Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANNULAR SPACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Apparatus to measure permeation of a gas through a membrane

The present invention relates to an apparatus to measure permeation of a gas through a membrane. The membrane is mounted on a flange with two sealing areas. The region between the sealing areas defines an annular space. The annular space is swept with a gas in order to carry away any of the permeating gas which may leak through the sealing areas.

42 ENGINEERING↗

Annular Pressure Buildup Calculation When Annulus Contains Gas

During the execution of technological operations such as multiple pressure relief or foam separation during well injection, a gas column can form at the wellhead in the annular space, leading to annular pressure buildup (APB). Based on the theory of heat transfer, a model was proposed for calculating the wellbore heat transfer during production. Taking into account the expansion and compression of the fluid, changes in the wellhead volume, the thermodynamic characteristics of the liquid, and the equation of state of the gas, APB calculations were performed. Based on these parameters, the influence of the gas column height on APB was evaluated. The results of the studies show that the coefficients of expansion and compressibility in the annulus depend on density, pressure and temperature: the higher the productivity of the gas well, the higher the temperature and pressure in the annulus; the greater the height of the gas column, the lower the pressure at the wellhead. For a well with a productivity of 30· 10{sup 4} m{sup 3}/day and gas column height of 70 m in the annulus, the APB is reduced to atmospheric pressure. Studies of the model for calculating APB of the annular trapped gas provide a theoretical basis for developing optimal technological parameters for the operation of gas wells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat exchangers and related systems and methods

A heat exchanger may include a main body with an inlet plenum and an outlet plenum at a first end, and a header at a second end. At least one elongated shaft may extend from the outlet plenum to the header. At least one heat pipe may be coupled to the header and a portion of each heat pipe may be positioned within a corresponding elongated shaft defining an annular space between each heat pipe and each corresponding elongated shaft. A flow skirt may include a manifold located between the inlet plenum and the outlet plenum of the main body. At least one elongated tube may extend from the manifold. Each elongated tube may be positioned within a corresponding annular space between each heat pipe and each corresponding elongated shaft, dividing the annular space into two concentric annular channels comprising an inner annular channel and an outer annular channel.

Yoon, SuJong↗

Apparatus and method for maintaining multi-component sample gas constituents in vapor phase during sample extraction and cooling

A dilution apparatus for diluting a gas sample. The apparatus includes a sample gas conduit having a sample gas inlet end and a diluted sample gas outlet end, and a sample gas flow restricting orifice disposed proximate the sample gas inlet end connected with the sample gas conduit and providing fluid communication between the exterior and the interior of the sample gas conduit. A diluted sample gas conduit is provided within the sample gas conduit having a mixing end with a mixing space inlet opening disposed proximate the sample gas inlet end, thereby forming an annular space between the sample gas conduit and the diluted sample gas conduit. The mixing end of the diluted sample gas conduit is disposed at a distance from the sample gas flow restricting orifice. A dilution gas source connected with the sample gas inlet end of the sample gas conduit is provided for introducing a dilution gas into the annular space, and a filter is provided for filtering the sample gas. The apparatus is particularly suited for diluting heated sample gases containing one or more condensable components.

42 ENGINEERING↗

Cooling system for rotating machine

An electrical machine comprising a rotor is presented. The electrical machine includes the rotor disposed on a rotatable shaft and defining a plurality of radial protrusions extending from the shaft up to a periphery of the rotor. The radial protrusions having cavities define a fluid path. A stationary shaft is disposed concentrically within the rotatable shaft wherein an annular space is formed between the stationary and rotatable shaft. A plurality of magnetic segments is disposed on the radial protrusions and the fluid path from within the stationary shaft into the annular space and extending through the cavities within the radial protrusions.

42 ENGINEERING↗

Performance Analyses of Supercritical Carbon Dioxide-Based Parabolic Trough Collectors with Double-Glazed Receivers

Supercritical carbon dioxide is becoming a hot research topic as a potential heat transfer fluid in parabolic trough concentrators since it enables operating the solar system at high temperatures for a higher quality of energy. However, the corresponding inflated thermal losses necessitate alternative receiver designs. This work examines four double-glazed receivers, with each annular space being evacuated or non-evacuated, in terms of the absorber tube's diameter (53-80 mm) and the diameter ratios of the two glass shells (1.2-2.0). An analytical model is developed and validated for this purpose, and the four designs are further examined using ground-level solar and meteorological measurements. The results demonstrate higher performance in the case of fully evacuating the receiver and using the smallest possible diameters of the three concentric cylinders, where the energy and exergy efficiencies reach 65.3 and 40.3%, respectively. Yet, evacuating only the inner annular space is sufficient to achieve virtually the same performance level. This energy efficiency decreases to 62% in case of increasing the tube diameter to 80 mm. As the operating temperature increases from 423 to 850 K, the specific thermal losses increase by 3.98-4.34 folds, depending on the receiver design. Double glazing the receivers is favorable only at high operating temperatures of sCO2, where the reduction in thermal losses overcomes the drop in optical efficiency. For an inlet sCO2 temperature of 850 K, thermal losses are reduced by 33.64 and 53.92%, compared to evacuated and non-evacuated single-glazed receivers, respectively. Throughout the year, the fully evacuated and fully non-evacuated double-glazed receivers have energy efficiencies of 54.96 and 52.39%, exergy efficiencies of 33.64 and 32.06%, and thermal losses of 348.8 and 402.5 W/m, respectively.

analytical model↗

Experimental Study on Performance Enhancement of Evacuated Tube by Constant Heat Flux Mode

The evacuated tube collector with U shape copper absorber tube is considered for the analysis. The experimental investigation is conducted on parabolic trough collector with U shape tube as absorber tube. The effect of the sudden fluctuations in the solar radiation on the performance of the collector is reduced by means of evacuated tube collector filled with thermic fluids. The analysis is performed with different thermic fluids such as dowtherm, therminol66, glycol water and ethylene glycol, are filled in the annular space between inner glass tube and U shape copper absorber tube. The experimentation is carried out at various mass flow rates from 20 to 100 LPH with the step-up flow rate of 20 LPH. A comparative study is carried out on various parameters such as effect of mass flow rate over instantaneous efficiency, useful heat gain and work input, etc. The characteristic curve of cylindrical parabolic trough collector (PTC) is also discussed. Experimental results show that, ethylene glycol gives better efficiency over mass flow rate and therminol66 gives best power heat ratio. Heat transfer mediums and its properties [specific heat capacity, thermal conductivity and dynamic viscosity] for all specified heat transfer fluids are also discussed. The results obtained with various specified heat transfer fluids filled in the annulus space of evacuated tube are compared with plain evacuated tube. It is observed that there is significant enhancement of overall instantaneous collection efficiency of the parabolic trough collector.

14 SOLAR ENERGY↗

IMAGING HIGH SPEED PARTICLES IN EXPLOSIVE DRIVEN BLAST WAVES

This research describes a new application of a commercially available particle image velocimetry (PIV) instrument adapted for imaging particles in a blast wave. Powder was dispersed through the PIV light sheet using a right circular cylindrical charge containing aluminum powder filled in the annular space between the explosive core and exterior paper tube wall of the charge. Images acquired from each shot showed particle agglomeration and unique structures with the smaller particle diameters having developed structured appearances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3-60B Type-B shipping cask enhanced operational features to facilitate leakage rate testing - 15585

EnergySolutions is fabricating a new 3-60B Type B Shipping Cask that will be ready for use in spring 2015, designed for shipping Type B quantities of activated and/or non-fuel-bearing reactor or accelerator components. EnergySolutions, in consult with Leak Testing Specialists, Inc., has implemented an improved design of the 3-60B cask closures to better facilitate periodic and maintenance leakage rate testing and to allow end users to more easily perform pre-shipment leakage rate testing to confirm proper assembly of the cask closures. A typical Type B cask closure lid design incorporates a double O-ring configuration, where the inner O-ring provides containment and the outer O-ring is used for leakage rate testing of the containment O-ring seal. Leakage rate testing of a double O-ring configuration is typically accomplished by filling the cask cavity with helium, pulling a vacuum on the annular space between the two O-rings and monitoring for helium leakage through the containment O-ring. One issue is the potential for helium saturation of the O-ring elastomeric material, which can result in leakage rate test failures. The cask cavity volume is typically large, and takes a significant amount of time to fill with helium. As a result, the saturation time for certain elastomeric compounds may be exceeded, leading to potential false-negative leakage rate testing results. To avoid this, that the cask cavity typically is loaded with sealed container(s) to reduce the free volume and the fill time. The improved 3-60B cask closure lid incorporates a triple O-ring seal configuration that facilitates maintenance leak rate testing of the closure lid containment O-ring seal and eliminates the issues discussed above. The triple O-ring configuration uses the middle O-ring as the containment seal, with the inner and outer test O-rings creating relatively small annular volumes for testing purposes. These small annular volumes are quick to fill, minimizing the issue of Helium saturation of the O-ring material. This seal configuration also makes it possible to detect and replace a damaged O-ring seal during loading operations, or dress a damaged sealing surface, and perform the required maintenance leakage rate testing of the replacement O-ring at the plant site without the need to unload the cask and send it to a maintenance facility. Also, a second test port has been added to each O-ring annulus to allow leakage rate testing to be accomplished using a formal system calibration that complies with the requirements and recommendations of ASME Section V, Article 10 [4], ANSI N14.5-97 [2], and ANSI N14.5-2014 [3]. This provides a simple, reliable, and accurate means to perform leakage rate testing with a test confidence level that cannot be achieved without the second test port. The improved closure and test port design simplifies and shortens the time required to perform leakage testing, resulting in reduced operating costs, greater schedule security, and dose savings for the cask users. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests

Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.

58 GEOSCIENCES↗

Solid Phase Characterization of Tank 241-AY-102 Annulus Space Particulate

The Special Analytical Studies Group at the 222-S Laboratory (222-S) examined the particulate recovered from a series of samples from the annular space of tank 241-AY-102 (AY-102) using solid phase characterization (SPC) methods. These include scanning electron microscopy (SEM) using the ASPEX® scanning electron microscope, X-ray diffraction (XRD) using the Rigaku® MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon® Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A comprehensive review on the loss of wellbore integrity due to cement failure and available remedial methods

With the recent abrupt fluctuations in oil pricing and the need of complying with environmental and social requirements, nowadays it is an urgent call for the oil and gas industry to produce the hydrocarbon without any loss as well as in a safe manner. Cements are placed in the annular space of casing to provide zonal isolation in between wellbore and surface during the operational life cycle of the well or even after the abandonment. But this is not what happens most of the time. Cement degrades or loses its integrity through debonding either from the casing or formation and generates cracks or fractures due to varied reasons throughout the life of the well. Multiple causes contribute to the loss of wellbore integrity – either by physical, mechanical, or chemical processes. These failures lead to sustained casing pressure (SCP) and contamination of surrounding environment. To combat this issue or to restore the well integrity, multiple remedial actions have also been either implemented in the industry or proposed based on experimental research to prevent the damage or to seal the leakage in the cement sheath. Here, this paper will provide an extensive review of the underlying reasons of cement failure and the available remedial actions to minimize the loss of well integrity issue. These information are not only useful to know about the different corrective options available for us to implement in industry but also it will provide us a knowledge base regarding how we can enhance the performance of the exiting systems to battle the cement integrity problem more efficiently.

02 PETROLEUM↗

MRI of Whole Rat Brain Perivascular Network Reveals Role for Ventricles in Brain Waste Clearance

Investigating the mechanisms by which metabolic wastes are cleared from nervous tissue is important for understanding natural function and the pathophysiology of several neurological disorders including Alzheimer’s disease. Recent evidence suggests clearance may be the function of annular spaces around cerebral blood vessels, called perivascular spaces (PVS), through which cerebrospinal fluid (CSF) is transported from the subarachnoid space into brain parenchyma to exchange with interstitial fluid (also known as the glymphatic system). In this work, an MRI-based methodology was developed to reconstruct the PVS network in whole rat brain to better elucidate both PVS uptake and clearance pathways. MR visible tracer (Gd-albumin) was infused in vivo into the CSF-filled lateral ventricle followed by ex vivo high-resolution MR imaging at 17.6 T with an image voxel volume two orders of magnitude smaller than previously reported. Imaged tracer distribution patterns were reconstructed to obtain a more complete brain PVS network. Several PVS connections were repeatedly highlighted across different animals, and new PVS connections between ventricles and different parts of the brain parenchyma were revealed suggesting a possible role for the ventricles as a source or sink for solutes in the brain. In the future, this methodology may be applied to understand changes in the PVS network with disease.

60 APPLIED LIFE SCIENCES↗

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60°C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

Materials Assessment of Insulating Foam in the 9977 Shipping Package for Long-Term Storage - Annual Report

The 9977 shipping package is being evaluated for long-term storage applications in the K-Area Complex (KAC) with specific focus on the packaging foam material. A rigid closed cell polyurethane foam, LAST-A-FOAM® FR-3716, produced by General Plastics Manufacturing Company is sprayed and expands to fill the void between the inner container and the outer shell of the package. The foam is sealed in this annular space and is not accessible. During shipping and storage, the foam experiences higher than ambient temperatures from the heat generated by nuclear material within the package creating the potential for degradation of the foam. A series of experiments is underway to determine the extent of foam degradation. Foam samples of three densities have been aging at elevated temperatures 160 °F, 160 °F + 50% relative humidity (RH), 185 °F, 215 °F, and 250 °F since 2014. Samples were periodically removed and tested. After approximately 80 weeks, samples conditioned at 160 °F, 160 °F + 50% RH, and 185 °F have retained initial property values while samples conditioned at 215 °F have reduced intumescence. Samples conditioned at 250 °F have shown the most degradation, loss of volume, mass, absorbed energy under compression, intumescence, and increased flammability. Based on the initial data, temperatures up to 185 °F have not yet shown an adverse effect on the foam properties and it is recommended that exposure of FR-3716 foam to temperatures in excess of 250 °F be avoided or minimized. Testing will continue beyond the 96 week mark. This will provide additional data to help define the long-term behavior for the lower temperature conditions. Additional testing will be pursued in an attempt to identify transition points (threshold times and temperatures) at the higher temperatures of interest, as well as possible benefits of aging within the relatively oxygen-free environment the foam experiences inside the 9977 shipping package.

36 MATERIALS SCIENCE↗

Annual Radioactive Waste Tank Inspection Program - 2018

The Department of Energy (DOE) requires that Savannah River Remediation LLC (SRR), the Liquid Waste contractor, maintain a robust and timely Structural Integrity Program for waste tanks that are leak-tight and for waste tanks that have leaked or are suspect. These requirements are promulgated in DOE Manual 435.1-1, Section II.Q.(2). A key aspect of SRR's implementation of these requirements is its annual tank inspection program. In 2018, the SRR Visual and In-Service Inspection Program used two visual imagery techniques to ascertain the integrity of the Savannah River Site (SRS) waste tanks: high resolution digital photography and closed-circuit television. The primary inspection method made use of direct photograph techniques, e.g., making a series of photographs providing detailed views of the tank and wide-angle photography for obtaining overviews of large areas. Closed-circuit television was then typically used to further investigate conditions found during the initial inspection. During 2018, a total of 4,853 photographs were taken and 47 video inspections were performed as part of this inspection program. Of the 51 waste tank systems at SRS that were designed, constructed, and placed into active service storing radioactive liquid waste, 43 remain in active service. Eight tanks have been cleaned, stabilized by filling with engineered grout, and removed from service (also known as operationally closed) -Tanks 5, 6, and 12 (Type I tanks); Tank 16 (Type II tank); and Tanks 17, 18, 19, and 20 (Type IV tanks). For the 43 waste tanks, inspections were successfully conducted in 2018 through all accessible annulus risers and inspection ports for nine Type I tanks, three Type II tanks, and 27 Type III/IIIA tanks; at least one inspection was made in the interior of four Type IV tanks (i.e., the tanks without annular spaces) above the liquid level in the tank. Rainwater continues periodically to be observed migrating into the annuli of some tanks. Evidence of this infiltration was primarily noted by observation of surface stains, and occasionally by calciferous deposits, changed configuration of salt deposits in the associated annulus, and mild surface corrosion. The conditions of the 43 tanks remained essentially unchanged from the conditions reported in 2017. The one key exception was the identification of eight new cracks in the Tank 15 primary tank wall. These newly identified cracks are located at 65, 67, 70, 76, 150, 152, 176 inches and 200 inches above the tank bottom. The identified cracks in Tank 15 do not constitute an impact on the structural integrity of the tank, as evaluated and confirmed in the referenced report, SRNS-STI-2008-00028, A Structural Impact Assessment of Flaws Detected During Ultrasonic Examination of Tank 15, and calculation, T-CLC-H-00890, Calculation of Critical Crack Lengths in HLW Tank 15. The 2018 inspection program confirmed the structural integrity and waste confinement capability of all 43 waste tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3013 Inner Can Lid Leak Test System Development

Contained in this report is a description of the 3013 inner container lid leak detection system, a listing of the data collected to validate the system and a statistical analysis of collected data. The 3013 Container Surveillance Program provides assessment criteria and evaluates 3013 containers selected from the storage inventory for potential degradation mechanisms. The 3013 outer container is the boundary credited to prevent release of material to the environment. The integrity of the outer container is only at risk if the inner container loses its seal and allows corrosive gases to diffuse into the outer container. To date, the determination of potential outer container exposure to corrosive gases has been through comparison of the gas analysis of the annular space and the inner container. If the two volumes have the same gas composition and pressure, then the inner container may have leaked. The leak detection system described in this report will provide a direct measurement of the integrity of the inner container, and if approved, will provide for the elimination of gas analysis. The inner container lid leak testing system consists of two basic parts: the Agilent leak testing instrument and the leak test fixture. The test fixture base provides the connection between the leak test instrument and the test sample. This connection allows helium to flow into the leak detector when a leak path exists in the test sample allowing leak measurement to be performed. The tests reported here were conducted in a cold lab using a configuration very similar, but not identical to, the configuration anticipated when installed in a glove box. A total of sixty-five leak rate measurements were made on 10 containers and the data is included in the report. The data analysis shows that the leak detection system can identify leaks in the lid, including the weld and heat affected zone of 3013 inner containers, during destructive examination. The measurements taken support that a 3013 IC lid with a leak rate value greater than 2.0 x 10 -7 atm cc/sec will be identified using the leak test system prior to introduction into a glove box. These results from the baseline for future tests of the leak test system after it is installed in the glove box for use as part of surveillance DE.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗