Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANODE PLANE ARRAYS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

ProtoDUNE Anode Plane Assembly

ProtoDUNE is a test bed for the Deep Underground Neutrino Experiment, an international physics project hosted at the Department of Energy's Fermilab. One of the ProtoDUNE detectors, which are being constructed at CERN, is a single-phase neutrino detector that uses liquid argon. It will require a number of anode plane arrays, special panels made of wire, to detect the signature of a neutrino interaction in the argon bath. This is a glimpse into the process of fabricating these planes, some of which are being created at the University of Wisconsin-Madison. Learn more about the ProtoDUNE detectors here: https://www.symmetrymagazine.org/article/the-biggest-little-detectors

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration and performance of an online data selection algorithm for liquid argon time projection chambers using MicroBooNE

The MicroBooNE detector is a liquid argon time projection chamber (LArTPC) that produces three-dimensional images of particle interactions using ionization charge collected by anode wire plane arrays and scintillation light collected by a light detection system. In addition to testing long-standing experimental neutrino anomalies and performing measurements of neutrino interactions with argon nuclei using the Fermilab Booster Neutrino Beam, MicroBooNE aims to develop methodologies for rare beyond the Standard Model and off-beam physics searches. Looking ahead to the upcoming Deep Underground Neutrino Experiment (DUNE), with MicroBooNE serving as a valuable testbed, achieving high sensitivity and livetime for off-beam physics while satisfying data processing and storage constraints will require data-driven, intelligent, and online or real-time data selection techniques. These techniques are essential for reducing data rates and preserving rare signals with high accuracy. In this paper, we describe a fast data selection algorithm suitable for online execution to identify electrons from stopping cosmic ray muons in the MicroBooNE detector utilizing ionization charge information, and present its performance. This represents the first demonstration of online data selection in a LArTPC using real data and charge information exclusively and provides an important proof-of-principle for applying such techniques to other LArTPC experiments such as the Short-Baseline Near Detector and DUNE.

Abratenko, P. [Tufts U. (main)]↗

Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The GCT camera for the Cherenkov Telescope Array

The Gamma Cherenkov Telescope (GCT) is one of the designs presented for the Small Sized Telescope (SST) section of the Cherenkov Telescope Array (CTA). The GCT uses dual-mirror optics, resulting in a compact telescope with good image quality and a large field of view with a smaller, more economical, camera than is achievable with conventional single mirror solutions. The photon counting GCT camera is designed to record the flashes of atmospheric Cherenkov light from gamma and cosmic ray initiated cascades, which last only a few tens of nanoseconds. The GCT optics require that the camera detectors follow a convex surface with a radius of curvature of 1 m and a diameter of ~35 cm, which is approximated by tiling the focal plane with 32 modules. The initial camera prototype is equipped with multi-anode photomultipliers, each comprising an 8×8 array of 6×6 mm 2 pixels to provide the required angular scale, adding up to 2048 pixels in total. Detector signals are shaped, amplified and digitised by electronics based on custom ASICs that provide digitisation at 1 GSample/s. The camera is self-triggering, retaining images where the focal plane light distribution matches predefined spatial and temporal criteria. The electronics are housed in the liquid-cooled, sealed camera enclosure. LED flashers at the corners of the focal plane provide a calibration source via reflection from the secondary mirror. The first GCT camera prototype underwent preliminary laboratory tests last year. In November 2015, the camera was installed on a prototype GCT telescope (SST-GATE) in Paris and was further used to successfully record the first Cherenkov light of any CTA prototype, and the first Cherenkov light seen with such a dual-mirror optical system. A second full-camera prototype based on Silicon Photomultipliers is under construction. Up to 35 GCTs are envisaged for CTA.

47 OTHER INSTRUMENTATION↗

Roughness of Ti Substrates for Control of the Preferred Orientation of TiO 2 Nanotube Arrays as a New Orientation Factor

We report the surface roughness of a Ti substrate as a critical factor for controlling the degree of the preferred orientation of anatase TiO2 nanotube arrays (NTAs) which are synthesized by anodization and a subsequent annealing process. The degree of the preferred orientation to the (004) plane of the anatase crystal structure has a strong dependency on the root-mean-square roughness (Sq) of the initial Ti substrate when the roughness-controlled substrates are anodized in an ethylene glycol-based electrolyte containing ~2 wt % of water. Highly preferred oriented NTAs were obtained from low-Sq (<10 nm) substrates, which were accompanied by uniform pore distribution and low concentration of hydroxyl ions in as-anodized amorphous NTAs. The mechanism of the preferred oriented crystallization of nanometer-scaled tube walls is explained considering the microscopic geometrical uniformity of the oxide barrier and nanopores at the early stage of anodization, which affected the local electric field and thus the insertion of the hydroxyl group into the amorphous TiO2 tube walls.

14 SOLAR ENERGY↗

Field emission behavior of vertically aligned ZnO nanowire planar cathodes

A field emission (FE) study by scanning anode field emission microscopy was performed to evaluate the FE properties of vertically aligned zinc oxide (ZnO) nanowire arrays electrodeposited on a plane conductive surface. The specific FE behaviors of the cathode observed experimentally are (1) a turn-on macroscopic field of about 6 V/{mu}m for a FE current density J{sub FE} 5 x 10{sup -4} A/cm{sup 2}, (2) a stable FE characteristics for 5 x 10{sup -4} < J{sub FE} < 5 x 10{sup -2} A/cm{sup 2}, and (3) a brutal shut down of FE when J{sub FE} crossed a limiting value of {approx}0.05 A/cm{sup 2} due to a rapid evolution of the nanowires toward a bulbous tip geometry or a complete melting. A physical process of FE from ZnO nanostructures is proposed from the experimental data analyses. An effective surface barrier of about 1 eV was determined from the experimental Fowler-Nordheim plot and the presence of a Zn enriched surface was assumed in considering the possibility of important modifications of the crystallography and charge transfers at the surface of ZnO nanowires during the application of the strong electric field required for FE.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

We have designed and tested a robust 20×20 cm 2 thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al 2 O 3 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm 2 array of 2-dimensional square ‘pads’ with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Larger sized wire arrays on 1.5 MA Z-pinch generator

Experiments on the UNR Zebra generator with Load Current Multiplier (LCM) allow for implosions of larger sized wire array loads than at standard current of 1 MA. Advantages of larger sized planar wire array implosions include enhanced energy coupling to plasmas, better diagnostic access to observable plasma regions, and more complex geometries of the wire loads. The experiments with larger sized wire arrays were performed on 1.5 MA Zebra with LCM (the anode-cathode gap was 1 cm, which is half the gap used in the standard mode). In particular, larger sized multi-planar wire arrays had two outer wire planes from mid-atomic-number wires to create a global magnetic field (gmf) and plasma flow between them. A modified central plane with a few Al wires at the edges was put in the middle between outer planes to influence gmf and to create Al plasma flow in the perpendicular direction (to the outer arrays plasma flow). Such modified plane has different number of empty slots: it was increased from 6 up to 10, hence increasing the gap inside the middle plane from 4.9 to 7.7 mm, respectively. Such load configuration allows for more independent study of the flows of L-shell mid-atomic-number plasma (between the outer planes) and K-shell Al plasma (which first fills the gap between the edge wires along the middle plane) and their radiation in space and time. We demonstrate that such configuration produces higher linear radiation yield and electron temperatures as well as advantages of better diagnostics access to observable plasma regions and how the load geometry (size of the gap in the middle plane) influences K-shell Al radiation. In particular, K-shell Al radiation was delayed compared to L-shell mid-atomic-number radiation when the gap in the middle plane was large enough (when the number of empty slots was increased up to ten)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray response of pixellated CdZnTe detectors

In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm{sup 3} single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mum BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T=10 deg.C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

36 MATERIALS SCIENCE↗

FELIX-Based Readout of the Single-Phase ProtoDUNE Detector

Large liquid argon (LAr) time projection chambers (TPCs) have been adopted for the Deep Underground Neutrino Experiment (DUNE) experiment's far detector, which will be composed of four 17-kton detectors situated 1.5 km underground at the Sanford Underground Research Facility. This represents a large increase in scale compared to existing experiments. Both single- and dual-phase technologies will be validated at CERN, in cryostats capable of accommodating full-size detector modules, and exposed to low-energy charged particle beams. This program, called ProtoDUNE, also allows for extensive tests of data acquisition strategies. The Front-End LInk eXchange (FELIX) readout system was initially developed within the ATLAS collaboration and is based on custom field-programmable gate array (FPGA)-based Peripheral Component Interconnect Express input/output cards, connected through point-to-point links to the detector front end and hosted in commodity servers. FELIX will be used in the single-phase ProtoDUNE setup to read the data coming from 2560 anode wires organized in a single anode plane assembly (APS) structure. With a continuous readout at a sampling rate of 2 MHz, the system must deal with an input rate of 96 Gb/s. An external trigger will preselect time windows of 5 ms with interesting activity expected inside the detector. Event building will occur for triggered events, at a target rate of 25 Hz; the readout system will form fragments from the data samples matching the time window, carry out lossless compression, and forward the data to event building nodes over 10-Gb/s Ethernet. This paper discusses the design and implementation of this readout system as well as the first operational experience.

47 OTHER INSTRUMENTATION↗

Preparing magnetic yttrium iron garnet nanodot arrays by ultrathin anodic alumina template on silicon substrate

Ultrahigh density periodically ordered magnetic yttrium iron garnet (Y{sub 3}Fe{sub 5}O{sub 12}, YIG) nanodot arrays have been prepared by pulsed laser deposition through an ultrathin alumina mask (UTAM). UTAM having periodically ordered circularly shaped holes with 350 nm in diameter, 450 nm in inter-pore distance, and 700 nm in height has been prepared on silicon substrate. Furthermore, the microstructure and magnetic properties of YIG nanodot arrays have been characterized. Nanodot arrays with a sharp distribution in diameter centered at 340 nm with standard deviation of 10 nm have been fabricated. Moreover, typical hysteresis loops and ferromagnetic resonance spectra in in-plane and out-of-plane revealed that this unique structure greatly influences the magnetics properties of YIG. First, coercivity of YIG nanodot arrays in in-plane was increased about from 15 Oe of YIG films to 500 Oe. Then, the degree of uniformity about nanodot height decided that two or more resonance peaks in out-of-plane were detected in the spectra. The peak-to-peak linewidth values were about 94 Oe and 40 Oe in the parallel and perpendicular directions, respectively, which indicated that the values were larger by the two-magnon scattering. Consequently, this pattering method creates opportunities for studying physics in oxide nanomagnets and may be applied in spin-wave devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mathematical modeling of novel porous transport layer architectures for proton exchange membrane electrolysis cells

Thin foil based porous transport layers (PTLs) that contain highly structured pore arrays have shown promise as anode PTLs in proton exchange membrane electrolysis cells. These novel PTLs, fabricated with advanced manufacturing techniques, produce thin, tunable, multifunctional layers with reduced flow and interfacial resistances and high thermal and electric conductivities. To further optimize their design, it is important to understand their fundamental impact on the transport of protons, electrons, and liquid/vapor mixtures in the electrode. In this work, we develop a two-dimensional multiphysics model to simulate the coupled electrochemistry and multiphase transport in an electrolysis cell operated with the novel PTL architecture. The results show that larger pores improve access of water to the anode catalyst layer, which is beneficial for both the oxygen evolution reaction and membrane hydration. Larger pore sizes also improve oxygen gas transport from the catalyst layer, because generated oxygen gas is forced to travel in-plane through the anode catalyst layer until it reaches a pore opening that is connected to a channel. The discussed results confirm that the proposed thin foil based PTLs are fundamentally different from conventional PTLs, such as felts or layered meshes. The model developed in this work also provides generalizable insight into fundamental PEMEC phenomena, such as the competition between liquid and gas phase transport, membrane hydration and water management, and nonuniform electrochemical reactions, which are processes relevant to all PEMEC designs.

25 ENERGY STORAGE↗

Wire array Z-pinch length variations for K-shell x-ray generation on Z.

Large diameter (50-70 mm) wire array z pinches are fielded on the refurbished Z machine to generate 1-10 keV K-shell x-ray radiation. Imploding with velocities approaching 100 cm/{micro}s, these loads create large dL/dt which generates a high voltage, stresses the convolute, and leads to current loss. High velocities are required to reach the few-keV electron temperatures required to strip moderate-atomic-number plasmas to the K shell, thus there is an inherent trade-off between achieving high velocity and stressing the pulsed power driver via the large dL/dt.Here, we present experiments in which the length of stagnated Cu and stainless steel z pinches was varied from 12-24 mm. The motivation in reducing the pinch height is to lower the final inductance and improve coupling to the generator. Shortening a Cu pinch from 20 to 12 mm by angling the anode glide plane reduced the final L and dL/dt, enhancing the feed current by 1.4 MA, nearly doubling the K-shell power per unit length, and increasing the net K-shell yield by 20%. X-ray spectroscopy is employed to assess differences in plasma conditions between the loads. Lengthening the pinch could lead to yield enhancements by increasing the mass participating in the implosion, provided the increased inductance is not overly detrimental to the current coupling. In addition to the experimental results, these scenarios are studied via thin-shell 0D and also magneto-hydrodynamic modeling with a coupled driver circuit model.

36 MATERIALS SCIENCE↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗