Decision-related cortical potentials during an auditory signal detection task with cued observation intervals

Cortical-evoked potentials were recorded from human subjects performing an auditory detection task with confidence rating responses. Unlike earlier studies that used similar procedures, the observation interval during which the auditory signal could occur was clearly marked by a visual cue light. By precisely defining the observation interval and, hence, synchronizing all perceptual decisions to the evoked potential averaging epoch, it was possible to demonstrate that high-confidence false alarms are accompanied by late-positive P3 components equivalent to those for equally confident hits. Moreover the hit and false alarm evoked potentials were found to covary similarly with variations in confidence rating and to have similar amplitude distributions over the scalp. In a second experiment, it was demonstrated that correct rejections can be associated with a P3 component larger than that for hits. Thus it was possible to show, within the signal detection paradigm, how the two major factors of decision confidence and expectancy are reflected in the P3 component of the cortical-evoked potential.

Squires, K. C.

Vertex potentials evoked during auditory signal detection - Relation to decision criteria

Vertex potentials were recorded from eight subjects performing in an auditory threshold detection task with rating scale responses. The amplitudes and latencies of both the N1 and the late positive (P3) components were found to vary systematically with the criterion level of the decision. These changes in the waveshape of the N1 component were comparable to those produced by varying the signal intensity in a passive condition, but the late positive component in the active task was not similarly related to the passively evoked P2 component. It was suggested that the N1 and P3 components represent distinctive aspects of the decision process, with N1 signifying the quantity of signal information received and P3 reflecting the certainty of the decision based upon that information.

Squires, K. C.

Detectability of auditory signals presented without defined observation intervals

Ability to detect tones in noise was measured without defined observation intervals. Latency density functions were estimated for the first response following a signal and, separately, for the first response following randomly distributed instances of background noise. Detection performance was measured by the maximum separation between the cumulative latency density functions for signal-plus-noise and for noise alone. Values of the index of detectability, estimated by this procedure, were approximately those obtained with a 2-dB weaker signal and defined observation intervals. Simulation of defined- and non-defined-interval tasks with an energy detector showed that this device performs very similarly to the human listener in both cases.

Watson, C. S.

A psychophysiological evaluation of the perceived urgency of auditory warning signals

One significant concern that pilots have about cockpit auditory warnings is that the signals presently used lack a sense of priority. The relationship between auditory warning sound parameters and perceived urgency is, therefore, an important topic of enquiry in aviation psychology. The present investigation examined the relationship among subjective assessments of urgency, reaction time, and brainwave activity with three auditory warning signals. Subjects performed a tracking task involving automated and manual conditions, and were presented with auditory warnings having various levels of perceived and situational urgency. Subjective assessments revealed that subjects were able to rank warnings on an urgency scale, but rankings were altered after warnings were mapped to a situational urgency scale. Reaction times differed between automated and manual tracking task conditions, and physiological data showed attentional differences in response to perceived and situational warning urgency levels. This study shows that the use of physiological measures sensitive to attention and arousal, in conjunction with behavioural and subjective measures, may lead to the design of auditory warnings that produce a sense of urgency in an operator that matches the urgency of the situation.

Sound

NASA aviation safety reporting system

An analytical study of reports relating to cockpit altitude alert systems was performed. A recent change in the Federal Air Regulation permits the system to be modified so that the alerting signal approaching altitude has only a visual component; the auditory signal would continue to be heard if a deviation from an assigned altitude occurred. Failure to observe altitude alert signals and failure to reset the system were the commonest cause of altitude deviations related to this system. Cockpit crew distraction was the most frequent reason for these failures. It was noted by numerous reporters that the presence of altitude alert system made them less aware of altitude; this lack of altitude awareness is discussed. Failures of crew coordination were also noted. It is suggested that although modification of the altitude alert system may be highly desirable in short-haul aircraft, it may not be desirable for long-haul aircraft in which cockpit workloads are much lower for long periods of time. In these cockpits, the aural alert approaching altitudes is perceived as useful and helpful. If the systems are to be modified, it appears that additional emphasis on altitude awareness during recurrent training will be necessary; it is also possible that flight crew operating procedures during climb and descent may need examination with respect to monitoring responsibilities. A selection of alert bulletins and responses to them is presented.

Source record

Surgical evaluation of candidates for cochlear implants

The customary presentation of surgical procedures to patients in the United States consists of discussions on alternative treatment methods, risks of the procedure(s) under consideration, and potential benefits for the patient. Because the contents of the normal speech signal have not been defined in a way that permits a surgeon systematically to provide alternative auditory signals to a deaf patient, the burden is placed on the surgeon to make an arbitrary selection of candidates and available devices for cochlear prosthetic implantation. In an attempt to obtain some information regarding the ability of a deaf patient to use electrical signals to detect and understand speech, the Good Samaritan Hospital and Neurological Sciences Institute cochlear implant team has routinely performed tympanotomies using local anesthesia and has positioned temporary electrodes onto the round windows of implant candidates. The purpose of this paper is to review our experience with this procedure and to provide some observations that may be useful in a comprehensive preoperative evaluation for totally deaf patients who are being considered for cochlear implantation.

Non-NASA Center

NASA: Biomedical applications team

The status of projects involving the adaptation of NASA technologies for medical purposes is reviewed. Devices for the measurement of joint deformation of arthritic hands, the development of an artificial pancreas, provision of an auditory signal to avert epileptic seizures, are described along with the control of medication levels, a compressed air tank to supply power for field dentistry, and an electroencephalogram monitor. The use of the Lixiscope as a portable fluoroscope, thermal laminates for hand and foot warmers for patients with Raynaud's syndrome, and the use of absorptive coatings for instruments for controlling medication levels are described. The applicability of occupation health and safety practices to industry, computerized patient scheduling, impregnation of the common facial tissue with an agent for killing respiratory viruses, commercial applications of anthropometric data, and multispectral image analysis of the skin as a diagnostic tool are reviewed.

Source record

Altered auditory function in rats exposed to hypergravic fields

The effect of an orthodynamic hypergravic field of 6 G on the brainstem auditory projections was studied in rats. The brain temperature and EEG activity were recorded in the rats during 6 G orthodynamic acceleration and auditory brainstem responses were used to monitor auditory function. Results show that all animals exhibited auditory brainstem responses which indicated impaired conduction and transmission of brainstem auditory signals during the exposure to the 6 G acceleration field. Significant increases in central conduction time were observed for peaks 3N, 4P, 4N, and 5P (N = negative, P = positive), while the absolute latency values for these same peaks were also significantly increased. It is concluded that these results, along with those for fields below 4 G (Jones and Horowitz, 1981), indicate that impaired function proceeds in a rostro-caudal progression as field strength is increased.