Search NASA⌕ Search

SEARCH · Search NASA

Results for “ASTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3D characterization of a Great Basin geothermal system: Astor Pass, NV

The Great Basin exhibits both anomalously high heat flow (~75±5 mWm-2) and active faulting and extension resulting in robust geothermal activity. There are ~430 known geothermal systems in the Great Basin, with evidence suggesting that undiscovered blind geothermal systems may actually represent the majority of geothermal activity. These systems employ discrete fault intersection/interaction areas as conduits for geothermal circulation. Recent studies show that steeply dipping normal faults with step-overs, fault intersections, accommodation zones, horse-tailing fault terminations and transtensional pull-aparts are the most prominent structural controls of Great Basin geothermal systems. These fault geometries produce sub-vertical zones of high fault and fracture density that act as fluid flow conduits. Structurally controlled fluid flow conduits are further enhanced when critically stressed with respect to the ambient stress conditions. The Astor Pass blind geothermal system, northwestern Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Along this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range. As such, the Astor Pass area lies in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and more northerly striking normal faults. The Astor Pass tufa tower implies the presence of a blind geothermal system. Previous studies suggest that deposition of the Astor Pass tufa was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal fault. Subsequent drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming the presence of a blind geothermal system at Astor Pass. Expanding upon previous work and employing additional detailed geologic mapping, interpretation of 2D seismic reflection data and analysis of well cuttings, a 3-dimensional geologic model of the Astor Pass blind geothermal system was constructed. The 3D structural framework indicates that the Pleistocene tufa is associated with three discrete fault zones whose intersections plunge moderately to steeply NW-NNW. These critically stressed fault intersections act as conduits for upwelling geothermal fluids.

15 GEOTHERMAL ENERGY↗

Three-Dimensional Geologic Characterization of a Great Basin Geothermal System: Astor Pass, Nevada

The Great Basin, western USA, exhibits anomalously high heat flow (~75±5 mWm-2) and active faulting and extension, resulting in ~430 known geothermal systems. Recent studies have shown that steeply dipping normal faults in transtensional pull-aparts are a common structural control of these Great Basin geothermal systems. The Astor Pass blind (no surface expression) geothermal system, Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Across this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range, resulting in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and northerly striking normal faults. Previous studies indicate that Astor Pass was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal-dextral fault bounding the western side of the Terraced Hills. Drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming a blind geothermal system. Expanding upon previous work and employing interpretation of 2D seismic reflection data, additional detailed geologic mapping, and well cuttings analysis, a 3-dimensional geologic model of the Astor Pass geothermal system was constructed. The 3D model indicates a complex interaction/intersection area of three discrete fault zones: a northwest-striking dextral-normal fault, a north-northwest-striking normal-dextral fault, and a north-striking west-dipping normal fault. These two discrete, critically-stressed intersection areas plunge moderately to steeply to the NW-NNW and probably act as conduits for upwelling geothermal fluids.

15 GEOTHERMAL ENERGY↗

Three-Dimensional Geologic Characterization of Geothermal Systems: Astor Pass, Nevada, USA

Geothermal systems in the Great Basin, USA, are controlled by a variety of fault intersection and fault interaction areas. Understanding the specific geometry of the structures most conducive to geothermal circulation is crucial in order to both mitigate the costs of geothermal exploration (especially drilling) and to identify blind geothermal systems (no surface expression). Astor Pass, Nevada, one such blind geothermal system, lies near the boundary between two distinct structural domains, the Walker Lane and the Basin and Range, and exhibits characteristics of each setting. Both northwest-striking, left-stepping dextral faults of the Walker Lane and kinematically linked northerly striking normal faults associated with the Basin and Range are present at Astor Pass. Previous studies identified a blind geothermal system controlled by the intersection of northwest-striking dextral and north-northwest-striking normal faults. Wells drilled into the southwestern quadrant of the fault intersection yielded 94°C fluids, with geothermometers suggesting significantly higher maximum temperatures. Additional data, including reprocessed 2D seismic data and petrologic analysis of well cuttings, were integrated with existing and reinterpreted geologic maps and cross-sections to aid construction of a 3D geologic model. This comprehensive 3D integration of multiple data sets allows characterization of the structural setting of the Astor Pass blind geothermal system at a level of detail beyond what independent data interpretation can provide. Our analysis indicates that the blind geothermal system is controlled by two north- to northwest-plunging fault intersections.

15 GEOTHERMAL ENERGY↗

3D characterization of the Astor Pass geothermal system, Nevada

The Astor Pass geothermal system resides in the northwestern part of the Pyramid Lake Paiute Reservation, on the margins of the Basin and Range and Walker Lane tectonic provinces in northwestern Nevada. Seismic reflection interpretation, detailed analysis of well cuttings, stress field analysis, and construction of a 3D geologic model have been used in the characterization of the stratigraphic and structural framework of the geothermal area. The area is primarily comprised of middle Miocene Pyramid sequence volcanic and sedimentary rocks, nonconformably overlying Mesozoic metamorphic and granitic rocks. Wells drilled at Astor Pass show a ~1 km thick section of highly transmissive Miocene volcanic reservoir with temperatures of ~95°C. Seismic reflection interpretation confirms a high fault density in the geothermal area, with many possible fluid pathways penetrating into the relatively impermeable Mesozoic basement. Stress field analysis using borehole breakout data reveals a complex transtensional faulting regime with a regionally consistent west-northwest-trending least principal stress direction. Considering possible strike-slip and normal stress regimes, the stress data were utilized in a slip and dilation tendency analysis of the fault model, which suggests two promising fault areas controlling upwelling geothermal fluids. Both of these fault intersection areas show positive attributes for controlling geothermal fluids, but hydrologic tests show the ~1 km thick volcanic section is highly transmissive. Thus, focused upwellings along discrete fault conduits may be confined to the Mesozoic basement before fluids diffuse into the Miocene volcanic reservoir above. This large diffuse reservoir in the faulted Miocene volcanic rocks is capable of sustaining high pump rates. Understanding this type of system may be helpful in examining large, permeable reservoirs in deep sedimentary basins of the eastern Basin and Range and the highly fractured volcanic geothermal reservoirs in the Snake River Plain.

15 GEOTHERMAL ENERGY↗

3-Dimensional Geologic Modeling Applied to the Structural Characterization of Geothermal Systems: Astor Pass, Nevada, USA

Geothermal systems in the Great Basin, USA, are controlled by a variety of fault intersection and fault interaction areas. Understanding the specific geometry of the structures most conducive to broad-scale geothermal circulation is crucial to both the mitigation of the costs of geothermal exploration (especially drilling) and to the identification of geothermal systems that have no surface expression (blind systems). 3-dimensional geologic modeling is a tool that can elucidate the specific stratigraphic intervals and structural geometries that host geothermal reservoirs. Astor Pass, NV USA lies just beyond the northern extent of the dextral Pyramid Lake fault zone near the boundary between two distinct structural domains, the Walker Lane and the Basin and Range, and exhibits characteristics of each setting. Both northwest-striking, left-stepping dextral faults of the Walker Lane and kinematically linked northerly striking normal faults associated with the Basin and Range are present. Previous studies at Astor Pass identified a blind geothermal system controlled by the intersection of west-northwest and north-northwest striking dextral-normal faults. Wells drilled into the southwestern quadrant of the fault intersection yielded 94°C fluids, with geothermometers suggesting a maximum reservoir temperature of 130°C. A 3-dimensional model was constructed based on detailed geologic maps and cross-sections, 2-dimensional seismic data, and petrologic analysis of the cuttings from three wells in order to further constrain the structural setting. The model reveals the specific geometry of the fault interaction area at a level of detail beyond what geologic maps and cross-sections can provide.

15 GEOTHERMAL ENERGY↗

Astor Pass Seismic Surveys Preliminary Report

In collaboration with the Pyramid Lake Paiute Tribe (PLPT), the University of Nevada, Reno (UNR) and Optim re-processed, or collected and processed, over 24 miles of 2d seismic-reflection data near the northwest corner of Pyramid Lake, Nevada. The network of 2d land surveys achieved a near-3d density at the Astor Pass geothermal prospect that the PLPT drilled during Nov. 2010 to Feb. 2011. The Bureau of Indian Affairs funded additional seismic work around the Lake, and an extensive, detailed single-channel marine survey producing more than 300 miles of section, imaging more than 120 ft below the Lake bottom. Optim’s land data collection utilized multiple heavy vibrators and recorded over 200 channels live, providing a state-of-the-art reflection-refraction data set. After advanced seismic analysis including first-arrival velocity optimization and prestack depth migration, the 2d sections show clear fault-plane reflections, in some areas as deep as 4000 ft, tying to distinct terminations of the mostly volcanic stratigraphy. Some lines achieved velocity control to 3000 ft depth; all lines show reflections and terminations to 5000 ft depth. Three separate sets of normal faults appear in an initial interpretation of fault reflections and stratigraphic terminations, after loading the data into the OpendTect 3d seismic visualization system. Each preliminary fault set includes a continuous trace more than 3000 ft long, and a swarm of short fault strands. The three preliminary normal-fault sets strike northerly with westward dip, northwesterly with northeast dip, and easterly with north dip. An intersection of all three fault systems documented in the seismic sections at the end of Phase I helped to locate the APS-2 and APS-3 slimholes. The seismic sections do not show the faults connected to the Astor Pass tufa spire, suggesting that we have imaged mostly Tertiary-aged faults. We hypothesize that the Recent, active faults that produced the tufa through hotspring activity do not have enough offset to produce seismic terminations. We are conducting further high-resolution seismic studies (to 200 ft depths) at the tufa spire to test this hypothesis. Additional work in progress includes a collaborative, iterative joint interpretation of geologic mapping and the seismic sections for fault locations, building the geologic model; and 3d velocity modeling and imaging to locate additional faultplane images appearing between the 2d lines. Overall, the seismic exploration program cost less than $0.5M from all funders. It defines in detail the geologic structure of much of the north margin of Pyramid Lake.

01 COAL, LIGNITE, AND PEAT↗

A Preliminary Geochemical Description of the Geothermal Reservoir at Astor Pass, Northern Pyramid Lake, Nevada

Samples from a well drilled in the Astor Pass area six-km north of the Needle Rocks area of Pyramid Lake indicate that the reservoir fluid is dominantly sodium, chloride, and sulfate, with a pH between 8.6 and 8.9. The total dissolved solids in the reservoir is approximately 1600 mg/l, about half that of the TDS of the fluids in the Needle Rocks area. One sample of dissolved gas from fluids produced during a well test in the reservoir had 4 He value of 2.32 x 10 14 atoms 4 He/g water, or approximately 100 times the value of atmospheric 4 He. This measurement, in conjunction with a R/Ra measurement of 0.28, suggests that most of the reservoir helium is derived from the crust, with possibly a small value (~3.3 percent) derived from the mantle. Tritium concentration of the sample was 0.09 TU, indicating that the reservoir fluid was recharged more than 60 years ago; a simple model based upon carbon-14 suggests recharge has occurred within the past 1500 years.

15 GEOTHERMAL ENERGY↗

Advancements in 3D Structural Analysis of Geothermal Systems

Robust geothermal activity in the Great Basin, USA is a product of both anomalously high regional heat flow and active fault-controlled extension. Elevated permeability associated with some fault systems provides pathways for circulation of geothermal fluids. Constraining the local-scale 3D geometry of these structures and their roles as fluid flow conduits is crucial in order to mitigate both the costs and risks of geothermal exploration and to identify blind (no surface expression) geothermal resources. Ongoing studies have indicated that much of the robust geothermal activity in the Great Basin is associated with high density faulting at structurally complex fault intersection/interaction areas, such as accommodation/transfer zones between discrete fault systems, step-overs or relay ramps in fault systems, intersection zones between faults with different strikes or different senses of slip, and horse-tailing fault terminations. These conceptualized models are crucial for locating and characterizing geothermal systems in a regional context. At the local scale, however, pinpointing drilling targets and characterizing resource potential within known or probable geothermal areas requires precise 3D characterization of the system. Employing a variety of surface and subsurface data sets, we have conducted detailed 3D geologic analyses of two Great Basin geothermal systems. Using EarthVision (Dynamic Graphics Inc., Alameda, CA) we constructed 3D geologic models of both the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, NV. These 3D models allow spatial comparison of disparate data sets in 3D and are the basis for quantitative structural analyses that can aid geothermal resource assessment and be used to pinpoint discrete drilling targets. The relatively abundant data set at Brady’s, ~80 km NE of Reno, NV, includes 24 wells with lithologies interpreted from careful analysis of cuttings and core, a 1:24,000 scale detailed geologic map and cross-sections, 2D seismic reflection profiles and other geophysical data, and downhole temperature data. The 3D geologic model based on these data consists of 61 fault planes, 25 distinct stratigraphic units, and 2 intrusive bodies. Geothermal fluids are produced from a left step-over/relay ramp within the Brady’s Fault Zone (BFZ). Under local stress conditions, fault segments that strike NNE-to-NE are most likely to slip and/or dilate, and therefore transmit geothermal fluids. The 3D model defines the locations of discrete fault intersections within the BFZ and indicates that the densest zones of structurally controlled fracture permeability are ~10-to-10s of meters in diameter and plunge ~55° NW-NNW beneath the heart of the BFZ step over. The locations of high intersection density, high fault slip and dilation tendency, high subsurface temperature, and lithologies known to support high fracture permeability are combined to produce 3D ‘fairway’ maps useful in both assessments of geothermal resource potential and for defining drilling targets. Astor Pass is located on the Pyramid Lake Paiute Reservation, ~80 km north of Reno, NV. It is a prospective ‘greenfield’ geothermal area, and thus subsurface data are relatively sparse. Available data include: two relatively deep wells (~1400 m) and one shallower well (~500 m) with lithologies interpreted from drill cuttings, several 2D seismic reflection profiles, a 1:24,000 scale geologic map and cross-section, a shallow temperature survey, and downhole temperature data. 3D modeling based on these data has defined 19 distinct fault planes and 16 stratigraphic units. Based on the stress field calculated from borehole breakouts, drilling induced tensile cracks and petal-centerline cracks in the two relatively deep wells, 3D slip and dilation tendency analysis indicates that northerly striking fault segments are most likely to slip and/or dilate, and therefore transmit geothermal fluids. Analysis of fault intersection density indicates that the highest density of structurally controlled permeability within the field lies in a narrow (10-to-10s of m) zone plunging moderately (~35°) to the NNW beneath Pleistocene tufa deposits. This zone of increased fracture density, which we interpret as the primary upflow zone, is controlled by the intersection of N-to-NNW striking normal faults and a WNW striking dextral fault zone and represents the most promising target for future drilling. Construction of a 3D geologic model involves integration of a variety of data into an internally consistent framework. A robust model allows for spatial comparison between the various types of data (structural, stratigraphic, geophysical, temperature, etc.) that are commonly used independently to site geothermal wells. Furthermore, highly detailed 3D geologic models provide the basis for additional quantitative analysis, including 3D fault slip and dilation tendency analysis and the precise location of structurally controlled permeability pathways. These analyses provide detailed information relating to the internal dynamics of geothermal systems and can mitigate the costs and risks of geothermal exploration and development by contributing to better well targeting and more accurate evaluations of resource potential.

15 GEOTHERMAL ENERGY↗

Play-fairway analysis for geothermal exploration: Examples from the Great Basin, western USA

Elevated permeability within fault systems provides pathways for circulation of geothermal fluids. Future geothermal development depends on precise and accurate location of such fluid flow pathways in order to both accurately assess geothermal resource potential and increase drilling success rates. The collocation of geologic characteristics that promote permeability in a given geothermal system define the geothermal ‘fairway’, the location(s) where upflow zones are probable and where exploration efforts including drilling should be focused. We define the geothermal fairway as the collocation of 1) fault zones that are ideally oriented for slip or dilation under ambient stress conditions, 2) areas with a high spatial density of fault intersections, and 3) lithologies capable of supporting dense interconnected fracture networks. Areas in which these characteristics are concomitant with both elevated temperature and fluids are probable upflow zones where economic-scale, sustainable temperatures and flow rates are most likely to occur. Employing a variety of surface and subsurface data sets, we test this ‘play-fairway’ exploration methodology on two Great Basin geothermal systems, the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, NV. These analyses, based on 3D structural and stratigraphic framework models, reveal subsurface characteristics about each system, well beyond the scope of standard exploration methods. At Brady’s, the geothermal fairways we define correlate well with successful production wells and pinpoint several drilling targets for maintaining or expanding production in the field. In addition, hot-dry wells within the Brady’s geothermal field lie outside our defined geothermal fairways. At Astor Pass, our play-fairway analysis provides for a data-based conceptual model of fluid flow within the geothermal system and indicates several targets for exploration drilling.

15 GEOTHERMAL ENERGY↗

NEAR-SURFACE GEOPHYSICAL CHARACTERIZATION OF A HOLOCENE FAULT CONDUCIVE TO GEOTHERMAL FLOW NEAR PYRAMID LAKE, NEVADA

Linear deposits of calcium carbonate tufa columns mark recent faults that cut 11 ka Lake Lahontan sediments at Astor Pass, north of Pyramid Lake, Nevada. Throughout the Great Basin, faults appear to control the location of geothermal resources by providing pathways for fluid migration. Reservoir-depth (greater than 1 km) seismic imaging at Astor Pass reveals a fault that projects to one of the lines of tufa columns at the surface. The presence of the tufa deposits suggests this fault carried warm geothermal waters through the lakebed clay sediments in recent time. The warm fluids deposited the tufa when they hit cold Lake Lahontan water at the lakebed. Lake Lahontan covered this location 11 ka to a depth of at least 60 m. In collaboration with the Pyramid Lake Paiute Tribe, an Applied Geophysics class at UNR investigated the near-surface geophysical characteristics of this fault. The survey at and near the tufa columns comprises near-surface Pwave seismic reflection and refraction, electrical resistivity tomography, nearsurface refraction microtremor arrays, nine near-surface direct-current resistivity soundings, magnetic surveys, and gravity surveys. The refraction microtremor results show shear velocities near tufa and faults to be marginally lower, compared to Vs away from the faults. Overall, the 30-m depth-averaged shear velocities are low, less than 300 m/s, consistent with the lakebed clay deposits. These results indicate that no seismically fast (> 500 m/s) tufa deposits are present below the surface at or near the tufa columns. Vs30 averages were for example 274 ± 13 m/s on the fault, 287 ± 2 m/s at 150 m east of the fault, and 290 ± 15 m/s at 150 m west of the fault. The P-velocity refraction optimization results similarly indicate a lack of high-velocity tufa buried below the surface in the Lahontan sediments, reinforcing the idea that all tufa was deposited above the lakebed surface. The seismic results provide a negative test of the hypothesis that deposition of the lakebeds in the Quaternary buried and preserved older tufa columns within the section. Near-surface Wenner arrays with a-spacings up to 30 m show a higher resistivity near the faults, and tufa, than away from the faults. Resistivity averages within a few meters of the surface were 33 ± 17 ohm-m on the fault, 13 ± 3 ohm-m east of the fault, and 9 ± 3 ohm-m west of the fault. It is possible that the geothermal waters are fresher, and more resistive, than waters held in the lakebed clays. Water samples from more than 1 km depth in exploration wells have a TDS of 2500 p.p.m., nearly drinking-water quality. The relatively resistive water, perhaps localized by greater permeability along the fault, could explain the higher resistivity measured near the fault. The results show that there is no high-velocity, high-resistivity tufa along the faults below the surface, so we are unable to use buried tufa to locate the faults that may promote geothermal upwelling in this area. We further hypothesize that as sedimentation buried the tufa during the Quaternary, warm geothermal waters re-dissolved it, and re-precipitated it in the cold lake-bottom water.

15 GEOTHERMAL ENERGY↗

Three-Dimensional Geothermal Fairway Mapping: Examples From the Western Great Basin, USA

Elevated permeability along fault systems provides pathways for circulation of geothermal fluids. Accurate location of such fluid flow pathways in the subsurface is crucial to future geothermal development in order to both accurately assess resource potential and mitigate drilling costs by increasing drilling success rates. Employing a variety of surface and subsurface data sets, we present detailed 3D geologic analyses of two Great Basin geothermal systems, the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, Nevada. 3D modeling provides the framework for quantitative structural analyses. We combine 3D slip and dilation tendency analysis along fault zones and calculations of fault intersection density in the two geothermal systems with the locations of lithologies capable of supporting dense, interconnected fracture networks. The collocation of these permeability promoting characteristics with elevated heat represent geothermal ‘fairways’, areas with ideal conditions for geothermal fluid flow. Location of geothermal fairways at high resolution in 3D space can help to mitigate the costs of geothermal exploration by providing discrete drilling targets and data-based evaluations of reservoir potential.

15 GEOTHERMAL ENERGY↗

Developing Design Criteria for Safeguards Seals for Spent Fuel Transportation Casks

Current designs for spent fuel transportation casks cannot ensure a cask's integrity during shipment, nor is there any verifiable means of maintaining continuity of knowledge (CoK) on a cask's contents. Spent fuel destined for encapsulation plants or geological repositories requires additional containment and surveillance (C/S) measures during shipment. Following final safeguards accountancy measurements on spent fuel assemblies, the shipment of verified assemblies will require unprecedented reliance on maintaining CoK on the fuel inside transport casks. Such increased reliance is due to the lack of reverification of spent fuel following encapsulation into disposal canisters and by meeting the requirement of dual C/S measures during such fuel shipments according to recommendations made by the Application of Safeguards to Geological Repositories (ASTOR) International Atomic Energy Agency (IAEA) expert group. By designing spent fuel transportation casks with effective seals integrated into their design, CoK can be more effectively maintained than by ad hoc C/S measures because seal integration ensures that a cask has not been tampered with. Externally applied seals might not be able to provide such assurance for currently designed spent fuel transportation casks, although some combination of seals, detectors, and/or a technology that can verify canister integrity might provide this assurance. This paper examines the design criteria for integrating safeguards seals into transportation casks and provides recommendations for near-term applications.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stochastic Ion Acceleration by the Ion-cyclotron Instability in a Growing Magnetic Field

Using 1D and 2D particle-in-cell simulations of a plasma with a growing magnetic field ${\boldsymbol{B}}$, we show herein that ions can be stochastically accelerated by the ion-cyclotron (IC) instability. As ${\boldsymbol{B}}$ grows, an ion pressure anisotropy ${p}_{\perp ,i}\gt {p}_{| | ,i}$ arises due to the adiabatic invariance of the ion magnetic moment (${p}_{| | ,i}$ and $p_{⊥,i}$ are the ion pressures parallel and perpendicular to ${\boldsymbol{B}}$). When initially $β_ i$ = 0.5 (${\beta }_{i}\equiv 8\pi {p}_{i}/| {\boldsymbol{B}}{| }^{2}$, where $p_i$ is the ion isotropic pressure), the pressure anisotropy is limited mainly by inelastic pitch-angle scattering provided by the IC instability, which in turn produces a nonthermal tail in the ion energy spectrum. After ${\boldsymbol{B}}$ is amplified by a factor of ~2.7, this tail can be approximated as a power law of index ~3.4 plus two nonthermal bumps and accounts for 2%–3% of the ions and ~18% of their kinetic energy. On the contrary, when initially $β_i$ = 2, the ion scattering is dominated by the mirror instability, and the acceleration is suppressed. This implies that efficient ion acceleration requires that initially, $β_{i} \lesssim$ 1. Although we focus on cases where ${\boldsymbol{B}}$ is amplified by plasma shear, we check that the acceleration occurs similarly if ${\boldsymbol{B}}$ grows due to plasma compression. Our results are valid in a subrelativistic regime where the ion thermal energy is ~10% of the ion rest-mass energy. This acceleration process can thus be relevant in the inner region of low-luminosity accretion flows around black holes.

79 ASTRONOMY AND ASTROPHYSICS↗