Measurement of the Cesium-cesium Total Cross Section by Atomic Beam Techniques
Atomic beam measure of cesium-cesium total cross section
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Atomic beam measure of cesium-cesium total cross section
Metastable atom detection system for ground state atom beams, measuring Ar beam density five orders lower than background gas density
Here we generate an atomic beam of titanium (Ti) using a “Ti-ball” Ti-sublimation pump, which is a common getter pump used in ultrahigh vacuum systems. We show that the sublimated atomic beam can be optically pumped into the metastable 3d 3 ( 4 F)4s a 5 F 5 state, which is the lower energy level in a cycling optical transition that can be used for laser cooling. We measure the atomic density and transverse and longitudinal velocity distributions of the beam through laser fluorescence spectroscopy. We find a metastable atomic flux density of 4.3(2) × 10 9 s -1 cm -2 with a mean forward velocity of 773(8) m/s at 2.55 cm directly downstream of the center of the Ti-ball. Owing to the details of optical pumping, the beam is highly collimated along the transverse axis parallel to the optical pumping beam and the flux density falls off as 1/r. We discuss how this source can be used to load atoms into a magneto-optical trap.
Techniques to generate cold atom beams are of great interest in a variety of applications, from atomic frequency standards and atom optics to experimental studies of Bose-Einstein condensation. Cold atom beams have been produced by slowing thermal atomic beams using the Zeeman-slowing technique or chirped lasers, or using laser-cooling techniques to extract a slow atomic beam from the background gas in a low-pressure vapor cell. These laser-cooling techniques include "atomic funnels" or two-dimensional magneto-optical traps, as well as a variation of the conventional vapor cell magneto-optical trap called the "low-velocity intense source" (LVIS). Variations of the LVIS have been realized with unique trap geometries such as conical or pyramidal mirror traps. The present work implements a simple and robust design based on the pyramidal trap geometry and allows use of a single large diameter (<less than or = 20 cm) laser beam to obtain large capture rates of atoms from the background vapor. The four 45 deg mirrors are truncated just before the apex of the pyramid, and the 1 sq cm region at the center of the incident laser beam is retro-reflected by lambda /4 plate with a high-reflectance gold coating on the second surface. A small (1 mm diameter) hole in this retro-optic forms an extraction column for the atoms while maintaining a low conductance between the source region and an adjacent UHV chamber.
Measurement of momentum transfer from medium energy neutral atomic beams using torsion balance technique for beam calibration
A laser cooling apparatus that generates a cold beam of rubidium and cesium atoms at low pressure has been constructed as one of several intermediate products of a continuing program of research on laser cooling and atomic physics. Laser-cooled atomic beams, which can have temperatures as low as a microkelvin, have been used in diverse applications that include measurements of fundamental constants, atomic clocks that realize the international standard unit of time, atom-wave interferometers, and experiments on Bose-Einstein condensation. The present apparatus is a prototype of one being evaluated for use in a proposed microgravitational experiment called the Quantum Interferometric Test of Equivalence (QuITE). In this experiment, interferometric measurements of cesium and rubidium atoms in free fall would be part of a test of Einstein s equivalence principle. The present apparatus and its anticipated successors may also be useful in other experiments, in both microgravity and normal Earth gravity, in which there are requirements for dual-species atomic beams, low temperatures, and low pressures. The apparatus includes a pyramidal magneto-optical trap in which the illumination is provided by multiple lasers tuned to frequencies characteristic of the two atomic species. The inlet to the apparatus is located in a vacuum chamber that contains rubidium and cesium atoms at a low pressure; the beam leaving through the outlet of the apparatus is used to transfer the atoms to a higher-vacuum (lower-pressure) chamber in which measurements are performed. The pyramidal magneto-optical trap is designed so that the laser cooling forces in one direction are unbalanced, resulting in a continuous cold beam of atoms that leak out of the trap (see figure). The radiant intensity (number of atoms per unit time per unit solid angle) of the apparatus is the greatest of any other source of the same type reported to date. In addition, this is the first such apparatus capable of producing a slow, collimated beam that contains two atomic species at the same time.
An atomic beam apparatus capable of producing a collimated beam of O atoms or other atmospheric species at the STS impact velocity of 8 km/s is described. A conventional ion beam charge transfer neutralization approach was adopted to produce the projectile beam. The prime considerations favoring this approach are: the ability to vary the velocity of the impacting species at will over a wide range on either side of the optimum required value of 8 km/s; and sample irradiation can be made with species other than O-atoms, such as O2, N, or N2.
The performance of cold atom experiments relying on three-dimensional magneto-optical trap techniques can be greatly enhanced by employing a highflux cold atom beam to obtain high atom loading rates while maintaining low background pressures in the UHV MOT (ultra-high vacuum magneto-optical trap) regions. Several techniques exist for generating slow beams of cold atoms. However, one of the technically simplest approaches is a two-dimensional (2D) MOT. Such an atom source typically employs at least two orthogonal trapping beams, plus an additional longitudinal "push" beam to yield maximum atomic flux. A 2D atom source was created with angled trapping collimators that not only traps atoms in two orthogonal directions, but also provides a longitudinal pushing component that eliminates the need for an additional push beam. This development reduces the overall package size, which in turn, makes the 2D trap simpler, and requires less total optical power. The atom source is more compact than a previously published effort, and has greater than an order of magnitude improved loading performance.
Here, we have applied cavity ring-down spectroscopy (CRDS) to the study of the 166Er isotope in an atomic beam. These measurements were realized with an external cavity diode laser tuned to the 400.9 nm atomic transition of erbium and a customized high-finesse ring-down optical cavity under vacuum. Erbium atomic beams of different number densities were generated in a tantalum foil micro-crucible within the cavity. Absorbance values of the 166Er isotope between 3 × 10–6 and 7 × 10–5 were measured with a best-case precision on the order of 10–6, which is remarkable when considering the extreme temperatures at which the measurements were conducted, and the short detection path which is characteristic of collimated atomic beams. Number densities of erbium atoms were inferred to be between 2 × 106 and 6 × 107 cm–3. This work demonstrates for the first time the ability of studying dilute atomic beams of refractory materials with high accuracy utilizing CRDS. In these initial studies, we used erbium as a model system, but we expect to extend the proposed approach to the measurement of isotopes of uranium and plutonium for nuclear non-proliferation applications.
We have built an atomic beam source utilizing a simple and robust design based on the pyramidal trap geometry of Kim et al. Our design allows use of a single large diameter (\le20 cm) laser beam to obtain large capture rates of atoms from a background vapor. A small (about 1mm diameter) hole in the retro-optic at the apex of the pyramid provides an extraction column for the atoms. We have operated the apparatus both as a magneto-optical trap (using an auxiliary plug laser beam), and as a cold atomic beam source. The characterization of this large pyramidal beam source will be reported, including an investigation of scaling to very large (10--20cm) high power (about 1W) laser beams which should allow significant improvements in atomic beam flux.
Alkali polarizabilities by atomic beam electrostatic deflection method
The design and demonstration of an optical analysis system based on wavelength modulation spectroscopy in an atomic beam for uranium isotope abundance determinations is presented. This system probes the uranium 5f 3 6d7s 2 ( 5 L 6 ) → 5f 2 6d 2 7s 2 ( 5 K 5 ) transition at 861.031 nm, which is considered to be the most suitable transition for uranium isotopic analysis. A new laser characterization strategy was developed for the conditions where optimum laser wavelength modulation depth was small compared to the free spectral range (FSR) of etalons. Two capabilities enabled the higher-precision determination of isotope abundances of atomic beams: (1) reduction of low-frequency additive noise, especially the noise caused by black-body radiation and (2) suppression of non-absorption transmission losses. The performance of this system was validated with uranium samples of various isotopic compositions. Further, by comparing the measurements using natural uranium samples between the direct absorption and the wavelength modulation approaches, a 21-fold decrease in uncertainty of the integrated absorbance and a 6.8-fold improvement in the 1-σ precision of the number density were achieved. In addition, by comparing the results using uranium oxide samples, a 6.1-fold decrease in the uncertainty of inferred isotope abundance was obtained. These results demonstrate that the 1f-normalized 2f wavelength modulation spectroscopy (WMS-2f/1f) technique enables higher-precision analysis of atomic beams.
Polarized electrons produced by atomic beam apparatus - hyperfine structure intervals of alkali atoms
Calibration and characterization of the quadrupole mass spectrometer component of the Evaluation of Oxygen Effects on Materials III (EOIM-III) space-flight experiment are reported in this paper. A high-velocity atom beam system was used to characterize the response of the flight mass spectrometer to high velocity oxygen atoms as well as the reaction/scattering products formed when the atom beam struck a surface. Carbon dioxide, carbon monoxide, and water were observed to form in the mass spectrometer whenever high velocity oxygen atoms were present. The major gaseous products formed from high-velocity atom-beam polymer reactions were easily detected and identified.
Gas dynamics - gas-surface interactions using modulated atomic beam
An experiment to determine the absolute value of the photo-ionization cross section of atomic oxygen is described. The atoms are produced in an electrical discharge in oxygen gas with 1% hydrogen added. In order to prevent recombination a crossed beam technique is employed. The ions formed are detected by a time-of-flight mass spectrometer. The concentration of oxygen atoms in the beam is 57%. The measured photoionization cross section of atomic oxygen is compared with theoretical data. The results show the participation of autoionization processes in ionization. The cross section at the autoionizing levels detected is considerably higher than the absorption due to the unperturbed continuum. Except for wavelengths where autoionization occurs, the measured ionization cross section is in fair agreement with theory. This holds up to 550 A whereas for shorter wavelengths the theoretical values are much higher.
Cesium-cesium cross section measured at three angular resolutions by total atomic beam transmission through chamber containing cesium scattering atoms
Relative population and mean lifetimes of levels in hydrogen and helium atomic beams using foil method of excitation