Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANGLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Surface morphology and electrical properties of Au/Ni/ Left-Pointing-Angle-Bracket C Right-Pointing-Angle-Bracket /n-Ga{sub 2}O{sub 3}/p-GaSe Left-Pointing-Angle-Bracket KNO{sub 3} Right-Pointing-Angle-Bracket hybrid structures fabricated on the basis of a layered semiconductor with nanoscale ferroelectric inclusions

Features of the formation of Au/Ni/ Left-Pointing-Angle-Bracket C Right-Pointing-Angle-Bracket /n-Ga{sub 2}O{sub 3} hybrid nanostructures on a Van der Waals surface (0001) of 'layered semiconductor-ferroelectric' composite nanostructures (p-GaSe Left-Pointing-Angle-Bracket KNO{sub 3} Right-Pointing-Angle-Bracket ) are studied using atomic-force microscopy. The room-temperature current-voltage characteristics and the dependence of the impedance spectrum of hybrid structures on a bias voltage are studied. The current-voltage characteristic includes a resonance peak and a portion with negative differential resistance. The current attains a maximum at a certain bias voltage, when electric polarization switching in nanoscale three-dimensional inclusions in the layered GaSe matrix occurs. In the high-frequency region (f > 10{sup 6} Hz), inductive-type impedance (a large negative capacitance of structures, {approx}10{sup 6} F/mm{sup 2}) is detected. This effect is due to spinpolarized electron transport in a series of interconnected semiconductor composite nanostructures with multiple p-GaSe Left-Pointing-Angle-Bracket KNO{sub 3} Right-Pointing-Angle-Bracket quantum wells and a forward-biased 'ferromagnetic metal-semiconductor' polarizer (Au/Ni/ Left-Pointing-Angle-Bracket C Right-Pointing-Angle-Bracket /n{sup +}-Ga{sub 2}O{sub 3}/n-Ga{sub 2}O{sub 3}). A shift of the maximum (current hysteresis) is detected in the current-voltage characteristics for various directions of the variations in bias voltage.

36 MATERIALS SCIENCE↗

Small-Angle and Ultrasmall-Angle Neutron Scattering (SANS/USANS) Study of New Albany Shale: A Treatise on Microporosity

We applied small-angle neutron scattering (SANS) and ultrasmall-angle neutron scattering (USANS) techniques in order to study the microstructure of several New Albany shales of different maturity. It has been established that the total porosity decreases with maturity and increases somewhat for post-mature samples. One new method of SANS data analysis was developed, which allows the extraction of information about the size range and number density of micropores from the relatively flat scattering intensity observed in the limit of the large scattering vector Q. Macropores and significant number of mesopores are surface fractals, and their structure can be described in terms of the polydisperse spheres (PDSP) model. The model-independent Porod invariant method was employed to estimate total porosity, and the results were compared with the PDSP model results. It has been demonstrated that independent evaluation of incoherent background is crucial for accurate interpretation of the scattering data in the limit of large Q-values. Moreover, pore volumes estimated by the N-2 and CO 2 adsorption, as well as via the mercury intrusion technique, have been compared with those measured by SANS/USANS, and possible reasons for the observed discrepancies are discussed.

04 OIL SHALES AND TAR SANDS↗

A high-speed one-dimensional detector for time-resolved small -angle X-ray scattering : design and characterization.

A high-speed one-dimensional detector for time-resolved small-angle x-ray scattering has been designed and built for experiments at the Advanced Photon Source of Argonne National Laboratory. This detector is made from a 500-?m thick by 150-mm diameter ultra-high-purity n-type silicon wafer. The electrodes, which are a series of concentric rings that are deposited in the wafer, integrate the scattered x-rays over the azimuthal angle and, thereby, produce a one-dimensional detector. This design yields 128 rings, which allows parallel processing of the signal from each ring. The readout electronics consist of transimpedance front-end amplifiers, one for each ring, followed by active pulse-shaping filters. The amplifier signals are digitized using 12-bit analog-to-digital converters, one per ring, which operate at 20 MHz. The frame rate of the system is 271 kHz. Up to 220 - 1 scattering profiles may be stored on a random access memory chip and transferred to a data file at a rate of 16 x 103 profiles/sec. For X-ray energies between 3.5 and 13.2 keV the efficiency exceeds 80%. The resolving time of the electronics is 300 ns, which is sufficient to isolate electronically a single pulse of scattered x-rays when the synchrotron is operated in a hybrid or asymmetric fill pattern. Therefore, laser-pump/x-ray-probe experiments can be performed without a mechanical shutter. Examples of time-resolved speckle and the kinetics of the formation of sodium chloride particles are presented. This detector is capable of acquiring small-angle x-ray scattering profiles over multiple time scales, which are needed to characterize many chemical, physical, and biological processes. In addition, this detector may be tested and calibrated before experimental runs, without access to an intense beam of x-rays, with alpha particles from a radioactive source such as 241Am.

43 PARTICLE ACCELERATORS↗

Measurement of carbon condensates using small-angle x-ray scattering during detonation of the high explosive hexanitrostilbene

The dynamics of carbon condensation in detonating high explosives remains controversial. Detonation model validation requires data for processes occurring at nanometer length scales on time scales ranging from nanoseconds to microseconds. A new detonation endstation has been commissioned to acquire and provide time-resolved small-angle x-ray scattering (SAXS) from detonating explosives. Hexanitrostilbene (HNS) was selected as the first to investigate due to its ease of initiation using exploding foils and flyers, vacuum compatibility, high thermal stability, and stoichiometric carbon abundance that produces high carbon condensate yields. The SAXS data during detonation, collected with 300 ns time resolution, provide unprecedented signal fidelity over a broad q-range. This fidelity permits the first analysis of both the Guinier and Porod/power-law regions of the scattering profile during detonation, which contains information about the size and morphology of the resultant carbon condensate nanoparticles. To bolster confidence in these data, the scattering angle and intensity were additionally cross-referenced with a separate, highly calibrated SAXS beamline. The data show that HNS produces carbon particles with a radius of gyration of 2.7 nm in less than 400 ns after the detonation front has passed, and this size and morphology are constant over the next several microseconds. These data directly contradict previous pioneering work on RDX/TNT mixtures and TATB, where observations indicate significant particle growth (50% or more) continues over several microseconds. The power-law slope is about −3, which is consistent with a complex disordered, irregular, or folded sp{sup 2} sub-arrangement within a relatively monodisperse structure possessing radius of gyration of 2.7 nm after the detonation of HNS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the Effective Weak Mixing Angle in p p ¯ → Z / γ * → e + e - Events

We present a measurement of the fundamental parameter of the standard model, the weak mixing angle sin 2 θ ℓ eff which determines the relative strength of weak and electromagnetic interactions, in pp¯→Z/γ*→e + e - events at a center of mass energy of 1.96 TeV, using data corresponding to 9.7 fb -1 of integrated luminosity collected by the D0 detector at the Fermilab Tevatron. The effective weak mixing angle is extracted from the forward-backward charge asymmetry as a function of the invariant mass around the Z boson pole. The measured value of sin 2 θ ℓ eff =0.23147±0.00047 is the most precise measurement from light quark interactions to date, with a precision close to the best LEP and SLD results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic Structure of the Topological Insulator Bi2Se3 Using Angle-Resolved Photoemission Spectroscopy: Evidence for a Nearly Full Surface Spin Polarization

We performed high-resolution spin- and angle-resolved photoemission spectroscopy studies of the electronic structure and the spin texture on the surface of Bi{sub 2}Se{sub 3}, a model TI. By tuning the photon energy, we found that the topological surface state is well separated from the bulk states in the vicinity of k{sub z} = Z plane of the bulk Brillouin zone. The spin-resolved measurements in that region indicate a very high degree of spin polarization of the surface state, {approx}0.75, much higher than previously reported. Our results demonstrate that the topological surface state on Bi{sub 2}Se{sub 3} is highly spin polarized and that the dominant factors limiting the polarization are mainly extrinsic.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Realizing in-plane surface diffraction by x-ray multiple-beam diffraction with large incidence angle

Based on rigorous dynamical-theory calculations, we demonstrate in this paper the principle of an x-ray multiple-beam diffraction (MBD) scheme that overcomes the long-lasting difficulties of high-resolution in-plane diffraction from crystal surfaces. This scheme only utilizes symmetric reflection geometry with large incident angles but activates the out-of-plane and in-plane diffraction processes simultaneously and separately in the continuous MBD planes. The in-plane diffraction is realized by detoured MBD, where the intermediate diffracted waves propagate parallel to the surface, which corresponds to an absolute Bragg surface diffraction configuration that is extremely sensitive to surface structures. Finally, a series of MBD diffraction and imaging techniques may be developed from this principle to study surface/interface (misfit) strains, lateral nanostructures, and phase transitions of a wide range of (pseudo)cubic crystal structures, including ultrathin epitaxial films and multilayers, quantum dots, strain-engineered semiconductor or (multi)ferroic materials, etc.

36 MATERIALS SCIENCE↗

Characterization of the Decaheme c-Type Cytochrome OmcA in Solution and on Hematite Surfaces by Small Angle X-Ray Scattering and Neutron Reflectometry

The outer membrane protein OmcA is an 85 kDa decaheme c-type cytochrome located on the surface of the dissimilatory metal-reducing bacterium Shewanella oneidensis MR-1. It is assumed to mediate shuttling of electrons to extracellular acceptors that include solid metal oxides such as hematite (α-Fe 2 O 3 ). No information is yet available concerning OmcA structure in physiologically relevant conditions such as aqueous environments. We purified OmcA and characterized its solution structure by small angle x-ray scattering (SAXS), and its interaction at the hematite-water interface by neutron reflectometry. SAXS showed that OmcA is a monomer that adopts a flat ellipsoidal shape with an overall dimension of 34 × 90 × 65 Å 3 . To our knowledge, we obtained the first direct evidence that OmcA undergoes a redox state-dependent conformational change in solution whereby reduction decreases the overall length of OmcA by ~7 Å (the maximum dimension was 96 Å for oxidized OmcA, and 89 Å for NADH and dithionite-reduced OmcA). OmcA was also found to physically interact with electron shuttle molecules such as flavin mononucleotide, resulting in the formation of high-molecular-weight assemblies. Neutron reflectometry showed that OmcA forms a well-defined monomolecular layer on hematite surfaces, where it assumes an orientation that maximizes its contact area with the mineral surface. Finally, these novel insights into the molecular structure of OmcA in solution, and its interaction with insoluble hematite and small organic ligands, demonstrate the fundamental structural bases underlying OmcA's role in mediating redox processes.

Environmental Molecular Sciences Laboratory↗

Exploring Pore Formation of Atomic Layer-Deposited Overlayers by in Situ Small- and Wide-Angle X-ray Scattering

In this work, we explore the pore structure of overcoated materials by in situ synchrotron small- and wide-angle X-ray scattering (SAXS)/(WAXS). Thin films of aluminum oxide (Al2O3) and titanium dioxide (TiO2) with thicknesses of 4.9 and 2.5 nm, respectively, are prepared by atomic layer deposition (ALD) on non-porous nanoparticles. In situ X-ray measurements reveal that porosity is induced in the ALD films by annealing the samples at high temperature. Moreover, this pore formation can be attributed to densification resulting from an amorphous to crystalline phase transition of the ALD films as confirmed by high resolution X-ray diffraction (XRD) and pair distribution function (PDF). Simultaneous SAXS/WAXS results not only show that the porosity is formed by this phase transition but also that the pore size increases with temperature.

Li, Tao↗

Effect of Blown Powder Directed Energy Deposition Angle On Overspray Contamination

Abstract Blown powder directed energy deposition (DED) hybrid machine tools are particularly beneficial when the net shape of a component is to be manufactured in an additive and machined interleaved fashion. This investigation seeks to analyze the effect of the additive head lean angle relative to the part on blown powder DED surface contamination due to overspray. These hybrid DED platforms are commonly installed on multi-axis machining systems where the lean of the deposition head relative to the component surface can be controlled by tilting the component. The blown powder DED process has a 10–50% lower catchment efficiency as compared to wire fed DED systems. This excess powder is still fed towards the deposition location where the particles are heated by the laser and rebound off the melt pool. Some of these heated particles impact the previously machined thin-wall surface. While the deposition process and tool path planning process has been evaluated, the effect of the overspray due to lean angle of the deposition head on the previously thin-wall machined surface is not yet fully understood. This investigation found that minimum lean angle coincides with minimal overspray effect with nearly no contamination. If a lean angle is required, the maximum lean angle possible should be implemented for the smallest effected overspray area on the machined surface which was found to decrease the affect zone by half compared to intermediate lean angles. A diameter divergence was also noticed as the deposition angle was increased. In this study, a thorough analysis of the surface and geometric effects when depositing thin-walled components at varying angles is completed. It has been shown that part quality can be significantly affected by lean angle and thus must be incorporated as an additional design consideration in the manufacturing process.

Heinrich, Lauren↗

SU-E-T-446: Group-Sparsity Based Angle Generation Method for Beam Angle Optimization

Purpose: This work is to develop the effective algorithm for beam angle optimization (BAO), with the emphasis on enabling further improvement from existing treatment-dependent templates based on clinical knowledge and experience. Methods: The proposed BAO algorithm utilizes a priori beam angle templates as the initial guess, and iteratively generates angular updates for this initial set, namely angle generation method, with improved dose conformality that is quantitatively measured by the objective function. That is, during each iteration, we select “the test angle” in the initial set, and use group-sparsity based fluence map optimization to identify “the candidate angle” for updating “the test angle”, for which all the angles in the initial set except “the test angle”, namely “the fixed set”, are set free, i.e., with no group-sparsity penalty, and the rest of angles including “the test angle” during this iteration are in “the working set”. And then “the candidate angle” is selected with the smallest objective function value from the angles in “the working set” with locally maximal group sparsity, and replaces “the test angle” if “the fixed set” with “the candidate angle” has a smaller objective function value by solving the standard fluence map optimization (with no group-sparsity regularization). Similarly other angles in the initial set are in turn selected as “the test angle” for angular updates and this chain of updates is iterated until no further new angular update is identified for a full loop. Results: The tests using the MGH public prostate dataset demonstrated the effectiveness of the proposed BAO algorithm. For example, the optimized angular set from the proposed BAO algorithm was better the MGH template. Conclusion: A new BAO algorithm is proposed based on the angle generation method via group sparsity, with improved dose conformality from the given template. Hao Gao was partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗