APS-U Definitions of Signs and Conventions Related to Magnets

The APS-U is planned to be a 4th generation hard X-ray light source utilizing a multi-bend achromat (MBA) magnet lattice. The MBA lattice will be installed in the existing APS storage ring enclosure. The stored electron beam will circulate clockwise when viewed from above. The X-ray beamlines will for the most part exit at the same source points as the present APS. This document defines the signs and conventions related to the APS-U MBA magnets. Included in this document are: the local magnet coordinate system, definitions of mechanical and magnetic centers, definitions of multipole field errors, magnetic roll angle, and magnet polarities.

43 PARTICLE ACCELERATORS↗

Mechanical Design Progress of the In Situ Nanoprobe Instrument for APS-U

The In Situ Nanoprobe (ISN, 19-ID) beamline will be a new best-in-class long beamline to be constructed as part of the Advanced Photon Source Upgrade (APS-U) project [1, 2]. To achieve long working distance at high spatial resolution, the ISN instrument will be positioned 210 m downstream of the x-ray source, in a dedicated satellite building, currently under construction [3]. The ISN instrument will use a nano-focusing Kirkpatrick-Baez (K-B) mirror system, which will focus hard x-rays to a focal spot as small as 20 nm, with a large working distance of 61 mm. The large working distance provides space for various in situ sample cells for x-ray fluorescence tomography and ptychographic 3D imaging, allows the use of a separate, independent vacuum chambers for the optics and sample, and provides the flexibility to run experiments in vacuum or at ambient pressure. A consequence of the small spot size and large working distance are stringent requirements for high angular stability of the K-B mirrors (5 nrad V-mirror and 16 nrad H-mirror) and high relative stability be-tween focus spot and sample (4 nmRMS). Additional features include fly-scanning up to 2 kg mass, sample plus in situ cell, at 1 mm/s in vertical and/or horizontal directions over an area of 10 mm x 10 mm. Environmental capabili-ties will include heating and cooling, flow of fluids and applied fields, as required for electrochemistry and flow of gases at high temperature for catalysis. To achieve these capabilities and precise requirements we have used precision engineering fundamentals to guide the design process.

Kearney, Steven P.↗

Fast and bright scintillators for ultrafast materials dynamics using 4th generation synchrotron

We present recent advances in fast and bright scintillators for ultrafast X-ray phase contrast imaging of dynamic materials experiments at the upgraded Advanced Photon Source (APS-U), a fourth generation synchrotron. APS-U enables hard X-ray imaging at frame rates of at least 13 MHz (corresponding to 77 ns or shorter interframe intervals), creating a new need for scintillators with faster response and higher light output than lutetium yttrium oxyorthosilicate (LYSO). For indirect imaging and diffraction with ultrafast cameras, commercial lanthanum bromide (LaBr3) and cerium bromide (CeBr3) are promising candidates. These materials exhibit decay times approximately a factor of two shorter than LYSO (around 40 ns) and lutetium oxyorthosilicate (LSO), while maintaining comparable light yield per incident X-ray photon. However, their implementation at APS-U requires addressing several challenges, including material limitations due to hygroscopicity, efficient optical coupling to imaging systems, and high quantum efficiency for conversion of scintillation light, predominantly at wavelengths below 400 nm, into detectable electronic signals. We report results from material characterization, detector integration and packaging, and beamline experiments of materials with impact. In addition, emerging scintillator classes, including perovskites and high-entropy materials, are discussed as potential alternatives for next-generation ultrafast X-ray diagnostics.

Wang, Zhehui [Los Alamos] (ORCID:0000000178264063)↗

Opportunities of Soft Materials Research at Advanced Photon Source

The storage ring of the Advanced Photon Source (APS) will be upgraded to a fourth-generation ring after more than two decades of operation. During its operation as a 7 GeV ring, scattering beamlines have been built to support soft matter research programs to take advantage of the high flux and high energy beam provided by the ring. Further, the 6 GeV multi-bend achromat storage ring installed by the APS-Upgrade (APS-U) will provide new opportunities for the scattering beamlines. In this news, activities of those APS beamlines in conjunction with the APS-U will be briefly reviewed along with some recent technical highlights of their soft matter research programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive comparison of two tracking codes for single-particle dynamics evaluation of a next-generation storage ring light source

Next-generation light sources based on the multibend achromat concept place great reliance on the accuracy of beam dynamics modeling. To ensure the success of such light sources, confirmation of design performance with at least two independent codes is prudent. The APS Upgrade (APS-U) lattice has been designed using the code ELEGANT, which has existing and new features that are needed by the design. Corresponding, independent improvements have recently been made to the accelerator toolbox (AT), in order to permit an independent check of nonlinear dynamics predictions. The new developments include the modeling of combined-function bending magnets with straight geometry and improved fringe field effects of quadrupole magnets. Calculations of linear and nonlinear lattice parameters and particle tracking results were compared, showing remarkable agreement was found between the two independently developed codes. This provides significant confirmation of the feasibility of the APS-U design.

storage ring↗

High-Charge Injector for on-Axis Injection Into A High-Performance Storage Ring Light Source

Next-generation, high-performance storage ring light sources based on multibend achromat optics will require on-axis injection because of the extremely small dynamic aperture. Injectors will need to supply full-current bunch replacement in the ring with high single-bunch charge for swap-out. For upgrades of existing light sources, such as the Advanced Photon Source Upgrade (APS-U), it is economical to retain the existing injector infrastructure and make appropriate improvements. The challenges to these improvements include achieving high single-bunch charge in the presence of instabilities, beam loading, charge stability and reliability. In this paper, we discuss the rationale for the injector upgrades chosen for APS-U, as well as backup and potential alternate schemes. To date, we have achieved single-bunch charge from the injectors that doubles the original design value, and have a goal to achieve about three times the original design value.

43 PARTICLE ACCELERATORS↗

FY23 Status Report of the Activated Materials Laboratory at the Advanced Photon Source

The Activated Materials Laboratory (AML) is a new radiological facility located at the Advanced Photon Source (APS) in Argonne National Laboratory (ANL), adjacent to the high-energy x-ray microscopy (HEXM) beamline in the long beamline building (LBB) constructed under the APS-upgrade (APS-U) project. The AML is a centralized facility to facilitate the safe conduct of experiments on activated materials at the APS. This report provides an overview of the status of the AML as a Nuclear Science User Facilities (NSUF) partner user facility in preparation for the general user access in 2024 upon the commissioning of the APS-U beamlines. Specifically, details are provided regarding the laboratory's scope, functionality, components, operational blueprint, and data management approach. The plans on augmenting the instrumentation, refining operational procedures and developing a robust data management strategy for FY24 and beyond are also discussed.

43 PARTICLE ACCELERATORS↗

FY24 accomplishments in preparation for startup of Activated Materials Laboratory (AML)

The Activated Materials Laboratory (AML) will be a new radiological facility at the Advanced Photon Source (APS) in Argonne National Laboratory (ANL), adjacent to the high-energy x-ray microscopy (HEXM) beamline in the long beamline building (LBB) constructed under the APS-upgrade (APS-U) project. The AML is a centralized facility to facilitate the safe conduct of experiments on activated materials at the APS. This report provides an overview of the status of the AML as a Nuclear Science User Facilities (NSUF) partner user facility in preparation for the general user access in 2025 upon the commissioning of the APS-U beamlines. The AML's scope, functionality and components are detailed. The NSUF partner beamlines’ commissioning status in the post-APS-U era is provided, along with the AML’s operational updates and operational plan.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of HPCAT and capabilities for studying minerals and various other materials at high-pressure conditions

Abstract High-Pressure Collaborative Access Team (HPCAT) is a synchrotron-based facility located at the Advanced Photon Source (APS). With four online experimental stations and various offline capabilities, HPCAT is focused on providing synchrotron x-ray capabilities for high pressure and temperature research and supporting a broad user community. Overall, the array of online/offline capabilities is described, including some of the recent developments for remote user support and the concomitant impact of the current pandemic. General overview of work done at HPCAT and with a focus on some of the minerals relevant work and supporting capabilities is also discussed. With the impending APS-Upgrade (APS-U), there is a considerable effort within HPCAT to improve and add capabilities. These are summarized briefly for each of the end-stations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Twin-pulse seeding enables pump-probe capabilities in the EUV to soft X-ray spectrum at synchrotron light sources

Having previously reported that separating the two stages of echo-enabled harmonic generation (EEHG) with one or more bending magnet (BM) sections allows the BMs to serve as the desired source of momentum compaction, here we demonstrate that this arrangement can greatly reduce the total energy modulation required by any 4th generation synchrotron light source, leading to higher repetition rates as well as stronger coherent radiation output power, with significant benefits. Since the EEHG beamline performance is mainly determined by the momentum compaction, beam emittances and beta functions of a storage ring lattice, allowing for different separations between the two stages is a straightforward way to increase the momentum compaction of chicane 1. This also enables pump-probe capabilities in a novel context, where twin-pulse seeding on the same electron bunch would allow two distinct radiation pulses with an adjustable delay in the range of 0.1 to 10 ps. In the twin-pulse seeding scheme, the same electron bunch could undergo modulation from two distinct laser pulses. Later stages would produce independent harmonics in subsequent straight sections. There are two variations of this twin-pulse seeding scheme, supporting different scientific applications. With a common modulation in stage 1, the first option allows simultaneously two independent radiation sources, with a full coverage of the EUV (2.5 to 50 nm) to soft X-ray (1.25 to 2.5 nm) spectrum; for the second option, the same stage 2 undulator could generate two coherent pulses both fitting within the FEL bandwidth, or at distinct harmonics. We present particle tracking simulation studies based on the APS-U lattice, including quantum excitation and radiation damping. These simulations indicate that there is no degradation of the modulated longitudinal phase space even when the two stages are separated by as many as 10 BM sections.

36 MATERIALS SCIENCE↗

Data Management at the Advanced Photon Source

Data are crucial to the scientific discoveries enabled by experiments performed at the APS. Presently the APS generates approximately 10 PB of raw experimental data per year from its sixty-six operating beamlines that house over 100 unique instruments. This data is generated as a part of over 6,000 annual experiments performed by over 5,500 facility users each year. Similar to other synchrotrons, the amount of data generated at the APS continues to quickly increase due to beamline advances, such as new measurement techniques, technological advances in detectors, high-throughput instrumentation, multi-modal instruments that can acquire several measurements in a single experiment, and advanced data processing algorithms. This trend is expected to continue in the future. The revolutionized high-energy synchrotron facility proposed in the APS-U project will increase brightness and coherence, leading to further increases in data rates. Successful management of data is of vital importance to the current and future scientific productivity of the APS.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Development of X-ray Wavefront Sensing Techniques for Adaptive Optics Control at the Advanced Photon Source

The planning and construction of new and upgraded high-brightness X-ray synchrotron and free electron laser sources, such as the Advanced Photon Source upgrade project (APS-U), are driving numerous opportunities to advance X-ray science and technologies. At the same time, an increasing number of highly diverse beamline experiments demand wavefront-preserving adaptive X-ray optics with both high precision and flexibility. At the APS, significant effort has been devoted to developing next-generation adaptive and corrective optics combined with state-of-the-art at-wavelength wavefront sensing techniques and an intelligent feedback control system for the automation and self-alignment of beamline optical systems. This article reviews recent achievements in these areas at the APS. Further, these include the development of in-situ wavefront sensing, the application in active feedback control of ultra-precision deformable mirrors, and the exploration of non-invasive wavefront sensing techniques for adaptive optics and beamline diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ROI-Finder : machine learning to guide region-of-interest scanning for X-ray fluorescence microscopy

The microscopy research at the Bionanoprobe (currently at beamline 9-ID and later 2-ID after APS-U) of Argonne National Laboratory focuses on applying synchrotron X-ray fluorescence (XRF) techniques to obtain trace elemental mappings of cryogenic biological samples to gain insights about their role in critical biological activities. The elemental mappings and the morphological aspects of the biological samples, in this instance, the bacterium Escherichia coli ( E. Coli ), also serve as label-free biological fingerprints to identify E. coli cells that have been treated differently. The key limitations of achieving good identification performance are the extraction of cells from raw XRF measurements via binary conversion, definition of features, noise floor and proportion of cells treated differently in the measurement. Automating cell extraction from raw XRF measurements across different types of chemical treatment and the implementation of machine-learning models to distinguish cells from the background and their differing treatments are described. Principal components are calculated from domain knowledge specific features and clustered to distinguish healthy and poisoned cells from the background without manual annotation. The cells are ranked via fuzzy clustering to recommend regions of interest for automated experimentation. The effects of dwell time and the amount of data required on the usability of the software are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XRF-ROI Finder: Machine Learning to Guide Region-of-Interest Scanning for X-ray Fluorescence Microscopy

The ROI-finder software is being developed for use by several Microscopy Group beamlines at Argonne National Laboratory, including 2-ID microprobes and 9-ID-B Bionanoprobe which use multi-scale scanning fluorescence microscopy to acquire elemental maps (multi-modal image data). Microscopy experiments require scan of samples at a coarse resolution followed by ROI identification using feature detection based on domain expertise. Finer resolution scans are then conducted based on identified ROI. The decision-making process based on domain expertise will be difficult to perform for faster data rates and much larger sampling volumes anticipated after APS-U necessitating the need for the ROI-finder software. The ROI- finder detects regions of interest through a continuous learning process, starting with a unsupervised representation learning and improving its recommendations through supervised learning and an interactive tool for user annotation. The scope of ongoing development efforts includes the integration of image registration module to correlate optical and X-ray images, extraction of feature morphology as well as elemental signatures in the image space and incorporation of beamtime streaming data by the scanning probe via EPICS.

CHOWDHURY, M. ARSHAD ZAHANGIR↗

Vertical Septum Magnet Design for the APS Upgrade

The vertical injection scheme proposed for the APS Upgrade (APS-U) Project requires a challenging septum magnet that must meet stringent beam physics, magnetic field leakage, and vacuum requirements. The current iteration of this magnet design includes an enlarged stored-beam chamber aperture of 9 mm x 12 mm and a reduction of the septum thickness to 1.5 mm. The enlarged aperture accommodates a non-evaporable getter (NEG)-coated stored beam chamber to better achieve the required vacuum. A prototype septum magnet has been built and measurements confirm the cancellation of a peak leakage field even though the value is six times larger than the design. The leakage field measured at the upstream (US) end cancels the downstream (DS) end as was expected by design. The measured and simulated leakage field and the stored beam trajectories are reported.

43 PARTICLE ACCELERATORS↗

New Insertion Device Control System for the APS Upgrade

New Hybrid Permanent Magnet Undulators (HPMUs) have been designed and manufactured using servo motors for precise and reliable gap motion control for the Advanced Photon Source Upgrade (APS-U) project. Meanwhile, existing HPMUs equipped with legacy stepper motors are systematically replaced with servo motors. In parallel with mechanical modifications of the undulators, a comprehensive upgrade has been implemented for the control of the devices. This upgrade includes integration of standardized industrial components for replacement of motor controllers and motor drives using the Kollmorgen Programmable Controller Multi-axis Master (PCMM) controllers and the AKD2G series servo drives. Soft Input Output Controllers (IOCs) are developed and deployed to replace the legacy VME-based IOCs for both single-period undulators and Revolver undulators. In this paper, we will present the architecture of the new insertion device control system, including control mechanisms, interlock protocols, and tools for diagnostics and troubleshooting.

Li, W.↗

NSLS-II FOFB Performance Improvement in 2019

APS-U declared that they have achieved 700 Hz to 1kHz fast orbit feedback (FOFB) closeloop bandwidth in their two-section test setup. Before this, most light sources have been running FOFB with 100-200Hz bandwidth. Table 1 shows the information of bandwidths and sampling rates of various Synchrotron facilities.

36 MATERIALS SCIENCE↗