Results for “ALPHA SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Monitoring of Actinide Concentrations in Molten LiCl-KCl Salt using Alpha Spectroscopy: Final Progress Report

This project addresses the need for real time monitoring of actinide concentrations for spent fuel reprocessing utilizing alpha spectroscopy. This project specifically focuses on spent fuel reprocessing with the pyroprocessing technique that uses high temperature molten salt. Pyroprocessing uses molten salt such as lithium chloride and potassium chloride to separate out uranium and plutonium from spent fuel. To prevent any possible diversion of high purity plutonium in this process, monitoring of the actinide concentrations within the refinery are essential for safeguards and non-proliferation efforts. Alpha spectroscopy enables the identification and quantification of actinide isotopic concentrations. However, current assay methods involving intrusive sampling and ex-suit measurement require weeks to provide accurate information. A near real-time and in-situ measurement system is required to quickly quantify actinide isotopic concentrations within the salt. Semiconductor radiation detectors provide a compact, high energy resolution option for completing these measurement needs. Silicon carbide (SiC) has been shown to operate effectively at high temperatures and high chemical stability in the molten salt environment. 4H-SiC Schottky diode alpha particle detectors were fabricated and tested to determine their alpha spectroscopy capabilities. The detectors need to operate at the elevated temperatures, survive the molten salt environment, be radiation hard, and have sufficient energy resolution under all these conditions to determine isotopic concentrations. Along with the detector, a method of producing samples of the actinides in the salt is required. To produce a thin film of the actinides on the detector, which is a necessity for alpha spectroscopy, electrodeposition can be used. Electrodeposition uses an electric potential difference to selectively deposit uranium or other actinides from the salt using an anode and cathode. Deposition of the material directly onto the sensor would produce a thin film of material that would enable materials accountability measurements to be taken in real time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Alpha spectroscopy backgrounds at Lawrence Livermore National Laboratory: technical equivalency for backgrounds with blank plates versus backgrounds with no plates

Alpha spectroscopy chamber backgrounds are routinely measured using blank plates. Operator time spent moving blank plates in and out of chambers is significant. If chamber backgrounds are measured in empty chambers, time spent moving blank plates can be reclaimed for other uses. This study compares here results of chamber backgrounds measured with and without plates. Five hundred fourteen chamber backgrounds measured with plates are paired with 514 chamber backgrounds measured without plates. The total counts within 13 spectral regions of interest are compared statistically. Chamber backgrounds measured without blank plates are found statistically equivalent to chamber backgrounds measured with blank plates.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Elevated Temperature Alpha Spectroscopy with Nickel-Platinum {sup 4}H-SiC Schottky Diodes

In order to protect against the diversion of special nuclear material during pyro-processing of spent nuclear fuel, an online monitoring of the actinide concentrations must be developed. In order to do so, alpha spectroscopy can be employed in order to determine the relative concentrations of various isotopes based on the characteristic alpha spectrum of each isotope of interest. The operating temperatures in the pyro-processing environment are such that high temperature operability of alpha detectors is required. The Idaho National Laboratory (INL) electro-refiner operates at a molten salt temperature of approximately 500 deg. C. The vapor temperature above the molten salt is approximately 100 deg. C. In order to provide reasonably compact online monitoring of the actinide concentrations within the molten salt the detector would be located in this vapor region. The temperature in this location is too high for a commercial silicon detector to operate without serious signal degradation due to thermal noise. As the operating temperature increases, the thermal energy available to the charge carriers within the semiconductor increases. For narrow band-gap semiconductors like silicon, this increase in free charge carriers with increasing temperature leads to unacceptable leakage current at relatively low temperatures when compared with wide band-gap materials. In order to overcome this, a wide band-gap material is employed. An alpha particle sensor utilizing a nickel Schottky barrier {sup 4}HSiC wafer was heated to a temperature of 100 deg. C and an alpha spectrum collected. The performance of the sensor at 100 deg. C was compared to the room temperature performance. Molten salts such as those used in the INL electro-refiner exhibit strong corrosive properties. Any sensor which will be exposed to or submerged in the molten salt must have a ruggedized sensor face capable to withstand the corrosive environment. In the contact design utilized in this paper the Schottky barrier forming metal, nickel, is coated with a thin layer of platinum to serve as a corrosion resistant layer. An additional modification to previous designs was the simplification of the Schottky barrier composition. A Schottky barrier is created when a metal is brought into close physical contact with a semiconductor. To first order, the barrier height of the Schottky barrier is a result of the mismatch between the electron affinity of the semiconductor and the metal work function of the metal. In previous iterations, the high temperature performance of the detectors had been limited by diffusion processes between the various metal layers. In order to reduce the likelihood of such a degradation, the Schottky contact structure was simplified without loss of functionality. By replacing the multiple metal layers with a nickel Schottky forming layer capped with a thin platinum layer, the potential degradation of the Schottky barrier height could be reduced, primarily through the similar Schottky barrier height to nickel formed by platinum with SiC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Z{sub 1/2}, EH{sub 5}, and Ci1 deep defects on the performance of n-type 4H-SiC epitaxial layers Schottky detectors: Alpha spectroscopy and deep level transient spectroscopy studies

Spectroscopic performance of Schottky barrier alpha particle detectors fabricated on 50 μm thick n-type 4H-SiC epitaxial layers containing Z{sub 1/2}, EH{sub 5}, and Ci1 deep levels were investigated. The device performance was evaluated on the basis of junction current/capacitance characterization and alpha pulse-height spectroscopy. Capacitance mode deep level transient spectroscopy revealed the presence of the above-mentioned deep levels along with two shallow level defects related to titanium impurities (Ti(h) and Ti(c)) and an unidentified deep electron trap located at 2.4 eV below the conduction band minimum, which is being reported for the first time. The concentration of the lifetime killer Z{sub 1/2} defects was found to be 1.7 × 10{sup 13} cm{sup −3}. The charge transport and collection efficiency results obtained from the alpha particle pulse-height spectroscopy were interpreted using a drift-diffusion charge transport model. Based on these investigations, the physics behind the correlation of the detector properties viz., energy resolution and charge collection efficiency, the junction properties like uniformity in barrier-height, leakage current, and effective doping concentration, and the presence of defects has been discussed in details. The studies also revealed that the dominating contribution to the charge collection efficiency was due to the diffusion of charge carriers generated in the neutral region of the detector. The 10 mm{sup 2} large area detectors demonstrated an impressive energy resolution of 1.8% for 5486 keV alpha particles at an optimized operating reverse bias of 130 V.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Actinide in Air (Rn-Progeny Rejected) Alpha Spectroscopy With Tensioned Metastable Fluid Detectors

Here, this article discusses outcome of research for deriving a methodology and apparatus for ascertaining for the presence of ultratrace-level actinides in air from their alpha emission signatures, while remaining blind to the relatively large (1000× higher activity) alpha emissions from Rn-progeny. Apparatus and techniques were developed to collect and characterize alpha-emitting nuclides of Rn-progeny and actinides in air on a polycarbonate 3 μm pore size continuous air monitor (CAM) filter. A wet-chemistry approach was developed and validated for successfully separating the Rn-progeny alpha emitting isotopes of Po-214 and Po-218, while extracting the actinides (U, Pu, Am) in a fluid mixture that is suitable for conduct of alpha spectroscopy with a centrifugally tensioned metastable fluid detector (CTMFD). The resulting α-TMFD technology was compared against the state-of-art “Alpha-Sentry™” Continuous Air Monitor (CAM) system commonly utilized world-wide. Results indicate that the α-TMFD technology can potentially offer complementary and superior performance in multiple performance categories, and ∼18× improvement in the time to detect (e.g., at 0.02 derived air concentration (DAC) within ∼3 h, versus ∼70 h for Alpha-Sentry) for actinides of interest while also remaining ∼100% blind to ∼10 3 × higher Rn-progeny background—with the added potential for offering few keV scale energy resolution without resorting to peak shape fitting, versus ∼300–400 keV for existing CAM systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-view fast-ion D-alpha spectroscopy diagnostic at ASDEX Upgrade

A novel fast-ion D-alpha (FIDA) diagnostic that is based on charge exchange spectroscopy has been installed at ASDEX Upgrade. The diagnostic uses a newly developed high-photon-throughput spectrometer together with a low-noise EM-CCD camera that allow measurements with 2 ms exposure time. Absolute intensities are obtained by calibrating the system with an integrating sphere and the wavelength dependence is determined to high accuracy using a neon lamp. Additional perturbative contributions to the spectra, such as D{sub 2}-molecular lines, the Stark broadened edge D-alpha emission, and passive FIDA radiation have been identified and can be subtracted or avoided experimentally. The FIDA radiation from fast deuterium ions after charge exchange reactions can therefore be analyzed continuously without superimposed line emissions at large Doppler shifts. Radial information on the fast ions is obtained from radially distributed lines of sight. The investigation of the fast-ion velocity distribution is possible due to three different viewing geometries. The independent viewing geometries access distinct parts of the fast-ion velocity space and make tomographic reconstructions possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison of Laboratory Analytical Methods for Uranium Analysis Superior Steel FUSRAP Site - 16606

The Superior Steel Site processed uranium metal in support of the Atomic Energy Commission's fuel-element development program in the 1950's, and was subsequently classified as a Formerly Utilized Sites Remedial Action Program (FUSRAP) Site. Previous investigations at the site identified uranium contamination both inside and outside the buildings associated with historic uranium metalworking activities. The U.S. Army Corps of Engineers (USACE) is currently engaged in the Remedial Investigation (RI) phase in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980, as amended. As part of the RI, gamma spectroscopy analysis of environmental samples was performed on-site using a laboratory-grade, high-purity germanium (HPGe) spectrometer. The gamma spectroscopy analysis included isotopes of uranium and their progeny. As a quality assurance measure, a subset of samples already analyzed on-site were sent to a certified, commercial, off-site laboratory for analysis using a suite of analytical methods including gamma spectroscopy, alpha spectroscopy, and mass spectroscopy. As an element of the quality assurance program implemented for the RI, an assessment of the correlations between the various analytical methods employed by both the on-site and off-site laboratory was performed. This assessment revealed inconsistencies between on-site and off-site gamma spectroscopy analytical results, which raised concerns about the appropriateness and suitability of the analytical data. To resolve the data quality concerns and better understand the source(s) of analytical results variability, the Superior Steel RI team (USACE together with its contractor, Amec Foster Wheeler) developed a quality control test whose design objective was to control or practically eliminate sampling and sample preparation variability in order to focus more clearly on analytical variability. This paper discusses the results of this supplemental quality control test, showing the differences in the various analytical methods (both on-site and off-site). It demonstrates in a practical and real world setting how sample preparation and analytical variability, if not controlled and understood can impact data quality and data defensibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alpha Coincidence Spectroscopy studied with GEANT4

Abstract The high-energy side of peaks in alpha spectra, e.g. 241Am, as measured with a silicon detector has structure caused mainly by alpha-conversion electron and to some extent alphagamma coincidences. We compare GEANT4 simulation results to 241Am alpha spectroscopy measurements with a passivated implanted planar silicon detector. A large discrepancy between the measurements and simulations suggest that the GEANT4 photon evaporation database for 237Np (daughter of 241Am decay) does not accurately describe the conversion electron spectrum and therefore was found to have large discrepancies with experimental measurements. We describe how to improve the agreement between GEANT4 and alpha spectroscopy for actinides of interest by including experimental measurements of conversion electron spectroscopy into the photon evaporation database.

Dion, Michael P.↗

Perovskite CsPbBr 3 Single Crystal Detector for Alpha-Particle Spectroscopy.

Here we report the first spectroscopic alpha particle detection based on CsPbBr 3 detectors with asymmetric contacts. The CsPbBr 3 single crystal was grown from melt using Bridgman method and then fabricated into detectors with different contacts. The In/CsPbBr 3 /Au detector presented a low dark current (~100 nA/cm 2 ) and temporal stable performance under high electric field (1000 V/cm). Such detector demonstrated excellent gamma ray resolving capability with a full-width at half maximum (FWHM) of ~5.9 keV for the 57 Co 122 keV γ ray. The CsPbBr 3 detector was capable of simultaneously resolving both the alpha particle (5.5 MeV) and γ ray (59.5 keV) peaks from 241 Am radiative isotope. The transport properties of CsPbBr 3 were then determined based on the alpha particle spectra and corresponding rise time distributions. The equivalent values of electron and hole mobilities were indicated as 63 and 49 cm 2 /(V∙s) respectively. The calculated electron and hole mobility-lifetime products were 4.5 x 10 -4 and 9.5 x 10 -4 cm 2 /V, respectively, demonstrating superior transport properties of holes over electrons in CsPbBr 3 . As a result, this work widens the scope of perovskite detectors to encompass charged radiation as well as high energy X/γ rays, and will significantly promote and guide further studies on perovskite materials for radiation detection applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge exchange recombination spectroscopy for {alpha} particles colliding with hydrogen atoms

The intensities of charge exchange recombination spectroscopy (CXRS) of {alpha} particles colliding with the hydrogen atoms in the neutral beam injection (NBI) are calculated by solving the rate equations including electron collision processes in the quasi-static state approximation. The effects of electron collision processes on the CXRS signals for He{sup +}(n=4{yields}3) at {lambda}=468.6nm in various plasma conditions are discussed, and it is found that these effects can increase the CXRS signals by 50% for electron density n{sub e}{>=}10{sup 15}cm{sup -3}. However, their importance decreases with the increasing of NBI energy. For the short pulse of NBI, the influences of electron collision processes can be neglected for n{sub e}{<=}10{sup 14}cm{sup -3}. Furthermore, the spectra of He{sup +}(n{yields}n') are present for the plasma conditions of HT-7 tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deliverable for FαST project: Ln Resin based PLE

This memo describes the fabrication of a polymer ligand extractant based on Eichrom's LN-1 resin. This work has been in support of the Fast Alpha Spectrometry Tool (FαST) project. The first part of LANL's role in this project is to evaluate new extractants for use in polymer ligand extractants (PLEs). The first new extractant evaluated is Di(2-ethyl hexyl) phosphoric acid (HDEHP), which is an effective metal extractant. It has very efficient chelating properties for a wide variety of metal ions. HDEHP is an amphiphillic molecule with two long hydrocarbon chains and a polar end with a phosphoryl oxygen (P=O) and an acidic -OH group as shown in Figure 1. HDEHP has shown effectiveness in extracting lanthanides, selective actinides, and other trivalent elements. Several authors have reported that lanthanides and elements with +3 oxidation state have similar extraction behavior in nitric acid. The distribution ratio for lanthanides rapidly decreases at lower nitric concentration then start to increase at higher concentration as shown in. The trivalent americium, curium, and yttrium exhibit similar trend as trivalent lanthanides. This extraction trend can be also observed from hydrogen chloride solution. This work describes the use of this ligand in a PLE to extract plutonium from solution. Polymer ligand films were prepared by dissolving HDEHP ligands and polystyrene beads in THF. The solution was directly deposited onto a 40 mm diameter stainless steel substrate using an automated pipette. HDEHP based PLEs with direct stippling method are shown in Figure 2. The solution was air dried at room temperature overnight to ensure complete evaporation of THF. The plutonium tracer solution was prepared in 0.01, 0.1, 1, and 8M nitric solutions to study the effect of nitric concentration in plutonium extraction. 0.1667 Bq 239 Pu tracer solution was directly stippled on each PLE and was allowed to equilibrate for 3 hours before removing the solution. The plutonium activity of each sample was measured by direct alpha counting to quantify the plutonium recovery by HDEHP PLE. The alpha spectra from alpha spectroscopy are shown in Figure 3. 1:5, 1:10, and 1:20 PLEs had sharp peak with low tailing. 1:2 had an extremely long tail, which is a possible indication that a large amount of ligands caused the film to not form a smooth surface. Also, it can be noted that 1:2 ratio PLE surface was not as rigid as the other ratio PLEs and it was prone to scratching during sample handing. The resolution of alpha spectra was quantified by measuring Full Width at Half of the Maximum (FWHM) using Bortels equation. The tailing component of the peak was also measured along with FWHM. The peak resolutions and tailing measurements for 0.1M nitric solution samples are given in Table 1. The best resolution was achieved with 1:5 PLE and worst was given by 1:2 PLE. The plutonium recovery by HDEHP PLE was dependent on both nitric concentration and ligand to polymer ratio. 1:2 PLE consistently had the highest recovery followed by 1:5 as shown in Figure 4. It should be noted that 1:2 ratio PLEs consistently had long tailing and the ROI of the spectrum had to be increased to encompass total counts from the tracer. 1:10 and 1:20 PLEs had close to zero percent recovery in all nitric concentration except for 0.01M. The highest plutonium recovery was observed for 0.1M nitric acid. 1:5 PLE gave the best combination of alpha spectroscopy resolution and plutonium recovery. Radiography image of samples were generated to study the plutonium distribution on the PLE surface. Samples were placed on an imaging plate (Fujifilm BAS-TR 2025) for 24 hours and the plate was scanned using GE Typhoon FLA 7000 system. The radiography image in Figure 5 shows uneven distribution with hot spots along the edge and in the center of the samples. These hot spots may be the result of highly localized concentration of ligands or surface defects that were observed in SEM. This unevenness in distribution may cause inaccurate activity measurement by alpha spectroscopy due to a bias in the energy calibration. PLEs based on HDEHP have been evaluated. The concentration of ligand in polystyrene is critical in the performance of the PLE; both for extraction efficiency as well as for alpha spectrometry results. The optimal PLE using this ligand has a concentration of 1:5 ligand to polystyrene. Under laboratory conditions, this configuration can produce similar results to those obtained for DIPEX based PLEs from previous studies. The concentration is very important to the results obtained for this ligand. This PLE is a good candidate for use in later field studies. Our next report will detail the evaluation of PLEs utilizing crown ether ligands.

36 MATERIALS SCIENCE↗

Mobile platform for radiological characterization of sites under or after decommissioning - 15139

Nowadays, nuclear industry is facing a crucial need in establishing radiological characterization for the assessment and the monitoring of any remediation work. Regarding its experience in this domain, the French Commission for Atomic Energy and Alternative Energies (CEA) of Fontenay-aux-Roses, established an important feedback and developed a sound methodology for radiological characterization. A clean-up project is managed from the initial surface characterization to the final one, once volumes of contaminated soil have been removed. Samples are collected via recognized methods and data is gathered by real-time acquisition with different conveyance such as all-in-vehicles, cart, walking, helicopter or drone. Accurate radiological analyses are performed on site thanks to the mobile laboratories cluster, called SMaRT. It enables to realize long-time gamma spectroscopy, chemical preparation for alpha spectroscopy or beta liquid scintillation counting. Data is processed with geo-statistics via the software Kartotrak, 2D or 3D mapping are created with the associated uncertainty and probability map. Drilling profiles with geological data (layers composition, particles size, etc.) are studied in order to understand the behavior of the contamination in depth. Source term, contaminated volumes and sanitary impact are calculated in order to determine the optimum excavation depth. Finally, data is stored in an online site that insures the traceability of the whole process. This just-in-time production model allows a fast response and control of costs and avoids the disadvantages of radioactive material transport. This whole innovative process, developed inside the mobile platform, requires all these tools that have been used in France and continuously evolving for more than 10 years thanks to a learning organization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗