Status of ASTM D8289 Optimization Studies
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.
Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.
This report formally documents the completion of the Advanced Reactor Technologies (ART) Level 3 Milestone (M3TG-24OR0501054), “Continue activities related to Split Disc-DIC - complete analysis of effect of sample thickness on one fine grain graphite,” due May 31, 2024. Details within this report outline the status of activities aimed at elucidating the effect of sample thickness on the tensile strength measurement using the small-disc, split-disc testing standard in support of the US Department of Energy’s ART Graphite R&D Program. The ASTM D8289, Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite, was developed to provide an alternative means for testing tensile strength on smaller specimens, which are compatible with available irradiation capsule volumes, and other compatibility measurements. ASTM D8289 specifies that acceptable specimen diameter can range from 6 to 12.7 mm and that the maximum allowed sample thickness should be half of the diameter. However, information is limited with respect to the effect of thickness on the measured splitting tensile strength. This report documents efforts to understand the effect of sample thickness on splitting tensile strength. The work involved testing Ø12.7 mm samples of fine-grain graphites 2114 and IG-110 of different thicknesses (6.35, 5, 4, and 3 mm). The digital image correlation (DIC) method was applied to the samples, along with the ASTM D8289 Standard, to help interpret the measured results.
The ASTM Brazilian disc graphite strength (splitting tensile strength, σ sts ) test method (ASTM D8289) is of interest because the small-specimen geometry is compatible with that of environmental effects specimens, thus allowing for environmental effects such as irradiation, irradiation creep, or oxidation on tensile strength to be investigated. The Brazilian disc strength of Mersen grade 2114 graphite is reported and compared with strength data previously obtained using larger cylindrical ASTM dog-bone specimens.
The ASTM Brazilian disc graphite strength (splitting tensile strength, σ sts ) test method (ASTM D8289) is of interest because the small-specimen geometry is compatible with that of environmental effects specimens, thus allowing for environmental effects such as irradiation, irradiation creep, or oxidation on tensile strength to be investigated. The Brazilian disc strength of Mersen grade 2114 graphite (billet 116310 slab 1) is reported and compared with strength data previously obtained using larger cylindrical ASTM dog-bone specimens and with Brazilian disc strength data obtained from billet 116310 slab 5.
Presentation will include baseline graphite characterization information, such as purpose and results, baseline property measurements, baseline graphite characterization method, baseline progress, split disc tensile strength: ASTM Tensile Strength Alternative, Identification of proper split disk fracture, baseline graphite ASTM D8289, horizontal orientation, digital image correlation, and DIC Analyzation.
Digital Image Correlation (DIC) is an optical technique that combines image registration and tracking methods for accurate two-dimensional and three-dimensional changes in images. DIC software can be used to track the contour, deformation, and strain of a sample. In the Advanced Test Reactor (ATR) at INL (Idaho National Laboratory) there exists a small working window of samples that can become irradiated. Hundreds of graphite disks called piggybacks have undergone this irradiation as part of the Advanced Reactor Technologies (ART) program. After irradiation, it is desirable to understand the change in tensile strength as a function of dose. Due to the limited space in the ATR, typical dog bone tensile tests reduce the number of graphite samples from hundreds to tens. However, there does exist an ASTM standard, D8289, which uses disc compression of graphite to estimate the tensile strength of the specimen with the Brazilian Disk test fixture. While only used as an estimate, which is typically off by a third, it is the purpose of this study to identify how to amend D8289 to remove the word "estimate" with the help of DIC.