Search NASA⌕ Search

SEARCH · Search NASA

Results for “AXIAL RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Axial ratios and orientations for 100 Galactic globular star clusters

Axial ratios and major-axis orientations determined from image processing of Palomar and SRC Sky Survey material are tabulated for a sample of 100 Galactic globular clusters. From a subsample of 99 clusters, the mean axial ratio is found to be 0.93 + or - 0.01. Given that only 32 percent are flatter than b/a less than 0.9, and 5 percent flatter than 0.8, the clusters are found to be quite spherical. As predicted by King (1961 and 1966), tidal interactions by the Galaxy on the cluster are not the means by which the observed ellipticities are produced. Rather, Galactic absorption effects may have a moderate but not dominant effect on the clusters' observed ellipticities, as suggested by van den Bergh (1984). The alternate mechanisms of cluster rotation or anisotropic internal velocity distributions, or both, are considered to be more likely. The observed distribution of axial ratios is statistically indistinguishable from that of a similar-size sample of rotationally flattened clusters, which have axial-ratio values lying in the range of 0.75 less than b/a less than 0.83, and the major axes of which are oriented randomly in space.

White, Raymond E.↗

GPS Modeling and Analysis. Summary of Research: GPS Satellite Axial Ratio Predictions

This report outlines the algorithms developed at the Colorado Center for Astrodynamics Research to model yaw and predict the axial ratio as measured from a ground station. The algorithms are implemented in a collection of Matlab functions and scripts that read certain user input, such as ground station coordinates, the UTC time, and the desired GPS (Global Positioning System) satellites, and compute the above-mentioned parameters. The position information for the GPS satellites is obtained from Yuma almanac files corresponding to the prescribed date. The results are displayed graphically through time histories and azimuth-elevation plots.

Axelrad, Penina↗

Design and performance of an 0.8 hub-tip ratio axial flow pump rotor with a blade tip diffusion factor of 0.55

A 22.9-centimeter diameter axial flow rotor with a 0.8 hub-tip radius ratio, a design flow coefficient of 0.466, and a blade tip design diffusion factor of 0.55 was tested in cold water under both cavitating and noncavitating conditions. Radial surveys of the flow conditions at the rotor inlet and outlet were made. At design flow, the rotor produced an overall headrise coefficient of 0.360 with an overall efficiency of 95.0 percent. The efficiency remained greater than 88 percent over the entire flow coefficient range which varied from 0.350 to 0.615.

Urasek, D. C.↗

A Flat-Panel 8x8 Sequentially Rotated Wideband Microstrip Patch Phased Array Antenna for K/Ka-band 6U CubeSat Communications Applications

Flat-panel electronically-scanned phased arrays have recently become a mainstream technology in the areas of radar and satellite applications, particularly due to their low profile and not having to steer the beams mechanically, both of which helps in realizing a lightweight phased array solution that also occupies a smaller volume. Typically for satellite applications, circularly polarized element radiators are often employed in order to deal with the signal fading problem. In this project, the main objective was to design a flat-panel phased array solution for 6U CubeSat communication applications. As for the required specifications, the array should have two operating bands: 22.55–23.55 GHz and 25.5–27.5 GHz, which span part of the K and Ka bands. For both these bands, the panel should be able to radiate dual circular polarization, in both transmit and receive modes, and with a stable gain performance. Since the individual bands are very closely spaced, it was realized that a single wideband design would be a better solution than a closely spaced dual-band design. Thus, a stacked microstrip patch configuration was selected for the element radiator design, which is known to be wideband. Now, it is rather difficult to realize both wide impedance and axial ratio bandwidths simultaneously, and at high frequencies, without complicating the element stacked patch design.. As a result, a sequential rotation technique wasemployed to significantly improves the axial ratio bandwidth and circular polarization purity of an array, all the while improving the pattern symmetry (P. S. Hall, “Application of Sequential Feeding to Wide Bandwidth, Circularly Polarised Microstrip Patch Arrays,” IEE Proc. H (Microw., Antennas Propag.), vol. 136, no. 5, pp. 390–398, Oct. 1989). The designed element radiator is a circularly-polarized probe-fed stacked patch antenna, which has a 10-dB matching bandwidth of 22.3– 30 GHz, with only a 5.14% axial ratio bandwidth around the center frequency of the required band, i.e., ~25 GHz. However, the resulting array demonstrates a very low axial ratio (≪ 3 dB) over the entire bandwidth, due to the application of the sequential rotation technique. The 8×8 array was able to scan up to ±51° and ±40° at frequencies 23.05 GHz and 26.5 GHz (center frequencies of the lower and upper bands), respectively, while maintaining a ≤ 3 dB axial ratio and a ≤ 3 dB gain drop from the corresponding peak broadside value at both the principle and the diagonal radiation planes. The designed layout for the 8×8 phased array prototype is shown in Fig. 1, which is currently undergoing fabrication and RF assembly. The antenna will be tested in the far-field anechoic chambers of the Antenna and Microwave Laboratory (AML) at San Diego State University and at NASA Glenn Research Center (GRC).

5G↗

A note on the influence of axial velocity ratio on cascade performance

A thin airfoil quasi-two-dimensional potential flow theory has been used to analyze cascades with axial-flow contraction. Attention is centered on the flow turning of a lattice of foils as measured by the deviation angle. The influence of both axial-flow acceleration and foil thickness on the deviation angle is summarized in plots that should be useful for design purposes. It is shown that the effect of axial-flow contraction is larger when the foils are relatively far apart than when they are close together. The influence of axial velocity ratio across the cascade changes markedly with the stagger angle. These effects are essentially unaltered due to foil thickness.

Wilson, M. B.↗

Effect of Various Blade Modifications on Performance of a 16-Stage High-pressure-ratio Axial-flow Compressor.Angles 3 deg: Effect on Over-all Performance Characteristics of Decreasing Twelfth Through Fifteenth State Stator-blade Angles 3 deg - 1

The stator-blade angles in the twelfth to fifteenth stages of a 16-stage high-pressure-ratio axial-flow compressor were decreased 3 deg The over-all performance of this compressor is compared with the performance of the same compressor with standard blade angles. The matching characteristics of the modified compressor and a two-stage turbine were also obtained and compared with those of the compressor with the original blade angles and the same turbine.

Medeiros, Arthur A.↗

All-Metal Dual Band Circular Polarized UHF Patch Antenna

An all-metal circularly polarized UHF antenna element is presented. The patch antenna gives a wideband impedance and axial ratio bandwidth of 24% over the 0.3-0.38 GHz frequency band with 90% efficiency. The main advantage is the use of a single feed point to generate circular polarization (CP). The antenna can be used to set up a dual-band (0.3-0.32 GHz and 0.36-0.38 GHz) communication link, with an axial ratio better than 3 dB and a realized CP gain better than 8 dBiC and 10 dBiC, respectively. The interaction between the cavity walls and the patch element, results in near-field coupling and improves the impedance bandwidth as well as the axial ratio bandwidth of the antenna. Being a high gain, high aperture efficiency, low profile, light weight, and single feed point radiating element, this single patch antenna is an excellent candidate for future antenna array.

Chahat, Nacer↗

A Dual Linear/Circular Polarized Wideband Flat Panel Phased Array Antenna for K/Ka-band 6U CubeSat Communications Applications

Circular polarized (CP) electromagnetic waves are preferred for space-to-space and space-to-ground satellite communications (SATCOM). CubeSats with 6U sizes (1U represents a 10 cm x 10 cm x 10 cm), that will rotate together with the Moon as it orbits Earth require high gain CP antenna systems to maintain reliable communication links. Here, we have designed an 8x8 dual linear and dual circularly polarized phased array antenna (PAA) aperture that offers 22-28 GHz bandwidth, with maximum gain of 23 dBic, and beam scanning capability of ±50o with acceptable axial ratio over all scan angles. A stacked patch topology is selected to achieve wide impedance bandwidth. Each driven patch has two via feed point locations that are connected to grounded coplanar waveguide (CPW) feed structures. By utilizing phase shifters from the Anokiwave RFICs (AWMF-0165) employed for the beamforming network (BFN), we have generated both dual linear polarization and dual circular polarization in each patch. Each driven and parasitic patch is innovatively shaped to achieve excellent isolation between two feed points which, in turn, leads to low cross polarization, high efficiency and good axial ratio over the entire bandwidth. Each chip has eight outputs which feed one 2x2 sub-array consisting of four dual linear or dual circularly polarized driven patches, simultaneously. Each 2x2 sub-array of the 8x8 array are sequentially rotated which improves axial ratio performance when the antenna operates in the dual circularly polarized mode. By utilizing a mirror effect, cross-polarized fields are also improved when operated in a dual linear polarized mode. The 8x8 array aperture is simulated taking into account the effect of the multilayer printed circuit board (PCB) stack-up of the BFN and co-simulated with the power splitter outputs and chip outputs and results are compared with only passive array performance. The performance of the antenna is still excellent when non-ideal chip performances are included in the simulation analysis. The fabricated array will be tested for radiation patterns in the Antenna and Microwave Laboratory (AML) of the San Diego State University and the NASA Glenn Research Center (GRC) spherical near field chambers. The design of the 8x8 antenna array with BFN layout is shown in Fig. 1.

5G↗

Aerodynamic performance of a 1.25-pressure-ratio axial-flow fan stage

Aerodynamic design parameters and overall and blade-element performances of a 1.25-pressure-ratio fan stage are reported. Detailed radial surveys were made over the stable operating flow range at rotative speeds from 70 to 120 percent of design speed. At design speed, the measured stage peak efficiency of 0.872 occurred at a weight flow of 34.92 kilograms per second and a pressure ratio of 1.242. Stage stall margin is about 20 percent based on the peak efficiency and stall conditions. The overall peak efficiency for the rotor was 0.911. The overall stage performance showed no significant change when the stators were positioned at 1, 2, or 4 chords downstream of the rotor.

Moore, R. D.↗

Performance of High-pressure-ratio Axial-flow Compressor Using Highly Cambered NACA 65-series Blower Blades at High Mach Numbers

A complete stage of an axial-flow compressor was designed and built to investigate the possibility of obtaining a high pressure ratio with an acceptable efficiency through the use of the optimum combination of high blade loading and high relative inlet Mach number. Over-all stage performance was investigated over a range of flows at equivalent tip speeds of 418 to 836 feet per second. At design speed (836 ft/sec), a peak total-pressure ration of 1.445 was obtained with an adiabatic efficiency of 0.89. For design angle of attack at the mean radius, a total-pressure ratio of 1.392 was obtained.

COMPRESSORS - AXIAL FLOW↗

Aerodynamic performance of a 1.35-pressure-ratio axial-flow fan stage

The overall blade element performances and the aerodynamic design parameters are presented for a 1.35-pressure-ratio fan stage. The fan stage was designed for a weight flow of 32.7 kilograms per second and a tip speed of 302.8 meters per second. At design speed the stage peak efficiency of 0.879 occurred at a pressure ratio of 1.329 and design flow. Stage stall margin was approximately 14 percent. At design flow rotor efficiency was 0.94 and the pressure ratio was 1.360.

Osborn, W. M.↗

Experimental Investigation of a 0.35 Hub-Tip Radius Ratio Transonic Axial Flow Rotor Designed for 40 Pounds per Second per Square Foot with a Design Tip Diffusion Factor of 0.20

In order to determine the effect of a low design diffusion factor on the performance of a transonic axial-flow compressor rotor, a high-specific-flow rotor with a 0.35 hub-tip radius ratio was designed, fabricated and tested. This rotor used a design tip diffusion factor of 0.20 with a design corrected specific weight flow of 40 pounds per second per square foot of frontal area, a total-pressure ratio of 1.27, and an adiabatic efficiency of 0.96. The design, rotor performance, and blade element performance are presented with a discussion on rotor shock losses and a comparison with a similarly designed rotor with a tip diffusion factor of 0.35. At the design corrected tip speed of 1100 feet per second, a peak rotor adiabatic efficiency of 0.88 was attained at a corrected specific weight flow of 39 pounds per second per square foot of frontal area with a mass-averaged total-pressure ratio of 1.27. The blade element tip diffusion factor was 0.281, which is 0.08 higher than the design value of 0.20. Peak efficiencies of 0.95, 0.91, 0.89, and 0.85 were obtained at 70, 80, 90, and 110 percent of design speed, respectively. Comparison of the performance of the rotor reported herein and a similarly designed rotor with increased blade loading indicates that higher blade loading results in a more desirable rotor because of a higher pressure ratio and equivalent efficiency. Computed values of shock losses at the rotor tip section indicate that the losses at peak efficiency are primarily a function of shock losses since the profile losses are only a small percentage of the total loss.

Yasaki, Paul T.↗

Performance of a 1.15-pressure-ratio axial-flow fan stage with a blade tip solidity of 0.5

The overall and blade-element performance of a low-solidity, low-pressure-ratio, low-tip-speed fan stage is presented over the stable operating range at rotative speeds from 90 to 120 percent of design speed. At design speed a stage peak efficiency of 0.836 was obtained at a weight flow of 30.27 kilograms per second and a pressure ratio of 1.111. The pressure ratio was less than design pressure ratio, and the design energy input into the rotor was not achieved. A mismatch of the rotor and stator blade elements resulted due to the lower than design pressure ratio of the rotor.

Osborn, W. M.↗

Evaluation of a low aspect ratio small axial compressor stage, volume 1

A program was conducted to evaluate the effects of scaling, tip clearance, and IGV reset on the performance of a low aspect ratio compressor stage. Stage design was obtained by scaling an existing single stage compressor by a linear factor of 0.304. The design objective was to maintain the meanline velocity field of the base machine in the smaller size. Adjustments were made to account for predicted blockage differences and to chord lengths and airfoil edge radii to obtain reasonable blade geometries. Meanline velocity diagrams of the base stage were not maintained at the scaled size. At design speed and flowrate the scaled stage achieved a pressure ratio of 1.423, adiabatic efficiency of 0.822, and surge margin of 18.5%. The corresponding performance parameters for the base stage were 1.480, 0.872, and 25.2%, respectively. The base stage demonstrated a peak efficiency at design speed of 0.872; the scaled stage achieved a level of 0.838. When the scaled stage rotor and stator tip clearances were doubled, the stage achieved a pressure ratio of 1.413, efficiency of 0.799, and surge margin of 16.0% at the design flowrate. The peak stage efficiency at design speed was 0.825 with the increased clearance. Increased prewhirl lowered the stage pressure ratio as expected. Stage efficiency was maintained with ten degrees of increased prewhirl and then decreased substantially with ten additional degrees of reset.

Sawyer, C. W., III↗