installed in Y-12’s existing facilities dates to 1957. This legacy system has received many upgrades since installation and detector stations have been removed and relocated as enriched uranium operations have evolved, but the basic design and electronic configuration of the system is the same as that in 1957.

61 RADIATION PROTECTION AND DOSIMETRY↗

Criticality Acccident Alarm System (CAAS) CSG-UM Hybrid Example

Criticality Accident Alarm System calculations combine methods needed for both criticality and shielding calculations. UM may be used for facility details, allowing import of existing facility drawing. CSG used for criticality cells.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Criticality Accident Alarm System Modeling for the Uranium Processing Facility

The Criticality Accident Alarm System (CAAS) for the Uranium Processing Facility (UPF) provides coverage for two primary processing facilities. For UPF, detailed documentation and drawings of the design are readily available. While this design information allows for some CAAS modeling features to match the actual design with a high level of accuracy, assumptions and simplifications are necessary as it is unrealistic and unnecessary to replicate many aspects of the design. A set of modeling guidelines and techniques were used to develop consistency between the MCNP6 models. While ensuring conservatism, overly conservative choices must be avoided to demonstrate the minimum accident of concern can be detected. To ensure proper modeling choices were made for the final models, a group of parametric studies were performed to evaluate the impact on the dose rates detected at the individual detectors. Some of these modeling choices and/or associated parametric studies include: - Modeling the grid steel area above the detectors as homogeneous stainless steel and determining the impact on detectability with an increasing density. - Modeling the presence of equipment in close proximity to the CAAS detectors. - Determining an appropriate material density to represent miscellaneous items not specifically modeled. - Evaluating the impact of sprinkler activation. The results of UPF CAAS analyses show that the modeling assumptions made based on the detailed design and parametric studies are appropriate and demonstrate accurate yet conservative models have been developed for detecting minimum accident of concern within the UPF.

61 RADIATION PROTECTION AND DOSIMETRY↗

Criticality Alarm Systems at the Idaho Chemical Processing Plant

The Idaho Chemical Processing Plant (ICPP) has a number of criticality alarm systems (CAS) in the various facilities. The complexity of the plant creates some unique CAS problems. A detailed review of the CAS has been made to determine the level of compliance with ANSI 8.3-1986. A major CAS upgrade project is currently in the design stage which will expand coverage and bring all CAS monitoring unshielded areas into full compliance with ANSI 8.3-1986. Because DOE Orders do not contain an exclusion that exempts the need for CAS coverage in shielded areas as provided in ANSI 8.3-1986, a future CAS upgrade project is in the planning stage which will also upgrade the CAS coverage in shielded portions of the plant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Basis for the Uranium Processing Facility Criticality Accident Alarm System

The technical basis for the Y-12 National Security Complex (Y-12) Uranium Processing Facility (UPF) Criticality Accident Alarm System (CAAS) 90% design has been completed. The CAAS design was evaluated for two primary processing facilities, the Main Processing Building (MPB) and the Salvage and Accountability Building (SAB), and for connected facilities known as the Personnel Support Building (PSB) and the Highly Enriched Uranium Materials facility (HEUMF) Connector (HCON), which connects UPF to existing Y-12 facilities. The evaluation focused on three primary areas to address requirements of ANSI/ANS-8.3: (1) detectability of the minimum accident of concern; (2) determination of areas where total dose could exceed 12 rad for the maximum anticipated accident yield; and (3) evaluation of the radiation tolerance of the detectors and associated control cabinets. The design was based on extensive analyses performed in MCNP6.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Event Response and Criticality Alarm Systems [Slides]

The smallest accident, in terms of fission yield and dose rate, that a criticality alarm system is required to detect. Need for a CAS shall be evaluated for all activities in which the inventory in individual unrelated areas exceeds 700g U-235, 500g U-233, 450 g Pu-239 OR 450g of any combination of these three isotopes. Unique configurations exist such that critical mass requirements may be less than the limits noted above.

61 RADIATION PROTECTION AND DOSIMETRY↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Final Report for the Testing of the Y-12 Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor (IER-443)

This report documents the experimental conditions and final results for the performance testing of the Y-12 Criticality Accident Alarm System (CAAS) detectors at the Godiva IV Burst Reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The testing followed a previously issued test plan and was conducted during the week of July 17, 2017, with completion on Thursday July 20. The test subjected CAAS detectors supplied by Y-12 to very intense and short duration mixed neutron and gamma radiation fields to establish compliance to maximum radiation and minimum pulse width requirements. ANSI/ANS- 8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates provided by each burst during the test exceeded those requirements. The CAAS detectors all provided an immediate alarm signal and remained operable after the bursts establishing compliance to the requirements and fitness for re-deployment at Y-12.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

UPF and Y-12 Criticality Accident Alarm System (CAAS) Radiation Testing Report

This report documents the experimental conditions and results for the testing of the Mirion Technologies CAAS-3S Criticality Accident Alarm System (CAAS) for the Y-12 National Security Complex (Y-12) and Uranium Processing Facility (UPF). The testing was conducted at the Godiva IV Burst Reactor at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS) during the week of January 11, 2021. The testing was conducted in accordance with 25774-QL-POA-JR00-00002-VDE-27.0, CAAS-3S Radiation Testing of Cabinet Components Test Plan. The tests subjected the CAAS-3S system to intense and short duration mixed neutron and gamma radiation fields and to high integrated radiation doses. The purpose of the test was to environmentally qualify various CAAS-3S components in a radiation environment. Successful completion of the tests was predicated on the collaborative efforts of several organizations. Sandia National Laboratory (SNL) and Lawrence Livermore National Laboratory (LLNL) provided dosimetry to estimate photon and neutron dose. Los Alamos National Laboratory (LANL) manages the NCERC facility, operated the Godiva IV reactor, and provided field support for CAAS-3S placement and communications interface for data acquisition systems supplied by Mirion Technologies. Throughout the test campaign, Y-12 and UPF personnel provided technical support in determining changes to the test schedule, as needed, interpretation of the results, and comparison between the measured dosimetry data and predicted results. Throughout the test campaign, Mirion personnel provided technical support in the operation of the CAAS-3S system itself.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗