Search NASA⌕ Search

SEARCH · Search NASA

Results for “AUXILIARY POWER SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterizing W sources in the all-W wall, all-RF WEST tokamak environment

In this work, experimental data, together with interpretive modeling tools, are examined to study trends in the tungsten (W) source in the all-W environment of the WEST tokamak, both from the divertor and from the main chamber. In particular, a poloidal limiter protecting an ion cyclotron resonance heating (ICRH) antenna is used as proxy for main chamber sourcing. The key study is carried out by stepping up lower hybrid current drive (LHCD) power, as the only auxiliary power source. Limiter and divertor W sources exhibit a qualitatively similar proportionality to the total power crossing the separatrix, P SEP , although the main chamber source remains substantially lower than the divertor source, for the range of P SEP accessible in the experiments. Intepretive modeling of the limiter source is carried out with a particle-in-cell (PIC) sheath model coupled to a surface sputtering model. Oxygen is used as a proxy for all light impurity species allowing for characterization of the critical W erosion regions. To get a good quantitative match to the data, it is necessary to assume that the oxygen arrives at the surface mostly at high ionization stages (4+ and above). A separate simulation with SOLEDGE-EIRENE, constrained to measured upstream scrape-off-layer plasma profiles, gives oxygen fractional abundances that are compatible with the PIC simulation result. This is understood to arise from transport processes that dominate over recombination. Substituting the LHCD by ICRH, in an equivalent experiment, the local W source exhibits a 3× enhancement. This can be matched by the simulation, by assuming local RF electric field rectification, based on ~100 eV peak-to-peak, near-antennna electric field. This work has highlighted the particular importance of understanding the ion charge state balance of light impurities as these are most likely the dominant sputtering species in fusion devices with high-Z walls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Material Selection and Sizing of a Thermoelectric Generator (TEG) for Power Generation in a Self-Powered Heating System

By employing the high temperature heat source to directly generate the electricity needed to power auxiliary systems in a natural gas furnace, boiler or hot water heater, a “self-powered” heating system can provide several benefits. Compared with a traditional furnace, boiler or hot water heater, when overall fuel utilization is kept constant, the self-powered system will have a higher primary energy efficiency, lower operating costs, and dramatically improved building safety and resilience during electric grid outages. Furthermore, a self-powered heating system only has a single utility connection – natural gas, without an electric connection – thus simplifying installation. A thermoelectric generator can be used for direct energy conversion of thermal energy to electricity with no moving parts, which offers a very simple means to provide power for the self-powered heating system, and the operation is without noise or vibration and can thus provide a very long system life. This paper provides an analysis focused on materials selection and the thermal power requirements for a thermoelectric generator (TEG) for use in a self-powered heating system. The dimensionless figure of merit for thermoelectric materials, zT, is used to estimate the optimal efficiency that can be achieved with a TEG to produce the electric power required in such an application. Comparisons of the predicted efficiency, the required heat transfer rate to the TEG and the heat transfer area needed for sustained operation under thermal conditions relevant to the self-powered heating application are made for several potential thermoelectric materials. This analysis was used to develop system requirements for a self-powered hot water heater using a TEG for electric power generation.

Laclair, Tim↗

Soft-switching voltage-edge-rate-limiting power inverter

An auxiliary resonant soft-edge pole inverter circuit is provided. The power inverter circuitry may include a first pair of capacitors in parallel with a corresponding pair of main power switching modules, each power switching module comprising a switch and a diode in parallel and sharing a common central node with the first pair of capacitors. The power inverter circuit may further include a first pair of auxiliary switches connected in series with a first pair of inductors, respectively, to generate resonant current from a DC power source, the first pair of inductors also sharing the common central node. The power inverter circuitry may further include a second pair of auxiliary switches connected in series with a second pair of capacitors, respectively, the second pair of auxiliary switches also sharing the common central node, the circuit producing an alternating current output at the common central node.

Wasynczuk, Oleg↗

Technical and Economic Assessment and Gap Analysis of Advanced Nuclear Reactor Integration with a Reference Oil Refinery

Efforts to identify the most-economic methods to decarbonize several sectors of the U.S. economy are underway. Industrial processes such as crude-oil refining rely heavily on energy-dense and easily stored and transported fossil fuels for powering their operations. Refineries use large amounts of energy, primarily derived from fossil sources to separate crude-oil components, break down heavier hydrocarbons into lighter compounds, remove impurities, reform hydrocarbon molecules, and generate steam and electricity for pumps and compressors and other various auxiliary systems. Crude-oil refining operations such as distillation, cracking, desulfurization, reforming, utilities systems and some offsite facilities collectively account for most of the energy consumption. Other operations such as hydrocracking or hydrotreating also require hydrogen for developing hydrogenation reactions which involve substantial heating to keep the reactors at high-temperature and pressure levels. All heat and energy demands are typically provided by natural gas (NG), oil, or other fuels, which makes refinery industry one of the most-difficult sectors to decarbonize. Nuclear power is a viable and energy-dense source of clean electricity, heat, and hydrogen to provide the large, sustainable energy supply that the refining industry demands. The U.S. Department of Energy’s (DOE’s) Integrated Energy Systems (IES) program is working to perform research and development, design, economic siting, and risk analysis. This state-of-the-art work will enable the first on-site demonstrations and commercial deployments of advanced small modular nuclear reactors (SMNRs) integrated with industries such as chemical production, refining, iron and steel making, and more. IES seeks to demonstrate the ability of advanced nuclear reactors to meet the heat and power demands of these industries while reducing carbon emissions in a sustainable and cost-competitive way. The primary objective of this research effort is to analyze industrial-scale SMNR integration intended to decarbonize refining facilities. The foreseen outcome is the provision of reliable, cost-competitive, and sustainable clean energy, alongside a reduction of carbon emissions. Specifically, the focus of this work lies on meeting the reference facilities’ heat and electricity demands with nuclear power while also supplying clean hydrogen via integrated high-temperature steam electrolysis (HTSE). This report presents a comprehensive technical and economic assessment of the integration of advanced nuclear reactors into a reference refinery, leveraging financial incentives from the Inflation Reduction Act (IRA). The evaluation aims to explore the potential economic benefits and challenges associated with incorporating advanced nuclear reactors into refinery operations, particularly in terms of energy efficiency, economic implications and environmental impact. By examining both the technical feasibility and economic viability, this analysis seeks to identify existing gaps and propose solutions for successful nuclear integration implementation. The findings are intended to provide valuable insights for stakeholders considering the adoption of advanced nuclear reactors in the refining sector. A refinery reference-plant was developed, using an open-source refinery model, Petroleum Refinery Lifecycle Inventory Model (PRELIM) and expert assessment, as a base case for comparison with various nuclear integration options. The capacity of 100 kbd/day (KBD) of heavy crude-oil feed was selected to represent a general coking-type refinery with deep conversion capabilities (incorporating heavy-oil upgrading with FCC, coking, and associated hydrotreating process units), using a heavy crude-oil feed, which represents about 70% of U.S. refineries configurations. A summary of all cases considered in this study is shown in Table 1.

13 HYDRO ENERGY↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Dual-Active-Bridge Converter Employing a Variable Inductor Without an Auxiliary Circuit

This paper proposes a dual active bridge (DAB) converter employing a variable inductor (VI) without an auxiliary circuit. Unlike conventional VI-based designs that require an external DC bias circuit, the proposed DAB utilizes the input DC current itself as the bias source, enabling automatic inductance variation with load conditions. The inductance naturally increases at low power and decreases at high power, effectively extending the zero voltage switching (ZVS) range and reducing circulating current, respectively. The VI was experimentally implemented and characterized to obtain its inductance-current profile, which was then integrated into a PLECS model of the DAB converter for circuit and thermal simulations. Simulation results confirm that the proposed auxiliary-free VI-DAB converter achieves a wider ZVS range and lower circulating current compared with a conventional fixed-inductor DAB converter. By realizing a variable inductor without any auxiliary bias circuitry, the proposed approach maintains soft switching and reduces reactive current losses across a wide load range, leading to improved efficiency and simplified implementation.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Design and Study of Inductively Coupled Plasma Chamber Components Using the SupRISE Test Device at DIII-D

The DIII-D National Fusion Facility aims to increase the auxiliary heating power for the tokamak by upgrading the Neutral Beam Injection (NBI) system. In collaboration with North Carolina State University, the conventional ‘arc and filament’ NBI ion sources will be converted to inductively coupled plasma (ICP) sources which utilize radio frequency (RF) coupling to maximize reliability for high power operation. In support of this initiative, a full scale test device (SupRISE, Superior Radiofrequency Ion Source Experiment) is currently under construction at the DIII-D Facility. In preparation for the construction of a full scale prototype that can be installed on the DIII-D NBI system, experiments on SupRISE will be conducted to determine the optimal RF frequency for high power coupling, Faraday shield slit configuration, and ICP chamber length. SupRISE is comprised of an approximately 30 x 70 cm quartz dielectric vessel with an internal Faraday shield enclosed in a secondary vacuum chamber to ensure structural stability of the dielectric. Actively cooled front and back plates are designed to reduce the thermal stresses on the plasma facing components and mate with the existing accelerator used by the NBI system at DIII-D. 50 kW of RF power will be coupled to the plasma through the quartz over a variable frequency range of 4-8 MHz to sustain a plasma density of ∼ 10 18 m −3 for a 10 s ON, 210 s OFF duty cycle. Various modelling efforts have been employed to simulate the thermal and stress profiles over the primary components of the SupRISE device as well as the inductance behavior of the RF antenna. These simulation results and the final design for SupRISE will be presented. An additional reduced-scale predecessor ICP source (called RISE) has been used to develop a predictive match model that will be applied to frequency optimization studies on SupRISE. Furthermore, the outcomes of this research and complementary efforts at North Carolina State University are essential for the incorporation of ICP NBI positive ion sources at the DIII-D facility.

DIII-D↗

Performance analysis of hybrid power configurations: Impact on primary energy intensity, carbon dioxide emissions, and life cycle costs

In this work, utilization of Natural gas and Hydrogen to support current and future building energy needs to offset the total electric demand while improving the grid resiliency and energy efficiency was investigated. Demand side energy management will play an important role in efficiently managing the available energy resources. Performance assessment of different power generation and energy management configurations is presented in this paper. Development of solutions in addressing grid resiliency by providing the ability to design suitable configurations for meeting individual building energy needs is discussed. Primary movers (PM) such as internal combustion engines (ICE) and fuel cells (FC) along with small scale auxiliary renewable energy source such as photovoltaics (PV) were considered. Key attributes of total carbon foot-print, life cycle costs including capital and operational expenditure, electric grid offset or peak shaving capability, thermal energy availability and its further potential to offset total electric demand, and primary energy intensity are analyzed and discussed in detail.

08 HYDROGEN↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Improving power grid transient stability and transfer capability using HVDC emergency power controls

In the future, with high levels of renewable energy sources penetration, the transmission corridors will have to be flexible to operate under faster transients and variable power flows. Fast power ramping and overloading capabilities of HVDC system can be utilized to ensure transient stability of the interconnected power grid. In this paper, HVDC auxiliary controllers have been studied that can provide the power grid with additional synchronizing torques through fast DC power changes in response to arising system conditions. The effectiveness of the auxiliary controllers in improving transient stability is demonstrated by performing dynamic simulations on the detailed model of the Western Interconnection system (WECC).

Sundaresh, Lakshmi↗

Event-Based Analysis of Solar Power Distribution Feeder Using Micro-PMU Measurements

Solar distribution feeders are commonly used in solar farms that are integrated into distribution substations. In this paper, we focus on a real-world solar distribution feeder and conduct an event-based analysis by using micro-PMU measurements. The solar distribution feeder of interest is a behind-the-meter solar farm with a generation capacity of over 4 MW that has about 200 low-voltage distributed photovoltaic (PV) inverters. The event-based analysis in this study seeks to address the following practical matters. First, we conduct event detection by using an unsupervised machine learning approach. For each event, we determine the event’s source region by an impedancebased analysis, coupled with a descriptive analytic method. We segregate the events that are caused by the solar farm, i.e., locallyinduced events, versus the events that are initiated in the grid, i.e., grid-induced events, which caused a response by the solar farm. Second, for the locally-induced events, we examine the impact of solar production level and other significant parameters to make statistical conclusions. Third, for the grid-induced events, we characterize the response of the solar farm; and make comparisons with the response of an auxiliary neighboring feeder to the same events. Fourth, we scrutinize multiple specific events; such as by revealing the dynamics to the control system of the solar distribution feeder. The results and discoveries in this study are informative to utilities and solar power industry.

14 SOLAR ENERGY↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Open-Source Parallel EMT Simulation Framework: Preprint

As the integration level of inverter-based resources (IBR) increases, ensuring the reliable operation of the bulk power systems requires the use of electromagnetic transient (EMT) simulation tools to identify and mitigate system-wide stability risks. Conducting EMT studies for large-scale, IBR-rich grids, however, is challenging due to the inherent computational bottleneck caused by the underlying high-fidelity models and required small time steps. This paper introduces ParaEMT: an open-source, generic EMT simulation framework designed to accelerate simulations by leveraging advanced parallel computational technologies, such as high-performance computers. This paper presents a comprehensive exposition of ParaEMT, covering its modeling library, simulation strategy, framework structure, operational procedures, and auxiliary features, alongside its extensible parallel computational architecture. Notably, ParaEMT is a publicly accessible and modularized framework written in Python, thereby facilitating future development and the integration of new models and algorithms. The accuracy and efficiency of ParaEMT are demonstrated by rigorous validations via multiple case studies.

electromagnetic transient simulation↗

An Open-Source Parallel EMT Simulation Framework

As the integration level of inverter-based resources (IBRs) increases, ensuring the reliable operation of the bulk power systems requires the use of electromagnetic transient (EMT) simulation tools to identify and mitigate system-wide stability risks. Conducting EMT studies for large-scale, IBR-rich grids, however, is challenging due to the inherent computational bottleneck caused by the underlying high-fidelity models and required small time steps. This paper introduces ParaEMT: an open-source, generic EMT simulation framework designed to accelerate simulations by leveraging advanced parallel computational technologies, such as high-performance computers. This paper presents a comprehensive exposition of ParaEMT, covering its modeling library, simulation strategy, framework structure, operational procedures, and auxiliary features, alongside its extensible parallel computational architecture. Notably, ParaEMT is a publicly accessible and modularized framework written in Python, thereby facilitating future development and the integration of new models and algorithms. The accuracy and efficiency of ParaEMT are demonstrated by rigorous validations via multiple case studies.

electromagnetic transient simulation↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

Technoeconomic Analysis of the Electrochemically Mediated Amine Regeneration CO 2 Capture Process

The electrochemically mediated amine regeneration (EMAR) process presents an alternative route to the conventional thermal amine regeneration for carbon capture from a flue gas source. In this study, we conducted an economic analysis on the EMAR system for postcombustion CO2 capture from a 550 MWe power plant capturing 3.1 MtCO2 annually and from a mini steel mill with annual capture close to 170 ktCO2. We followed the recommendation of the National Energy Technology Laboratory (NETL) 2010 report to estimate the cost of CO2 avoided ([$/tCO2]). Detailed cost modeling of the electrochemical separation stage was conducted. This is integrated with the entire process flowsheet (e.g., including absorber, compressor, pumps, and other auxiliary equipment). Here, we identified the membrane cost as the dominant capital cost for the electrochemical separation train. At a membrane unit price of less than 10/m2, the CO2 capture cost can be reduced to below 50/tCO2 with optimized process conditions (e.g., desorption pressure and utilization of waste heat). Improvements in process design, cell construction, and solvent formulation may lead to additional reductions in the CO2 capture cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpretation of Lyman opacity measurements in JET with the ITER-like wall using a particle balance approach

Recent measurements of the Ly β /D α ratio in the JET ITER-like wall (ILW) divertor show comparatively more pronounced Ly β reabsorption relative to previous results in JET with the carbon wall (JET-C). At the outer horizontal target ion current rollover point a Ly β reabsorption rate of 60% is measured, increasing to 80% in more pronounced detachment, implying a Ly α reabsorption rate of 90%–98%. The radially resolved Ly β /D α measurements are used to constrain Lyman opacity corrections to atomic rate coefficients using the population escape factor technique in order to capture the local changes to the excited state population structure in the high Lyman opacity regions at and outboard of the outer strike point. To check the self-consistency of the Lyman opacity measurements, a detailed spectroscopic interpretation of the outer divertor particle balance is presented, in which the impact of opacity corrections to the Ly α inverse photon efficiency coefficients is assessed. A five-fold deficit in the estimated D + source rate obtained with optically thin plasma assumptions is reconciled once the opacity corrections are factored into the Ly α photon rate to ionization rate conversion. The experiment results are reproduced in EDGE2D-EIRENE density scan simulations in which an imposed ad hoc Lyman reabsorption rate is recovered spectroscopically using synthetic measurements, and a similar shortfall in the D + source rate estimates is reconciled using Lyman opacity corrected atomic data. The model limitations prevent a more detailed self-consistent analysis of the Lyman opacity impact on divertor parameters and detachment evolution, and hence motivate renewed efforts to re-establish routine exploitation of the photon transport modelling capabilities in the EIRENE code package. Lyman opacity corrections to atomic data coefficients are necessary for spectroscopic interpretation of the JET-ILW divertor plasma, with significant influence on the divertor plasma also a likely consequence of the presence of strong Ly α reabsorption. Finally, a scan of auxiliary heating powers spanning L-mode and H-mode conditions reveals a strong correlation of the measured Ly β opacity with the outer target temperature, suggesting new possibilities for using Lyman opacity measurements in establishing detachment scalings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗